| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC PULGAON | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹15.4 L+₹59,317 (4.00%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹15.6 L+₹73,946 (4.99%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹16.0 L+₹1.1 L (7.70%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | MUKTI ENTERPRISES L2 | M/S Maa Durga Constructions,Pulgaon L1 | SHUBHAM SALES L4 | M/S JAI BHAWANI CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully old unserviceable Refrigerator of capacity 165/175/185/200 Ltrs of any make, burnt out sealed unit compressor by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically & electrically, of any make and keeping a side for further disposal as directed by Engr-in-Charge.
Note :- (i) Job also include removing AC from any site/height/location and transporting AC unit to repair in workshop and back to site if necessary.(ii) Replacement of spares shall be measured and paid separately as supply only and fixing is deemed to be included under this item. | 2 | Each | 1,900 ₹3,800 | 135 ₹270 Lowest | 170 ₹340 | 147 ₹294 |
| 2.00 | All as per item no.1 above but Refrigerator of capacity 240/286/300/315 Ltrs of any make | 2 | Each | 4,000 ₹8,000 | 135 ₹270 Lowest | 170 ₹340 | 150 ₹300 |
| 3.00 | All as per item no.1 above but Water cooler of capacity 40/80 Ltrs of any make. | 6 | Each | 6,100 ₹36,600 | 200 ₹1,200 | 195 ₹1,170 | 174 ₹1,044 Lowest |
| 4.00 | All as per item no.1 above but Deep Freezer of capacity of 310/500Ltrs of any make. | 1 | Each | 7,400 ₹7,400 | 200 ₹200 | 195 ₹195 | 174 ₹174 Lowest |
| 5.00 | All as per item no.1 above but Window type & split type AC of capacity 1.5/2 TR of any make | 3 | Each | 6,900 ₹20,700 | 300 ₹900 | 275 ₹825 | 155 ₹465 Lowest |
| 6.00 | S&F new sealed unit compressor of approved make and capacity 230 VAC all as specified and directed by Engn-In -Charge for Refrigerator of capacity 165/175/185/200 Ltrs of any make. | 2 | Each | 5,400 ₹10,800 | 4,500 ₹9,000 | 4,300 ₹8,600 Lowest | 5,550 ₹11,100 |
| 7.00 | All as per item No 6 above, but for Refrigerator of capacity 240/286/300/315 Ltrs of any make | 2 | Each | 4,300 ₹8,600 Lowest | 5,000 ₹10,000 | 4,450 ₹8,900 | 6,550 ₹13,100 |
| 8.00 | All as per item No 6 above, but for Compressor for water cooler of capacity 40/80 Ltrs | 6 | Each | 5,800 ₹34,800 Lowest | 14,000 ₹84,000 | 16,850 ₹1,01,100 | 15,000 ₹90,000 |
| 9.00 | All as per item No 6 above, but for Deep Freezer of capacity of 310/500Ltrs of any make. | 1 | Each | 8,800 ₹8,800 Lowest | 12,000 ₹12,000 | 14,000 ₹14,000 | 13,000 ₹13,000 |
| 10.00 | All as per item No 6 above, but for Compressor for Window type & split type AC of capacity 1.5 TR | 3 | Each | 10,000 ₹30,000 Lowest | 16,000 ₹48,000 | 18,000 ₹54,000 | 16,500 ₹49,500 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
5 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON CAD PULGAON 442304
REPAIRS / MAINT OF SUMMER APPLIANCES EQPT AND OTHER CONNECTED ITEMS UNDER GE PULGAON
2025_MES_719687_1
8243/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE PULGAON
₹30,000
Yes
8 Oct 2025
10 Jul 2025
11 Aug 2025
10 Jul 2025
5 Aug 2025
24 Jul 2025
10 Jul 2025 - 23 Jul 2025
Amount
Taking down carefully old unserviceable Refrigerator of capacity 165/175/185/200 Ltrs of any make, burnt out sealed unit compressor by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically & electrically, of any make and keeping a side for further disposal as directed by Engr-in-Charge. Note :- (i) Job also include removing AC from any site/height/location and transporting AC unit to repair in workshop and back to site if necessary.(ii) Replacement of spares shall be measured and paid separately as supply only and fixing is deemed to be included under this item.
All as per item no.1 above but Refrigerator of capacity 240/286/300/315 Ltrs of any make
All as per item no.1 above but Water cooler of capacity 40/80 Ltrs of any make.
All as per item no.1 above but Deep Freezer of capacity of 310/500Ltrs of any make.
All as per item no.1 above but Window type & split type AC of capacity 1.5/2 TR of any make
S&F new sealed unit compressor of approved make and capacity 230 VAC all as specified and directed by Engn-In -Charge for Refrigerator of capacity 165/175/185/200 Ltrs of any make.
All as per item No 6 above, but for Refrigerator of capacity 240/286/300/315 Ltrs of any make
All as per item No 6 above, but for Compressor for water cooler of capacity 40/80 Ltrs
All as per item No 6 above, but for Deep Freezer of capacity of 310/500Ltrs of any make.
All as per item No 6 above, but for Compressor for Window type & split type AC of capacity 1.5 TR
Taking out old unserviceable thermostat and S&F new thermostat of approved make and suitable size & model for the Auto defrost thermostat with knob /Bimetal thermostate with heater Assembly for any size of refrigerator.
All as per item no.11 above but Thermostate for any capacity water cooler
All as per item no.11 above but Thermostat with knob for window AC.
All as per item no.11 above but Thermostat with knob for suitable for deep freezer of any capacity
Taking out old unserviceable relay unit and supply and fix new relay kit/PTC relay as per sample for any capacity refrigerator and deepfreezer.
Taking out old unserviceable relay kit and S&F new relay kit (OLP + LMS relay or box type) as per sample for water cooler, No 412Y/512Y or equivalent
Taking out old/burnt starting capacitors of 220V,50 Hz and S&F new starting capacitor having starting range 40 to 120 MFD for water coler all as specified and directed.
Taking out old/burnt running capacitors and S&F new running capacitors of Running capacitor 10/15/25 MFD for any capacity water cooler and refrigerator
All as per item no.18 above but Running capacitor 36 MFD for any capacity window Acs
All as per item no.18 above but Running capacitor 45+4/55+6 MFD for any capacity split Acs
Taking out old/burnt fan motor capacitors and S&F new fan motor capacitors 4MFD/6 MFD suitable for Split AC,Window AC,Desert Cooler complete all as specified and directed
M&L in replacement of unserviceable/leakage Evoporator cooling coil complete suitable for Refrigerator of capacity 286/300/ Ltrs existing model of refirigerator complete all as specified and directed
S&F in replacement evaporator freezer assembly for single door refrigerator up to 210 Ltr capacity of any make & capacity as specified and directed.
S & F new door gasket in replacement of old unserviceable door gasket of Deep Freezer of any capacity
M&L in replacement of broken door panel gasket including door switch complete suitable for existing model of refrigeratior of any capacity
M&L in replacement of vegetable tray complete suitable for existing model of refrigrator of any capacity
M&L in replacement of chiller tray complete suitable for existing model of refrigerator of any capacity.
M&L in replacement of bulb pintype/thread type suitable for existing model of refrigerator of any capacity.
S&F in replacement gas drier filter suitable for refrigerator ,water Cooler deep Freezer Split AC ,window AC of any make & capacity complete all as secified and directed.
S&F in replacement copper capillary tube size 31 gauge for refrigerator/Deepfreezer as specified & directed.
S&F in replacement copper capillary tube size 36 gauge . for refrigerator/Deepfreezer as specified & directed.
S&F in replacement copper capillary tube size range 40 to 55 gauge suitable for water Cooler as specified & directed.
S&F in replacement copper capillary tube size range 60 to 70 gauge suitable for Split/window AC as specified & directed.
S & F in replacement copper pipe ½” dia, wall thickness 0.032 mm including insulation complete all as specified & as directed.
All as per item No 34 above but copper pipe 1/4" dia, wall thickness 0.030 mm .
All as per item No 34 above but copper pipe 5/16" dia, wall thickness 0.035 mm .
All as per item No 34 above but copper pipe 5/8" dia, wall thickness 0.035 mm .
All as per item No 34 above but copper pipe 3/8" dia, wall thickness 0.035 mm .
S&F in replacement electronic timer circuit/ manual timer for double door refrigerator of any make & capacity as specified and directed.
S&F in replacement electronic power supply control PCB for double door refrigerator of any make & capacity as specified and directed.
S&F in replacement evaporator fan motor for double door refrigerator of any make & capacity as specified and directed.
M&L in replacement of broken top door panel gasket complete suitable for existing model of water cooler of any capacity
M&L in replacement of burnt out condenser fan motor, single shaft 1/35, HP capacity, single phase, 230 VAC for water cooler
M&L in replacement of UNSV push cock of SS, 15 mm dia for water cooler.
M&L in replacement of UNSV stop cock, 15 mm dia for water cooler.
S&F fan blade (As per sample) in replacement for water cooler/ deep freezer/refrigerator of any capacity
Taking out old unserviceable/broken float valve & S & F new float valve complete for water cooler of any capacity
M&L for repair/replacement of corroded bottom portion of the water cooler of any make & capacity with MS angle iron of suitable size as per existing, including welding/brazing with MS sheet 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as directed by Engineer-in-charge
M&L for replacement of old wornout/burnt wiring of water cooler/ deep freezer/refrigerator by using copper conductor wire PVC sheathed of suitable size and length complete all as directed by Eng-in-charge.
All as per item No. 49 above but for window/split type A/C of any capacity .
S & F in replacement of electronic circuit (PCB) Original / Assembled (External type) complete including controlling unit i.e. (remote) all as per existing system and suitable for 1.5/2.0 TR capacity split type / window AC compatible with all AC's Brands in original position as per specified and directed by engineer-in-charge.
Taking out burnt/unserviceable fan/blower motor of window type AC of any type & capacity and S&F new fan/blower motor double shaft single/double speed, single phase, 230 V , AC of 1/4HP, 1/5HP, 1/6HP or any other capacity as required complete, making suitable fixing arrangment for existing place (as per sample) Make - AUE/Fracmaster/Popular
S&F fan blade (As per sample) in replacement for window type AC/split type AC of any capacity
M&L for taking out old broken drain outlet pipe of any type attached to indoor unit of split type AC & S & F new drain outlet PVC pipe 20mm dia from indoor unit to nearest suitable drain outlet for split type AC and water cooler of any capacity as directed by Engineer-in-charge
Servicing only window type AC 1.5/2 TR complete with chemical wash to condenser and cooling coil, cleaning of entire elements of AC, oiling/greasing to motor including taking out & refixing the machine at its original location as directed by Engineer-in-Charge
Servicing only for split type AC of any capacity, including chemical wash or equivalent, to condenser and cooling coil, cleaning the entire parts, oiling/greasing to condenser motor, cooling coil blower motor complete as directed by Engineer-in-Charge.
M&L for disconnecting the water cooler of capacity 40/60 Ltrs/hr from electric and water connection. Cleaning the condensor unit by using carbon tetra chloride cleaning the condensor fins, oiling/greasing the fan motor, checking of alignment of motor cleaning of water storage tank. Fixing back the water cooler and testing all as directed by Eng-in-charge.
M&L for servicing the deep freezer unit completely for trouble free working and satisfactory performance by means of cleaning each part of the machine carefully, greasing/oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and pressure air through blower and cleaning the machine for better working as directed.
M&L for gas charging for Refrigerator of any capacity & make with R-22, R-134(a),R-600 and R-600 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length flare nut, dead plug, dead cap etc. complete with testing and commissioning. Note :- (i) Job includes dismantling equipment from any site height and transporting to workshop if necessary and reinstalled in site and testing. (ii) Job to be guaranteed for minimum one year.
All as per item No 59 above but for Water cooler of any capacity & make
All as per item No 59 above but for Deep Freezer of any capacity & make
All as per item No 59 above but for Window type AC/ Split type AC of 1.5 TR capacity
All as per item No 59 above but for Window type AC/ Split type AC of 2 TR capacity
Taking down unserviceable/damaged/rusted condensor unit of 1.5/2 TR split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor unit consisting of body, motor, condensor & blade suitable for existing dismantled model or equivalent approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after refixing compressor of existing unit as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity
M&L Refrigerator of capacity up to 210 Ltr in replacement of unserviceable/rusted condensor unit complete suitable for existing model of refirigerator for the
All as per item no.65 above but Refrigerator of capacity 286 ltr to 310 Ltrs
S&F in replacement condenser coil complete with copper tube and aluminium fins suitable for deep freezer 200-300 ltrs capacity of any make and necessary welding/bracing work complete all as specified and directed.
S&F in replacement condenser coil complete with copper tube and aluminium fins suitable for water cooler 40/80 ltrs, 60/120 ltrs & 150 ltrs capacity of any make with welding/bracing work complete all as specified and directed.
M&L for replacement of1/4",5/16",1/2" 5/8" and 3/8" nearest tube size insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed by Engineer in charge after taking down old, deteriorated insulation
S&F MCB protected power unit include MCB SP 16A to 25 A ,220V,50 Hz Complete all as specified and directed Make Havells Cat Part No : DHDMCSN0251025
Dismantling the old U/S out door unit of split type AC of cap 1.5 Ton and fixing of the new out door unit complete with condensor coil, cooling coil made of copper coil , blower motor with PVC fan blade ,Wiring Kit,two pole contactor,running and starting capaciter of 40 to 45 MFD capacity including provision of fixing existing compressor & charging refrigerant gas R22 of required quantity including testing on full load all as specified & directed. Note: Charging of refrigerant gas of required quantity to be measured and paid separately
Dismantling the old U/S in door unit of split type AC of cap 1.5 Ton and fixing of the new in door unit complete with cooling coil made of copper, blower motor,swing motor,electonic PCB,Display unit,temprature sensor,box type relay complete with PVC drum & electronic circuits including testing all as specified & directed.
Dismantling the old U/S unit of window type AC of cap 1.5 Ton and fixing of the new unit complete with condensor coil made of copper of suitable size, cooling coil made of copper of suitable size, blower motor with PVC fan blade & PVC drum,electronic PCB,temprature sensor including provision for fixing of existing compressor & charging refrigerant gas R22 of required quantity including testing on full load all as specified & directed. Note: Charging of refrigerant gas of required quantity to be measured and paid separately
S & F in Replacement two pole Contactor up to 30 Amp capacity 230 V,50Hz suitable for split type AC complete all as specified and directed. Make- L&T/Havells / BCH / Siemens / ABB
S & F in Replacement PVC air filter suitable for window/split type AC of any make & capacity.
S & F in Replacement of louver blades synchronous motor/swing motor for 1.5/2 ton window/split type AC indoor unit of any make and capacity as per sample complete all as specified and directed.
S & F in Replacement of electronic display assembly suitable for window/split type air conditioner of any make and capacity as per the sample complete all as specified and directed.
S & F in Replacement of temperature sensor assembly for window/split type air conditioner 1.5/2.0 TR as per sample complete all as specified and directed.
S&F in Replacement of Cooling coil unit suitable for 1.5/2.0 Ton window type AC including welding/bracing work etc of existing model & make complete all as specified and directed.
All as per item No:79 above but cooling coil suitable for 1.5/2.0 Ton split type AC indoor unit .
S & F in Replacement of heavy duty air conditioner outdoor unit mounting bracket/stand suitable for 1.5/2.0TR split Type air conditioner as per sample complete all as specified and directed.
S&F in repair Pin/service valve of size 1/2", 1/4", 3/8", 5/8" suitable for refrigerator,deepfreezer,water cooler and Air conditioner of any make and model complete all as specified and as directed.
Dismantling blower/Condenser fan motor of split type AC of 1.5/2.0 TR capacity and Supply and fixing new fan motor alongwith fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-Charge. Make : Marathon/Crompton/Voltas//GE/Carrier/samsung
S & F new 5Amp pin top in replacement of old broken pin top of any make as directed
S & F new 15Amp pin top in replacement of old broken pin top of any make as directed
Material and labour for repairs/servicing of old desert cooler by dismantling and cleaning completely ,scraping inner & outer side incl flaps to remove old dirt and applying one coat of synthetic enamel paint (inner & outer both surface) of existing colour replacing wood wool pad mimimum 15mm thick from three side, binding with GI wire,assembling and testing including oiling/greasing of fan motor,servicing of water pump etc complete all as directed by EIC
Supply and fix 1800 cfm in repair/replacement fan motor having copper wounded with blade suitable for the following sizes desert cooler SP 230 Volt 50 Hz including commissioning and testing complete all as specified and directed
All as per item no.87 above but 3000 cfm
All as per item no.87 above but 4000/5000 cfm
All as per item no.87 above but 6000 cfm
Supply and fix 1800 cfm in repair fan blade of metal body suitable for the following sizes desert cooler SP 230 Volt 50 Hz including commissioning and testing complete all as specified and directed
All as per item no.91 above but 3000 cfm
All as per item no.91 above but 4000/5000 cfm
All as per item no.91 above but 6000 cfm
Supply and fix 1800 cfm in repair fan blade of PVC body suitable for the following sizes desert cooler SP 230 Volt 50 Hz including commissioning and testing complete all as specified and directed
All as per item no.95 above but 3000 cfm
All as per item no.95 above but 4000/5000 cfm
All as per item no.95 above but 6000 cfm
Supply and fix in repair submersible water pump SP 230 Volt 50 Hz 1.5-2.5 mtr head with PVC 10mm dia flexible hose connected and commissioning and testing complete.
M&L for replacement of PVC water tube and distribution with 3 way PVC connection assembly complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge.
S&F in replacement front grill , double diversion with gril box for control switches,for desert cooler of any make any type made of PGI sheet of 22 gauge complete all as specified and directed.
S&F in replacement two sides and one back sutter having grooves arrangement made by GI sheet of existing shape and size for desert cooler complete all as specified and directed
S&F in replacement of water tank of desert cooler of size not less than 102 cmx102 cmx26 cm (Approx) made from 20 gauge PGI sheet as per site requirement including necessary holes & drain plug complete all as specified and directed.
S&F in replacement of water tank of desert cooler of size not less than 102 cmx85 cm x 20 cm (Approx) made from 20 gauge PGI sheet as per site requirement including necessary holes & drain plug complete all as specified and directed.
Dismantling the old U/S desert cooler and supply & fixing in replacement new cabinet fabricated with 24 gauge GI sheet consisting of three side panels ,front, top and tank ,GI wire net including vertical member , of size not less than 85cm x 60cm x 52 Cm in size with double diversion grills and grill box suitable for not less then 15” sweep fan and making holes with fixing arrangement incl providing 4 way PVC distributor, PVC pipe 1.5 to 2 Mtr for water, wood wool pads , electrical wiring for fan & pump, controlled separately with 5 amp Piano type switch etc water tank and top cover painted with two coat black anti corrosion paing complete all as specified and directed.
Taking out and opening carefully the exhaust fan / kit fan motor of desert coolers of any make / model, cutting and removing old short circuited stator winding complete and rewinding with super enamelled copper winding wire of existing gauge including replacement of unserviceable GM bush , ball bearing, MS Saft, long nuts bolts etc and reasembling complete all as specified and directed.Note:- Repair work will be carried out within 07 day after intimation to contactor on telephonic followed by in writting.Any delay beyound 07 day shall be compensated through panel recovery @ 350 per day/per desert cooler tilltill the date of rectification or repaired fan and deposited in MES store yard .
Supply & fixing wood wool pad mimimum 15mm thick for sides and back shutters of coolers made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire net frame for desert cooler of any make & size.
M&L for replacement of switch assembly complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge.
Supply and fixing in repair cord flexible three core copper conductor multi-stranded 2 mtr long with 5 Amps plug top and connected to the equipment all as specified and directed.
Supply and fixing in repair angle iron frame for mounting fan motor of desert cooler with nut,bolt and all accessoriesall as specified and directed.
Taking down unserviceable/damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil unit of suitable capacity of existing dismantled model or equivalent approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line as directed and testing and commissioning complete for satisfactory performance of unit after gas charging Suitable for 1.5/2 TR capacity, split AC, 230VAC
M&L for replacement of 3 core, 4 sqmm, copper conductor PVC insulated flexible cable from main supply point to out door unit point as directed and specified by Engineer-in-Charge
All as per item No.112 above but 3 core , 2.5 Sqmm
All as per item No.112 above but 3 core , 1.5 Sqmm
S&F in replacement single shaft, blower motor of 1/6,1/8,1/5 HP capacity for split type AC of capacity 1.5/2 TR/Air Curtain of any size complete as directed by Engineer-in-Charge Make - AUE, Fracmaster, Popular
S&F in replacement swing motor for split type AC of any capacity complete as per sample as directed by Engineer-in-Charge
Supply only suitable remote control handset of split type AC of any capacity in replacement of old unserviceable remote control handset of any type as specified and directed.
Supply and Fix in replacement angle valve/service valve of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity as specified and directed.
M&L for taking out the Air Curtain of any size from the wall above the door, cleaning the blower complete, & refixing in position all as per direction of Eng-in-charge.
M&L for cutting the existing window including additions/alterations to make opening suitable for fixing the window type air conditioner including welding/wood work as per site requirement to match with adjoining/existing surfaces and shifting the window type air conditioner to the new altered location/existing including the necessary connections and testing complete all as directed by Engineer-in-charge
Labour only for removing & reinstallation of split type AC 1.5/2TR cap, indoor & outdoor unit including all allied work such as bending, shaping, brazing to copper tubing & insulation to tubing, connection of water drain piping & fixing it properly, etc including testing & commissioning complete.
MUKTI ENTERPRISES (BID ID -3375742)
M/S JAI BHAWANI CONSTRUCTIONS (BID ID -3382863)
SHUBHAM SALES (BID ID -3382043)
Bidder Name
M/S Maa Durga Constructions,Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES
MUKTI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .