Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 | |
| 2 | L2₹17.4 L+₹3.6 L (26.3%)Rejected-Finance 27 ABUSETH ROAD DEHU ROAD PUNE 412 101 | NA | NA | 412101 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹18.7 L+₹4.9 L (35.4%)Rejected-Finance CITY SURVEY NO 111 15 9 VIJAYA NAGAR KALEWADI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹19.3 L+₹5.5 L (40.2%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹19.8 L+₹6.1 L (43.9%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DEHU ROAD, PUNE
GE DEHU ROAD, PUNE
CERTAIN REPAIR TO SEWAGE LINES MAN HOLES SEPTIC TANK CLEANING OF SEWAGE LINE OF MD OTM ACCN OF ODTD SHIVAJI ENCLAVE AND UNIT 495 UNDER AGE BR WEST AT GE DEHU ROAD
2021_MES_435991_1
8511
Open Tender
Civil Works
Item Rate
270 days
GE DEHU ROAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE DEHU ROAD, PUNE
₹60,000
Yes
29 May 2021
12 Apr 2021
17 May 2021
12 Apr 2021
10 May 2021
26 Apr 2021
60 days
Amount
Cleaning sewage line 100mm bore SGSW / RCC pipe upto 1.5 M below ground level with mechanical cleaning device and water jets etc and bringing out all foreign materials / mud sludge etc. from the lines removing the same through the manholes and cleaned with water complete all as specified and directed.
All as per item No. 01 above for 150 mm dia line and upto 1.5 m in depth below GL complete all as specified and directed.
All as per item No. 01 above for 200 mm dia line and upto 1.5 m in depth below GL complete all as specified and directed.
Cleaning of septic tank of any depth by removing of sludge, silt, or mud etc. First by dewatering with mechanical systems of septic tanks and filter beds with mechanical pumps and sucking out or mechanically removing the accumulated sludge , silt and mud etc, from beds, burring and chlorinated in the ground and removing the same outside MD land including cleaning of surfaces completely with water etc complete. Note:- solid material only be measured and element of dewatering is deemed to be included in rates.
All as per item no. 04 above but only cleaning of Man Holes upto 1.00 mtr depth complete all as specified and directed.
All as per item no. 04 above but only cleaning of Man Holes exc 1.00 mtr depth but n exc 2.00 mtr depth complete all as specified and directed.
Excavation in trenches n exc 1.5m deep & n exc. 1.5m wide and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including levelling , watering and well ramming in layers n exc 25 cm thick in soil complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance n exc. 50 M & depositing where directed at a level n exc. 1.5 M above starting point complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced )as in manholes cover complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars etc , precast concrete articles and precast concrete block walling built in cement mortar complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge
Dismantling/ taking down AC waste / vent pipes fixed to walls with all fittings/ accessories, 100 mm dia pipes all as specified and directed by Engineer-in-Charge
Demolition and breaking up drain pipes (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortat , 150 mm dia pipes, all as specified and directed by Engineer-in-Charge.
All as item No.16above but for internal dia of pipe 200mm dia complete all as specified and directed .
All as item No.16 above but for internal dia of pipe 300mm dia complete all as specified and directed .
M&L for PCC (1:4:8) type D-2 (Using 40mm granded stone aggregate ) as in foundations,filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for precast reinforced cement conrete (1:2:4) type B-1 (20mm graded stone agg) as in cover slabs for man holes, set and jointed in CM (1:4) complete all as specified and directed Note:- Reinforcement shall be measured and paid separately.
M&L for mild steel TMT bars 6 to 8 mm dia and over cut to length, bent to shape required incl cranking, bending, hooking ends & binding with & incl mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surface incl mixing of water proofing compound finished even & smooth with using extra cement complete all as specified and directed by Engineer-in-Charge. (Note: WPC shall be measured & paid seperately)
Supply only liquid water proofing compound.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) bends, any radius with access door complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) branch piece (Single Y) equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) branch piece double, (Double Y) equal or unequal complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes 75 mm dia ,single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) bends any radius, 75mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal,for 75mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) branch piece, double (double Y), equal or unequal,for 75mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F75 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
S&F in repairs grating doom 100mm dia of PTMT complete all as specified and directed. (minimum weitht 25 gms).
M&L for reinforced cement concrete pipes class NP-3, laid in trenches & jointed complete with collars, dia of pipe 150 mm complete all as specified and directed by Engineer-in-Charge.
All as item No. 35 above but for 200 mm dia of pipe complete all as specified and directed by Engineer-in-Charge.
All as item No. 35 above but for 300 mm dia of pipe complete all as specified and directed by Engineer-in-Charge.
M&L concrete bed for 150 mm dia drain pipe in PCC 1:4:8 type D-2 including forming cradles complete all as specified and directed.
All as item No. 37 above but for 200 mm dia RCC pipe.
All as item No. 37 above but for 300 mm dia RCC pipe.
M&L in repairs PVC (SWR) gully trap 125/100 mm, setting /joiting with solvant cement complete all as specified and directed .
Supply and fix in repair hume pipe septic tank 10 users capacity inclding all excavation earth work required and demolition and removal of old septic tank (any size) and removal of debris and connecting the new septic tank to the incoming sewer lines and connectd to soak pit as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and backing complete all as specified and directed .
M & L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors, etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match. Including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete.
M & L for Glazed ceramic tiles in vertical surface 450mm x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles incl backing coat 10mm thick in CM 1:4 all as direced.
S&F in repairs vitreous china squating pan Orissa pattern of size 580x440 mm white with 'P' trap front or back inlet and foot rest any pattern complete all as specified and directed.
S&F in repairs 10 ltr capacity PVC valve less syphonic action type flushing cistern low level, white with inlet ball valve, float and handle including necessary brackets & screws, flush pipe as required complete all as specified and directed.
S/F in repairs Vitreous china wash basin white flat back size 550 x 400mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand along with 32mm dia CP waste coupling and PVC waste pipe complete all as directed.
S & F in repairs pillar taps fancy type cromium plated with capstan heads, chromium plated, screwed down high pressure, and fly-nuts, screwed for iron pipe and fixed for 15 mm dia pipe complete all as specified and directed .
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repairs 75mm dia PVC (SWR) floor trap plain with gratings including jointing with solvent cement complete all as specified and directed.
M&L for cleaning of all blockage of any type of trap, water closet, soil waste/vent pipe, gully traps upto first manhole by removing all chocked materials by any suitable means and equipment including foreign materials and removing the same to a distance exceeding 100 mtr and n exc 200 mtr and making good the disturbed surfaces as per existing where required and as directed by Engineer-in-Charge
Star Construction
M/S RENUKA CONSTRUCTIONS
Shri Sant Cosntruction
Samyak Engineers
PREETI ENTERPRISES
M/S B.A. GAIKWAD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .