Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹20.9 LAdmitted-Finance | -30.00% | ₹20.9 L | L1 | Admitted-Finance |
| 2 | L2₹26.6 LAdmitted-Finance | -11.00% | ₹26.6 L | L2 | Admitted-Finance |
| 3 | L3₹27.5 LAdmitted-Finance | -7.77% | ₹27.5 L | L3 | Admitted-Finance |
| 4 | L4₹28.4 LAdmitted-Finance 25 PRATAP COMPLEX GULAB SINGH MARG JAMMU | -5.00% | ₹28.4 L | L4 | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical GANESH VIHAR KHASRA NO 178 MIN OLD 59 NEAR ANGAD BANQUET HALL CAMP ROAD JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | - | - | - | Not Admitted-Fee/PreQual/Technical Others-ITR 2023-24 and 2024-25 not uploaded |
Tender Value
₹29.9 L
EMD Value
₹59,719
Closing Date
23 Feb 2026, 12:00 pmClosed
Executive Engineer (E) JMC
Town Hall, Jammu
LED Retrofit Replace fused streetlights Globe lights with New lights in parks within JMC limits
2026_HAUDD_303512_1
Electric Division JMC Fresh e-NIT No. 40 ELC of 2025-26
Open Tender
Electrical Works
JMC Wards.
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Yes
Executive Engineer (E) JMC
₹59,719
Yes
24 Feb 2026
16 Feb 2026
23 Feb 2026
16 Feb 2026
23 Feb 2026
16 Feb 2026
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI 3>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge asper requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 72 Watt
16 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type
10 mm² Cable (4C) from LT Line to meter,1.1kV Grade, Armoured,PVC Insulated Stranded Conductor FRLS type
1.1 kV 2C x 6 sq mm Aluminium Unarmoured PVC Cable
Supply and fixing of following size of medium class PVC conduit 1" dia along with Accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required (Reputed make ISI mark 25 mm)
Supplying installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars /Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status, I/c programming at site complete as required.01 output per phase and suitable for single phase supply. (as per the direction of Engineer Incharge)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing following rating, double pole, 240 V, Isolator / SPN in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, 240 V, Isolator /SPN in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supply and fixing of water proof junction boxes outdoor type suitable for hosting MCBs etc.
Supply and fixing of Aluminium Thimble, Ferrule/Lugs for cable of 16 Sq. mm (Reputed Make)
Earthing with GI. earth plate 600 mm x 600mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. ( with charcoal/ coke and salt) as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N
FEEDER PILLAR 1 phase 2 wire, 415V, 1nos of 100 Amps incoming SP MCCBs fitted with outgoing 04 No 32 Amps SP MCBs for Service Connections, Distribution Service Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars 2P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accessories 4 way Distribution Service Pillar. Support Galvanised angle frame and legs (40mm x 40 mm x 3mm) for Distribution Feeder Pillar with leg height 1m with 0.3m in soil approx [email protected] per mtr, Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.Cement grouting for support angle legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage and Handling , 3% Contingency and safety equipments, 0.5% Insurance) and Turnkey factor @25%
1:4:8 (1 cement : 4 manufactured sand derived from 8 graded stone aggregate 40 mm nominal size
Supply and laying of sand cushion
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.01 MB
BOQ_985524.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid