| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.1 CrAccepted-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹1.1 Cr | L-1 | Accepted-AOC L1 |
| 2 | L-2₹1.2 Cr+₹8.1 L (7.25%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | ₹1.2 Cr+₹8.1 L (7.25%) | L-2 | Rejected-Finance Lowest-2 |
| 3 | L-3₹1.4 Cr+₹24.3 L (21.9%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | ₹1.4 Cr+₹24.3 L (21.9%) | L-3 | Rejected-Finance Lowest-3 |
| 4 | Rejected-Technical 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | - | - | Rejected-Technical Submitted documents are not as per NIT criteria. |
| 5 | Rejected-Technical OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | - | - | Rejected-Technical Submitted documents are not as per NIT criteria. |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
23 Jun 2022, 5:00 pmClosed
SM (E-E)
O/o Airport Director, SM (E-E),AAI, R. B. Airport.
Construction of ATC Tower cum Technical Block at Raja Bhoj Airport Bhopal. SH Shifting of CCRs, GLF UPS and rerouting of GLF feeder cables.
2022_AAI_117241_1
AAI/BPL/ENGG(E)/NIT-06/2022-23
Open Tender
Electrical Works
Works
180 days
AAI, R. B. Airport
Please refer Tender documents.
19 documents required · 19 mandatory
₹1,120
₹3.3 L
25 Jul 2024
31 May 2022
24 Jun 2022
31 May 2022
23 Jun 2022
3 Jun 2022
31 May 2022 - 2 Jun 2022
Amount
Dismentling/Disconnecting, Shifting, Reinstallation, Testing and Commissioning of following capacity, Indoor type air cooled constant current regulator (CCR) complete etc. as required from Old Power House to New CCR Room at New ATC Tower near NITB of R. B. Airport Bhopal. 30 kW
Dismentling/Disconnecting, Shifting, Reinstallation, Testing and Commissioning of following capacity, Indoor type air cooled constant current regulator (CCR) complete etc. as required from Old Power House to New CCR Room at New ATC Tower near NITB of R. B. Airport Bhopal. 20 kW
Dismentling/Disconnecting, Shifting, Reinstallation, Testing and Commissioning of following capacity, Indoor type air cooled constant current regulator (CCR) complete etc. as required from Old Power House to New CCR Room at New ATC Tower near NITB of R. B. Airport Bhopal. 10 kW
Dismentling/Disconnecting, Shifting, Reinstallation, Testing and Commissioning of following capacity, Indoor type air cooled constant current regulator (CCR) complete etc. as required from Old Power House to New CCR Room at New ATC Tower near NITB of R. B. Airport Bhopal. 7.5 kW
Dismentling/Disconnecting, Shifting, Reinstallation, Testing and Commissioning of following capacity, Indoor type air cooled constant current regulator (CCR) complete etc. as required from Old Power House to New CCR Room at New ATC Tower near NITB of R. B. Airport Bhopal. 4 kW
Dismentling/Disconnecting, Shifting, Reinstallation, Testing and Commissioning of 2x160 kVA UPS (Make: Vertiv) complete etc. as required from Old Power House to New CCR Room at New ATC Tower near NITB of R. B. Airport Bhopal.
Dismentling/Disconnecting, Shifting, Reinstallation, Testing and Commissioning of Electrical Panel complete etc. as required from Old Power House to New CCR Room at New ATC Tower near NITB of R. B. Airport Bhopal.
Supply of 6.0 sqmm, 5 KV grade copper conductor XLPE insulated, polyethylene sheathed, single core, copper tape unscreened runway cable as required.
Supply of 16.0 sqmm, 5 KV grade copper conductor XLPE insulated, polyethylene sheathed, single core, copper tape unscreened runway cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (80 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (80 cm below ground level) in the same trench including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Providing and Fixing of 50 mm dia (medium class) G. I. pipes i/c digging work of 2 feet depth & 1 feet width for the road crossing & filling the surface with 1:3:6 PCC complete as required.
Laying of one number PVC insulated and PVC sheathed runway cable of 5 KV grade upto 16 sqmm size in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number PVC insulated and PVC sheathed runway cable of 5 KV grade upto 16 sqmm size in the existing masonry open duct as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply of 6.0 sqmm, 5 KV grade plug and receptacle having suitable field attachment with 5 KV grade XLPE insulated, PE sheathed, single core copper conductor unscreened cable as required.
Supply of 16.0 sqmm, 5 KV grade plug and receptacle having suitable field attachment with 5 KV grade XLPE insulated, PE sheathed, single core copper conductor unscreened cable as required.
Supply of heat shrinkable jointing kit of 6.0 sq. mm size, single core copper conductor, 5 KV grade for Airfield lighting cable complete etc. as required.
Supply of heat shrinkable jointing kit of 16.0 sq. mm size, single core copper conductor, 5 KV grade for Airfield lighting cable complete etc. as required.
Earthing with G. I. pipe 4.5 m long x 40 mm dia. (Drilling of 300 mm dia, 4.5 Mtr deep by using Borewell machine) including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. including charcoal or coke and salt complete as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supply of Following Size. XLPE insulated, PVC sheathed Al. conductor armoured power cable of 1.1 KV grade conforming to IS:7098 Part-I with upto date amendment etc. complete as required. 3.5 Core x 95 Sqmm.
Supply of Following Size. XLPE insulated, PVC sheathed Al. conductor armoured power cable of 1.1 KV grade conforming to IS:7098 Part-I with upto date amendment etc. complete as required. 3.5 Core x 50 Sqmm.
Supply of Following Size. XLPE insulated, PVC sheathed Al. conductor armoured power cable of 1.1 KV grade conforming to IS:7098 Part-I with upto date amendment etc. complete as required. 3.5 Core x 35 Sqmm.
Supply of Following Size. XLPE insulated, PVC sheathed Al. conductor armoured power cable of 1.1 KV grade conforming to IS:7098 Part-I with upto date amendment etc. complete as required. 3.5 Core x 25 Sqmm.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) in the same trench including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/PVC pipe as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminum lugs for following size of XLPE insulated and PVC sheathed aluminum conductor cable of 1.1 KV grade as required 3.5 core x 50 Sq.mm (35mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of XLPE insulated and PVC sheathed aluminum conductor cable of 1.1 KV grade as required 3.5 core x 35 Sq.mm (32mm)
Supplying and making end termination with brass compression gland and aluminum lugs for following size of XLPE insulated and PVC sheathed aluminum conductor cable of 1.1 KV grade as required 3.5 core x 25 Sq.mm (28mm)
Vardhman Airport Solutions Pvt Ltd
Techno Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .