| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC | L1 | Accepted-AOC Quoted lowest bid | |
| 2 | Not Admitted-Finance 0 BHOLA BABU H B ROAD BHARALUMUKH MACHKOWA GUWAHATI KAMRUP ASSAM 781009 | KAMRUP METRO | ASSAM | 781009 | - | Not Admitted-Finance Not qualified for AOC | |
| 3 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹5.1 L
EMD Value
₹10,285
Closing Date
29 Apr 2022, 2:30 pmClosed
CEO HDA
Office of the Chief Executive Officer Haldia Development Authority City Centre P.O. Debhog Haldia 721657 Dist Purba Medinipur
Supply Installation Testing and Commissioning of 12 Mtr. Mini Mast (2 Nos.) with LED Flood Lights LED Street Lights etc for area illumination at the proposed place of shifting of Nandakumar Police Station at Mohammadpur (near fatepur bridge) under Na
2022_HDA_376695_1
01/HDA/EC-ELECT/2022 2023
Open Tender
ELECTRICAL WORKS M/R
Item Rate
90 days
Haldia
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,285
Haldia
3 Jun 2022
18 Apr 2022
2 May 2022
19 Apr 2022
29 Apr 2022
22 Apr 2022
21 Apr 2022
Items
Supply & delivery of 60 Watt LED street light with pressure die cast aluminium housing, IP66 protection, road way luminarie with high power LED as per the technical specifications. Make & Model No.: 1) Bajaj (model no.:ENXTP60LWH CRPCSD)/ 2) Philips (model no.:BRP062 LED 65 CW SLC S1 PSU)/ 3) Crompton (model no.: LSTS-60-CDL-M)/ 4) Havells (model no.: ENDURA CITYLITE PLATPLUS SL 60W LED 757SASY BO PC).
Supply & delivery of 150W LED Flood light as per the technical specifications. a) 150 W for each set (Maximum). b) System Efficacy at Luminaries Level shall be minimum 120 Lumens/Watt. c) The fixture shall have Ingress Protection of IP 66 Rating for both for Optical & Electrical Compartments. d) Luminaries should consist of Universal Voltage Driver to handle wide operating voltage range from 130-270V AC and frequency range of 50+/-3% Hz. e) Driver shall have high efficiency and have inbuilt safety features like over voltage , short circuit , over load , thermal protection and reverse polarity protection. f) Luminaries should be powder coated and housed in a single piece Pressure die cast non-corrosive Aluminium alloy enclosure with optimal fins for Heat Sink Mechanism. g) Rated Operating Temperature should be 0 deg to +55 deg C with a relative humidity of 10-95% RH. h) Luminaries shall have five (5) years replacement warranty period from actual date of completion of work including driver/control gear, LED etc. (Make & Model No.: Bajaj-BJFL 150W LED White/ Havells-JETAVALOURFL 150W LED 757 PINTNALTG/ Crompton-LFLN-150-CDL/60-M/ Philips- BVP 192 LED 160 CW NB FG PSU GR).
Supply, delivery including transportation of 12 M Height Hot Dipped Galvanized (BS EN ISO: 1461 2009) coated, hot rolled Sheet of non-structural alloy 3.0 mm thick (BSEN 10025) Octagonal/polygonal Mini-mast (single section) with monkey climbing arrangement and 1 no Full Moon Bracket suitable to mount 6 nos. of non integral flood light fittings (with luminaries mounting plate and provision of passing wire) along with GI nut bolts, (IS 1367) in house Terminal arrangement with cover for cable loop-in and loop-out. The rate should include testing at your works, all taxes and delivery the materials at site. (Make: UTKARSH INDIA LTD/TRANSRAIL LIGHTING LIMITED/BAJAJ ELECTRICALS LTD).
Erection of the Mini Mast 12 Mtr. With modern engineering practice (Excluding the cost of RCC foundation)
Supply and fixing of SPMCB "B" Curve 1 Amp with ISI marked to be placed on a din channel of Pole and supply and fixing of Terminal connector at the suitable location of the pole.
Supply and delivery of 1.1 KV grade 4 C X 10 Sq mm XLPE insulated and PVC sheathed aluminum armored Cable. As per IS 7098 Part -1 with latest amendment if any. The cable should have ISI mark.
Supply and Installation of HDA printed logo suitable 15"×9" on GI Octagonal/tubular Pole.
Fixing only Flood light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
RCC Foundation for 12mtr high mast as per the enclosed drawing and details schedule.
Connecting the equipments to earth bus bar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (ii) No. 6 SWG
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (1.54sqm RCC foundation of the mini mast x 2).
Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint. (1.54sqm RCC foundation of the mini mast x 2) (b)Two coats.
Laying only Cable upto 50 sq.mm through existing RCC/Hume/ GI /HDPE Pipe/open masonry trench for single, 2, 3, 3½ & 4 core
Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. 50 mm dia
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: i) 4 core X 16 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. i) 4 core X 16 sqmm
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Earthing with 50 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts, For Soft Soil.
Excavation of soil for installation of Earth Electrode and filling & ramming. (1Cu mtr. X2 )
Extra for providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Providing and fixing typical citizen information board constructed with BFS, PCC, 250 mm & 125 mm brick wall (1:4) with necessary 15 mm thick plastering (1:4) & rule pointing, including supply & fixing of white marble stone (1100mm X 800mm X 18mm) with black colour engraved lettering as per the enclosed drawing.
Supply of HDPE pipe conforming to IS-4984-1985 (Dia) [PE-63], 6Kg/Sq.cm(Working Pressure), 50mm Dia
Supply & delivery of GI earth Spike (1830 X 20 mm)(Each Pole).
Earthing complete with driving of Earth Spike & connection of earth electrode with non current carring metallic parts of supports, stay.
Labour for fitting and fixing high density poly-ethylene pipes or P.V.C pipes for below ground work including cost of jointing materials paints etc fitting and fixing all necessary specials,cutting pipes,making threads,cutting holes in walls or R.C.floor where necessary and mending good all damages excluding the coast of masonary or concrete work,if necessary,but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the site engineer-in-charge.(Payment will be made on centre line measurement of the total pipeline including specials)(for 50mm dia).
Supplying and fixing 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection, 32Amp.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 4 way Enclosure
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Laying on Wall / surface with Saddles / clamps. Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .