Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
1 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SOUTH
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N OR 'V' Whichever is less; where. V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per ANNEXURE-XXXIII, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Trenching,Cable laying,Location and /or signal foundation/erection/termination/wiring in connection with any signalling work
8 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender document, Scope of work & GCC 2022 are attached with the tender.
Signalling work in connection with Provision of crossover between UP & DN TH line in Vikhroli & Shifting of crossover 108 to relax existing PSR 60 Kmph at Byculla in Mumbai division.
CR-BB-SNT-SOUTH-2026-31
CR-BB-SNT-SOUTH-2026-31
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹3.2 L
1 May 2026
1 Apr 2026
17 Apr 2026
144 items across 6 schedules · ₹75,10,033.19 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-RDSO) | Kilometre | 6.00 | 8,647.71 | 51,886.26 |
| 2 | Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amd.3) or latest. (Inspection Agency-RDSO) | Kilometre | 6.00 | 13,093.54 | 78,561.24 |
| 3 | Supply of wire 16/0.2 (Blue, Red, Grey, yellow, B r o w n , Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S- 76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection Agency-RDSO) | Kilometre | 6.00 | 6,445.17 | 38,671.02 |
| 4 | Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3). (Inspection Agency-RDSO) | Kilometre | 1.20 | 3,26,216.47 | 3,91,459.76 |
| 5 | Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) | Numbers | 150.00 | 206.14 | 30,921 |
| 6 | Supply of Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK 30/0052) or GIC make or functional equivalent. (Inspection Agency-Consignee) | Numbers | 6.00 | 7,793.62 | 46,761.72 |
| 7 | Supply of Key Lock Relay with different ward combinations (Three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24V DC or functional equivalent without base plates. RDSO/SPN/219/ 2016 Version 1.0 d 1(Inspection Agency-Consignee) | Numbers | 1.00 | 9,145.93 | 9,145.93 |
| 8 | Supply of RCC pipes half round of size 300mm dia outer and 250 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) | Numbers | 150.00 | 422.25 | 63,337.5 |
| 9 | Supply of Domino units with cover plate as per approved panel diagram, each of size 54 x 34mm completely wired up similar to Siemens make. Each domino units should have all the 15 contact terminals wired up.(Inspection Agency- Consignee) | Numbers | 20.00 | 1,619.54 | 32,390.8 |
| 10 | Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement.(Inspection Agency- Consignee) | Kg | 3.00 | 1,252.58 | 3,757.74 |
| 11 | Lacing thread rolls, black, wax coated (100 mtrs).(Inspection Agency-Consignee) | Numbers | 20.00 | 66.15 | 1,323 |
| 12 | Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee) | Numbers | 1.00 | 6,948.5 | 6,948.5 |
| 13 | Supply of Shunt Signal Post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.). (Inspection Agency-Consignee) | Numbers | 1.00 | 2,711.85 | 2,711.85 |
| 14 | Supply of Cast Iron Main signal surface base 140mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA- 23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice(Inspection Agency-Consignee) | Numbers | 1.00 | 9,034.12 | 9,034.12 |
| 15 | Supply of Cast iron Shunt signal surface base 80 mm as per spec No.IRS S 10 and Drg No.2011/M with latest amendments, as per RDSO Drg No. SA-23156/Drg.No.RST/11413 as per extent C.Rly practice(Inspection Agency- Consignee) | Numbers | 1.00 | 2,071.84 | 2,071.84 |
| 16 | Supply of Signal No.plates. as per Drg No RST- 11393 / SK-842 or latest(Inspection Agency- Consignee) | Numbers | 10.00 | 521.69 | 5,216.9 |
| 17 | OFF set bracket 5-1/2 " to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg.No.SA- 23080 for Signals & Routes(Inspection Agency- Consignee) | Numbers | 1.00 | 999.74 | 999.74 |
| 18 | Supply of A/AG/C/P/G/IB Board as per Drg. RST- 11444/1(A), RDSO Drg No SA 23460(AG), SA- 23461©, RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment. (Inspection Agency-Consignee) | Numbers | 2.00 | 561.74 | 1,123.48 |
| 19 | Supply of "4 Aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post Saves pigment finish on the back side of the end inside. White Pigment finish inside the 4 aspect unit to avoid any extra paint cost.(Inspection Agency-Consignee) | Numbers | 1.00 | 41,024.56 | 41,024.56 |
| 20 | Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification No.RDSO/SPN/ 194/2006/Rev.2.0 or latest with Off set bracket 3-1/2" to be fitted on 140 mm post drawing No. SA 23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED Signal lamps. (Inspection Agency-Consignee) | Numbers | 1.00 | 13,950.27 | 13,950.27 |
| 21 | Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED sigal Lamps. (Inspection Agency-Consignee) | Numbers | 2.00 | 8,669.75 | 17,339.5 |
| 22 | Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements .(Inspection Agency-Consignee) | Set | 10.00 | 531.87 | 5,318.7 |
| 23 | Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692(Inspection Agency- Consignee) | Set | 20.00 | 338.3 | 6,766 |
| 24 | Supply Gauge Tie plate nylon insulation as per RDSO drg No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendement 01 or latest amendements. (Inspection Agency-Consignee) | Set | 10.00 | 244.11 | 2,441.1 |
| 25 | Supply of GI bend pipe, 'B' class, 50mm dia for cable entry in point machines, alongwith required fixing arrangements as per standard practice on Central Railway. As per Drg No. RST.11835.(Inspection Agency-Consignee) | Numbers | 2.00 | 252.78 | 505.56 |
| 26 | Supply of Point Machine Raised Bracket FRP make with cover as per Drg No.SK-846. (Inspection Agency-Consignee) | Numbers | 4.00 | 878.77 | 3,515.08 |
| Schedule total | ₹8,67,183.17 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC 2022
ATTACHMENT
CORRECTIONSLIP1to10GCC2022.pdf GCC CORRECTION SLIP 1 TO 10
ATTACHMENT
FINALNEWTENDERDOC2026-31.pdf TENDER DOC
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY.pdf
ATTACHMENT
CORRECTIONSLIP1to10GCC2022.pdf
ATTACHMENT
FINALNEWTENDERDOC2026-31.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .