Loading…
Loading…
Tender Value
₹2.4 L
EMD Value
₹4,900
Closing Date
13 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
PND WORKS
12 conditions · 1 needing a document upload
No Technical & Financial credentials are required for tenders having advertised value upto Rs.50 Lakhs.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
6 conditions · 2 needing a document upload
GST Registration certificate along with its all supportive documents as per GCC 2022 must be submitted by the bidder. Note: Non-Submission of GST Registration Certificate by the Bidder shall result in summarily rejection of his/their bid.
The firm may submit following documents:- (1) PAN Card, (2) Cancelled cheque or Bank Mandate form, (3) EPF Registration/ Declaration, (4) ESI Registration/ Declaration, (5) Recent Income Tax Return clearance or Balance sheet etc.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
GCC 2022 and its all amendments from Railway Board will be applicable in this work.
The firm has to submit a list of staffs and supervisors to be engaged by him indicating their name, father's name, sex, age, address of the staff and recent passport size photograph for formal approval of gate passes before commencement of the subject work. It is also advised to apply for issue of gate entry pass for labours and materials prior to commencement of work along with self attested photocopy of aadhar card, PAN card and the police verification of engaged labours through the online portal digitalpolice.gov.in must be submitted by firm before commencement of the work.
Provision of Centre of Excellence at Shop No. 11/GE Section at Kanchrapara Workshop for electrical (G) works under jurisdiction of Dy.CEE/G/KPA.
KPA-EG-OT-07-26-27~ER
KPA-EG-OT-07-26-27
Open
Works - General
6 Months
North 24 Parganas, West Bengal
₹0
₹4,900
21 Sept 2026
21 Sept 2026
29 Sept 2026
61 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,44,682.61 | ||
| — | — | — | Above/ 42778.28 Below/P | ||
| Supply, installation, connection, testing and commissioning of 4 pole MCCB of 160A, 415V, 50Hz, 35kA (minimum) breaking capacity with adjustable thermal magnetic trip unit, over load, earth fault and short circuit protection in a suitable powder coated steel sheet enclosure with all accessories including connection with gland, socketing, cable entry box etc. as required (make as per Annexure-I) | for details. | Breakup | — | — | |
| — | — | — | Above/ 1339.36 Below/P | ||
| Supply, erection, testing and commissioning of LT XLPE cable gland with aluminium sockets/lugs (4 Nos.) suitable for LT 4 core 50-95 sq.mm XLPE insulated aluminum conductor armoured cable. | — | 4.00 | — | — | |
| — | — | — | Above/ 1507.02 Below/P | ||
| Supply of indoor type LED Tube light, 4 ft. length, 16-22W, Retrofit type, SMD LED chip, life span of LED >/= 50,000 burning hours, CRI >/= 70, system efficacy >/= 100 Lm/W, color temperature: 6500 ± 500K (cool white), PF >/= 0.9, IP 20 or better suitable for 220-230V AC, 50Hz. (make as per Annexure-I) | — | 6.00 | — | — | |
| — | — | — | Above/ 645.90 Below/P | ||
| Supply of batten suitable for 1 No. LED tube light of 4 feet long, both side holder, without ballast and starter with internal copper wiring. | — | 6.00 | — | — | |
| — | — | — | Above/ 946.92 Below/P | ||
| Fixing, connection, testing and commissioning of LED tube light fittings with batten for indoor use with suitable size GI clamps and GI nut-bolts and PVC insulated twin copper flexible cord as connected lead including old fittings to be removed, if any required.(N.B: All materials required during execution of the work and connections are to be supplied by the firm). | — | 6.00 | — | — | |
| — | — | — | Above/ 26730.00 Below/P | ||
| Supply of LED surface mounted ceiling light having 2ft x 2ft flat panel, 34-38W, CRI 80, system efficacy >/= 100 Lm/W, color temperature: 6000 ± 10%K (cool day light), PF >/= 0.9, life span of LED >/= 50,000 burning hours, with inbuilt SMPS based constant current driver having protection against short circuit, reverse polarity, high voltage, overload etc. with aluminium / polycarbonate housing & polycarbonate diffuser, IP20 suitable for single phase, 220-230V, 50 Hz AC supply. (Make as per Annexure-I) | — | 10.00 | — | — | |
| — | — | — | Above/ 2086.40 Below/P | ||
| Fixing, connection, testing & commissioning of LED surface mounted 2ft x 2ft flat panel ceiling light with necessary arrangement and accessories.N.B. All materials required during execution of the work and connection are to be supplied by the firm. | — | 10.00 | — | — | |
| — | — | — | Above/ 431.31 Below/P | ||
| Installation, connection, testing and commissioning of the ceiling fan by suitable size GI clamps made of GI flat / 'S' hook & GI nut-bolts including PVC insulated twin copper flexible cord as connected lead and necessary masonry works.(N.B.: Only ceiling fans will be supplied by Railways. All other materials required during execution of the work and connection are to be supplied by the firm) | — | 3.00 | — | — | |
| — | — | — | Above/ 6087.76 Below/P | ||
| Supply of wall bracket fan of 400mm sweep suitable for single phase 220-230V, 50Hz including all accessories (make as per Annexure-I). | — | 2.00 | — | — | |
| — | — | — | Above/ 695.56 Below/P | ||
| Installation, connection, testing and commissioning of wall bracket fan by suitable size GI clamps, GI nut-bolts etc. including PVC insulated twin copper flexible cord as connected lead and necessary masonry works. (N.B.: All materials required during execution of the work and connection are to be supplied by the firm) | — | 2.00 | — | — | |
| — | — | — | Above/ 7033.56 Below/P | ||
| Supply, installation, testing & commissioning of 6 [i.e. 2+4] way double door powder coated SPN DB consisting of (i) SPN/DP MCB of 40-63A, 10kA (minimum) breaking capacity - 1 No., (ii) SP MCB of 6-32A, 10kA (minimum) breaking capacity - 4 Nos. with neutral link, earth bar, DIN rail and all other accessories (Make: as per Annexure-I).N.B. Ratings of MCB will be decided by Rly. authority. | for details. | Breakup | — | — | |
| — | — | — | Above/ 9754.50 Below/P | ||
| Wiring of main / sub-main line in concealed way with 02 Nos. 6 sq.mm (for phase and neutral) and 01 No. 2.5 sq.mm (for ECC) copper wire in suitable size, heavy gauge, inflammable PVC pipe including all other accessories with dismantling of existing wiring, if any, and making good of wall / ceiling surface as its original condition. Copper wire shall be PVC insulated, multi-strand, single core, FR/ ZHFR/ FRLSH, 1100V grade conforming to IS:694 of latest amendment. The wiring shall be done in conformation with IS:732 of latest amendment and IE rules upto date. Main/sub-main wiring shall be measured on linear basis along the run of the wiring. The measurement shall include all lengths from end to end of conduit or channel as the case may be, exclusive of interconnections inside the switchboard (make as per Annexure-I). | — | 30.00 | — | — | |
| — | — | — | Above/ 40005.00 Below/P | ||
| Wiring of main / sub-main line in concealed way with 02 Nos. 4 sq.mm (for phase and neutral) and 01 No. 1.5 sq.mm (for ECC) copper wire in suitable size, heavy gauge, inflammable PVC pipe including all other accessories with dismantling of existing wiring, if any, including make good of wall / ceiling surface as its original condition. Copper wire shall be PVC insulated, multi-strand, single core, FR/ ZHFR/ FRLSH, 1100V grade conforming to IS:694 of latest amendment. The wiring shall be done in conformation with IS:732 of latest amendment and IE rules upto date. Main/sub- main wiring shall be measured on linear basis along the run of the wiring. The measurement shall include all lengths from end to end of conduit or channel as the case may be, exclusive of interconnections inside the switchboard (make as per Annexure-I). | — | 150.00 | — | — | |
| — | — | — | Above/ 16123.80 Below/P | ||
| Wiring of light, fan, call bell etc. in concealed way with 02 Nos. 2.5 sq.mm (for phase and neutral) and 01 No. 1.0 sq.mm (for ECC) copper wire in suitable size, heavy gauge, inflammable PVC pipe with provision of suitable size modular PVC boards, GI concealed boxes, modular switches (piano type), fuses, indication lamps, ceiling rose, angular holder etc. and all other required accessories with fixing & commissioning electronic fan regulator in case of fan point (excluding supply of fan & regulator) with dismantling of existing wiring, if any, including make good of wall / ceiling surface as its original condition. Copper wire shall be PVC insulated, multi-strand, single-core, FR/ZHFR/FRLSH, 1100V grade conforming to IS:694 of latest amendment. The wiring shall be done in conformation with IS:732 of latest amendment and IE rule upto date. The circuit shall be planned in such a way that each board shall not exceed total 10 points of light, fans & 6A socket outlets & total connected load of such board shall be restricted to 800W (make as per Annexure-I). | — | 21.00 | — | — | |
| — | — | — | Above/ 881.80 Below/P | ||
| Supply, installation, testing & commissioning of 6A plug-socket point with 6A modular type switch, 6A, 3 pin (minimum) modular type socket, PVC board / cover, suitable size GI/PVC mounting box as per advice of the competent authority, if required & all other required accessories including internal wiring (make as per Annexure-I). | — | 4.00 | — | — | |
| — | — | — | Above/ 477.30 Below/P | ||
| Supply, installation, testing & commissioning of 16A plug-socket point with 16A modular type switch, 16A, 3 pin (minimum) modular type socket, modular indication lamp, modular fuse with PVC board / cover in suitable size GI/PVC mounting box as per advice of the competent authority in a separate board & all other required accessories including internal wiring (make as per Annexure-I). | — | 2.00 | — | — | |
| — | — | — | Above/ 2869.94 Below/P | ||
| Supply, installation, testing & commissioning of multi-plug point with modular type switches, sockets, PVC board/cover, suitable size GI/PVC box as per advice of the competent authority consisting of the followings & all other required accessories with internal wiring: (i) 6A switch - 03 Nos., (ii) 6A, 3 pin (minimum) plug-socket - 03 Nos., (iii) 16A switch - 01 No., (iv) 16A, 3 pin (minimum) plug-socket - 01 No., (v) 16A MCB - 01 No., and (vi) LED indicator - 01 No. (make as per Annexure-I). | — | 2.00 | — | — | |
| — | — | — | Above/ 3050.40 Below/P | ||
| Supply of powder coated metallic stand / bracket with accessories suitable for wall mounting of outdoor unit of 1.5 Ton or above high wall split air-conditioner including suitable size nuts, bolts, fasteners, washer and other required accessories. | — | 4.00 | — | — | |
| — | — | — | Above/ 9432.00 Below/P | ||
| Supply of additional copper pipe of 1/2 inch nominal dia. suitable for air conditioning machine. | — | 20.00 | — | — | |
| — | — | — | Above/ 5897.80 Below/P | ||
| Supply of additional copper pipe of 1/4 inch nominal dia. suitable for air conditioning machine. | — | 20.00 | — | — | |
| — | — | — | Above/ 1416.00 Below/P | ||
| Supply, fixing, testing and commissioning of additional thermal insulation foam pipe suitable for covering of 1/2 inch dia. copper refrigerant pipe. | — | 20.00 | — | — | |
| — | — | — | Above/ 1180.00 Below/P | ||
| Supply, fixing, testing and commissioning of additional thermal insulation foam pipe suitable for covering of 1/4 inch dia. copper refrigerant pipe. | — | 20.00 | — | — | |
| — | — | — | Above/ 12517.20 Below/P | ||
| Supply, fixing, testing & commissioning of water proof, heavy duty, thermal insulating, self-adhesive, protective PVC wrapping tape, white/cream colored, 48mm width (min.), 20 mtr. long (min.) in a roll, for covering & protection of copper refrigerant tube/pipes of air-conditioner. | for details. | Breakup | — | — | |
| — | — | — | Above/ 7877.08 Below/P | ||
| Supply, fixing, connection, testing and commissioning of AC starter module comprising of 32A SPN/DP MCB and starter (suitable upto 2 Ton single phase AC machine) in a suitable size enclosure with all accessories and 16-25A modular type shuttered plug socket (separately or combined with starter module, as per advice of the competent authority) with PVC board / cover & suitable size GI/PVC mounting box & all other required accessories. (Make: as per Annexure-I). | for details. | Breakup | — | — | |
| — | — | — | Above/ 424.80 Below/P | ||
| Supply, fixing, connection, testing and commissioning of 16A power plug-top with all required accessories (Make: as per Annexure-I). | — | 4.00 | — | — | |
| — | — | — | Above/ 19648.94 Below/P | ||
| Supply of GI tubular pole of 7mtrs. hight, 85Kg. (approx.) weight along with single / double arm bracket & junction box at the top/inbuilt as per site condition and installation, testing & commissioning of the pole including making of cement concrete foundation, muffing etc. and complete wiring of light point with 2 Nos. 2.5 sqmm PVC insulated copper wire. The pole shall be as per IS:2713 (Pt. 1-2) of latest amendment & hot dip galvanised.N.B.: Single/Double arm will to be decided by Railway authorities as per site requirements. Pole shall be marked with the manufacturer's identification, year of manufacture etc. All precaution must be taken for casting of foundation. The price shall cover all materials required for the above foundation work / masonry works viz. cement, sand, stone-chips etc. The copper wire shall be multi-strand single-core FR/ZHFR/FRLSH 1100V grade conforming to IS:694 of latest amendmend. The foundation will be done as per approved drawing & design. (Make as per Annexure-I) | for details. | Breakup | — | — | |
| — | — | — | Above/ 2647.04 Below/P | ||
| Supply of earth pipe made from 50mm (or above) nominal bore (dia.) heavy duty GI pipe, 3 mtr. (minimum) long and digging, insertion, testing and commissioning of earth pipe including construction of earth pit and necessary earth connection from pit to the electrical assets with 6 SWG (or thicker) GI wire. Alternate layer of salt and charcoal are to be spread inside the pit. Earth pit shall be completed with necessary civil work like brick chamber, PCC work & finally covered with medium duty cast iron hinged cover of suitable size (GI pipe make as per Annexure-I). N.B: The earthing should be done as per CEE/KKK's specification. All earth value should be marked on MS plate with date by painting work and MS plate should be fixed with earth pit or nearby wall properly by suitable size nuts and bolts. The MS flat, plate should be painted by one coat of red oxide and two coats of black paint before execution. The marking should be done by white paint. | for details. | Breakup | — | — | |
| — | — | — | Above/ 10096.66 Below/P | ||
| Supply of 85-90W LED luminaries in pressure die casted aluminium alloy housing having with higher thermal conductivity and corrosion resistant powder coated body with transparent toughened glass cover (thickness >/= 4mm), SMD LED chip as per LM80, photo- biological safety (exempt group), CRI >/= 70, luminous flux (total lumen) >/= 9,000 Lm, system efficacy >/= 100 Lm/W, color temperature: 5,000-6,500K, PF >/= 0.90, life span of LED >/= 50,000 burning hours, IP 65 or better, BIS CRS compliant, having inbuilt protection against short-circuit, overload, over-voltage, reverse-polarity etc. works on 220-230V AC, 50Hz power supply with accessories suitable for street / girder lighting. (Make as per Annexure-I) | — | 2.00 | — | — | |
| — | — | — | Above/ 441.42 Below/P | ||
| Installation, connection, testing and commissioning of LED street/girder light of different capacity including all accessories and old fittings are to be removed, if any.(N.B: All materials required during execution of work and connection are to be supplied by the firm.) | — | 2.00 | — | — | |
| — | — | — | Above/ 9658.86 Below/P | ||
| Supply of earth pipe made from 50mm (or above) nominal bore (dia.) heavy duty GI pipe, 3 mtr. (minimum) long and digging, insertion, testing and commissioning of earth pipe including construction of earth pit. Each pit should be provided with 2 Nos. of above pipe duly shorted by suitable length of GI flat (50mm x 6mm) including necessary earth connection from pit to the electrical assets with 4 SWG (or thicker) GI wire. Alternate layer of salt and charcoal are to be spread inside the pit. Earth pit shall be completed with necessary civil work like brick chamber, PCC work & finally covered with medium duty cast iron hinged cover of suitable size (make of GI pipe as per Annexure-I).N.B.: The earthing should be done as per CEE/KKK's specification. All earth value should be marked on MS plate with date by painting work and MS plate should be fixed with earth pit or nearby wall properly by suitable size nuts and bolts. The MS flat, plate should be painted by one coat of red oxide and 2 coats of black paint before execution. The marking should be done by white paint. | for details. | Breakup | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022.pdf
ATTACHMENT
AdvancecorrectionslipsofGCC2022.pdf Advance Correction slips of GCC
ATTACHMENT
TenderDocument.pdf
ATTACHMENT
Scheduleofwork.pdf
ATTACHMENT
MakeAnnexure-I.pdf
ATTACHMENT
GeneralSpecification.pdf
ATTACHMENT
checklist.pdf
ATTACHMENT
Annexure-IaIbIIIIIVVA.pdf
ATTACHMENT
Annexure-IVVIVIAVIIVIII.pdf
ATTACHMENT
SharamikKalyalSpecialCondition.pdf
ATTACHMENT
AdvancecorrectionslipsofGCC2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .