Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹1.7 L+₹1,800 (1.10%)Accepted-Finance | L2 | Accepted-Finance Accepted | |
| 3 | L3₹1.7 L+₹6,750 (4.11%)Accepted-Finance H NO 338 LIG JARAULI PHASE 2 VAISHNAVI VIHAR KANPUR NAGAR UTTAR PRADESH 208027 | KANPUR NAGAR | UTTAR PRADESH | 208027 | L3 | Accepted-Finance Accepted |
Tender Value
₹1.7 L
EMD Value
₹5,500
Closing Date
28 Apr 2025, 11:00 amClosed
Executive Engineer ETD-II
ETD-II Vidyut colony govind nagar kanpur
OVERHAULING/MAINTENANCE OF 33KV VCB INSTALLED AT 220KV S/S KANPUR SOUTH UNDER ETD-II KANPUR.
2025_UPTCL_1027491_1
E-Tender no.2/ETD-II(K)/2025-26
Open Tender
Electrical Works
Fixed-rate
220KV S/S KANPUR SOUTH UNDER ETD-II KANPUR.
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Executive Engineer ETD-II Kanpur
₹5,500
1 May 2025
11 Apr 2025
28 Apr 2025
11 Apr 2025
28 Apr 2025
11 Apr 2025
Amount
Following works are required for proper health checking & avoid unwanted breakdown of 33KV VCB at 220KV substation Kanpur South under ETD-II, Kanpur. Details of 33KV VCB/bays are as below: Rooma, Air-Force, Sanjay Nagar, Ganga Pollution, Wazidpur, Sarsaul, Narwal, Ahirwan, Purwameer (Total 09Nos) i. Checking and adjustment of snatch gap travel of drive insulators rod and tie rod of each pole. ii. Replacement of all damaged and defective parts closing latch assembly, strip latch, close coil etc. and its proper adjustment cleaning and greasing. iii. Oiling and greasing of crank gear by opening of lock clip etc. iv. Dismantling of all pole linkage, pins and rod assembly, cleaning, greasing and its proper adjustment v. Check satisfactory trip & close operation of the breaker both by local/remote vi. Check close/trip timing of digital timer kit. vii. Repairing of mechanism for rectification of mechanical problem. After overhauling of VCB following tests to be carried out… (a) Opening and closing timing of each pole of VCB. (b) Carrying of contact resistance measurement of each pole of VCB. (c) Checking of megger value of each pole of VCB.
Indra Enterprises (BID ID -5150157)
M/s Prakash & Brothers (BID ID -5150188)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .