Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹94.5 LAccepted-AOC 12 2 332 21 HILL COLONY OPP SUNRISE SCHOOL MEHDIPATNAM HYDERABAD 500028 | HYDERABAD | HYDERABAD | TELANGANA | 500028 | 1 | Accepted-AOC Being L1 | |
| 2 | 2₹1.1 Cr+₹13.3 L (14.1%)Rejected-AOC 4 195 38 PARAMESHWARA NILAYA MARAKADA KUNJATHBAIL DAKSHINA KANNADA KARNATAKA 575014 UDYAM KR 11 0021217 | DAKSHINA KANNADA | KARNATAKA | 575014 | 2 | Rejected-AOC Being not L1 | |
| 3 | 3₹1.1 Cr+₹13.5 L (14.3%)Rejected-AOC | 3 | Rejected-AOC Being not L1 |
Tender Value
₹96 L
EMD Value
₹1.7 L
Closing Date
5 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE R N D Secunderabad
CE R N D Opp JBS picket Secunderabad
PROVISION OF NEW INFRASTRUCTURE AND ALLIED FACILITIES AT DMRL HYDERABAD
2021_MES_470478_1
CERD/SEC/TOKEN/22 OF 2020-2021
Open Tender
Civil Works
Lump-sum
365 days
Kanchanbagh Hyderabadf
Class C
category a i
6 documents required · 6 mandatory
₹1,000
GE I R N D Kanchanbagh Hyderabad
₹1.7 L
Yes
28 Oct 2021
25 Aug 2021
11 Oct 2021
25 Aug 2021
5 Oct 2021
22 Sept 2021
60 days
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01 to 1.03) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of Workshop building with annexe, RCC framed structure building, steel trusses and galvalume roofing etc complete all as shown on drawings and as specified. etc complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor forConstruction of RCC Septic tank 100 users complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Soak well of size 2.4m dia and 4.5 M effecive depth complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for "EXCAVATION, EARTHWORK AND SITE CLEARANCE” as listed in Schedule ‘A’ Part - II representing _______ % ________________ percent Above / Below the lumpsum price of `3,84,310.61 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “ ROADS, CULVERTS AND PATHS ” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `5,41,015.25 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `1,60,365.88 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for " AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `2,51,036.76 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for " INTERNAL ELECTRIFICATIONS ” as listed in Schedule ‘A’ Part - VI representing _______ % __________________ percent Above / Below the lump sum price of `1,68,594.21 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “ EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `6,68,373.33 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of `52,981.24 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION ” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of ` 69,757.60 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “ AIR CONDITIONING ” as listed in Schedule ‘A’ Part - X representing ______ % _________________ percent Above / Below the lump sum price of ` 7,720.60 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “ INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - XI representing ______ % _________________ percent Above / Below the lump sum price of ` 6,481.81 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “ MACHINE FOUNDATION ” as listed in Schedule ‘A’ Part - XII representing ______ % _________________ percent Above / Below the lump sum price of ` 88,217.65 inserted by the MES in Schedule ‘A’ Part - XII
Schedule 'A' Part - XIII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 14.00 to 40.00
INTERNAL ELECTRIFICATION Exhaust fans heavy duty, AC single phase 230 / 240 V of size 300 mm sweep,50Hz,900 RPM metal body with louver Including fixing arrangement with MS bracket frame complete all as specified and directed. Make: Havells / Bajaj / CG.
Ceiling fan complete with electronic type regulator and accessories 240 V, 1200 mm sweep, BEE,BLDC type with down rod, canopy connecting up with 3 core 1.0 Sq.mm cable of required length at site from ceiling rose complete all as specified and directed. Make: Havells/ Orient/CG
Supply ,fixing and testing, LED fitting batten type , 20 watt, 4feet , AC universal batten for T8 lamp 230V Energy efficient, with Drive including tube rod, mounting accessories, connecter block, etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting,complete all as specified and directed. Make: Havells cat Part No: REGALBATTENT8UPTO1X22WSSBSWH and CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent in Philips/Wipro/CG
Supply,fixing and testing, LED batten type , 10 watt, 4feet , AC universal batten 230V Energy efficient, with Drive including tube rod, mounting accessories, connecter block, etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting, complete all as specified and directed . Make ; Havells Cat Part No: LUMILINEPLUSBS10WLED865SPCSS or Equivalent in Phillips /Wipro
Supply,fixing and testing, LED Street light fitting with IP65 type protection, 35W, 230 Volts, 50 Hz and made of pressure dia cast aluminium housing with high power LED as lighting sources and embedded cover with driver , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounting including light grade GI pipe 40mm dia bracket bent to shape not less than 1.5mtrs length with two sets of lfat iron clamps, bolts, nuts, washers etc., painting and provision of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as specified and directed. Make:Havells cat part No. DURACITYLITEPLATPLUSSL35WLED757 SASYBOPC or Equivalent in Phillips /Bajaj
Supply and fixing LED luminaire 2x2, 34 watt, 220 V AC surface type with high efficiency diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make:Havells cat part No.PLUTOSURFACE2X2PLS34WLED857S or Equivalent in Phillips /Bajaj
Supply,fixing and testing, LED high bay 150 W,230V IP 65 LED highbay for ceiling (surface/suspended ) solution with PDC housing toughened & shattered proof glass wide beam optic complete with all internally prewired and including connecting up the twin core hoisted flexible copper conductor cable with suitable size complete all as specified and directed . Make;Havells :RADIOSOHB150WLED75790DBOPC or Equivalent in Phillips /Bajaj
MCB TPN 40 Amps, working on 415V, complete all as specifeid and directed.
MCB SPN 40 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity, complete all as specifeid and directed.
MCB SP 5 to 32 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity, complete all as specifeid and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire 4mm, GI earth wire shall be protected by 15mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately
GI earth wire 4 mm dia fixed on walls / floor as earth continuity conductor fixed on wall / roof on epoxy insulators etc complete all as specified and directed.
Air Circulators with blades and all accessories, 230 volts single phase oscillating 600mm sweep suitable for wall mounting ,oscillation up to 90 degrees and metal body powder coated complete with all fixing accessories on wall, including provision of 3-way procelain connector, copper bunched flexible three core 1.5sq.mm PVC insulated cable from connection point to fan, complete all as specified and directed
Fabrication, Supply & Fixing of remote control motor for roller shutter with automatic level stopping switch button, single phase and also provision of power chain crank in absence of power with lifting capacity of motor for 1 M ton with electric connection complete,complete all as specified and directed Note: Design calculation and equipment details shall be got approved from GE before placing the order.
EXTERNAL ELECTRIC SUPPLY Cable trays GI hot dip perforated type of size 200mm width, 50mm height, 18 SWG, including coupler plates complete all as specified and directed
Cutting existing road / PCC of size 45cm x 60cm for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:4:8 type D2 using 40mm graded stone aggregates, complete all as specified and directed.
Supply, installation, testing and commissioning of transformer, outdoor type step down 11/0.433 KV, HT with 3 phase and LT with 3 Phase, 4 - wire system double copper wound with off circuit tap changer arrangement on HT side for a variation of secondary voltage with tapping range + 5% to -10% in steps of 2.5 % continous rating of 315 KVA (Level-II) confirming to IS: 1180 (Part 1):2014 Oil - IS: 335: 1993 including first fill of oil,making incoming and outgoing connection to Transformer with copper conductor with lugs & glands complete, all as specified and directed. Make :- ABB / SCHNEIDER / PROLEC GE / CROMTON GREAVES/ VOLTAMPThe rate quoted shall deemed to include the following :-
Temp. Rise in oil [Degree C.] : 40, By Resistance [Degree C.] : 45, Ambient temperature : 50, Winding Material : Copper Type of Cooling : ONAN, Class of Insulation : Class “A”, Vector Group : Dyn11, Frequency [Hz.] : 50, Phase : 3, Insulation Level [kV/Kvp] H.V. : 28/75,L.V. : 3/---, Primary Connection [HV] : Delta, Primary Volts : 11000V,Primary Phases : 3 Primary Wires : 3,Primary rated current : 16.53 A, Secondary connection [LV] : Star,Secondary Volts : 433V,Secondary Phases: 3, Secondary Wires : 4, Secondary rated current : 420.01A, Taps on Primary Winding for : +5% to –10% in steps of 2.5%, Primary Voltage Variation Off Circuit Tap Changer No. of switch positions : 7 Terminal Arrangement H.V. : Bare Bushings, L.V : Cable Box Load Losses (Level-II) At 50% Loading : 1025 Watts (Max.) At 100% Loading : 3100 Watts(Max.) Impedance (Z) [Percentage] HV - LV : 4.50% No Load Current (% of Rated Current) : Less than 1.5 %
SUBJECT TO IS: 1180 TOLERANCE a) Core & Windings with clamps b) Tank & Fittings c) Oil : as per IS HV - LV Orientation : 180 deg. Bushing - IS: 2099 & IS: 3347 Porcelain Bushings HV : 3 Epoxy Bushing LV : 4 Painting [Finish] : PU Light Grey Shade No. 631 – IS: 5
TESTS - Routine Tests as per IS: 1180 (Part 1):2014 (a) Ratio test (b) Polarity (c) Phase angle error measurement (d) I R Values (e) Winding resistance (f) Open circuit test (g) Short circuit & Impedance test (h) Separate source voltage test (j) Induced over voltage test (k) Pressure test (l) Oil leakage test
STANDARD FITTINGS AND ACCESSORIES: (a) Rating & Terminal Marking Plate One (b) Earthing Terminals Two (c) Lifting Lugs Two (d) Drain Valve with blanking plate One (e) Filter Valve with blanking plate One (f) Conservator One (g) Conservator Oil filling hole with cap One (h) Oil Level indicator with min. marking One (j) Dehydrating Breather One (k) Conservator Drain Plug One (l) Air Release Device One (m) Thermometer Pocket One (n) Pressure relief valve One (o) Roller Uni directional Four (p) Radiators (Weld able Type) Two (q) Bare Bushings HV Three (r) Cable Box LV One (s) Separate Neutral Terminal One (t) Off Circuit Tap Changer One (u) 100 mm dia Stem type thermometer One
Note :- (i) The Stud for neutral shall be sufficiently long to fix 2 Nos GI strip for earthing. (ii) Cost of Cable entry box on both sides ie. HV and LV shall be deemed to be included in quoted rates. (iii) Cost of foundation of transformer shall be deemed to be included in quoted rates.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25mm x 4mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately
GI earth strip 25x4 mm fixed on walls / floor as earth continuity conductor fixed on wall / roof on epoxy insulators etc complete all as specified and directed.
9. All CT shall be bar type CT ratio 500/5 primary Class 1,15VA 10. Auto Manual Switches and indication shall be provided, RYB incomer indication, ON/OFF/TRIP/TEST indication shall be provided. 11. Holder for lamp. 12. 1nos 230V, 15A 3pin Socket Shall be provided, 1nos Make Anchor / LEGRAND / Repurted Space heater 240V,50Hz supply. 230V 18W LED Lamp .Required Qty of 8", 230V,radial Cooling fan shall be provided. 13. Control Cable 1.5sqmm for control and 2.5sqmm for CT. 14. Control MCB. 15. Paint Shade of the panel shall be Light Gray 631 of IS : 5 min 80micron thk, Floor mounted cubicles shall be provided with a 75mm high channel base frame. The total height of thecubicle shall not exceed 2400 mm, CRCA sheet shall be 3.5mm thick, IP 65 outdoor type for load bearing and 1.6 mm thk for non load bearing, Incomer shall be at height ofmin 400mm. 2nos eathing connection shall be provided. Cable entry shall be bottom with gland plate of 3mmthk. . Gasket shall be of high quality neoprene. Busbar : Aluminium.
Steel tubular swaged poles type 410 SP 31 (Overall length 9.00 metre) complete with mild steel base plate, final taper plug, bolts, nuts and washers, screws, pole shall be painted with two coat of black bituminous paint throughout internally and externally upto planting depth and the remaining external complete pole portion shall be painted silver colour in two coats over a coat of red oxide primer painting, painting of black & yellow alternate strips of 30cm each externally from ground level upto 1.5m with synthetic enamel paint, complete all as specified and directed.
Supply and errection of wind driven turbo ventilator industrial type, having not less than 2000 CFM made out of stainless steel having blade thickness 5mm and dia meter 24-30 inches complete all as specified and directed
LED Street Light Fitting 35/36 W IP66, IP-66 including with pipe mounting arrangement for end mounting on 40 / 50mm dia pipe including provision of GI pipe bracket for 40 / 50mm dia, light grade, bent to shape as directed, 1.5m long with two sets of clamp, made out of flat iron 20x3mm, bolts, nuts and washers with two coats of aluminum paint over a coat of primer to steel surfaces, connecting electrically with PVC multistranded copper cable of suitable size and taking down existing street light fittings from poles, complete all as specified and directed. MAKE: Havells / BAJAJ / Crompton Greaves / Philips.
AIR CONDITIONING Supply and install air cooled split unit air conditioner indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with Minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with Minimum 5 star rating and EER 3.2.of capacity 2.0TR complete all as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA, complete all as directed
GOVARDHAN AND COMPANY
Rajesh Engineering Consultants
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .