Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.7 L+₹69,207 (6.28%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹12.4 L+₹1.4 L (13.0%)Rejected-Finance KILA ROAD 00 00 00 NARNAUL HARYANA 123001 | MAHENDRAGARH | HARYANA | 123001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹14.5 L+₹3.5 L (32.0%)Rejected-Finance 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance Other than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Prop of firm was partner in M/s poonia Const Co. banned |
Tender Value
Refer Docs
EMD Value
₹41,400
Closing Date
17 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura Cantt
SPL REPAIR / REPLACEMENT OF HT CABLES AND ALLIED WORK AT HISAR MIL STN UNDER GE HISAR
2020_MES_386253_1
CWE/MTR/HSR/48 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar
Class E cat b (ii)
7 documents required · 7 mandatory
₹500
GE Hisar
₹41,400
Yes
7 Jan 2021
17 Oct 2020
19 Nov 2020
17 Oct 2020
17 Nov 2020
5 Nov 2020
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan depth exc 1.5m but n.exc 3.00m and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick of soft/loose soil in trenches/pit complete all as specified and directed.
Removing excavated soil/material to a distance not.exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
M&L for sand cushioning and covering with clean and dry sand to underground electric cable in trenches 8cm thick before laying and 15cm after laying & stretching the cable. Punning shall be carried out by hand complete all as specified and directed. Note : Punned thickness shall be measured and paid separately.
Supplying and laying reinforced precast concrete cable cover class HV type 1 flat size 300mm x 180mm x 40mm (ISI Marked) complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (Using 20mm graded crushed stone aggregate) as in mass concrete including necessary form work complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of XLPE insulated screened PVC beded galvanised steel strip or wire armoured HT electric power cable (heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 95 Sqmm 3 core suitable for 11 KV earthed systems including taking out the old unserviceable cable complete all as specified and directed. Note :- Cable may be laid in trenches, under road, across the nallah, along poles / walls and in ducts etc. Excavation, earthwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid separtely.
Supply and jointing testing outdoor type cable end termination (heat shrink type) complying with jointing materials and accessories suitable for 11 KV (E) under ground XLPE, HT Cable of size 95 Sqmm, 3 core complete all as specified and directed.
S&F in replacement steel tube of light grade of size 100mm dia galvanised with all fittings fixed to walls / floors / poles or under road etc complete all as specified and directed. Note :- (i) The GI pipe shall be fixed with pole by MS clamps . (ii) The MS work shall be measured and paid separately.
S&F HT cable route / joint indicator made of 100mm dia cast iron top and 01 mtr long MS rod burried in ground upto 30cm and embeded in PCC (1:2:4) type B-1 block of size 15cm x 15cm x 30cm and painted with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Supply, errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 11 mtr long, 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete as specified and directed. Note : (i) The conductors / earth wires on existing pole to be shifted on new pole after errection of new pole. The rate for same shall be deemed to be included in above quoted rate. (ii) Earth work & PCC shall be measured and paid separately.
M&L for Cross Arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps, nuts, bolts , washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of primer complete all as specified and directed.
Supply installation, connecting and testing gang operated air break switch, mounted on HT insulators 11KV 200 Amps rating, triple pole, (nine insulator) suitable for horizontal / vertical mounting fixed and spring loaded revolving tinned brass / copper contacts, galvanized steel base frame, 32 mm bore medium grade pipe Galvanized operating rod (Medium Grade), operating handle, locking arrangement MS clamps, bolts, nuts & washers etc including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Note :- (i) Cross arms of 2 pole / 4 pole structure reqd for installation of GO switch, if reqd additional, shall be measured and paid seperately. (ii) Scope of work shall also include ACSR conductors PVC sleeves, PG clamps and thimbles reqd for jumpers / connections to OH lines of 2 poles / 4 poles structures and outgoings feeders.
fauji electric works
SAINI ELECTRIC STORE
VERMA BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .