Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC L-1 | |
| 2 | L2₹40.3 L+₹1.6 L (4.05%)Rejected-Finance 233 PLATINUM PLAZA OPP IOCL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | L2 | Rejected-Finance L2 Bidder | |
| 3 | L3₹40.7 L+₹2.0 L (5.15%)Rejected-Finance | L3 | Rejected-Finance L3 Bidder | |
| 4 | L4₹41.2 L+₹2.4 L (6.32%)Rejected-Finance | L4 | Rejected-Finance L4 Bidder | |
| 5 | L5₹42.9 L+₹4.2 L (10.8%)Rejected-Finance 1503 SYNERGY BUSINESS PARK SAHAKARWADI VISHWESHWAR RD GOREGOAN EAST MUMBAI MAHARASHTRA 400063 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | L5 | Rejected-Finance L5 Bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
13 Sept 2023, 3:00 pmClosed
Head, Electrical Division
4th Floor, North Wing, DCSEM, DAE, V.S. Bhavan, Anushaktinagar, Mumbai-400094
Providing Electrical works and Landscape Lighting for Sector Market complex at Anushaktinagar, Mumbai.
2023_DCSEM_766618_1
DCSEM/CQD/QSC/ SMC/LS-Elect/NIT-25/23-24
Open Tender
Electrical Works
Item Rate
120 days
Anushaktinagar, Mumbai.
Please refer Tender documents
8 documents required · 8 mandatory
₹0
₹76,000
6 Feb 2024
14 Aug 2023
15 Sept 2023
14 Aug 2023
13 Sept 2023
22 Aug 2023
14 Aug 2023 - 21 Aug 2023
Amount
Section -I: LT Cables
Section -II: Readymade Distribution Board
Section -III: Point wiring
Section -IV: Poles & Luminaires
Section -V: Miscellanous Items
Description of Work / Item(s)
Amount
Supply, installation, testing & commissioning of 1.1 KVgrade aluminium/ Cu stranded circular/ sector shape core conductor with XLPE insulation, extruded PVC inner sheathed, G.I flat strip/wire armoured, extruded FRLS grade antirodent & anti termite PVC (ST-2)outer sheathed cable conforming to IS : 1554 Part I / IS 7098 Part-I with latest amendments, fixed on wall/column/slab/ false ceiling / existing cable tray /existing hume pipe/trench/shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles and saddles or in ground , sand bedding,laying of baked bricks on side & top-, temporary reinstatement, back filling, dewatering, consolidation,disposal of excess earth within the radius of 500 m and making good to the original finish etc providing Al cable tag as per enclosed detailed specifications, drawings & asper instructions of the E-I-C & of the following sizes. NOTE: 1) Excavation of earth shall be measured under Excavation item no-10 of Miscellaneous section.. 2) Sealing of hume pipes with wooden bushes after cable laying shall be included in the scope of work.. 3) Clamping of cables on trays including supply of clamping materials as per instruction of EIC shall be included in the scope of work. 4) HDPE pipe shall be measured seperately under item of Miscellaneous section.
3.5C x 50 Sq.mm Al. conductor cable
4C x 10 Sq.mm Al. conductor cable
3C x 2.5 Sq.mm Cu. conductor unarmoured cable
LT Cables End Joints : End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket,double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings,specifications and as per the instructions of the Engineer-in-charge.
3.5C x 50 Sq.mm Al. conductor cable
4C x 10 Sq.mm Al. conductor cable
3C x 2.5 Sq.mm Cu. conductor unarmoured cable
Description of Work / Item(s)
Amount
Supply, installation, testing & commissioning of following readymade distribution boards, double door, IP 42 degree protection complete with necessary, MCB isolators , MCBs,earth leakage circuit breaker (ELCB) etc including interconnections with appropriate capacity size of PVC insulated copper conductor wires (ISI marked),suitable for concealed mounting /wall mounting with MS frame workof 40 x 40 x 5 mm MS angle iron, with M.S. enclosure fabricated out of min 18 SWG /20 SWG thick M.S. CRCA sheet as per manufacturers standard, with concealed hinged door, locking arrangement etc. including earthing clamps for both incoming & outgoing circuits,interconnections, per phase isolation kit as required,cable end box & wire way box if required, continuous copper earth wire in the wire way box with single/duplicate brass earthing terminals, danger board, name plate, flexible earthing for the door, metal treatment & powder coatedpainting, Phase Distribution drawing etc. all as per drawings (G.A. & fabrication drawing to be got approved). Note: 1. MCBs (Type –C) shall be minimum 10 KA breaking capacity, as specified. 2. Blanking Plates shall be included in scope of work. 3. DB shall be of standard readymade type from approved manufacturers as indicated in preferred makes of material.
VTPN MDB : a) 100 A , FP MCCB - 1 No. b) 63/40 A ,TP MCB -4 Nos. c) 12 way brass neutral link - 2 set
ETPN DB : a) 40A FP MCB - 1 No. b) 40A DP ELCB with 30mA sensitivity - 3 nos. c) 6-32A SP MCB - 24 nos. d) 8 way brass neutral link - 4 set
Description of Work / Item(s)
Amount
Point wiring in PVC (HMS variety) conduits : Point wiring for light/ceiing fan/6A/ 16A/ socket outlet/6A outlet for exhaust fan , bell point etc. with 1.1 KV grade FRLS PVC insulated multistranded copper conductor wire (ISI marked), in existing floor raceway/ 25 to 40 mm dia High mechanical stress (HMS) rigid PVC conduit having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm.thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 0.9mm G.I. Saddles, ready made MS switch boxes & socket outlet boxes of nominal 1.2 mm thickness , brass earthing stud 1/2 nos, controlling modular switches, sockets with moulded front plate and inner plate etc. including appropriate size of FRLS PVC insulated copper earth wire ,brass/bakelite (straight / angular) lamp holders, 3 plate ceiling rose,6 A, connectors, painting etc. as per specifications and drawings and as per instructions of E-I-C and as detailed below : (sample switch Box etc. to be got approved before fabrication). NOTE: 1. Connections shall be done with crimped type tinned copper lugs & washers. 2. All switches & socket outlets shall be as per preferred makes. 3. All sample boxes with accessories /luminaires shall begot approved from Department. 4. All 16 A socket outlets should be with 6 pin type. 5. MS boxes other than switch boxes & socket outlet boxes shall be fabricated out of minimum 1.5mm thick MS sheet duly painted with red oxide primer & 2 coats of epoxy paint. 6. Minimum size of the FRLS insulated copper earth continuity wire shall be 2.5 sq.mm. 7. The colour shade of switches shall be white /off white. For socket outlet points/switch boards on normal power supply, the cover plate shall be white/off white colour, graphite grey (RAL 7024) or other shade as per instruction of EIC, for socket outlet points/switch boards on DG power supply. 8. The scope also includes supply of modular blanking plates where ever required. 9. The maximum permissible number of FRLS insulated wires through PVC/MS conduits shall be as per technical specifications. 10. The point wiring shall generally be concealed type only, except in lift shaft/ Elect. Shaft/ Basement areas/ in RCC retaining wall/ in dry well/ above false ceiling & wherever concealed wiring is not feasible, as per instructions of E.I.C
Primary Light point with 2 nos. 1.5 sq.mm wires & 1 No. 2.5 sqmm earth wire with 6A switch
Secondary light point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looped to above item 1.1
6 A + 16 A (6 pin) socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire & loopingwith 1.5 sqmm + 2.5 sqmm wires complete withindependent 6A and 16 A SP switches in one box.
6A socket point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires & 6A switch on switchboard.
Description of Work / Item(s)
Amount
POST TOP WITH LAMP : Supply, Installation, testing & commissioning of 3000mm single arm decorative lamp post. Pole should have an Aluminium extruded Grooved pipe of 80mm OD with an inner GI pipe of 60.3mm OD for strengthening the pole. The shaft shall have a top bracket arm of 48mm OD with Casting embellishments to mount a 50W LED with 3000CCT , IP 65 hanging luminaire with a linear PC diffuser. The post top lamp shall be of M/s Suncity innovation LLP or equivalent approved including internal wiring with 3Core 2.5 sq.mm FRLS PVC insulated copper conductor cable from terminal box at bottom of the pole to the luminaire, earthing of luminaire waterproof 2/3-way straight / T shape IP connector etc as per instructions of the EIC. Note: 1) Independent wiring to be done for each fixture from terminal box. 2) No negative tolerance is allowed on the min. system performance parameters indicated in SOQ & specifications. 3) Photograph of Post TOP LAMP is attached for Reference. 4) Civil foundation items shall be measured separately against relevent item nos. of Section-V.
SOLAR POST TOP LANTERN : Supply, Installation, testing & commissioning of post top luminaire mounted on 4m (above ground) Al alloy pole with UV resistant powder coating and with solar PV panels mounted on all four vertical sides of pole (2m from top) & integrated Li-ion battery with MPPT solar charge controller mounted inside the pole. The luminaire shall have min. 2500 lumen output, IP66 with 4000K CCT. The scope of item shall include the cost of RCC foundation , foundation bolts, anchor plates, nuts, washers etc as per enclosed detailed specifications & drawings, as required to complete the work in all respect as per instructions of the E-I-C. Note: The RCC foundation including excavation in all types of soil/foot path cutting , temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 500 m and making good to the original finish shall be measured against item no 10 & 12 of Section-V.
Supply, installation, testing & commissioning of 800-1000 mm high with aluminium pipe decorative bollard Light. The bollard light shall have 15W LED bulb min.IP 65, 2700-4000 degree K CCT fitted on the top with linear PC diffuser similar to M/s Suncity Innovation (Photo attached ) or equivalent approved with PCC block for mounting on ground, anchor fastners, 2 nos 40/33 mm HDPE pipes in PCC block for passage of loop in & out cables etc. with waterproof 2/3-way straight or T shape IP connector inside the structure etc The scope also includes wiring with 3C x 2.5 sqmm Cu PVC unarmoured cable in GI pipe from existing terminal box of street light pole wall upto terminal of fixture, earthing etc. complete as required as per instructions of E-I-C. The PCC 1:3:6 foundation shall be measured separatetly against item no 11 of Section-V.
Step Light: Supply, installation, testing & commissioning of 5W, LED Step Light fixed in wall with necessary accesories , waterproof 2/3-way straight or T shape IP connector fixed inside the structure, etc.all as required and as per the instruction of EIC. Note: Scope of work also includes concealement of step light by chiseling / cutting in wall/ column/slab, filling the leftover gaps , after placing the light, with cement, mortar, finishing by applying white cement etc. as per site conditions & as instructed by EIC.
Supply & erection of 6 to 10W LED bush light IP 65, IK 05 CCT2700 to 4000K mounted with adjustable bracket on PCC block of 200 x 200 x 200 mm for mounting on ground, anchor fastners, 2 nos 40/33 mm HDPE pipes in PCC block for passage of loop in & out cables etc.
Spike light :
Supply,installation,testing and commissioning of 7 Watt, LED spike lighting fixture outdoor LED spyke light fittings with all accessories with waterproof 2/3-way straight or T shape IP connector etc. all as required and as per the instruction of EIC. Note : Scope also include foundation bolt & nut for fixing bollard light fitting all as per instruction of EIC. The PCC 1:3:6 foundation shall be measured separatetly against item no 11.
Supply,installation,testing and commissioning of 7 Watt, RGB colour LED spike lighting fixture make outdoor LED spyke light fittings with all accessories with waterproof 2/3-way straight or T shape IP connector etc. all as required and as per the instruction of EIC. Note : Scope also include foundation bolt & nut for fixing bollard light fitting all as per instruction of EIC. The PCC 1:3:6 foundation shall be measured separatetly against item no 11.
Linear neon flex LED strip lighting:
Supply, installation, testing & commissioning of 24V,50Watts/5 Mtr Neon LED flex tube of M/s. Star light / M/s.Lighting technology make having IP 67 protection complete on surface / recess with required clamp and hardware all as required & instructed by E-I-C.
Supply, installation, testing & commissioning of dimmable 24V constant voltage LED power supply 80W driver of M/s.OSRAM make with all accessories, all as required and instructed by EIC..
Supply installation, testing and commissioning of 0-10 range,60-400W rotary LED light driver dimmer switch for neon LED flex tube control with all accessories, all as required and instructed by EIC.
Supply, installation, testing & commissioningof 54W, RGB colour LED flood light with driver complete with all necessory accessories etc as required as per instructions of E-I-C.
Supply, installation, testing & commissioning of 3-9W, aluminium die cast, graphite grey colour, outdoor wall light similar to model no.GOWL-4009A of M/s.Star light make for arch with necessory accessories.
Surface mounted LED luminaire 3000 lumen output, IP 66 IK08 ,4000-5700K CCT similar to M/S Lighting technology make cat no Parker V2 surface or eq. approved
Earthing of light poles etc. with 8 SWG G.I earth wires 8 m long coiled in 1m dia at a depth of 1400mm below ground level complete with soldering and connections with sockets etc all asas per instruction of E.I.C
Supply, Installation, testing & Commissioning of 8 SWG GI earth wire complete with soldering and connections with sockets etc all as as per instruction of E.I.C
Description of Work / Item(s)
Amount
Terminal Boxes: Supply & erection of min. IP 65, Polycarbonate/FRP terminal box of 300 x 200 x 125 mm size, housing 4 Nos terminals (for 10 sqmm Al cable) on epoxy insulator,3 nos. 3-6A SP MCB with 6A RCCB, 1 no. brass neutral link & 1 no. brass earth link etc. including internal interconnection from terminals to SP MCB, suitable for mounting on external wall etc. for distributing power to landscape luminaires as per instructions of E.I.C.
Junction Box: Supply and installation of IP66 Halogen free and weather proof cable junction box (without knockouts ) similar to catalogue no. KF5000C of M/s HENSEL make with 6-32 A SP MCB -9nos mounted in the box with DIN channel & stopper 3way MCB short link-3nos,32A,8way neutral link-1no, 8way earth link-1nos etc. 2mm thick gland plate of suitable size, and open-able plain cover etc.
Supply & installation of 250 mm dia heavy duty RCC Hume pipe of class 'NP3' to be laid in ground/from concrete cable trench to ground, for passing of cables with necessary joints, concrete supports. Scope includes escavation below ground level in all types of soil/concrete road cutting/foot path cutting, nallah cutting /any RCC wall/floor cutting including cutting, back filling, dewatering, consolidation, reinstatement of excess earth within the radius of 500 m and original,disposal making good to the original finish etc. spare space of hume pipes after cable laying and spares hume pipes shall be sealed properly with fireproof materials.
Supply & laying of 50/42 mm OD/ID self lubricated HDPE pipes in ground at depth of 500 mm including cutting of existing footpath,road etc, sand bedding,laying of warning tape on top,temporary reinstatement. backfilling ,dewatering if necessary consolidation,disposal of excess earth with in the radius of 500 m etc. all as per the attached work specification and instructions of EIC. Note:. 1) The scope of work includes HDPE pipe accessories suchas couplers, cable end plugs, cable sealing plugs etc. 2) Excavation shall be measured separately under relevant item of Excavations.
Supply & laying of 50/42 mm OD/ID self lubricated HDPE pipes fixed onwall/column/slab with 5mm thick M.S. flat /GIspacer/angle/ support fixed with coach screws/ grouted inwall/anchor fasteners 2mm thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.Sspacers/angles all as per the attached work specification and instructions of EIC. Note: 1) The scope of work includes HDPE pipe accessories suchas couplers, cable end plugs, cable sealing plugs etc.
M. S. Boxes : Fabrication, supply and installation of M.S. boxes with 2 coats of primer & 2 coats of enamel / PU paint as per instructions of EIC.
Concealed HMS PVC conduit: Supply, installation, testing and commissioning of 25mm dia. FRLS HMS PVC conduit in wall/ column/slab/beam/ground, complete with necessary accessories like coupler, elbow, tee, bends, circular boxes etc. Note: Scope of work also includes chiseling & cutting in wall/ column/slab/ground, filling the leftover gaps with cement, mortar , finishing by applying white cement & necessary touch up painting etc. as per site conditions & as instructed by EIC.
Surface HMS PVC conduit: Supply, installation, testing and commissioning of 25mm dia. FRLS HMS PVC conduit fixed on the surface of wall / slab / column / beam with 2 mm thick hot dip GI saddle & 4-5 mm thick hot dip GI Spacer (3 nos. per meter) complete with necessary accessories like coupler, elbow, tee, bends, circular boxes etc. all as per specification & as instructed by EIC.
PVC coated flexible steel Conduit: Supply, installation, testing & commissioning of 32mm liquid tight, FRLS , PVC coated Flexible Galvanised Steel conduit made up of helical coil of self interlocked ribbed stripes of Galvanised steel complete with necessary accessories like coupler, elbow, tee, bends, circular boxes etc. fixed on the surface of wall / slab / column / beam with 2mm thick hot dip GI saddle & 4-5 mm thick hot dip GI Spacer as per specification & as instructed by EIC.
Excavation
Excavation in soft soil/murum including shorting or dewatering, removing of bricks/tiles etc.,disposing the excess earth within the radius of 3000 m, refilling, consolidation of surface etc. as required & as directed by Engineer-in- charge.
Cutting of asphalt road / concrete flooring /drain by using hydraulic drilling machine upto 200mm depth as required and stacking of rocks, refilling, consolidation of surface & Disposing the excess earth within the radius of 3000 m as required & as directed by Engineer-in- charge.
Removal of pevar block / shahbaz stone / existing drain wells & refixing as per original as required & as directed by Engineer-in-charge.
Providing plain cement concrete 1:3:6 using graded stone aggregate of including consolidation, frame work & shuttering as required ,finishing, curring etc. as per specification & as directed by EIC.
Reinforced Cement Concrete of grade M-30 in foundation, plinth & superstructure for all type of Structural/ RCC elements conforming to IS 456-2000 , IS 3370 (latest) and IS 13290-2002using 20mm. maximum size down graded stone aggregate including machine mixing, conveying,placing in position, mechanical consolidation,finishing, curing etc. complete as per specifications and drawings for the following etc. complete as directed by Engineer -in-Charge. Notes for reinforced cement concrete:- a)Cement for structural works shall be OPC/PPC ISI marked and duly approved bythe Engineer-in-charge. b) PPC/blended cement of ISI marked shall only be used for finishing works on priorapproval of Engineer-in-charge. c) All RCC work shall be controlled concrete unless otherwise specified and shall be carried out strictly in accordance with the drawings and specifications. d)The rates for RCC works shall be exclusive of cost of reinforcement and form work unless otherwise mentioned. e) All coarse aggregate to be of 20mm.maximum size & uniformly graded unless otherwise mentioned. f)Test for Concrete shall be done as per IS 456-2000 and the cost of the same shall be borne by the contractor.
Reinforcement for RCC work including supplying steel bars of various diameters as required at site of work including loading, unloading, transporting, decoiling,straightening, cutting,bending placing in position and binding with 18 gauge, soft drawn annealed steel binding wire including carrying out various tests as required etc. all as per specifications, drawings & as directed by the Engineer in charge. Note:- Cost of binding wire shall be borne by the contractor & shall not be measured for payment.
Thermo Mechanically Treated bars of grade Fe-500 D manufactured by SAIL , TATA STEEL, JSW and RINL only.
Providing random rubble masonry with rough dressed hard stone below plinth in foundation, plinth, retaining wall, tree guards, sitting etc. in cement mortar 1:6 including through stone, header stone, bondstone, quoins etc. well packed including filling the interstices with smaller stone chips, striking,raking out joints & finishing the joints, including scaffolding, curing etc. all complete as per specifications, drawings and as directed by the Engineer in Charge.
Cement pointing to random rubble masonry wall with cement mortar1:3 including raking out joints, pointing neatly and finishing the joints , curing scaffolding etc. complete all as per specification, drawing and as directed bythe Engineer in charge.
Raised and cut pointing
Sunken or recessed Pointing
Earth Station: Providing earth station with heavy dipped GI earth plates electrode 600 x 600 x 6.0 mm in size at the depth minimum of 2.5 m below ground level (bottom of Plate) confirming to IS 3043 complete with all required materials like coke / charcoal, salt, G.I nut bolts, washers, 19 mm dia GI pipe (B class), 150 mm thick concrete wall chamber duly plastered having size of 500 x 500 x 500 mm, heavy duty (minimum 6 mm thick) M.S chequred plate cover, associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements, complete with funnels, GI test links (50 x 6 mm), two runs of 25 x 6mm G.I strips for connecting G.I plate & test link etc. including excavation of ground in all types of soils, refilling & removal of excess earth within a radius of 3000 m etc. all as required as per the drawings, specifications & instructed by Engineer-in-charge. Note:- 1. The chamber cover & frame shall be got approved by Department & painted with two coats of red oxide & one coat of enamel paint. 2. Painting of earth value & test date on cover plate. 4. Earthing strips shall be welded with the earthing plate before galvanizing & two holes on each strip & plate shall be made for fixing the screws.
Earthing strips: Supply, installation, testing & commissioning of following sizes of heavy dipped GI strip fixed to wall / slab / column / beam with 2mm thick GI saddle & 4-5 mm thick GI Spacer or in ground at a depth of 750 mm below ground level including excavation in all type of soil , refilling and removal of excess earth within a radius of 3000 mtrs., temporary reinstatement and back filling of trench, interconnection of earth strips / wires with GI nut bolts & washers, painting with two coats of black bituminous compound for earth strip in ground and green colour enamel painting for strip on surface etc. all as required & instructed by the Engineer-in-charge.
In ground (25 x 6mm)
On wall / slab / column / beam (25 x 6mm)
Cable Marker : Supply, installation of oval/circular shaped G.I cable marker engraved as "LT/HT Cable/HT straight through joint" complete with 32mm dia NB medium G.I pipe support as per IS 1239 with G.I nut bolts etc all as per drawing,specifications and as per the instructions of E.I.C. Note: PCC base concreting and excavation shall be emasured separetly under relevent items.
Supply and erection of FRP art piece with lights and Translucent yellow colour globe with ochre yellow lights etc including all fixing accessories as per drawing no DCSE/ARCH/SM-Reno/10 & as per instruction of EIC. Note: Necessary civil work required shall be measured separately under relevant item nos.
Power feeder /contactor box: Supply, installation ,testing & commissioning of readymade Cable Junction Boxes IP 66 of size 600 x 300 x 170 similar to catalogue no.K0401 of M/s Hensel with following equipments : i. 63A,4P,RCBO- 1No. ii.4P,63A, power contractor & 0.5A,D-curve ,SP,MCB for protection of contactor coil - 1set iii.20A, DP, two-way with centre off changeover switch similar to model no.412430 of M/s Legrand-1 no. iv. Single channel Timer (similar to AlphaRex3 D21 Astro having model No. 4126 54 M/s Legrand)-1 no. v. 6-32A SP MCB - 6 Nos. vi. MCB shorting link 4ways -1 nos. vii. Nuetral link 4ways -1nos viii. Earth link 8 ways -1 nos Note : a) Interconnection of power circuit shall be done with 6sq.mm FRLS flexible copper wires & heavy duty reducer type copper lugs etc. b) Danger board shall be provided.
EVERCREST PROJECTS PVT LTD.
JAMES ELECTRICALS PRIVATE LIMITED
TRANS ENTERPRISES PVT. LTD.
EVERCREST PROJECTS PVT LTD.
TRANS ENTERPRISES PVT. LTD.
JAMES ELECTRICALS PRIVATE LIMITED
SAMARTH ELECTRIC
TRANS ENTERPRISES PVT. LTD.
JAMES ELECTRICALS PRIVATE LIMITED
EVERCREST PROJECTS PVT LTD.
TRANS ENTERPRISES PVT. LTD.
JAMES ELECTRICALS PRIVATE LIMITED
SAMARTH ELECTRIC
EVERCREST PROJECTS PVT LTD.
TRANS ENTERPRISES PVT. LTD.
EVERCREST PROJECTS PVT LTD.
SAMARTH ELECTRIC
JAMES ELECTRICALS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .