Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹22.1 L+₹44,786.50 (2.07%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
3 Dec 2022, 6:00 pmClosed
GE(I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF CERTAIN E/M WORKS AT BANIHAL AND PATNITOP UNDER GE (I) 873 EWS.
2022_MES_560757_1
NIT-59 of 22-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE(I) 873 EWS
₹42,000
Yes
30 Dec 2022
1 Nov 2022
6 Dec 2022
1 Nov 2022
3 Dec 2022
19 Nov 2022
Amount
Material and labour for disconnecting electrical connections of 100KVA transformer, removing the transformer from two pole structure or platform, loading and shifting to its new location within a radius of 1.5 Km and reinstalling the same on platform or two pole structure including making all electrical connections, complete all as specified and as directed.
Material and labour for disconnecting electrical connections of 11 KV CT/PT unit of ratio 5/5 A and shifting to its new location within a radius of 1.5 Km and reinstalling the same including making all electrical connections, complete all as specified and as directed.
Dismantling of concrete LT/HT poles/struts of any description in any position, complete all as specified & directed.
Dismantling of cross arms of MS channel or angle iron etc., complete all as specified & directed.
Dismantling of insulators of any type, shape & size, complete all as specified & directed.
Dismantling of stay assembly complete any type, complete all as specified & directed.
Dismantling of air break gang operated switch, vertical/horizontal mounted including insulators and operating mechanism, complete all as specified & directed.
Dismantling of ACSR conductor of any type & size from over head line or HT/LT poles, complete all as specified & directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete all as specified and as directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer complete all as specified and as directed.
Lightning arrestor non-liner type conforming to IS-3070 Part I complete with all fittings, transmission class discharge capacity 10 KA suitable for 11KV including making connections with overhead line with ACSR conductor, complete all as specified and directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) of any size for HT/LT lines on steel tubular/PCC poles, stretching without kinks and bends including binding wire complete , complete all as specified.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade including taking down old unserviceable insulator complete complete all as specified and directed.
Pin type porcelain in replacement, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Stay Assembly using stay rod of 20mm dia complete accessories as shown in Electrical Plate No 1 of SSR 2009 Part-I such as loop type insulator, porcelain, vitreous white/ brown or green, large size with overall dimensions 90 x 140mm clearance of hole 16mm, stay wire of size 7/4mm etc., including taking down old, complete all as specified and directed. Note: Excavation and concrete shall be measured and paid separately.
Air break, gang operated tripple pole mounted with 15 Nos insulators outdoor type, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assemble, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assembly of phases fuses etc conforming to IS : 1018 of 1972 with continuous current rating with 15 insulators of current rating upto 400 amps 11000 volts grade, complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and including test point made of GI strip 40x8mm and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Galvanised Iron earthing strip 32 x 6 mm from earth test point to electrical equipment complete all as specified and directed
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron and including test point made of GI strip 40x8mm including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Galvanised Iron earth wire 4 Sqmm from earth test point to electrical equipment including taking down old unserviceable earth wire complete all as specified and directed
Earthing complete with galvanized steel pipe electrode 40mm bore, medium grade buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.25 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron and including test point made of GI strip 40x8mm including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 2 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Cable Jointing Kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50-95 Sqmm including testing and commissioning, including taking down old unserviceable kit complete all as specified and directed
Cable Jointing Kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-120 Sqmm including testing and commissioning, including taking down old unserviceable kit complete all as specified and directed
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 95 Sqmm 3 core, including taking down old unserviceable cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 95 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core, including taking down old unserviceable cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 4 core, including taking down old unserviceable cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 4 core, including taking down old unserviceable cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core, including taking down old unserviceable cable, complete all as specified and as directed.
Arial Bunched Cable (ABC) 11 KV grade, stranded and compact aluminium phase conductor of size 3 Core x 95 Sqmm and 1 Core x 70 Sqmm bare messenger conductor with alumnium alloy. The phase conductor should be insulated with XLPE sioplas compound as per IS:14225-1995 Part-II complete all as specified and as directed. Note : The contractor shall provide the fittings required viz. Dead End clamp, Suspension clamp, I Hook, Loop Holder, Pulley Realy, Dead end Anchor clamp) anchor clamps, suspension clamps, in-line connectors, service clamps, insulation piercing connectors and tapping from bare line etc. all as directed at site. The Quoted Rate shall be deemed to be inclusive of this provision.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Laying only serviceable bricks as mechanical protection to underground cable with width equal to length of bricks, width of brick perpendicular to length of cable, all as specified and as directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Material and labour for construction of Platform suitable for 63/100 KVA transformer of size 3m x 3m with 1.50m clear height from ground level, 1.00m deep foundation, 150 mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation below ground level, 23cm wide brick masonry in CM 1:6 below & above ground level, hollow space to be filled hard core of size not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15cm thickness, watered and well rammed with 100mm thick cement concreate 1:2:4 type B-2 as in Floor/Top of platform, brick surfaces plastered in CM 1:4 including protection with XPM, gate and chain link fencing rail around the platform with angle iron of 40 x 40 x 6mm frame upto 1.20m clear height supports grouted in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in foundation of angle iron including excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50m, complete all as specified and directed
Material and labour for construction of Platform suitable for 63/100 KVA transformer of size 2.5m x 2.5m with 1.00m clear height from ground level, 1.00m deep foundation, 150 mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation below ground level, 23cm wide brick masonry in CM 1:6 below & above ground level, hollow space to be filled hard core of size not exceeding 63 mm, deposited spread and levelled in layers not exceeding 15cm thickness, watered and well rammed with 100mm thick cement concreate 1:2:4 type B-2 as in Floor/Top of platform, brick surfaces plastered in CM 1:4 including protection with XPM, gate and chain link fencing rail around the platform with angle iron of 40 x 40 x 6mm frame upto 1.20m clear height supports grouted in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in foundation of angle iron including excavation in any type of soil, returning filling in and removal of surplus soil to a distance 50m, complete all as specified and directed
Cable route marker with route indication on cast iron disc of 150mm dia and 10mm thick, marked/written for "LT cable 1100 VOLTS" embosed including indication direction fixed/ bolted to 40mmx40mmx6mm thick MS angle iron support of 0.50m long embedded upto 200mm depth in concrete block of size 200mmx200mmx50omm casted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surfaces, complete all as specified and as directed.
Bus bar panel size 0.8x0.4x0.4 Mtr, KISOK, outdoor type, CRPI tested, LT 440 Volts, 50 Hz, 3 phase 4 wire supply, comprising of bus bas chamber with 4 Nos aluminium strip bus bars PVC insulated with colour coding of rating 200A, floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 1.4 thick MS sheet CRCA on angle iron 30x30x4mm frame with front opening doors, locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufactures in PCC 1:3:6 type C-1, using 20 mm graded crushed stone aggregate as directed by the Engr-in-Charge including earth work complete all as specified.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 10 Sqmm twin core cable flat or circular, complete all as specified.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 16 Sqmm twin core cable flat or circular, complete all as specified.
Street Light fitting 35 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device all as specified and as directed. Make : Havells Model Endura Citylite Platinum Plus or equivalent in Wipro / Philips / Crompton
1.5 Sqmm, 3 core PVC insulated, unsheathed FRLS copper cable for connection of security lights/ indication lights all as specified and directed by Engr-in-charge.
Shackle type insulator porcelain vitreous white, brown or green 75mm high and 90mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x3mm size, 12mm dia insulator bolts, washers and nuts , complete all as specified.
On load change over switch of 63 Amps, side handle operated, 4 pole, 415 Volts including taking down old unserviceable switch, complete all as specified and as directed.
On load change over switch of 100 Amps, side handle operated, 4 pole, 415 Volts including taking down old unserviceable switch, complete all as specified and as directed.
Supply installation, testing and commissioning of electronic meters tamper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, a, 50 Hz, conforming to IS 13779, IP-54 with parameteers to show data, time, current reading, load, PF, coltage and KWH, complete all as specified and directed. Make : L & T/Secure/Siemens /ABB / Legrand
Supply installation, testing and commissioning of 11 KVA (HT) Trivector Meter complete with required wiring system from metre to CT & PT, complete all as specified and directed. Make : L & T Model No. ER300P Class 0.5 (Base mounting), Three Phase, 4W TVN 110 Volt (L-L) 1A class 0.5S BM (WR300BB 1200) or equivalent in Siemens /ABB / Legrand
Supply, installation, testing and commissioning sheet metal enclosure out door type, weather proof for energy meter, factory fabricated of 3.15mm thick CRCA sheet, compartmentalised design suitable for for down loadinf data from meter to AMRI without opening panel with suitable locking arrangement, of size not less than 0.45x0.35x0.30 metre including suitable clamp fitted to poles as required at site or as directed.
Supply, installation, testing and commissioning sheet metal enclosure out door type, weather proof for energy meter, factory fabricated of 3.15mm thick CRCA sheet, compartmentalised design suitable for for down loading data from meter to AMRI without opening panel with suitable locking arrangement, of size not less than 1.00x0.60x0.45 metre including mild steel channel frame of ISMC-75 at the base of panel for grouting purpose and grounted in and including suitable foundation in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate, complete all as specified and as directed.
Danger notice plate of size 25 x 20 cm, made of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with and including mild steel clamps, bolts and nuts of approved size for HT poles, complete all as specified.
Connection cable from CT/PT Unit to trivector meter with PVC insulated unsheathed FRLS copper cable of size 1.5sqmm x 10 core, complete all as specified and as directed.
Supply and fixing 11KV CTPT metering unit, outdoor type, oil cooled, pole mounted, CT Ratio 5/5 Amp, Burden 10VA, class-0.5 S, STC-3 KA/1 Sec and PT Ratio 11KV/110V, Burden 0.5VA, class-0.5 S, insulation-12KV/28KV all as per IS 2705/1992 and IS 3156/1992 complete all as specified and as directed.
Supplying, installing, designing, testing and commissioning of feeder pillar box, KIOSK, outdoor type, CPRI type tested, LT 440 Volts, 50 Hz, 3 Phase 4 wire supply, floor mounted factory fabricated weather and vermin proof protection class IP 54 made out of 3.15 mm thick MS Sheet CRCA on angle iron 40X40X6mm frame of size and size of panel (1.5 (H) x 1.0 (L) x 0.6 (W) mtr) suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally, shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 type C-1 , using 20 mm graded crushed stone aggregate as recommended by manufacturer or directed by the Engr -in - charge including earth work complete comprising of following :
Incoming (a) Bus bar chamber comprising 4 Nos copper strip of size 50 x 5 mm . PVC sheathed with colour coding. (b) MCCB having current ratings 250 Amps with rupturing cap 36 KA , AC 415 Volts four pole with microprocessor release complete with spreader links. - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, including suitable CTs with secondary current 5A, with display volt, Amp , Frequency, KWH. - 01 No (B) Outgoing (a) MCCB having current ratings 160 Amps with rupturing cap 25 KA , AC 415 Volts four pole with thermal magnetic release complete with spreader links. - 03 Nos. (b) All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice and required at site and suitable foundation for panel as per manufacturer recommendation.
Notes for Serial Item No 63 1. The drawing for LT Feeder Pillar Box shall be got approved by the Engineer-in-Charge. 2. The Pre-dispatch inspection of LT Feeder Pillar Box shall be done by the Rep of the Accepting Officer at factory site. 3. All the existing cables shall be fixed with glands, lugs etc. of the requisite size. Makes for Serial Item No 63 : Make of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear Make of MCCB & Star Delta Starter : L&T / Legrand / Schneider / Havells Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO Contactor : SECURE / L&T / ABB / SCHENEIDER / SEIMENS / LEGRAND / AE
Surface Excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 cum, in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed.
Steel work in tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 all as specified and directed.
Plain cement concrete 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified.
Mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, square / rectangle sections, channel or flat section) including distance pieces, cleats etc. confirming to grade FE 410-0 complete all as specified and directed.
Mild steel plates (plain or chequered) channel, square cut or notched (Ordinary and counter sunk) forming holes, without any attachment as in gusset plates all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed with self taping screws, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering / cladding to wall, fixed with self taping screws, complete all as specified and directed.
Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long, diameter of neck in exc 12mm but n exc 20mm, complete all as specified.
Mild steel rolled work as in doors or gates of angle or other section with gusset plates, rails, braces, eaves board etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified and directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
M/S Builders Indias
Bidder Name
SWASTIK TRADERS
M/S Builders Indias
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .