COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
UPKEEP OF ELECTRICAL EXTERNAL SERVICES INCLUDING E M INSTALLATIONS AT NAD AND MO GOA AREA UNDER GE GOMANTAK
2023_MES_600204_1
85677/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOC
9 documents required · 9 mandatory
₹500
Yes
GE Gomantak
₹60,000
Yes
23 Aug 2023
1 Jun 2023
6 Jul 2023
1 Jun 2023
4 Jul 2023
15 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil for laying and taking down UG cable of any size complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 in depth getting out soft disintegrated rock for laying and taking down UG cable of any size complete all as specified and as directed.
Supplying & Laying in trenches Clear Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified and as directed. Note:-punned thickness of sand will be measured and paid.
Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm complete all as specified and as directed.
Supply and lay PCC cable cover class HV, type 1, flat size 300mm x 180mm x 40mm with ISI mark complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing complete all as specified and as directed.
Supply and Laying LT underground cable XLPE insulated armoured heavy duty 1100 volts grade of the following sizes complete all as specified and as directed. Note :- Excavation, PCC Cable cover and sand will be measured and paid seperately.
(a) 35 Sqmm 3.5 Core
(b) 50 Sqmm 3.5 Core
(c) 70 Sqmm 3.5 Core
(d) 95 Sqmm 3.5 Core
(e) 120 Sqmm 3.5 Core
(f) 185 Sqmm 3.5 Core
(g) 240 Sqmm 3.5 Core
Supply and laying HT XLPE cable insulated , screened, PVC bedded , galvanised steel strip armoured, electric power cable (Heavy duty) with aluminium conductor, cross sectional area 95 Sqmm 3 core 11KV grade, including dismantling of existing cable complete all as specified and as directed.
M&L GI tubing light grade use for the protection of cable complete all as specified and as directed.
(a) 40 mm dia
(b) 50 mm dia
(c) 80 mm dia
Supply and fix DWC high density polyethylene pipes having outer side wall corrugated and inner surface plain confirming to IS 14930 (Part-I & II) for protection of underground cable laid in trenches/floor/fixed on pole/wall including all fittings and clamps as required complete all as specified and directed. following sizes:-
(a) 50 mm dia
(b) 63 mm dia
(c) 90 mm dia
(d) 110 mm dia
Supply & Fixing sheet moulding compound junction box (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including MS clamp with nut and bolt, one in Nos MCB SP 0.5 Amps including cable glandes - 2 Nos, and two way connector 1 No, including dismantling old one complete all as specified and directed. Note :- MS clamp with nut and bolt will be measured and paid seperately.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including dismantling old burnt cable joint termination.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including dismantling old burnt cable joint termination.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm including dismantling old burnt cable joint termination.
M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 to 50 sqmm including dismantling old burnt cable joint termination.
M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm including dismantling old burnt cable joint termination.
M & L Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 240 sqmm including dismantling old burnt cable joint termination.
Supply & fixing MCCB 100 Amps, 3 phase, 3 pole, 415 Volts, 50 Hz, 16kA braking capacity including dismantling old one complete all as specified and as directed.
Supply & fixing MCCB 160 Amps, 3 phase, 3 pole, 415 Volts, 50 Hz, 36kA braking capacity including dismantling old one complete all as specified and as directed.
Supply & fixing MCCB 200 Amps, 3 phase, 4 pole, 415 Volts, 50 Hz, 25kA braking capacity including dismantling old one complete all as specified and as directed.
Supply & fixing MCCB 250 Amps, 3 phase, 4 pole, 415 Volts, 50 Hz, 25kA braking capacity including dismantling old one complete all as specified and as directed.
Supply & fixing MCCB 400 Amps, 3 phase, 4 pole, 415 Volts, 50 Hz, 25kA braking capacity including dismantling old one complete all as specified and as directed.
Supply & fixing MCCB 630 Amps, 3 phase, 4 pole, 415 Volts, 50 Hz, 25kA braking capacity including dismantling old one complete all as specified and as directed.
Disconnecting HT/LT cable and earthing connections of burnt/defective transformer of capacity 315 to 500 KVA , 11 KV/433 volts 3 phase from pole/floor mounted, taking from site of installation carefully with the help of Crane and transportation of the same to workshop for repairs, draining out the transformer oil, dismantling complete and taking out the core assembly and removing burnt out windings, dehydrating the core assembly, reassembling transformer after repair, replacement of complete gasket set, refilling the oil duly filtered / dehydrated, topping up with new oil, carrying out routine tests, welding work, leakage repairing and complete servicing including transportation back to site, testing and commissioning of the repaired transformer at site on full load after making cable and earthing connections complete all as specified and as directed. Note :- New transformer oil, Dehydration of transformer oil, LT /HT bushings/studs shall be measured and paid separately.
All as per item No. 25 here in before but 100 to 200 KVA all as specified and as directed.
M&L for rewinding in repair of HT winding with Copper strip of suitable size/gauge, fixing the coil in position in core assembly and making connection as per original pattern including providing insulation, varnish, all as specified and as directed
(a) Transformer 315 to 500 KVA capacity
(b) Transformer 100 to 200 KVA capacity
All as per item No. 27 here in before but LT limbs of following capacities :-
(a) Transformer 315 to 500 KVA capacity
(b) Transformer 100 to 200 KVA capacity
S&F in repairs brass metal studs nut & washers suitable for 11 KV HT side of transformer upto 800 KVA all as specified and as directed
S&F in repairs brass metal studs nut & washers suitable for 11 KV LT side of transformer upto 800 KVA all as specified and as directed
S&F in repairs HT bushing suitable for upto 800 KVA Transformer complete all as specified and as directed
S&F in repairs LT bushing suitable for upto 800 KVA Transformer complete all as specified and as directed
S & F Temperature gauge suitable size for transformer of capacity 800 KVA all as specified and as directed
Supply and fill in repairs existing breather silica gel of superior quality for transformer breather all as specified and as directed
S&F in repairs transparent PVC material breather assembly for transformer upto 800 KVA capacity all as specified and as directed
M & L for transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine to remove impurities from oil such as moisture, dirt, air and other gases and to improve BDV upto 50KV at 2.5mm air gap all as specified and as directed. Note: Transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine shall be done on existing installation place on same day.
M&L for new transformer oil for topping up or for replacement in Transformers /Servo Voltage stabilizer complete all as specified and as directed Note: Oil shall be in company sealed barrel having BDV not less than 60 KV
M &L for Dismantling top cover, lifting complete core assembly of transformer taking out old gasket set and drain out existing complete oil servicing of complete transformer, painting inner surface replacing nuts bolts complete as required and reassemble the transformer including testing and installation at site for upto 800 KVA transformer. Note :- Oil, and HT/LT bushing shall be measured and paid separetly.
M & L for preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc of transformers upto 800 KVA complete all as specified and as directed.
Shifting of transformer from one site to another in case of emergency by disconnecting HT/LT cable and earthing connections of transformer of capacity 200 to 500 KVA , 11 KV/433 volts 3 phase floor mounted incl making all electrical connections at the place of installation complete all as specified and as directed. Notes :- (i) The rate for transport and lifting of transformer by crane is deemed to be included in the rate quoted. (ii) The rate is deemed to be inclusive for disconnection & making connnections of transformer as required.
Material and labour for preparation of old painted surface of LT panel by removing all dust etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including of identification etc complete all as specified and as directed.
M & L for preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc of transformers upto 500 KVA all as directed.
Servicing and repair/maintenance of APFC panel Board heavy duty auto/manual operation including repairs/replacement of fuses, fuse link, contacts, current transformers and checking, replacing of defective control wiring if any replacement of defective cable lugs, patch work welding, replacement of defective door hinges including painting with two coat of sythetic enamel paint over one coat of red oxide primer etc and testing and commissioning complete for upto 100 KVAR complete all as specified and as directed.
Supply & fixing power factor correction capacitors Heavy duty capacitor for 3 phase, 440 V & 50 HZ, AC electric supply system for permissible non-linear load 15% of 5 KVAR capacity complete all as specified and as directed.
All as per above item No 44 but capacity 7.5 KVAR.
All as per above item No 44 but capacity 10 KVAR.
All as per above item No 44 but capacity 15 KVAR.
All as per above item No 44 but capacity 25 KVAR.
Supply and fixing in repair 8 stage intelligent APFC controller, CT secondary 5 Amps, 415V, microprocessor based with programable sequence controller, fault indicator, power factor indicator, power factor indicator complete all as specified and directed.
Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper busbar size 50 x 6 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :- (i) MCCB 400 Amps, 4 Pole, 36 kA, Adjustable thermal and fixed magnetic setting - 01 No (Incoming). (ii) MCCB 250 Amps, 4 pole, 25 kA, Adjustable thermal and fixed magnetic setting - 01 No (Outgoing). (iii) MCCB 160 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 01 No (Outgoing). (iv) MCCB 100 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing). (v) MCCB 63 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 01 No (Outgoing).
(vi) Onload Changover switch 400 Amps - 01 No (vii) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO) (viii) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set. (ix) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot
Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper busbar size 50 x 6 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :- (i) MCCB 400 Amps, 4 Pole, 36 kA, Adjustable thermal and fixed magnetic setting - 01 No (Incoming). (ii) MCCB 250 Amps, 4 pole, 25 kA, Adjustable thermal and fixed magnetic setting - 01 No (Outgoing). (iii) MCCB 160 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 01 No (Outgoing). (iv) MCCB 100 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 01 No (Outgoing). (v) MCCB 63 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 01 No (Outgoing).
(vi) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO) (vii) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set. (viii) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot
Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CRPI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper busbar size 25x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :- (i) MCCB 160 Amps, 4 Pole, 25 kA, Adjustable thermal and fixed magnetic setting - 01 No (Incoming). (ii) MCCB 100 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing). (iii) MCCB 63 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing). (iii) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO)
(vii) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set. (viii) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot
Supply and installation of 100 KVAr APFC panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4 wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20 cm including copper busbar size 25x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :- (i) MCCB 160 Amps 4 Pole 25 KA (ii) 8 step intelligent power factor controller - 01 set (ii) Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 volt & 50 HZ system for permissible non-linear load 15% of 5 KVAR capacity with 10 Amps TP MCB, Duty contactor, Auto/manual switch, illuminated push button/indicators. - 02 set (iii) - do - but 10 KVAR capacity with 16 Amps TP MCB - 03 set (iv) - do - but 15 KVAR capacity with 32 Amps TP MCB - 01 set (v) - do - but 20 KVAR capacity with 32 Amps TP MCB - 01 set (vi) - do - but 25 KVAR capacity with 40 Amps TP MCB - 01 set
(vii) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO) (viii) Indicators with neon lamp with RYB shade, 240 volts 50 c/s of suitable capacity resistance - 01 set. (ix) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments - 01 lot
M & L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 03 of SSR part-I Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia with funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge.
M & L for Heavy gang operated triple pole mechanically operated air break on load disconnecting switch each pole consist of galvanised iron base HT 11KV with polymer insulators per phase non ferrous knife and spring loaded contact GI pipe of adequate length for operation from ground level and operating handle complete in both OFF and ON position capacity 11 KV 200 Amps including taking down old one.
M & L for 11 KV Heavy Drop Out Fuse complete in each pole consist of galvanised iron base HT 11KV with polymer insulators including taking down old one all as specified and directed.
M&L for HT 11 KV Disc type insulator with hardware, single disc assembly, polymeric insulator, vitreous145mm high and 255 mm dia and socket type, including taking down old unsv.
S&F for Pin type polymer insulator including one galvanised mild steel spindle two GI washers and one GI iron nut 150mm height, 150mm dia for 11 KV grade including dismantling the old U/S insulator.
S & F lightening arrestor HT 11000 KV pole mounting with polymeric insulator complete with all fittings transmission class nominal discharge current upto 65 KA including removing the defective one complete all as specified and directed.
M&L for servicing of 11 KV Indoor Vaccum Circuit Breaker (VCB) of any make at NAD/MO Goa sub station which includes disconnecting, removing old grease, re-greasing of moving parts with recommended grease and checking of the entire breaker trolley mechanism,checking of the closing and tripping time in milli seconds using high precision time scope timer, measurements of contact resistance and insulation values, cleaning the complete VCB by opening front and back doors, tightening of cable connections, checking & repairing the current circuit panel wiring, relay etc and re-assembling & re-installing the VCB back to ts original position including testing and commissioning after completion of work all as specified and as directed. NOTE : The cost for minor spares such as operating handles, screws,nuts,bolts, washers indicating lamps, lamp holders, HRC fuses,fuse carriers etc shall be included in the rate quoted for the item. Servicing shall be carried out as per manufacturer recommended checklist.
M & L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV HT cable by giving high voltage surge and to find out excact location of fault all as specified & directed. Note:- Excavation and earth work will be measured and paid for searately in respective item of sch.
S and G Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .