Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3,400Qualified Make: NA
Model: Surgeon's Solution A1 DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110094 INDIA | NORTH EAST DELHI | DELHI | 110094 | Make: NA
Model: Surgeon's Solution | L1 | Qualified | |
| 2 | Disqualified Make: BPL
Model: KDS 5G 8 5G 8 GURUDWARA ROAD NIT FARIDABAD HARYANA 121001 | FARIDABAD | HARYANA | 121001 | Make: BPL
Model: KDS | - | Disqualified | |
| 3 | Disqualified Make: BPL MEDICAL TECHNOLOGIES PVT LTD.
Model: BPL SMART OXI LITE 2ND FLOOR T S TOWER ASHOK MARG LUCKNOW LUCKNOW UTTAR PRADESH 226001 | LUCKNOW | UTTAR PRADESH | 226001 | Make: BPL MEDICAL TECHNOLOGIES PVT LTD.
Model: BPL SMART OXI LITE | - | Disqualified | |
| 4 | Disqualified Make: choiceMMed
Model: MD300C20 KESAR NAGAR MUHANA MANDI ROAD JAIPUR RAJASTHAN 302020 INDIA | JAIPUR | RAJASTHAN | 302020 | Make: choiceMMed
Model: MD300C20 | - | Disqualified | |
| 5 | Disqualified Make: NA
Model: LAHER OXY TOUCH 304 SF MILLENIUM APARTMENTS WARD NO 2 MEHRAULI SOUTH WEST DELHI DELHI 110030 | SOUTH DELHI | DELHI | 110030 | Make: NA
Model: LAHER OXY TOUCH | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Aug 2018, 11:00 amClosed
pulse oximeter units line powered Pulse Oximeter Units Line Powered ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Descriptions GMDN name and Code Pulse oximeter CT 1446 * "Pulse Oxymeter
line Powered:A mains electricity (AC- powered) photoelectric device intended for the continuous transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2) The signals
typically produced by light-emitting diodes (LEDs) and a receiving detector in a probe
or directly built-in
are used to make the measurements using the principle of spectrophotometry The oximeter displays the SpO2 values and may calculate/display other parameters
e g
yes * 1/4 pulse rate
electrocardiogram (ECG) The device is typically used at the bedside " SpO2 measurement range at least 40-70 and 70 to 99 %
minimum gradation 1% yes * Power consumption 220 * power input and frequency 220 to 240V
50 Hz * Accuracy of pulse rate better than ± 5 bpm yes * Audiovisual alarms required: high and low SpO2 and pulse rate (operator variable settings)
sensor disconnected
sensor failure
low battery yes * Display type TFT Screen * Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes * Mobility
portability Protective splashproof case for clean storage and safe transport * Operating condition:Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes * weight (gram) 300 1-4000 Others: List of important spare parts and accessories with their part number
Certificate of Calibration and Inspection to be provided provided as per demand * STANDARDS AND SAFETY:Should be FDA yes * 2/4 CE approved product ISO 80601-2-61-2011: Medical Electrical equipment- part 2-61: Particular requirements for the basic safety snd essential performance of pulse oxymeter Electrical safety conforms to standards for electrical safety IEC-60601-1
EMC safety confirms to IEC 60601-1-2 standard requirement; Manufacturer/supplier should have ISO 13485 certificate for quality standard Electrical safety conforms to standards for electrical safety IEC-60601-1 Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility) and IEC 60601-2-25 (essential performance of electrocardiographs) Accuracy of SpO2 better than ± 1% for range 40-70 and better than ± 3% for range 70-99 yes * Pulse rate range at least 30 to 240 bpm
minimum gradation 1 bpm yes * Power cable length (meter) 3 * Signal strength or quality to be visually displayed yes * Memory Minimum 24 hrs trend memory for SpO2 & PR * Noise Level (dB) 9 Any applicable numeric value User's interface Easily accessible touch button to operate the machine * Inbuilt Software and/or standard of yes * 3/4 communication Display must allow easy viewing in all ambient light levels yes * Electrical protection provided by fuses in both live and neutral supply lines yes * Warranty Warranty 3 years warranty & one year with min. 3 free servicing. * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Viswajit Debnath 486889
CENTRAL HOSPITAL NCL HEADQUARTERS PO - SINGRAULI MADHYA PRADESH 486889 2 30
515586
GEM/2018/B/73155
pulse oximeter units line powered
30 days
Madhya Pradesh; Singrauli
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| pulse oximeter units line powered Pulse Oximeter Units Line Powered ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Descriptions GMDN name and Code Pulse oximeter CT 1446 * "Pulse Oxymeter | - | - | - |
| line Powered:A mains electricity (AC- powered) photoelectric device intended for the continuous transcutaneous measurement and display of haemoglobin oxygen saturation (SpO2) The signals | - | - | - |
| typically produced by light-emitting diodes (LEDs) and a receiving detector in a probe | - | - | - |
| or directly built-in | - | - | - |
| are used to make the measurements using the principle of spectrophotometry The oximeter displays the SpO2 values and may calculate/display other parameters | - | - | - |
| e g | - | - | - |
| yes * 1/4 pulse rate | - | - | - |
| electrocardiogram (ECG) The device is typically used at the bedside " SpO2 measurement range at least 40-70 and 70 to 99 % | - | - | - |
| minimum gradation 1% yes * Power consumption 220 * power input and frequency 220 to 240V | - | - | - |
| 50 Hz * Accuracy of pulse rate better than ± 5 bpm yes * Audiovisual alarms required: high and low SpO2 and pulse rate (operator variable settings) | - | - | - |
| sensor disconnected | - | - | - |
| sensor failure | - | - | - |
| low battery yes * Display type TFT Screen * Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes * Mobility | - | - | - |
| portability Protective splashproof case for clean storage and safe transport * Operating condition:Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes * weight (gram) 300 1-4000 Others: List of important spare parts and accessories with their part number | - | - | - |
| Certificate of Calibration and Inspection to be provided provided as per demand * STANDARDS AND SAFETY:Should be FDA yes * 2/4 CE approved product ISO 80601-2-61-2011: Medical Electrical equipment- part 2-61: Particular requirements for the basic safety snd essential performance of pulse oxymeter Electrical safety conforms to standards for electrical safety IEC-60601-1 | - | - | - |
| EMC safety confirms to IEC 60601-1-2 standard requirement; Manufacturer/supplier should have ISO 13485 certificate for quality standard Electrical safety conforms to standards for electrical safety IEC-60601-1 Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility) and IEC 60601-2-25 (essential performance of electrocardiographs) Accuracy of SpO2 better than ± 1% for range 40-70 and better than ± 3% for range 70-99 yes * Pulse rate range at least 30 to 240 bpm | - | - | - |
| minimum gradation 1 bpm yes * Power cable length (meter) 3 * Signal strength or quality to be visually displayed yes * Memory Minimum 24 hrs trend memory for SpO2 & PR * Noise Level (dB) 9 Any applicable numeric value User's interface Easily accessible touch button to operate the machine * Inbuilt Software and/or standard of yes * 3/4 communication Display must allow easy viewing in all ambient light levels yes * Electrical protection provided by fuses in both live and neutral supply lines yes * Warranty Warranty 3 years warranty & one year with min. 3 free servicing. * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Viswajit Debnath 486889 | - | - | - |
| CENTRAL HOSPITAL NCL HEADQUARTERS PO - SINGRAULI MADHYA PRADESH 486889 2 30 | - | - | - |
Exempted
31 Aug 2018
24 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_515586.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .