| 1 | L1₹16.1 LAccepted-AOC MALHARPETH TAL PATAN DIST SATARA MAHARASHTRA | MALHARPETH | SATARA | MAHARASHTRA | ₹16.1 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Documents are not as per tender notice |
Updated dates
Tender Value
₹16.1 L
EMD Value
₹16,102
Closing Date
13 Dec 2025, 5:00 pmClosed
Executive Engineer RWSD
Rural Water Supply Division Z P Satara
Providing PWSS for Riswad, Tal. Patan, Dist. Satara
2025_SATAR_1252271_1
ZPS/RWS/KhanijVikas/2025 - 1st call
Open Tender
Civil Works - Water Works
365 days
Riswad, Tal. Patan
Please refer Tender Document
8 documents required · 8 mandatory
₹1,000
₹16,102
10 Feb 2026
26 Nov 2025
15 Dec 2025
26 Nov 2025
13 Dec 2025
26 Nov 2025
SUB WORK NO 1- Supply Well
Item no 1 :-Excavation in general in soft materilas comprising of soft soil soft murum ,sand ,hard murum with boulders in wet or dry condition for head works i,e intake well connecting pipe jack well pump house supply well etc. for lift 0.00 to 1.50m and lead 150m including barricading ,gaurding disposing of surflus excavated stuffs within a radious of 0.50 km as directed by engineer in - charge complete. excluding refilling
M.J.P.DSR 23-24 39/10 b
Item no 2 :-Excavation for foundation / pipe trenches in hard rock by controlled blasting including trimming and levelling the bed by chiselling where necessary & removing the excavated material & stacking it in me-asurable heaps,within a distance of 50 m. from the area & lift as below, normal dewatering, excluding back filling, etc.complete
M.J.P.DSR 23-24 39/11b
Item No 3 :-Dewatering the excavated tranches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer - in -charge ( including cost of machinery, labour, fuel ), etc. complete.
M.J.P.DSR 23-24 40/14 89.00+10%
Item No 4 :- Providing &fixing 80 m.m.dia A.c. / p. v. c. pipe weap holes at 1.5m c/c staggered including cost of all materials and labour involved with all leads and lifts etc. complete for well staining wallof necessary diameter.
M.J.P.DSR 23-24, 291/5 231+10%
Item No 5:- Providing &laying in situ P.C.C. 1:2:4 (M-15) of trap metals as per detailed drawing including formwork compacting curing etc. complete.
MJP SSR 23/24, 47/1b
Item No 6:-Providing &fixing in position Steel reinforcement of verious diameters for R.C.C.pile caps, footings, foundations, slabs, beams, columns, staining walls, etc. as per detailed drawings, designs, & schedules. including cutting, bending, hooking, & binding with wires.etc. completed.
M.J.P.DSR 23-24 50/8b 80681.00+10%
Item No 7:- Providing &laying in situ Reinforced cement concrete 1:1/2:3 (M- 30) of trap metals as per detailed drawing & design for Beam including formwork compacting curing etc.complete .(Excluding steel reinforcement)
MJP SSR 23/24
Item No 8:- Providing &laying in situ Reinforced cement concrete 1:1/2:3 (M- 30) of trap metals as per detailed drawing & design including formwork compacting curing etc.complete .(Excluding steel reinforcement) Staining Wall
5.00 to 0.00 Mt & Parapet
Item No 9 - Refilling the trenches with available excavated stuff with soft material fist ovar pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
MJP SSR 23/24
Item no 10 :- Providing and fixing M.S.steel RSJ channel girder for supporting to pumping machinery etc. complete.
M.J.P.DSR 23-24 46/5, 89542+10%
Item No11:-Providing &Fixing in position C. I. dapuri steps of 22mm dia. M. S. bars steps with proper anchorage with applying three coats of anti-corrosive oil paint etc. comleted.
M.J.P.DSR 23-24 292/11 464+10%
Item No12 :- Taking trial bore (Core Bore Sampling) byCallyx machine with TCT/NX bits to gatherundisturbed strata samples for investigationin all types of strata, soft soil, murum, hardmurum with boulders, soft rock, hard rock andquartzite, etc. The item includes all hire and running cost of Callyx machine, conveying allmaterials to site of work excluding conveyance of callyx machine and back sampling all overburden strata in glass jar and core samples serially numbered at site in a wooden corebox, samples to be taken at 1.0 M interval and conveying to the place as directed byEngineer-in-charge. The diameter of bore in overburden shall be 100 mm and of NX size(50 mm) in other strata. The item shall also include M.S. casing pipe of 2.5 mm thick platein overburden only and shall be 1.0 M above GL with cap over it.
SUB WORK NO 2- Rising Main
Item No.1 -Providing & supplying in standard lengths polyethelene Pipes, conforming to IS 4984/14151/12786/ 13488 with necessary jointing material like mechanical connector i.e.thread/ insert joint/ quick release coupler joint, including all local & central taxes, transportation and freight charges inspection charges, loading/unloading charges, conveyance to the departmental stores/ site & stacking the same in closed shade duely protecting from sunrays & rains, etc.
75 mm dia HDPE Pipe PE- 100- 10 kg/cm2
MJP DSR 23/24, 123/1A
Item No.2-Providng and supplying Idouble flange Sluice valves confirming for IS 2906/14846 including worn gear arrangement as per test pressure stainless steel spindle, caps including all taxes transportation etc.complete.
65 mm dia sluice valve PN-1
65 mm dia N.R. valve PN-1
MJP DSR 23/24, 145/2
Item No.3 - Excavation for foundation / pipe trenches inhard murum including removing theexcavated material upto a distance of 50 Mand lifts as below, stacking and spreading as directed by Engineer-in-charge, normaldewatering, preparing the bed forfoundation and excluding backfilling, etc.complete.
Item No.3 -Excavation for foundation/ pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 mtrs. and lifts as below, stacking and spreading as directed, normal dewatering,preparing the bed for foundation and excluding backfilling etc.complete.
MJP DSR 23/24, 37/3
Item No.4 - Excavation for foundation / pipe trenches insoft rock and old cement and limemasonry foundation asphalt roadincluding removing the excavated materialupto a distance of 50 M beyond the areaand lifts as below, stacking as directed byEngineer-in-charge, normal dewatering,preparing the bed for foundation andexcluding backfilling, etc. complete. (Bd-A4/259)
MJP DSR 23/24, 38/7
Item No.5 - Lowering laying & jointing H.D.P.E. Pipe by heating to the ends of pipe with the help of tefflon coated electrimirror/heater to the required temparature & then pressing the end together against each other to form a monolithic & leak proof joint by thermosetting process. the pressing may be required to be done with Jack/Hydraulicjack/Vutt fusion machine etc. complete. with all maerial,labours as directed by Engineer in charge including given satisfacory hydraulic test.
65 mm dia HDPE Pipe PE- 100- 8 kg/cm2
MJP DSR 23/24, 125/2
Item No.6 - Hydraulic testing of H.D.P.E. Pipe to specified pressure including cost of all materials and labourand water for testing for specified length incluiding cutting placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to providespecified test pressure gauges and other necessary equipments, labour, operation charges, etc required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to origenal position.
75 mm dia HDPE Pipe PE- 100- 10 kg/cm2
MJP DSR 23/24, 126/3
Item No.7- Lowering, laying and jointing in position following C.I.D./F. sluice valve including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.
65 mm dia sluice valve PN-1
65 mm dia N.R. valve PN-1
MJP DSR 23/24, 148/4
Item No.8 - Giving satisfactory hydraulic testing of following C.I.D / F Reflex Valves, Butterfly valves and Sluice Valves.
65 mm dia sluice valve PN-1
65 mm dia N.R. valve PN-1
MJP DSR 23/24, 148/4b
Item No.9-Providing, supplying and fixing Air valves as per IS-10845 amd MJP's standard specifications of approved make and quality of following diameters including all taxes(central and local), railway freight, inspection charges unloading from railway wagons, loading into truck, transportation upto departmental stores/site, unloading, stacking etc.complete.
12/15 mm dia Air valve 760+149+14.90
MJP DSR 23/24
Item No.10 - Providing and laying in situ cement concrete mortar 1:2:4 of trap metal for foundation and bedding including bailing out water manually formwork compacting & curing etc. complete.
MJP DSR 23/24, 47/1b
Item No.11 - Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
MJP DSR 23/24, 40/15
Item No.12 - Filling in plinth and floor Murum bedding in trenche with approved murum from excavated materials from foundation in 15 to 20 cm layers including watering and compaction etc. complete.
MJP DSR 23/24, 41/16
Item No.13 :- Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004.
65 mm dia Medium 524+118+11.80
MJP SSR 23/24, 93/1
Item No.16 :- Providing and fixing in position Name Board of the work showing details of the scheme etc. complete
SUB WORK NO 3- PUMPING MACHINRY
Item No.1 - Providing installing, commissioning and testing of submerssible pump set LPM discharging water against a total head of m from all causes when running at 2900 RPM (Approx) directly coupled to submotor squrrel gage induction type of adquate capacity as per detail specifications.
3.00 HP, 3 Phase, 2275 lph, 75 m Head.
Item No.2 - Providing, erecting , commissioning & testing of floor mounting type L.T. pannel board (skeletion type) as per detail specifications.
Item No. 3 -Providing laying, jointing and testing of PVC water proof sub cable copper conductor of type ( 1x 3 x 4) sqm size as per detail specifications.
Item No.4 -Providing laying & testing of PVC allu. conductor armoured cable (1x3x4) core size & as per details specifications.
Item No.5 - Providing and testing varnished plank 20 mm thick fixed towall or on provided pannel board for fitting MSEB connection with necessary materials supports etc. complete.
Item No.6-Providing, installing, testing, earthing arrangement to installation of motor, L.T. pannel board starter etc. complete as per details specifications.
Item No.7 - Providing and lowering, laying and jointing in position Vertical Drop pipe etc. complete. as directed by Engineer & as per specification complete.
SUB WORK NO 4- RCC GSR
A) Material Section
Item No.1:- Providing ISI mark G.I. pipes of following class and diameters incl
uding all local and central taxes, octroi, inspection charges, transportation to stores, etc.complete.
65 mm dia Medium
MJP SSR 23/24,
Item No.2 - Providng and supplying Idouble flange Sluice valves confirming for IS 2906/14846 including worn gear arrangement as per test pressure stainless steel spindle, caps including all taxes transportation etc.complete.
80 mm Sluice Valve PN 1
65 mm dia Medium
65 mm dia sluice valve PN 1
B) Labour Section
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
DetailTender.pdf
Tender Documents • 1.28 MB
Pre_Qualification.pdf
Other Document • 0.22 MB
BOQ_2158956.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid