| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹29.4 L+₹92,386 (3.25%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹31.5 L+₹3.1 L (10.8%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹33.7 L+₹5.2 L (18.4%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹40.7 L+₹12.2 L (43.0%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
8 Jun 2022, 6:00 pmClosed
GE NW BHANDUP
GE(NW) BAHDNUP, MUMBAI
ADDN/ ALTRN AND SPECIAL REPAIRS TO DRILL SHED(P-65) AND FLOORING OF CERTAIN SAILORS MD ACCN AT AT INS HAMLAUNDER GE(NW) BHANDUP
2022_MES_521031_2
8203/B
Open Tender
Civil Works
Item Rate
180 days
HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹82,000
Yes
24 Aug 2022
24 May 2022
9 Jun 2022
24 May 2022
8 Jun 2022
1 Jun 2022
Amount
Taking down cement plaster of any description in any position including racking out joints making key scrubbing down with water etc. and removal of debris out side MD land complete all as specified and directed.
M&L for 10mm thick ready mix plaster , on fair faces of brick work or concrete surfacesl; finished even and smooth including necessary scaffolding complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper with roller over one coat of alkali resistant primer.etc complete all as specified and directed .
M&L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of oil bound distemper over a coat of primersmooth finish.etc complete all as specified and directed .
M & L for 10 mm thick ready mix plaster using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified Note : Water proofing compound shall be measured & paid seperately.
M&L for preparation of NEW plastered walls surfaces & applying two coats of chemical waterproofing treatment (601 raincoat of pidilite or equivalent) on wall & chajja, terrace & parapet wall, such as Flexcoat, Beckcoat, Exshield etc or equivalent including filling of cracks in walls/concrete with " Crack-X" of pidilite or equivalent complete as per manufactures instructions, all as specified and directed.
M&L for complete removal of existing surfaces including washing / rubbing down with water of wall and applying two coats of chemical waterproofing treatment (601 raincoat of pidilite or equivalent) on wall & chajja, terrace & parapet wall, such as Flexcoat, Beckcoat, Exshield etc or equivalent including filling of cracks in walls/concrete with " Crack-X" of pidilite or equivalent including preperation of OLD surfaces complete as per manufactures instructions, all as specified and directed.
Supply only integral water proofing compound.
Demolition of brick work built in CM incl. taking out roots vegetation if any at any position and removal to out side MD land complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in CM(1:6) complete all as specified
Demolition of cement concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M &L PCC 1:3:6 type C2 75mm thick as in plinth protection finished even and smooth using extra cement compete all as specified.
M&L for 100 mm thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in floor, finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L bitumastic filling the joint of 10mm wide and 100mm depth comprising of one part of heated bitumen blown grade (85/25) any penetration and 2 part of sand by weight all as specified and directed.
M&L for endura paving tiles of technocommercial equivalent of size 300x300x10mm thick set and jointed in neat cement slurry and pointed with white cement to match the joint including 20 mm thick screed bed in cement mortar 1:4 over including finishing even and fair complete all as specified.
Dismantling stone slabs or pcc tiles of any description or thickness in steps, landing, flooring and similar work laid, bedded and pointed in cement mortar complete all as specified and directed.
Supply and fix granite slabs 20 mm thickGranite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over incl 20 mm thick screed bed in cement mortar 1:4 over including finishing even and fair complete all as specified.
Taking down chowkats of frames with shutters (without taking off shutters from frames) area not exceeding 1.50 Sqm each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damages to jambs , walls for taking out hold fast shall be finished identical to existing finish without any extra cost of Govt) all as specified and directed by Engr- in - charge
S&F In repair Anodised aluminium frame for partitions,doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F In repair Anodised aluminiumAnodised aluminium window and ventilator shutters, side hung typewithout sash bars, aluminium sectionsweighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F anodised aluminium grill DG- 102 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1mm thick of approved make all as specified and directed.
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
M & L for rounding to edges of stone slabs one edge, such as steps, cooking platform, and other similar situations complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete incl plastering (total thickness upto 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force )
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
Providing and fixing additional steel bar in various structural elements like column, beams and slab etc including drilling, bending and fixing the bars tying with preleft binding wires etc complete anchoring reinforcement bar in existing RCC member in holes of minimum 10d depth for 8 to 12mm dia bars complete all as specified and directed.
M&L for carrying out application of 'Bi-polar migratory corrosion inhibitor' EPCO-KP-100 on concrete surface. This inhibitor has migratory kind of propertyh which permits the material to migrate to a virtual extent of 100mm, through pores of concrete, inhibiting the corrosion and de-passivating the Electro-chemical reaction. It has property to attach anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete.
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB or Epoxy Zinc Primer by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of OR EPOXY BONDING AGENT OR equivalent of as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
Building up the profile of structual members by using polymer modified mortar upto 20mm thickness including levelling profilling etc complete all as specified and directed of approved Make Note :- Mode of measurement : Superficial area of concrete will be measured.
Building up the profile of structual members by using polymer modified mortar upto 40mm thickness including levelling profilling etc complete all as specified and directed.of approved makeNote :- Mode of measurement : Superficial area of concrete will be measured.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by engineer in charge.
M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by engineer in charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. etc and similar work confirming to Fe-290 Gde E-165. complete all as specified and directed by engineer in charge.
S&F rolled mild steel work in plates (plain or chequered) channels, square cut or notched (ordinary and countersunk) forming holes, without any attachment, Fe 410-W (Gde-E-250) quality-B, complete all as specified and directed.
M&L for Preparation of new steel surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Preparation of old steel surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L PCC 20mm thick type B0, 1 : 2 : 4 (12.5mm graded aggregate) in sub flooring complete all as specified and directed.
M&L non-skid coloured joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry over and including provision of bedding layer 15 mm thick in CM 1 : 4 complete all as specified and directed.
M&L non-skid coloured joint free ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, in vertical surfaces etc set and jointed in neat cement slurry over and including provision of bedding layer 10 mm thick in CM 1 : 3 complete all as specified and directed.
Taking down shutters of any description exc 1.00 Sqm and n. exc 2.00 sqm each and refixing in the same opening complete all as specified and directed.
Taking down shutter of any description exc 1.00 but n exct 2.00 sqm each Sqm each complete all as specified and directed.
M&L Flush shutters 30mm, solid core construction, with partical board core and ply wood face panels, commercial type on both sides complete all as specified and directed.
S&F 35mm II nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars) edge of framing plain, chamfered or rounded, fitted with cut and mitred bends for securing glass etc. size of members of shutters as specified in SSR, Part I, section -8, clause 8.24 (a)
S&F stainless steel butt hinges 100mm size complete all as specified and directed.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs,Meter Boxes etc all as specified and directed.
Taking down of existing ceiling fans, opening / dismantling of fan& fan blades, cleaning, servicing,oiling, greasing, carrying out repairs such as replacement of capacitors, bearings, bushes, canpoy, condensor, clamp, safety pin, rubber bush and reassembling the fan & fan blades,, connecting up, testing and re-fixing of the same ceiling fan of any sweep including provision of new cable from ceiling rose/ connector to fan and spray painting of ceiling fan with two coats of synthetic enamel paint after prepartion of surfaces,complete all as specified and directed
M & L for point wiring complete with proper colour coding using 1100 volts grade, 1.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also inclduifng 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one light point/fan point controlled by one one way switch, complete all as specified and directed
All as per item above but for one 5 pin socket 5 Amps on same board complete all as specified and directed
All as per item above but for one 5 pin socket outlet 05 Amp independent board complete all as specified and directed
M & L for point wiring complete with proper colour coding using 1100 volts grade, 2.5 Sqmm, PVC insulated, FRLS,unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked, drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good the same in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc. also inclduifng 2.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts mutli-stranded copper conductor green colour as continous earth wire connected to common earth dolly all as specified and diretced for one 5Pin,6/16Amps,Socket outlet independent,complete all as specified and directed
Supply & fixing ceiling rose , surface bakelite 3 terminal complete all as specified and directed.
Supply & fixing modular fan regulator,120W- 2 module complete all as specified and directed.
Supply & fixing switch modular type 6 Amp single pole one way 230V complete all as specified and directed.
Supply & fixing switch modular type 16 Amp single pole one way 230V complete all as specified and directed.
Supply & fixing socket modular type 6 Amp 2/3 pin single pole one way 230 V complete all as specified and directed.
Supply & fixing socket modular type 16 Amp 2/3 pin single pole one way 230 V complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 8 Module complete all as specified and directed.
Supply & fixing Modular white cover plate with frame 3 Module complete all as specified and directed.
Supply & fixing modular Metal Flush box 8 Module complete all as specified and directed.
Supply & fixing modular Metal Flush box 3 Module complete all as specified and directed.
Supply and fixing LED Low Bay Indoor Commercial White Light of 40 Watt capacity including with driver and prewired complete including 1.0/1.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and difected.
M&L for sub main wiring complete two run of size 1.5 sqmm PVC insulated ,unsheathed, heavy duty 1100 volts grade (FRLS) multi-stranded copper conductor cable ,drawn partly in and including PVC conduit concealed in walls etc including cutting chases and making good in CM 1:3 to match with the existing surfaces and partly drawn in and including PVC casing caping fixed on the surfaces of RCC slab/ceiling/columns/beams etc with all accessories, fittings, PVC junction boxes etc, also including one run of 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multi-stranded copper conductor green colour as continous earth wire connected to common earth dolly and mains, complete all as specified and directed.(For Building security Lights) Note: Three run 1.5 Sqmm PVC cable and one run of Casing Caping & conduit will be measured as "one unit"length.
Supply & fix sheet metal enclosure powder coated for MCB DB SPN 8 way Double door with din rail and 200A bus bar rating including making good to the disurbed surface matching with the existing complete alla s specified and directed.
Supply and fix MCB SPN 240 volts 40 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply and fix MCB SP 240 volts 6 to 32 Amps breaking capacity 10 KA 'C' Series rating complete all as specified and directed.
Supply & fixing street light of capacity 15 watt with IP 65 protection for external outdoor lightning Including 50 mm dia GI Bracket with 45 degree Bend with Nut bolts Fixing on Building Surface Wall complete all as specified and directed.
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 32X6 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 37900.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
industrial suppliers
R K TYAGIS
Parmatma Enterprises
C S Sharma and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .