Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC 8 6TH CROSS MATHRU SHREE NILAYA OPP MAHARISHI RESIDENCE KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹44.3 L+₹42,448 (0.97%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹49.4 L+₹5.5 L (12.6%)Rejected-Finance | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹51.0 L+₹7.1 L (16.2%)Rejected-Finance | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹51.5 L+₹7.6 L (17.4%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-Finance rejected being L5 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
24 Aug 2020, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
COMPREHENSIVE MAINT OF E M SERVICE CELL SEWAGE LINE LIFT AND REPAIR MAINTENANCE OF BUILDINGS SECURITY LIGHTS POST TOP LATTERN HT CABLING WORKS AND OTHER EM WORKS IN VARIOUS DIVISION AT DFRL MYSORE
2020_MES_366121_1
8966
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I R AND D East Bangalore
D b (ii) d (v)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹92,000
Yes
6 Nov 2020
3 Aug 2020
28 Aug 2020
3 Aug 2020
24 Aug 2020
19 Aug 2020
4 Aug 2020 - 18 Aug 2020
Amount
Manning of E/M service cell including attending day to day electrical complaints in DFRL Area, Residential area and MES Office and residential area complete all as specified and as directed
(a) Nature of work to be carried out/attended as under:-
(i) Registering and attending all day to day complaints for DFRL Residential area MES Office and MES residential area including street lights and as directed by Engineer-in-Charge.
(ii) Replacement of electrical items such as switches, socket holders, bulb/tubes chokes etc including attending the power failure complaint and rectifying the same.
(iii) Maintenance of complaint register and complaint slip
(iv) Repairing of street light/boundary light as and when reqd in DFRL tech area, residential area and MES complex complete all as directed.
(v) Pruning of trees obstructing LT distribution line in DFRL residential area as and when required.
(vii) Rate quoted shall include for replacement of worn out / blown HT DO fuses as and when required on 4 pole structure in Tech area
(vii) Rate quoted shall include for printing necessary complaint register and complaint slip.
Note:- (i) All stores required to carryout the work will be supplied by the department.
(ii) Tools required for electrician and cutting tools for pruning trees shall be provided by the contractor.
(iii) Aluminium ladder for repairing street light shall be provided by the contractor.
(iv) The cost of providing additional labours to carry mobile type step ladders and repairs of street light and pruning trees once in a week is deemed to have been included in the rate quoted.
Shift timing: 0600 Hrs to 1400 hrs- 01 No Electrician and 01 No Helper 1400 Hrs to 2200 HRS-01 No Electrician and 01 No Helper
Maintenance of external sewage lines, manholes, gully traps and removal of waste materials etc at DFRL as under:-
(a) Clearing blockages in external sewage lines between bldgs and manholes and manholes to manholes etc as required and as directed by the Engineer-in-charge.
(b) Checking all manholes once in a week and attending the overflow complaint noticed if any.
© Clearing blockage and removal of waste materials from gully traps, connecting first manholes and sewage lines all as directed.
(d) Clearing of grass shrubs surrounding the manholes and sewage lines periodically and placing the manholes cover in position including cleaning of building roof surfaces twice during the contract period all as directed.
(e) Clearing the blockages in Nahani traps, IWC,s EWS,s WHB,s urinals to the vertical stack pipe lines etc by opening the nahani trap cover cleaning eyes of the cast iron pipes PVC pipes etc including rodding etc. as required and refixing of CI/PVC grating and cover to match with existing surfaces etc. complete all as directed.
(f) The Cleaning of man holes, sewage lines, septic tanks etc will be done in accordance with the provision of employment as manual scavengers and their rehabilitation act 2013.
Minimum number of labour required:-
Sweeper/scavanger-02 Nos per day during general shift of eight hours duration 0800 to 1700 hours including one hour lunch break.
Providing services for operation of passenger/goods lift Capacity 544 Kg/8 person capacity 01 no on all days except Sunday and holidays and including daily maintenance of lift Make: KONE ,all as specified and as directed by Engineer in Charge. Minimum no of Labour Required: Operator 01 No per day during general shift of eight hours duration 0800 to 1700 Hrs including one hour lunch break.
S&F Anti climbing device spikes type fabricated out of MS Bars (round. Square and flat ) including nuts ,bolts washres and welding in two halves made to shape to suit the cross section of the pole
Taking down old windows type air conditioner and depositing to AGE E/M store yard including doing required bricks of size 3'x1.5'x1' ft including touch up painting all as specified.
Supply and fixing post top lattern IP 65 die cast Aluminium designed with long life LED engine and Electronic driver,designed for glaire free symmetrically light distribution of capacity 70 watt cat no- TYCOONNPT70WLED757PSYMTOPC, HSN CODE 9405 of Make Havells.
Supply and fixing post top lattern IP 65 die cast Aluminium designed with long life LED engine and Electronic driver,designed for glaire free symmetrically light distribution of capacity 35 watt cat no- VICTORIAPT35WLED757PSYMTOTG, HSN CODE 9405 of Make Havells.
S&F in replacement of energy effficient LED Post top lattern with moon light effect and efficient light distribution fitting of capacity 40 Watt austhetically designed with synmetrical light distribution,IP 65 rated,spun aluminium with all accessories complete of make havells cat no LPTM-40-CDL or equivalent in Crompton/bajaj/philips
S&F in Replacement of aluminium cable lugs /Thimbles of following sizes complete all as directed.
(a) 185 Sqmm
(b) 120 Sqmm
(c) 95 Sqmm
(d) 70 Sqmm
(e) 50 Sqmm
(f) 35 Sqmm
(g) 25 Sqmm
(h) 16 Sqmm
S&F in Replacement of copper cable lugs /Thimbles of following sizes complete all as directed.
(a) 16 Sqmm
(b) 10 sqmm
(c) 6 Sqmm
(d) 4 sqmm
S&F Danger Notices plate of 1.6mm thick mild steel sheet, virterous enamelled white with letter in English, Hindi and Kannada and conventional skill and bones in signal red colour and fixed with MS clamps boltsand nuts of approved size for HT 11000Volts 25x20 cm complete all as specified and directed
S&F Danger Notices plate of 1.6mm thick mild steel sheet, virterous enamelled white with letter in English, Hindi and Kannada and conventional skill and bones in signal red colour and fixed with MS clamps boltsand nuts of approved size for LT 1100Volts 20x15 cm complete all as specified and directed
Material and labour for painting of over head RCC tank of capacity 10000 gallons ltr with two coat of external emulsion paint all as directed. (Note: for painting work all supportive items such as ladder,scaffholding, rope or any other requirement are provided by contracor.)
Supply and fix steel tubular swanged poles type 410 SP-55(11 meter long) complete with CI Base plate and finial including foundation and coping all as directed.
Supply and fix steel tubular swanged poles type 410 SP-44 (10 meter long) complete with CI Base plate and finial including foundation and coping all as directed.
Supply and fix steel tubular swanged poles type 410 SP-31 (9 meter long) complete with CI Base plate and finial including foundation and coping all as directed.
Fixing only MCCB Distribution board 6 Way of single phase including putting lugs in incoming and outgoing cables of suitable size all as directed. Note: DBs will be issued under Shedule 'B' free for fixing.
Fixing only MCCB Distribution board 8 Way of single phase including putting lugs in incoming and outgoing cables of suitable size all as directed. Note: DBs will be issued under Shedule 'B' free for fixing.
Fixing only MCCB Distribution board 12 Way of single phase including putting lugs in incoming and outgoing cables of suitable size all as directed. Note: DBs will be issued under Shedule 'B' free for fixing.
M&L for painting LT steel tublar swaged pole of any size by preparation of old aluminium paint of pole surface and applying two coat of sliver aluminium paint over a one coat of red oxide primer inculding numbering of LT Ploe No complete all as specified as directed by Eng -In Chrge.
Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor 0f sixe 6 sqmm 2 Core including gland and lugs for incoming and outgoing cales.
Supply, laying and testing cable XLPE insulated, screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor 0f sixe 10 sqmm 2 Core.including gland and lugs for incoming and outgoing cales.
Supply, Fixing and testing cable XLPE insulated on the over head tank from existing panel of height approxinmately 20 meter using clamp screened,pvc bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor 0f sixe 6 sqmm 2 Core.including gland and lugs for incoming and outgoing cables.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables / poles foundation / stay assembly and getting out in hard / dense soil all as directed by Engs-in -charge.
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point all as directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified all as directed by Engs-in -charge.
Supply and spread dry river sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed.
Supply and lay burnt brick sub class 'B' of standard size laid in trenches for cable protection all as specified and directed.
Dismantling of building security light of different capacity and supply and fixing of LED building security light of capacity 40 watt,hightly effective and efficient building light of compact size and robust design. Cat No:LSTS 40 CDL of make Crompton or equivalent in Havells/philips/bajaj/wipro.
Taking down carefully existing copper / aluminium point wiring (Concealed / surface) light/fan, socket or power complete including fittings and fixtures such as switches sockets ceiling roses pendants regulators light fittings etc removing to store for safe custody or for taking credit and making good disturbed surfaces to match with the existing surfaces complete all as specified and as directed.
Material and labour for point wiring wih PVC insulated copper stranded FRLS conductor single core cable of 1.5 sqmm size drawn throug rigid non metalic PVC conduit fixed on wall/ceiling with replacement of existing steel metal boxes with new modular metal flush boxes modular white cover plate with frame for mounting of modular switches/socket regulator and including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continious contuinity conductor and connected to earth dolly for following all as specified and as directed for light building securiy light one light point control by one 06 Amp switch.
Supply and fix modular switch 1 way 6A 1 module one way complete all as specified and as directed.
M&L for fabrication of cover protection for post top lattern fiitngs of size 1.5 'X1.5'x1.5' with angle iron frame of size 40x40 mm with steel mesh of thickness 3 mm and applying two coat of sliver aluminium paint over a one coat of red oxide primer complete all as specified.
Supply in replacement of outdoor type FRP Junction box light weight suitable for pole mounting including,bus bar-04 No and MCB 6 Amp SP flat iron clamp duly painted with two coats of aluminium paint over a coat of red oxide primer and GI Nuts and bolts washers and necessary connectors for loop in loop out cable and suitable size gland all as directed and specified.
Supply and fix in replacement solar LED panel IP-55 of capacity 20 watt,solar panel configuration 1280 wp PV Module of Make TATA BP solar all as specified.
Supply and fix analog time switch 250 volts single phase 20 amps rating with contractor fittings inside steel enclosure. Make L&T
Supply and fix in replacement suspended architectural LED luminairs provided soft-light and glaire free symetrical illumination with continuous monting end cap capacity 20 watts. Cat no: CONSTA 1144 LP 20 WLED 857 SPCWH CODE 9405 OF Make Havells
Supply and fix in replacement of LED 40 watt,240 volts mounting on 60 mm outer diameter pipe (OD pipe) Aviation/obstruction light fittings make Bajaj cat no.110731 Item Code 50802690BAJ colour Red.
S&F in replcament of energy effficient LED post top lamp ideal to lit up park,gardens ways,fitting of capacity 20 Watt austhetically designed with synmetrical light distribution,IP 65 rated,spun aluminium with all accessories complete of make Crompton cat no LPTH-20-WW or equivalent in havells/bajaj/philips including making platform of size 1.5'X1.5'x1.5' including supplying and fixing of FRP junction box of suitable size which can accomodate 04 no of bus bar and MCB of capacity 6 Amps all as specified.
S & F on load change over switch 415 volts in sheet metal encloser of thickness 2.5 mm ,4 pole of capacity 160 Amps.
S & F on load change over switch 415 volts in sheet metal encloser of thickness 2.5 mm ,4 pole of capacity 400 Amps.
Material and labour for painting of LT feeder pillar box external/internal surfaces indoor/outdoor type of any size with two coat of synthetic enamel paint of approved quality and colour after cleaning and removing the rusted area using sand paper complete all as specified and directed
Earthing complete with GI earth plate electrode 60cmx60xcmx6mm size buried directly in ground with bottom edge of the plate not less than 2.25 meters below normal ground level and connected to GI earth strip of size 25x4mm as earth strip by means of nuts bolts etc with and including necessary excavation, earth chamber with plain cement concrete 1:3:6 type C-1, necessary RCC chamber cover in cement concrete 1:2:4 with nominal reinforcement, funnel etc., all as shown in electrical plate No.3 of SSR Part I connected to earthing test point including testing on completion all as specified and as directed.
Supply and lay HT UG cable 11000 Volt grade aluminium conductor 3 core XLPE insulated suitable for earthed system of size 185 Sqmm complete all as specified and as directed.
Suply and laying of stone aggregate 40 mm in four pole structucture for current leakage protection.
Suply and lay fine aggregate cushion filling, spreding and laying in layers,in four pole structucture for current leakage protection.
Mandhara Associates
M/s H S VISWANATH CONSTRUCTIONS
eurekaenterprises
ANAND REFRIGERATION
B5BUILDING SOLUTIONS
Lucky Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .