Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.0 Cr+₹59,910.60 (0.30%)Rejected-Finance | ₹2.0 Cr+₹59,910.60 (0.30%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹2.7 Cr+₹76.6 L (38.8%)Rejected-Finance | ₹2.7 Cr+₹76.6 L (38.8%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹3.2 Cr+₹1.2 Cr (60.2%)Rejected-Finance | ₹3.2 Cr+₹1.2 Cr (60.2%) | L4 | Rejected-Finance Being not L1 |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
17 Nov 2022, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
ADDN ALTN TO MAIN PARADE GROUND AT ATS BELAGAVI
2022_MES_557071_1
81203/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Sambra Belgaum
As Per Tender Documents
7 documents required · 7 mandatory
₹1,000
GE (AF) Sambra
₹3.0 L
29 Nov 2022
11 Oct 2022
19 Nov 2022
11 Oct 2022
17 Nov 2022
5 Nov 2022
11 Oct 2022 - 25 Oct 2022
Amount
Repair to pot holes of any depth, not exc 1 Sqm each including, sweeping free from, dust and mud, or water scoring sunken surfaces in roads, paths etc cutting around edges at least 25 mm in depth and making good by filling screened and graded road metal and well ramming (including supply of raod metal) etc complete all as specified and as directed.
Preparing Black top surfaces by brushing with steel wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surfaces with gunny bags / air compresser to remove all loose dirt etc complete all as specified and as directed by Engr-in-Charge.
Material and labour applying evenly a tack coat with bituminous primer @ 5 Kgs per 10 Sqm using paving bitumen of grade VG-30 over prepared surface by mechanical sprayer etc complete all as specified and as directed.
Material and labour premixed bituminous macadam laid, rolled and compacted to required gradient and camber (Consolidated thickness 75 mm or less), by using 4% bitumen content any penetration using paving bitumen of grade VG-30 (confirming to IS-73-2006) etc complete all as specified and directed.
Material and labour for bituminous premix semi dense asphaltic concrete (SDAC), 40 mm thick (Consolidated average thickness) in single layer using paving bitumen of grade VG 30 with 5.5% binder content, mixed in hot mix plant and compacted with using 8 to 10 tonnes cap vibratory power road roller to achive the required compactness, camber and gradient finished complete including (Cutting of edges of roads straight and site clearance) etc all as specified and as directed by Engr-in-Charge.
Note :-Semi dense asphaltic concrete shall be laid on the same day over bituminous macadam. Contractor shall be planned the work accordingly.
Material and labour for two coats of painting on road surfaces Painting lines, dashes, arrows, letters, etc. on roads, pavements and the like exc 10cm wide with road marking paint, of blue or as directed, including cleaning the surface by brushing/sweeping by brooms to remove all dirts, scales of oil, grease and foreign materials etc complete all as specified and directed.
Material and labour for bituminous surfaces of road marking 2.5 mm thick centre lines, stop lines, dashes, arrows etc. and the like not exc 10cm wide on road pavements with hot applied thermoplastic road marking paint of approved colour conforming to BS3262-1989 with special applicator machine all as per manufacturer instructions complete all as specified and directed.
Surface excavation n exc 30cm deep and avg 15cm deep and getting out in hard/dense soil.
M & L broken stone or boulder hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified
M&L for 100mm thick PCC 1: 4:8 type D2 using 40mm graded stone aggregate as in sub base of flooring
M & L machine pressed precast concrete interlocking paver block, any size / shape and size conforming to IS 15658-2006 of 60mm thickness, M-25 Grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc. made by table vibratery method using, laid over 50mm thick compacted bed of fine sand, compacting and properly embedding / laying of interlocking paver blocks in to the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50 m and depositing where directed at a level not exceeding .50 m above the starting point.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curveture, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not be more than 5 mm), including making drainage opening wherever required complete.
Excavation in trenches n. exc. 1.50m wide and n exc 1.5 m in depth; for foundation etc.; or for shafts, wells, cesspits, manholes, pier holes, poles, stays etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil.
Returning,filling including, spreading, levelling , watering and well ramming inlayers not exceeding 25 cm in any type of soil.
M & L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations,filling in poles and mass concrete.
Material and labour for pre-cast cement concrete block masonry with solid blocks,in PCC 1:3:6,Type C1,using 20mm graded stone aggregate,exc 10cm in width and setting in CM 1:4
M & L for Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping including weathering slightly rounded or chamfered angles and throating and including necessary use and waste of form work.
M & L rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement.
M & L for pre cast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slab set in cement mortar 1:4. NOTE: Reinforcement shall be measured and paid separately.
M & L for mild steel TMT bars of 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No.21 here-in-before but 10mm dia and over bars for handles conforming to Fe290Gde E-165
M & L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of 150mm bore after they are laid and tested.
M & L Re-inforced concrete pipes of 150mm dia of class NP-2 laid and jointed complete with collars
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
Cutting exising manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 300mm bore including packing under and completely surrounding pipes with concrete after they are laid and tested .
M & L Re-inforced concrete pipe of 300mm dia of class NP-2 laid and jointed complete with collars
Demolition of brickwork or stone/boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) as directed.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
M & L for rendering 10 mm thick in CM 1:4 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement
M & L 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete.
M & L for painting steel and iron work of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide (Zinc chrome) primer on new steel surfaces including prepration.
M & L for RCC 1:1.5:3 using 20mm graded stone aggregateas in cloumn footings/plinth beams etc
M & L for RCC 1:1.5:3 using 20mm graded stone aggregateas in columns etc
M & L for mild steel TMT bars of 5mm and over upto and including 10mm as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F framed work as in doors or gates of angles or other section with gusset plats, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running, rails and guiedes) and hanging; also fastening and fixing complete.
Excavation over areas not exceeding 1.5m deep and getting out in hard/dense soil.
Excavation over areas exceeding 1.50m deep and not exc 3.00m deep and getting out in hard/dense soil.
Excavation over areas exceeding 3.00 m deep and not exc 4.50m deep and getting out in hard/dense soil
Material and labour for pre-cast cement concrete block masonry with solid blocks type C1, PCC 1:3:6, using 20mm graded stone aggregate, exc 10cm in width and setting in CM 1:6 complete all as specified and as directed.
M & L for rendering 15mm thick in cement mortar 1:6 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement
M & L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping including necessary form work all as directed.
M & L for Fine aggregate (Sand) for filling in pits all as specified and as directed
M & L for Medium sand for filling in pits all as specified and as directed
M & L for Coarse sand for filling in bore holes/pits all as specified and as directed
M & L for Graded coarse aggregate (stone) of 20 mm size for filling in pits all as specified and as directed
M & L for Broken stone aggregate for loose filling of gauge 40mm size for filling in pits all as directed.
M & L for Broken stone aggregate for loose filling in pits of gauge 80 to150mm size hand packed tightly all as directed.
Removing excavated surplus soil to a distance exceeding 250m and upto total distance of 1.50km and depositing where directed.
M&L for RCC (nominal mix), type B1 1:2:4 (20mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc.; and mass concrete complete all as specified and directed.
M&L for RCC (nominal mix), type B1 1:2:4 (20mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
Spreading and levelling of soil obtained from excavation in layers n exc. 25cm thick in floor, well ramming including watering as required complete all as specified and as directed.
M & L RCC (nominal Mix) type B-1, 1:2:4 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.50m clear span all as directed.
Use and waste of formwork for rough finished flat surface of concrete, sides of concrete foundation, footings and Plinth beams; and similar work complete
Use and waste of formwork for rough finished flat surface, sides of pillars, posts, struts, piers,and columns complete
Use and waste of formwork for rough finished flat surface, sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams complete all as specified and directed.
M & L reinforced cement concrete (nominal mix) type B1 1:2:4 (20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste formwork to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or slopping) for flat, rough finished surfaces of concrete complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail?ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed.
M&L for rendering 5 mm thick on brick work or concrete surface in CM 1:3 for ceiling finished even & smooth without using extra cement all as specified and directed.
M & L rendering 10mm thick in CM 1:3, mixed with water proofing compound 100 ML per bag of cement as specified by manufacturer instruction on concrete surfaces of roof and making the surfaces finished fair and even as in required slope for draining out the rain water all as specified and directed. Note - WPC measured and paid for separately
Supply only liquid water proofing compound
Material and labour APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including aluminium painting over membrane complete all as specified.
M&L preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified.
Material & Labour for applying Two coats of acrylic emulsion paint of Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives over and including priming coat of exterior primer applied on new plastered surfaces of walls complete as mentioned in SSR all as specified and as directed .
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified.
M&L 75mm thick cement concrete, type D2 1:4:8 using 40mm stone agg as in sub base under floor complete all as specified.
M&L 25mm thick cement concrete, type B1 1:2:4 using 20mm stone agg as in floor complete all as specified.
M&L PCC 1:3:6 type C1 using 20mm stone agg as in plinth protection (75mm thick) including finished even and fair w/o using extra cement and all necessary formwork complete all as specified and directed.
M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete
Material and labour for Non skid ceramic tiles, coloured, 7 to 8mm thick (square or rectangular), area of each tile exc 0.06 sqm but not exc 0.11 sqm, set and jointed in neat cement slurry and pointed in white cement with pigment to match, as in floors over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles in verticle surface, 450X350X7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 10mm thick backing coat in cement mortar 1:4, all as specified and directed.
M&l for machine cut cudappah stone slab 20-25mm thick fixed to wall independantly as urinal partition, cutting grooves in wall and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for rounding to edges of cudappa stone slabs one edge, such as in steps, cooking platform and other similar situations complete
Supply & fix Vitreous China Urinal, Half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement flush pipe, grating and union for discharge pipe complete all as specified and as directed.
Supply & fix Urinal spreader of PTMT any colour for fixing with 15mm dia pipe. (minimum weight 60gms) complete
Supply & fix Vitreous Cliina wash basin, white, flat back, size 550x400mm, including cutting for and pinning in ends of brackets or errecting stand waste fitting and union, plugs and chain and connecting upto supply pipes complete all as specified and as directed.
S&F Pillar taps, 15mm dia, cast copper alloy, with capstan heads, chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed complete.
S&F PVC connection 15mm size with PTMT nuts of length 600mm
S&f Angle stop valve 15mm dia of PTMT any colour high pressure screwed for iron pipe and fixed complete
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed in wall/ floor with necessary clamping as required complete all as specified and directed.
S&F 50mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf / Sq cm fixed to wall, ceiling or in floor complete all as specified and directed.
S&F 75mm PVC (SWR) junction single (Single T) equal or unequal complete all as specified and directed.
S & F PVC bends for 75 mm bore pipe complete all as specified and directed.
S & F (SWR) floor trap 75 mm dia, plain with grating including jointing with solvent cement all as specified and directed
S&F PVC (SWR) vent cawl 75mm dia complete
Supply, Hoisting and fixing 1000 Ltr capacity rotational moulded polyethylene water storage tank cylinderical vertical with closed top hoisted and fixed in position all as specified in SSR part I complete all as specified.
S & F Unplasticised PVC pipes 25mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including all fitting such as bends,elbows, tees tank connector etc
S & F Unplasticised PVC pipes 15mm dia of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including all fitting such as bends,elbows, tees tank connector etc
S&f stop valve 15mm dia of PTMT any colour high pressure screwed for iron pipe and fixed complete
S&F ball valves for 25mm dia pipe, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicityindex of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F 100 mm long butt hinges medium weight cold rolled to door frame with necessary screwing or bolting complete.
S&F 150 mm long aluminium anodised handle fabricated type.
S&F 150 mm long aluminium anodised barrel tower bolt .
M/L for 300 mm Aluminium alloy, anodised sliding door bolt with hasp and stapple bolt type.
Supply and fix Steel ventilators with top hung shutters including hinges, handle and steel peg stay, complete all as specified and directed
S&F 3 mm thick figured glass pin head type and glazing with oil putty in square n. exc 0.5 sqm in each pane.
M&L for sub main wiring for controlling of light/5 Amps Switch Socket combination two single core FRLS PVC insulated and unsheathed cables with copper conductor 1100V grade, 1.5 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed up walls, roofs or floors including one run of 1.5 sqmm FRLS PVC insulated and unsheathed cable and connecting up complete all as specified and directed. Note:- Three runs of 1.5 sqmm copper conductor and one run of PVC casing and capping / PVC conduit shall be measured as one length.
M&L for sub main wiring for controlling of 15 A Switch Socket combination two single core FRLS PVC insulated and unsheathed cables with copper conductor 1100V grade, 2.5 sq mm drawn through and including suitable size of non-metallic PVC rigid conduit and conduit accessories / casing and capping fixed up walls, roofs, or floors including one run of 2.5 sqmm FRLS PVC insulated and unsheathed cable and connecting up complete all as specified and directed. Note:- Three runs of 2.5 sqmm copper conductor and one run of PVC casing and capping / PVC conduit shall be measured as one length.
Supply and fix switch socket combination 2/3 pin 5 Amps flush type
Supply and fix switch socket combination multipurpose 2 in 1, 3 pin 5 /15 Amps universal type controlled by one switch
Supply and fix Ceiling rose, 3 phase/PVC/polycarbonate, isolated bodysurface type PVC, 50x25mm, three terminals complete all as specified and as directed.
Supply and fix single door DB 04 way SPN with 200 Amps rated bus bar 240 Volts complete all as specified and as directed.
Supply and fix MCB Single pole, 240 volts 6 to 32 Amps 10 KA rupturing capacity complete all as specified and as directed.
Supply and fix MCB Single pole & neutral 240 volts 6 to 32 Amps, 10KA rupturing capacity complete all as specified and as directed.
M&L complete for switch piano flush button single pole one way 5 Amp 240 V
Supply and Fix REGAL Batten for LED tube with single LED Lamp 1x 20 w, Ultra bright glass LED Tubelight with very high efficacy suited for installation in T8 fitting with lamp holders etc. complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size all as directed Make & Model No for Batten : Havells Cat No REGALBATTENT 8UPTO1X22WDSBSWH and LED Lamp Havells Cat No CRYSTEL 1213T8DSTL20WLED865SGLASS or equivellent model of other Make.
M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 5 of SSR Part-I and testing on completion.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm x 4 core.
Supply and fix Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 and finial including foundation and coping.
Supply and fix FRP Cable loop in loop out box 250 x 200 x 105 with 3 Phase 4 wires connector and 1 No of MCB, SP 6-32 Amps including necessary fixing arrengements with clamps fabricated out of Flat Iron of 20x3 mm including nuts, bolts and washers on poles complete all as specified and as directed.
Supply and fix wiring with three core 1.5 Sqmm PVC insulated FRLS cable with multistranded copper conductor, 1100 volts grade drawn through PVC conduit of suitable size but not less than 25mm dia for electric connection from loop in loop out box to street light fittings all as specified and directed. Note:- PVC conduit will be measured and paid seperately.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint.
S & F timelite distribution board of 16 A 3 pole/230 V Analog time switch all as per Cat Part No TL016AB0 of Indoasian Make.
M & L for LT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggregate (30 x 30 x 45mm) at approx distance 100 mtr including necessary earth work complete all as specified and directed by Engr-in-Charge.
S & F energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 flood light, 240 Watt suitable for high mast application, highlighting architectural facade and general purpose lighting. Make:- Havells Cat No - JETA VALOURFL240WLED757MODWBLT G & ASSEMBLEDCGBOXVALOUR240WAP or other equivalent make.
Excavation in trenches n. exc. 1.50m wide and exc 1.5 m and not exc 3m in depth; for foundation etc.; or for shafts, wells, cesspits, manholes, pier holes, poles, stays etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil.
Supply and spread river sand for cable cushioning in trenches all as specified in clause 19.75 of SSR Part-I.
Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 1.5 wide and 1.5m in depth and getting out all as directed including filing back and finishing it with PCC complete matching with the surroundings.
M&L for GI pipes light grade galvanised with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors of 40 MM dia.
M & L for providing PCC 1:3:6 type C1 (using 20mm graded curssed stone aggregate) as in pillars, platform, beds and copping around poles etc complete incl necessary form works and finishing the exposed surfaces even and smooth without using extra cement all as specified and as directed.
M & L for providing PCC 1:2:4 type B1 (using 20mm graded curssed stone aggregate) as in copping around poles etc complete incl necessary form works and finishing the exposed surfaces even and smooth without using extra cement all as specified and as directed.
Cutting the existing GI pipe lines upto 100 mm dia for insertion of 'T' including supply and fixing of 'T' of size 100x100x50 mm dia complete all as specified and directed. Note :- Rate includes for excavation & earth work.
Supply and laying galvanized iron tubing, “Medium grade” 50mm dia laid in trenches with all fitting all as specified and directed.
Supply and laying galvanized iron tubing, “Medium grade” 25mm dia laid in trenches with all fitting all as specified and directed.
Supply & fix Gun Metal Gate valve of size 50mm dia, with iron wheel head, screwed both ends for iron pipes all as specified and directed.
Construction of valve chamber of size 600x600x600mm internal size suitable for valves with PCC 1:4:8 type D2 foundation and brick wall in cement mortar 1:4 PCC 1:2:4 type B1 for coping rendering in CM (1:6) 15mm thick including provn of mild steel sheet cover 3.15mm thick on 40x40x6mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrrangement including necessary excavation earth work all as specified and directed.
KAJAL CONST.
Vinayaka Enterprises
ASSOCIATED ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .