Loading…
Loading…
Tender ID
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
14 Mar 2026, 2:00 pmClosed
xen js phe mech div north jammu
office of the xen js phe mech div north jammu
Providing, installation, testing and commissioning of HC Pump set having specification 50000 GPM x 150mtrs. Head along with allied works at CPS Roop Nagar Stage II for pumping water to CPS Roop Nagar stage III Under SASCI Scheme.
2026_PHE_304326_1
e nit no. 123 of 2025-26
Open Tender
Repair and Maintenance Works
Item Rate
90 days
CPS ROOP NAGAR
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
Yes
office of the xen js phe mech div north jammu
₹50,000
Yes
02-03-2026
16 Mar 2026
24 Feb 2026
16 Mar 2026
24 Feb 2026
14 Mar 2026
5 Mar 2026
2 Mar 2026
Providing, installation, testing & commissioning of HC Pump set having specification 50000 GPM x 150mtrs. Head along with allied works at CPS Roop Nagar Stage II for pumping water to CPS Roop Nagar stage III. Providing of split casing HC pump having specifications 50000 GPM x 150 Mtrs. head coupled with low-speed squirrel cage motor, along with base frame, coupling pulley, coupling guard and other allied accessories. Laying of RCC foundation block: Job includes excavation of earth work for laying of RCC foundation block by way of dismantling of old foundation blocks with the help of required tool and tackle and manual labour as per site requirement. Disposing off the excavated material from the site to a distance of at least 0.2 Km with the help of manual labour and mechanical transport. Job includes digging of pit size 8'X3.5'X6' and disposal of excavated material from the site of the work to the place of dumping. Providing and fixing of 25 mm dia. x 1 meter long 8 Nos. foundation bolts fabricated out of MS round having 150 mm long threading on one side and other side forming “J” shape. Properly placing of foundation bolts in position along with base plate and properly anchoring the bolts with steel mesh by welding with special welding electrodes. Providing/Laying of RCC foundation block of size 8'X3.5'X6' (1' above the ground level) in 1:2:4 cement concrete mix having requisite reinforcement with 12 /14/16 mm dia. tor steel from centre to centre having mesh of size 6” spacing (approx.), then leave the foundation block for curing purposes for at least five days. Fitting of base frame plate on the top of the block and levelling it both horizontally as well as vertically. Then plastering and finishing from outside. Job includes fitting of Pump on the base frame then complete job includes cost of material and labour charges for laying of the foundation block, plastering and finishing. Installation: Shifting the pump set to site of work using crane and manual labour. Placing the pump and installation and motor on the base frame by using crane,skilled manpower and tools and tackles. Levelling of pimp and motor properly making alignment of pump and motor on base frame and fastening with base frameafter P/F of superior quality hexagonal fasteners with washers. Suction Line:Providing, fabrication and laying of MS 150 mm suction pipeline to pump by providing of pipe, fabrication of bends and flanges as per required lengths and quantity and welding jointing of flanges with existing pipe then providing and fitting of 150 mm sluice valve (CS). P/F of 150mm flanges, jointing material, industrial gases, welding rods etc. and labour charges for earth work excavation, to and fro carriage of tools, tackles, material and their manual handling etc. Delivery Line:Providing, fabrication and laying of MS 125 mm delivery pipeline to pump with providing of pipe, fabrication of bends and flanges etc. as per required length. Providing and fitting of 125 mm sluice valve, 125 mm reflex valve etc (all valves are of material CS) . and making inter-connections with the existing rising main including cost of material required. Complete job includes cost of material like sluice valve and reflex valve each, bends along with other fitting materials. Painting: Scratching off rusted portion by emery papers on both newly laid suction and delivery pipes and making an even surface for painting of the pumping equipment. Painting of all the suction , delivery pipes with one coat of red oxide and then painting of all the pumping equipment with two coats of synthetic enamel i.e. suction delivery, sluice valves, reflux valve etc. Job including cost of material and labour charges. (Complete job). The job also includes loading and carriage of materials i.e. H.C. pump along with motor and allied accessories, laying of block along with material and labour, MS pipe for delivery and suction lines along with fabrication of bends, flanges, valves etc., painting of delivery and suction lines, installation of pump set and testing on full load. Complete job. Carriage and Servicing. LT Control Panel-1no:- Providing, Installation, testing and commissioning of LT. Control Panel suitable for HC motor ( 415 volts, AC-3 Phase, 50 Hz. and fitted with the following components viz. M.C.C.B. (should be fitted with an M.C.C.B. of 400 Amp, 1 no. volt meter, 1 no ammeter (0-500 amp with CT), 1 No. V.S.S., 1 No. A.S.S. and a set of RYB indicators at incoming side), Star delta Starter (should be fitted with a fully automatic star delta starter comprises of 3 Nos. contactors (400 Amp – 02 no. and 300 Amp-01no. for star delta operation), Sd. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, indicators , MCB of suitable Amps. for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables to complete the star delta circuit of outgoing supply),Protections device / fault analyzer (should be fitted with capability to protect the motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings) Voltage related fault(Single phasing, under voltage, over voltage, unbalance voltage, Current related fault (over current / load, dry running, unbalance current / load, earth leakage, short circuiting. Bi-metallic overload relay (A bimetal over load relay of suitable range should be fitted with in the starter as an extra protection to protect the motor in case of failure of fault analyzer. fitting of copper cable 95 sq mm single core (six leads of 15 mtrs. each) for making proper connections of the motor with the L.T. Control Panel by proper copper thimbling and insulation of the conductor joints with high quality PVC Tape. Complete testing of the motor on the no load and on the full load .The panel shall be dust and vermin proof fabricated out of 14/16 SWG CR sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. Complete job
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.50 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 10.17 MB
BOQ_988720.xls
BOQ • 0.26 MB
corrigendum123.pdf
PDF • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .