Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40,404Admitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹42,841+₹2,437 (6.03%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹43,051+₹2,647 (6.55%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S JITENDRA KUMAR L3 | SANJAY ELECTRICALS L2 | M/S S K ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00Safe carriage of following materials from Store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work as per RESPO Norms. | ||||||
| 1.01 | 11/0.4 KV T/F 250 KVA | 5 | No. | - | - | - |
| 1.02 | LT PVC Cable AL 3.5X400 Sq.mm. | 45 | Mtr. | - | - | - |
| 2.00Supply & Erection work of following materials:- | ||||||
| 2.01 | Henley Type Tailless Unit Protection Cubical Pannal 500 Amp. 650 V for 250 KVA DT | 5 | No. | 31,390 ₹36,500 | 31,500 ₹36,601 | 30,000 ₹35,001 Lowest |
| 2.02 | Copper L-Piece 50x225x10 mm (LS) | 20 | No. | 2,650 ₹3,178 | 2,500 ₹3,022 | 2,000 ₹2,501 Lowest |
| 2.03 | Copper L-Piece 62x225x12 mm (LS) | 20 | No. | 2,650 ₹3,177 | 2,500 ₹3,022 | 2,200 ₹2,701 Lowest |
| 2.04 | AL Leg long barrel off size (LS) | 40 | No. | 135 ₹196 Lowest | 140 ₹196 Lowest | 150 ₹201 |
| 3.00 | Body and neutral earthing of 250 KVA distribution Transformers installed by digging of pit up to water level depth (approx. 100’) and then inserting 1-1/4" dia G.I. pipe of "B" grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 50x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer including the cost of arrangement of all material, labourer, T&P, carrier etc. required for proper completion of work. | 10 | No. | - | - | - |
| 4.00 | Construction of 250 KVA distribution Transformers of Plinth of size 5’x5x4’ above ground level and one ft. below the ground level of 9”. After excavation of 4” earth, brick ballast shall be provided and rammering will be done properly after that a retaining wall of 9” width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. After this brick ballast shall be provided up to 6” from the earth level and proper rammering shall be done. One No. jall of 12 mm M.S. tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement, sand and stone ballast shall be laid on the top of the Plinth. The 12 mm thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervising Engineer. It including the cost of all material, labour T&P, carrier etc. required for proper completion of work. | 5 | No. | - | - | - |
Tender Value
₹8.3 L
EMD Value
₹8,500
Closing Date
19 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-I ALIGARH
LAL DIGGI ALIGARH
EDCA-23/2025-26
2025_DVVNL_1068821_1
EDCA-23/2025-26
Open Tender
Electrical Works
Turn-key
30 days
EDC-I ALIGARH
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DVVNL WEBSITE
₹8,500
24 Sept 2025
27 Aug 2025
19 Sept 2025
27 Aug 2025
19 Sept 2025
27 Aug 2025
Amount
Safe carriage of following materials from Store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work as per RESPO Norms.
11/0.4 KV T/F 250 KVA
LT PVC Cable AL 3.5X400 Sq.mm.
Supply & Erection work of following materials:-
Henley Type Tailless Unit Protection Cubical Pannal 500 Amp. 650 V for 250 KVA DT
Copper L-Piece 50x225x10 mm (LS)
Copper L-Piece 62x225x12 mm (LS)
AL Leg long barrel off size (LS)
Body and neutral earthing of 250 KVA distribution Transformers installed by digging of pit up to water level depth (approx. 100’) and then inserting 1-1/4" dia G.I. pipe of "B" grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 50x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer including the cost of arrangement of all material, labourer, T&P, carrier etc. required for proper completion of work.
Construction of 250 KVA distribution Transformers of Plinth of size 5’x5x4’ above ground level and one ft. below the ground level of 9”. After excavation of 4” earth, brick ballast shall be provided and rammering will be done properly after that a retaining wall of 9” width by first class brick in ratio 1:4 of cement and sand shall be made. The earth shall be filled up to one ft. below the top of the plinth. After this brick ballast shall be provided up to 6” from the earth level and proper rammering shall be done. One No. jall of 12 mm M.S. tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement, sand and stone ballast shall be laid on the top of the Plinth. The 12 mm thick plastering shall be done all around the plinth in 1:4 ratio of cement and sand. The contractor shall be responsible to complete the work as per direction of Supervising Engineer. It including the cost of all material, labour T&P, carrier etc. required for proper completion of work.
FABRICATION & ERECTION OF FENCING AND CONSTRUCTION OF RETAINING WALL AROUND OF 250 KVA TRANSFORMERS. The complete 11/0.4 KV Substation shall be provided with two meter height fencing and retaining wall around the substation. One No. Gate with proper locking arrangement for entry of personnel shall also be provided. The fencing shall be made of 50x25 mm x10 SWG rectangular welded mesh of wire mesh in length. Wire mesh shall be fixed on panels made of 50x50x6 mm M.S. Angle. The wire mesh on panels will be supported by 25x3 mm M.S. flat on all the bracings diagonally and 50x6 M.S. Flat horizontally at the center of the panel. The panel will be joined by bolts & nuts of appropriate size with each other and on the main support on corners including supply of all material, labour, carrier and T & P etc. required for proper completion of work. The painting of complete fencing shall also be done with one coat of red oxide primer and two coat of synthetic green paint. For construction of retaining wall around the fencing, excavation of earth shall be done in foundation in ordinary soil including disposal of surplus earth at some suitable distance. The dimension of excavation shall be 1m wide, 0.45 m deep and suitable length as per wire mesh. After excavation of earth a cement concreted pad shall be laid in foundation. Concreting shall be done with Ist class brick ballast, coarse sand and cement in proportion of 8:4:1. First class brickwork shall also be done in foundation and super structure in 1:6 Cement and coarse sand including necessary cutting and moulding of bricks in foundation depth of wall 0.30 m, thickness of wall 0.35 m & superstructure brick work thickness of wall 0.23 m & depths 0.30 m including supply of all material, labour, carrier and T & P etc. required for proper completion of work.
Dismantling and removal of existing following materials from the various area preparing their coils and then stacking in the respective JE’s (Store) as per direction of Supervising Engineer. It includes the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
100 KVA Transformer
SANJAY ELECTRICALS (BID ID -5544924)
M/S JITENDRA KUMAR (BID ID -5545161)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .