Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹38.6 L+₹20,240.50 (0.53%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹40.9 L+₹2.5 L (6.55%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹46.0 L+₹7.6 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹47.6 L
EMD Value
₹95,200
Closing Date
2 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
SPECIAL REPAIR TO BLDG NO T-30, T-20, T-60 and P-17 IN AOR OF AGE B/R DETT-B AND AGE E/M UNDER GE 862 EWS
2023_MES_621903_1
GER-50/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹95,200
Yes
18 Dec 2023
6 Oct 2023
4 Nov 2023
6 Oct 2023
2 Nov 2023
19 Oct 2023
Amount
Sch 'A' Part-I (B/R works) Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in curve roof (of any radius) covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F for rolled mild steel in joist, channel, agnle, or tee sections, and cross beams, hips and jack rafters, purline, fixed independently, without connecting plates, etc., (Cut to ordinary lengths i.e. within 20mm of the length as indicate) in Fe-290 Gde E-165 quality 'B', complete all as specified and directed.
S&F for mild steel structural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level, complete all as specified and directed.
M&L for 75mm thick plain cement concrete, type C-2, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for vitrified tiles light shade, double charged (premium quality) 10 mm thick (square/ rectangular) polished, area of each tiles n. exc 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4 including dismantling of old tiles, and removing rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4 including dismantling of old tiles, and removing rubbish off the premises complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm /450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:4 including dismantling of old tiles, and removing rubbish off the premises complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and any position not otherwise specifically provided for, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed.
Demolition of reinforcement cement concrete in roofs, beams, staircase, chajja and similar suspended work, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design Mix) (using 20mm graded crushed stone aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 5cm wide and n. exc 10cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, complete all as specified and directed.
Description all as per srl item No. 21 above but except brick in CM 1:6. NOTE: Old brick retrieved from demolition shall be used.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
Description all as per srl item No. 23 above but except stone. NOTE: Old stone retrieved from demolition shall be used.
M&L for plain cement concrete 1:3:6 type B-2 (40mm graded crushed aggregate ) as in surface channels and drains, complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed.
M&L for Add or deduct for each 25mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc, complete all as specified and directed.
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick or stone masonry work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick, stone or concrete work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening including 3mm thick wall care putty, complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls by scrubbing the old surface and applying one coat of distemper oil emulsion over a coat of chalk whitening, complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls by scrubbing the old surface and applying two coat of distemper oil emulsion over a coat of chalk whitening, including 3mm thick wall care putty, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of exterior emulsion weather proof paint of apex ultima over and including a coat of primer, complete all as specified and directed.
M&L for complete removal of existing treament of wall by scrubbing the old surface and applying two coats of exterior emulsion weather proof paint of apex ultima over and including a coat of primer after preparation of surface, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 Sqm and not exceeding 4.0 Sqm each removing form site, complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing from site, complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-1 using 20mm graded crushed stone agregate complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F for box type steel windows with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for box type steel windows with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square, complete all as specified and shown on drwaing in SSR Part-II (2020) directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & shown in drawing mentioned in SSR Part-II 2020, complete all as specified and directed.
S&F for box type steel windows with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for box type steel windows with side hung shutters including box type hinges with steel handle, hold fast and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F for steel ventilator with top hung shutters including hinges with steel peg stay, welded complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks or portion framed and hung as gates, including pintel hinges, stops, hand made sliding bolt etc and similar work conforming to Fe 290 or E-165 work including welded fabricks frames, gate and framed truss etc including dismantling old steel work, complete all as specified and directed.
S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in squares n . exc 0.50 sqm in each pane complete after hacking out old broken glass all as specified and directed.
S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in squares n. exc 0.50 sqm in each pane complete all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of pink primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for preparation of old painted steel surface exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wooden surface exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F for 100mm long mild steel butt hinges medium weight colled rolled (ISI marked), complete all as specified and directed.
S&F in repair for stainless steel curtain rod of 20mm dia, complete all as specified and directed.
S&F in repair for bracket and finials of stainless steel of 'T' and 'L' type (colour and design approved by GE) for curtain rod stainless steel 20mm dia including fixing to walls with MS full screws (including fixing of wooden pieces of required size of walls) complete as in repair all as specified and directed .
M&L for 125 mm long extruded aluminium alloy handles size fabricated type anodised (ISI marked), complete all as specified and directed.
M&L for 300mm long (lenth of bolt) aluminium alloy, anodised, sliding door bolt with hasp, stapl (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruced sections or cast aluminium alloy anodised (ISI marked) complete all as specified and directed.
M&L for 125 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked), complete all as specified and directed.
M&L for 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked), complete all as specified and directed.
S&F in repair 140mm long floor door stopper of aluminium alloy anodised body and tongue with hard drawn steel spring, complete all as specified.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, including taking down old tubing complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, including taking down old tubing complete all as specified and directed.
S&F in repair for 15mm bore bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair for 15mm bore angle valve cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down for high pressure, screwed both ends for iron pipe or for unions complete all as specified and directed.
M&L in repair for 15mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
M&L in repair for 20mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
S&F in repair 32mm dia PTMT waste coupling (half or full threaded), fixed to stainless stee sink/ WHB complete all as specified and directed.
S&F in repair for chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange aluminium anodised including one pair of brass chromium plated brackets, complete all as specifed and directed.
S&F for grating doom 125 mm of PTMT (Min Weight 40 Gms) with waste hole, complete as in repair all as specifed and directed.
S&F in repair for PVC connection 15 mm x 600 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
S&F in repair for 20mm dia ball bras valves high pressure with polythene float and flynut screwed for iron pipe or brass ferule and fixed complete all as specified and directed by Engr-in-Charge.
S&F in repair vitreous China wash basin, white, flat back, size 550x 400mm including waste pipe and brackests (excluding taps, waste chain and plug and porcelan stopper), complete all as specified and directed.
S&F in repair for 15mm bore pillar tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair for PVC (SWR) pipes 110mm bore, type 'B' , single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and directed.
S&F in repair for PVC (SWR) pipes 75mm bore, type 'B' , single socketed in any length with rubber ring joints, laid in trenchs or in floor complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F in repair 75 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement and connecting to waste pipe, complete all as specifed and directed.
S&F in repair Soap dish vitreous china white of size 160x160x90mm including fixing with chromium plated brass screw and wooden/ plastic cleats, complete all as specifed and directed.
S&F in repai for viterous china wash down water closet pan (EWC), white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and inlcuding flush pipe) including set of CP jet spray with PVC pipe of superior quality fixe to iron pipe complete all as specified and directed.
S&F in repair for 15mm bore two way bib cock, cast copper alloy, chromium plated, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair for 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with 32mm dia flush pipe of polythylene of high density, complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple after dismantling of old unserviceable tank, complete all as specifed and directed.
S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc, complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
Dismantling of timber fillets, rails, posts, rafters, purlin etc under 40 Sqcm in section, complete all as specified and directed.
S&F clean sawn second class hardwood battens for wall panelling work having sectional area exc 15sqcm but n. exc 25sqcm , fixed to wall at 60cm centre to centre complete all as specified and directed.
S&F for PVC paneling as in walls consisting of 5mm thick wood grain printed PVC sheet fixed in site on PVC frame work, including 5mm thick PVC sheet fillet of width 35mm, fixing on wall to make PVC frame for wall panelling after dismantling existing wall paneling, complete all as specified and directed.
Complete removal of existing water proofing treatment / prepartion of new surface, over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in cement mortar 1:4 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm & minimum 3mm thick reinforced with polyster non wove fabric, APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed. (ii) Rate of WPC will be included in the quoted rate.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base of floors for tiling, complete all as specified and directed.
M&L for coloured chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick with grey cement and pigment, set and jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 20 mm thick screed bed in cement mortar 1:4, including dismantling of old tiles and removing rubbish outside of the premises complete all as specified and as directed.
M&L for Machine cut kota stone slab (mirror polished) flooring 18-20mm thick as in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar 1:4 of any size complete all as specified and directed.
M&L for Machine cut kota stone slab(mirror polished) flooring 18-20mm thick as in skirting and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar 1:4, complete all as specified and directed.
M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as directed and as approved.
M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall below concrete or masonry apron using chemical emulsion at the rate of 2.25 litres per linear meter including drilling and plugging holes etc in apron complete all as directed and as approved.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including PVC casing and caping medium grade of 25mm width complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 101 above but for one 3 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 101 above but for one 3 pin 6 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 101 above but for one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
S&F for switch socket combination 2 in 1, 3 pin, 5 amp flush type complete all as specified and directed.
S&F for socket 2 in 1, 5 pin, 5 amp flush type complete all as specified and directed.
S&F for switch socket combination 2 in 1, 5 pin, 15 amp flush type complete all as specified and directed.
S&F for socket outlet 2 in 1, 5 pin, 15 amp multipurpose, flush type complete all as specified and directed.
S&F for ceiling rose 3 phase/PVC/polycarbonate isolated body surface bakelite 2 to 3 terminals complete all as specified and directed.
M&L for ceiling fan regulator elctronic, flush type, hum free suitable to control speed of fan in five step, stepped type, 240 volts AC complete all as specified and directed.
S&F in repair for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 9watt complete all as specified and directed.
M&L in repair for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type ultra slim with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed.
S&F in repair for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm, including LED driver, complete all as specified and directed.
M&L in repair for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-54 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L in repair for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-54 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L in replacement for MCB single pole 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L in replacement for MCB Single pole & neutral /DP 240 volts any rating from 40 to 63 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners, overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items, complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades to store and painting of ceiling fans complete, in site with sythetic enamel paint by spraying including fillings cavities with filler, one coat of after cleaning all dust etc, complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 Sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for foundation, laying of cable/pipes/poles etc and getting out, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material, not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified in SSR Part-I and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for laying unreinforced precast factory made concrete cable cover, class LV, type -I, flat, size 250mm x 150mm x 40mm, complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of charcoal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2009 including testing on completion including taking down existing unserviceable earthing complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
S&F in repair for LED recess mounting high lumen panel light 36 watts, 2 x 2 feet with white power coated CRCA housing with high power LEDs, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230v complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height complete all as specified and directed
M&L in repair for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
S&F in repair for LED street light fitting 35 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and including bracket made up of 40mm bore light grade GI pipe 1.2mtr long including necessary bending and welding etc complete as in repeir all as specified and directed
S&F in repair for mount LED Bollard light fitting 10watt, integral decorative with polycarbonate diffuser with IP 65 protection including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable, complete all as specified and directed.
S&F for FRP looping box of size 250x200x100 mm with aluminium bus bar (02 Nos) 100 Amps capacity connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, 'C' series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall etc and after taking down old unserviceable looping box of any type complete all as specified and directed.
S&F in repair for LED flood lights of 70 watt , 230 V AC outdoor type thermal management in multiple optics and equipped with IP-65 protection ,with impact and corrosion resistant complete driver and lamp complete necessary fixing arrangements at any height and all as required at site, complete all as specified and directed.
S&F for LED street light fitting of 45 watt , 230 V AC outdoor type, made in pressure diecast housing with epoxy powder coated dark graphite grey colour finish prismatic polycarbonate cover with individual LED lenses with IP-65 protection complete with all accessories and necessary fixing arrangements at any height including three core 0.5 sqmm copper cable from connector to fitting and including bracket made up of 40mm bore light grade GI pipe 1.2mtr long including necessary bending and welding etc and fixed the bracket on wall/pole, steel /PCC surface by providing suitable MS iron clamp of size 25x4mm 02 nos length as required at site to the bracket pipe and painting to MS clamps and fixing with suitable nuts, bolts and washer includin taking down old street light with bracket complete all as specified and directed.
S&F in repair for LED post top lantern light fitting 40watt, with cast aluminium spigot lid cover and clear cover with IP-65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the disturbed portion to match with existing surface with three core 0.5 sqmm copper cable, complete all as specified and directed.
M/S BADRI NATH GUPTA
VIJAY KUMAR SURI AND SONS
M/s Anil Engineers & Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .