Loading…
Loading…
Tender Value
₹4.9 Cr
EMD Value
₹9.9 L
Closing Date
24 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT.GEN.
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB(available in GCC), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Calculation of required minimum average annual contractualturnover:V=Rs.49471025 , N=6 months = 0.5 years, V/N=Rs.49471025/0.5 =RS.98942050, V is less than V/N, Hence, required minimum average annual contractual turnover = Rs.49471025
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: (1) Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate
Defination of Similar Work :- Electrification / Rewiring of Service or Residential building / Yard / HT / LT substation work / HT / LT cable work / street lighting / platform or building lighting management / circulating area Lighting / Electrical overhead power supply work / Electrical pump work etc.
13 conditions · 7 needing a document upload
The registration of contractors working under Railway departments with ESIC is mandatory (if applicable as per current Law / Act)
In case a tenderer is participating as Sole Proprietor in a tender, it is mandatory for him to submit an undertaking on suitable stamp paper to this effect clearly mentioning PAN number also along with tender document at the time of submission of tender.
The tenderer may submit scanned copy of partnership deed if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor shall ensure all precautions during digging work close to Rly signaling, telecom electrical cables etc. Penalties to be imposed for damages to any cable as per Railway board letter no. 2021/Tele/5(2)/3- Part(1)/(3425647) dtd 12.06.2023
Electrification work in connection with leftover portion of Automatic Block Signalling work in Jalgaon-Chalisgaon & Chalisgaon-Manmad section of Bhusawal Division.
BSL-L-W-T-72-2026
BSL-L-W-T-72-2026
Open
Works - General
6 Months
Jalgaon, Maharashtra
₹0
₹9.9 L
24 Aug 2026
31 Jul 2026
10 Aug 2026
74 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,94,71,025 | ||
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of Three Phase Lighting Circuit Board, Double Door Powder coated with locking arrangement consisting 63 A 4P MCCB as I/C and 9 Nos x 6 A 2P RCBO and 3 Nos x 20A 2P RCBO as O/G complete. | — | — | — | 14,37,723 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Outdoor type LT panel as per IEC 61439 with double door powder coated consisting of 2 Nos x 125 A MCCB as I/C & 1 Nos x 125 A 4P onload change over switch, 2 Nos x 63 A 4P MCCB, 4 Nos x 32 A 4P RCBO, 2 Nos x 63 A 2P RCBO, 2 Nos x 16 A 2P RCBO as O/G along with Digital timer with microcontroller based, ELR with CBCT for each MCCB, Power quality analyser, Multifunctional meter, indication lamp, Copper Busbar and all other associated accessories. All MCCB are Microprocessor based (completely wired with suitable communication cable to fetch data from each compartment functional Unit (ACB/MCCB/SFU etc) / Multifunction Meter) | — | — | — | 1,26,65,343 | |
| — | Breakup | for details. | — | ||
| Supply, fabrication, fixing and erection of MS Work of miscellaneous size and for cable tray etc. including painting complete. | — | — | — | 2,14,000 | |
| — | Breakup | for details. | — | ||
| Supply, fabrication, laying welding and connection of GI Flat of size 25x3 mm from earth pit with GI nut Bolt suitable size. | — | — | — | 2,28,000 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of maintenance free earth as per RDSO specification no. RDSO/PE/SPEC/ PS/0109-008(REV '0') with improved earthing enhancing compound and exothermic welding | — | — | — | 24,77,145 | |
| — | Breakup | for details. | — | ||
| Supply of Digital Megger 2500 V. | — | — | — | 1,44,190 | |
| — | Breakup | for details. | — | ||
| Supply of Digital Clamp on Earth Tester. | — | — | — | 5,87,340 | |
| — | Breakup | for details. | — | ||
| Supply of Digital Clamp on Meter (Tong Tester). | — | — | — | 62,420 | |
| — | Breakup | for details. | — | ||
| Supply of Aluminium telescopic ladder, heavy duty with holding rubber, foldable with equal steps, 12 to 13 Feet height with push button type system ladder | — | — | — | 1,31,271 | |
| — | Breakup | for details. | — | ||
| Analog Earth Tester, 4 terminal (Dual Range), metal Body, and Rated Ohms 0-10-100 Ohms, as per IS Specification 9223/1989 suitable for measuring Earth Resistance along with accessories -- 4 Nos. M.S. spikes, (Not less than 15 mm diameter and 750 mm in length with suitable terminal in one end and tapering at the other end). -- 4 Nos. reels of flexible wire, hammer, 1 No. high quality canvas bag/carrying case. | — | — | — | 74,190 | |
| — | Breakup | for details. | — | ||
| "Supplying and erecting metal clad changeover switch 2 pole, 240 V, 32A erected on provided angle iron/GI frame and duly connected with suitable wire leads complete as per specification." | — | — | — | 31,863 | |
| — | Breakup | for details. | — | ||
| Supply of Insulation paint and painting of Octagonal poles / tubular poles/High Mast with 03 coats of insulation paint so as to achieve 05 KV insulation. The work also includes cleaning and scrubbing of pole before application of paint. Upon testing no leakage current should be found upon the painted surface | — | — | — | 43,24,000 | |
| — | Breakup | for details. | — | ||
| Supply of Insulation tape and application of the insulation tape on Octagonal poles / tubular poles/High Mast so as to achieve 05 KV insulation. The work also includes cleaning and scrubbing of pole before application of paint. Upon testing no leakage current should be found upon the painted surface. {1 Per Unit = 1 Roll of 5.0 CM (Width) x 33 M (Length)} | — | — | — | 2,18,820 | |
| — | Breakup | for details. | — | ||
| PVC insulated & sheathed 3 core flexible copper cable size 0.75 sq mm | — | — | — | 1,28,000 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of PVC Flexible pipe 1/2 Inch | — | — | — | 9,000 | |
| — | Breakup | for details. | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification | — | — | — | 1,05,100 | |
| — | Breakup | for details. | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification | — | — | — | 1,27,250 | |
| — | Breakup | for details. | — | ||
| Provision of Cable Jointing Kit suitable for 16/25 sqmm cable | — | — | — | 4,91,300 | |
| — | Breakup | for details. | — | ||
| Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification | — | — | — | 3,27,200 | |
| — | Breakup | for details. | — | ||
| Supply of 4 core 16 sqmm armoured XLPE Cable. | — | — | — | 23,37,500 | |
| — | Breakup | for details. | — | ||
| Supply of 4 core 25 sqmm armoured XLPE Cable. | — | — | — | 31,72,000 | |
| — | Breakup | for details. | — | ||
| Supply of LT XLPE Armoured 4 Core 50 Sqmm Aluminium cable as per relevant IS. | — | — | — | 56,37,500 | |
| — | Breakup | for details. | — | ||
| Trenching & refilling of LT/HT/ Various sizes of PVC / XLPE cables- Along the Road (Size - 900mm x 300mm) | — | — | — | 67,52,000 | |
| — | Breakup | for details. | — | ||
| Digging of cable trench 300/450 mm x 1000 mm in RCC/PCC/hard soil & refilling as per specification and requirement at the site. | — | — | — | 14,72,000 | |
| — | Breakup | for details. | — | ||
| Transportation, Laying, Installation, terminating, testing and commissioning of LT/HT cable of sizes 10 sqmm to 400 sqmm in existing trench, pipe or on structure. | — | — | — | 10,80,000 | |
| — | Breakup | for details. | — | ||
| Erection,testing and commissioning of cables other than trench i.e.Wall/Truss including clamp, GI wire and hardware | — | — | — | 1,44,000 | |
| — | Breakup | for details. | — | ||
| Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as per technical specification & drawing for passing cable. | — | — | — | 40,400 | |
| — | Breakup | for details. | — | ||
| Supply,installation, testing & commissioning of HDPE Pipe 110 mm Nominal Dia as per IS-4984-1995. | — | — | — | 3,00,000 | |
| — | Breakup | for details. | — | ||
| Supply and laying of RCC half round pipe 150 mm ID & 1 mtr length. | — | — | — | 33,98,880 | |
| — | Breakup | for details. | — | ||
| Supply and laying of RCC Hume Pipe of size 6"(150mm) dia 2 mtr. Length. | — | — | — | 1,35,900 | |
| — | Breakup | for details. | — | ||
| Supply, erection of RCC Type cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. | — | — | — | 3,59,280 | |
| — | Breakup | for details. | — | ||
| Supply & Erection of RCC Warning Cover and refilling the cable trench in an approved manner. | — | — | — | 3,40,560 | |
| — | Breakup | for details. | — | ||
| Supply & Erection of SPN 8 way Double door DB | — | — | — | 52,900 | |
| — | Breakup | for details. | — | ||
| Supplying, fixing and commissioning 2 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 1,87,550 | |
| — | Breakup | for details. | — | ||
| Supplying, fixing and commissioning 4 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indications per specification | — | — | — | 2,39,650 | |
| — | Breakup | for details. | — | ||
| Supply capacity | — | — | — | 36,750 | |
| — | — | & Erection of 6/10/16/20/25/32A, | with 10KA |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022dt.27.04.2022.pdf GCC 2022
ATTACHMENT
ACS1to6ofGCC.pdf
ATTACHMENT
ACS7to10ofGCC.pdf
ATTACHMENT
ACS11toGCC2022.pdf
ATTACHMENT
Tenderdocument.pdf
ATTACHMENT
GCCApril2022dt.27.04.2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .