| 1 | L1₹35.9 LAccepted-AOC 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.0 L+₹1.2 L (3.23%)Rejected-Finance HOUSE NO 11 BYE LANE 1 EAST PUB SARANI SANKAR DEB PATH CHANDMARI DIST KAMRUP METRO ASSAM 781003 | GUWAHATI | KAMRUP METRO | ASSAM | 781003 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹39.0 L+₹1.3 L (3.37%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹39.3 L+₹1.5 L (4.05%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹40.0 L+₹2.2 L (5.83%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹49.9 L
EMD Value
₹99,700
Closing Date
9 Feb 2024, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION INCLUDIN PAINTING SERVICING REWINDING OVERHAULING OF FANS AND REP MAINT OF LIGHT FITTINGS AND ALLLIED WORKS UNDER GE NARANGI
2024_MES_637414_1
8925/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹99,700
Yes
29 Feb 2024
13 Jan 2024
12 Feb 2024
13 Jan 2024
9 Feb 2024
27 Jan 2024
Amount
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 2 here-in-before but for one light point controlled by 2 way 5 Amp switch
All as per item No 2 here-in-before but for bell /buzzer point controlled by one push button on the same board with other switches or independent with cable complete.
All as per item No 2 here-in-before but for one 3 pin 5 Amp switch socket outlet on independent board.
All as per item No 2 here-in-before but for one 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 2 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC rigid conduit ( concealed) with all accessories including febricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screws for mounting switches, sockets, regulators etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 8 here-in-before but for one light point controlled by 2 way 5 Amp switch
All as per item No 8 here-in-before but for one bell point controlled by one switch 5 Amps bell push on the same board with other switches or independent with cables
All as per item No 8 here-in-before but for one 3 pin 5 Amp switch socket outlet on independent board
All as per item No 8 here-in-before but for one 3 pin 5 Amp switch socket outlet on same board with other switches.
All as per item No 8 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F in repair modular switch one way 6 Amps 1 module complete all as specified and as directed.
S&F in repair modular switch one way 16 Amps 1 module complete all as specified and as directed.
S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F bell push, flush type, 5 Amps complete all as specified and as directed.
S&F in repairs, modular bell push, 6 Amps 1 module complete all as specified and as directed.
S&F in repair modular socket 6 Amps 2/ 3 pin, combined 2 module complete all as specified and as directed.
S&F in repair modular socket 16 Amps 2/ 3 pin, combined 2 module complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F lamp holder insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F in repair modular fan regulator, 120 W two module size, flush type complete all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed.
S&F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 1 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 3 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 4 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 6 module all as specified and as directed.
S&F in repairs, metal flush box 3 module all as specified and as directed.
S&F in repairs, metal flush box 4 module all as specified and as directed.
S&F in repairs, metal flush box 6 module all as specified and as directed.
S&F in repairs, LED fitting 1 x 20 W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed.
S&F in repairs, decorative hexagonal bulk head LED luminaire 10 Watt, 6000K with IP 66 protection complete all as specified and as directed.
S&F in repairs, LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt, 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size
S&F in repairs, LED 40W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete.
S&F in repairs, wall decorative fixtures in durable body and designer mesh in gold finish suitable for 8/10 Watt LED lamp of B-22, including lamp of 8/10 Watt.
Taking down unserviceable Street/Security/Flood light fitting from any height/wall etc of any make and type, repairing the same at site by opening the cover, replacing unserviceable parts such as LED Driver, lamps, holder , capacitor including rewiring with 2.5sqmm copper conductor cable, multistranded and refixing the same at existing position. (Note: New parts required for replacement shall be paid under relevent items as Supply only).
Taking down unserviceable high mast light fitting from any height/wall etc of any make , repairing the same at site by opening the cover, replacing unserviceable parts such as LED Driver, lamps, holder , capacitor including burnt cable and refixing the same at existing position. (Note: New parts required for replacement shall be paid under relevent items as Supply only).
S &F Security light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 10 kV complete also tested for 440 Volt for 8 hour Phase to phase without any damage including provision of 32mm dia GI pipe medium grade bracket bend to required shape of length 1.5m long including taking down old unserviceable light fittings with brackets complete all as specified and as directed. ( NOTE :(i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
Disconnecting the main power supply to distribution box and making proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of preconnected MCBs by replacing screws of DB covers, earth wires, and other necessary connecting items and dressing of wires inside the DB with cable tie complete all as directed.
S &F Energy saving new generation environmental freindly long life versetile pressure die cast aluminium IP 66 flood light fitting with high power LEDs as light source and electronic driver of capacity 70 Watts with pre wired and necessary mounting arrangements with lumen efficiency >=110 LPW including SPD 10 KV with provision of 2.5 sqmm three core flexible aluminium conductor cable, multistranded connecting to existing point in Hanger Beam angle of any description including taking down old unserviceable light fittings complete all as specified and as directed. ( NOTE :(i) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
S &F Energy saving new generation environmental freindly long life versetile pressure die cast aluminium IP 66 security light fitting with high power LEDs as light source and electronic driver of capacity 45 Watts with pre wired and necessary mounting arrangements with lumen efficiency >=110 LPW including SPD 10 KV with provision of 2.5 sqmm three core flexible aluminium conductor cable, multistranded connecting to existing point in Hanger Beam angle of any description including taking down old unserviceable light fittings complete all as specified and as directed. ( NOTE :(i) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
Supply only electronic LED driver of capacity 45 Watt suitable for 220/230/240 Volt complete.
Supply only electronic LED driver of capacity 60Watt suitable for 220/230/240 Volt complete.
Supply only electronic LED driver of capacity 90Watt suitable for 220/230/240 Volt complete.
Supply only electronic LED driver of capacity 100Watt suitable for 220/230/240 Volt complete.
Supply only electronic LED driver of capacity 150Watt suitable for 220/230/240 Volt complete.
Supply only electronic Electronis surge protection device ( SPD) 10 KV suitable for LED security light of capacity 45 Watt suitable for 220/230/240 Volt complete.
Supply only electronic Electronis surge protection device ( SPD) 10 KV suitable for LED security light of capacity 60 Watt suitable for 220/230/240 Volt complete.
Supply only electronic Electronis surge protection device ( SPD) 10 KV suitable for LED flood light of capacity 90/100 Watt suitable for 220/230/240 Volt complete.
Supply only electronic Electronis surge protection device ( SPD) 10 KV suitable for LED flood light of capacity 150 Watt suitable for 220/230/240 Volt complete.
S&F in repairs, Power contactor, 4 pole, current carrying capacity 40 A complete.
S&F in repairs, DIN type Astronomical timer, three phase programmable every 15 minutes and back up of 100 hrs current carrying capacity 16 A complete.
S&F in repairs, LED35 W building security light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed .
S&F in repairs, LED aviation light energy saving new generation environmental friendly long life versetile pressure die cast aluminium housing with polycarbonate enclosure with pre wired and and necessary mounting arrangements with provision of 3 core multistranded copper conductor cable of size 23/0.193 including 40mm dia GI pipe medium grade bracket bent to required shape 1.5m long complete all as specified and as directed .
M&L in repair for street light fitting bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape for fixing street light luminaries all as directed, length of GI Pipe shall not be less than 1.5 mtrs with applying two coats of aluminium paints over a coat of red oxide primer complete all as specified and directed.
S&F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, protection class IP-43 with min provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed .
S&F in repairs, factory made, sheet steel distribution boards, IP-43 of double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate.
S&F in repairs, single pole & neutral DBs, 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar grouted in wall in PCC 1:2:4 type B-1 complete all as specified and as directed.
S&F in repairs, MCCB four pole 63A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed.
S&F in repairs, MCB TPN of capacity 40A to 63A,10 KA, type 'C' curve, 240 Volts, complete all as specified and as directed.
S&F MCBs, SPN 32 Amps, 240v 10 KA, 'C' curve complete all as specified and as directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F in repair Exhaust fans AC single phase 230/ 240 V ,50 Hz metallic heavy body of size 300 mm sweep, 1400 RPM with louver fixing with 4 no hold fastener nut and bolt with washer and connecting with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm including civil work opening on wall of suitable size and 400x400x6mm thick BWR graded plywood making suitable hole for fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and writing MES No. with black synthetic enamel paint with 2cm high letter and making good surface complete all as specified and directed.
S&F in repair wall fan AC single phase 230/240 V , 50Hz, metallic heavy body of size 400mm sweep including necessary connecting up with PVC flexible insulated multistranded copper conductor cable of size 1.5 sqmm and making good disturbed surfaces complete.
Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, and transporting from any location inside army area to MES E/M store yard, and refixing on same location or other location after repairing/painting complete all as specified and as directed.
Strip opening of ceiling fan 1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge. Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC ceiling fan 1200/ 1400 mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing of size 6201/6202 for any type/make of ceiling fan 1200/1400 mm sweep all as directed. (Make : NBC/SKF/SBBI)
Supply only fan capacitor 2.5 Mfd suitable for 1200/1400 mm sweep ceiling fan all as directed. (Make : NBC/SKF/SBBI)
Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required.
Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed.
Taking down exhaust fan of size 200mm to 450mm sweep of any make and transporting from any location inside army area to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note :- Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC exhaust fan 200mm to 450mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing suitable for exhaust fan upto 450mm sweep all as directed. (Make : NBC/SKF/SBBI)
Supply only condenser ISI marked 230/240/250 volts AC 4 Mfd suitable for exhaust fan including condenser spacer and soldering of condenser wire to fan wire (Make : Usha/Asian/EPCOS/Universal).
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable , etc. n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thick in soft /loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exc 50m and depositing at level not exc 1.5m above the starting point complete all as specified and as directed.
Taking out old unserviceable UG cable of any size/ type from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed. ( Note : Excavation and earth work shall be measured and paid seperately).
M&L for relaying of faulty UG XLPE cable of size 3.5 core , 35/50/70 sqmm alongwith brick protection, sand cushioning etc as obtained from taking up/down old cable here in before in trenches/ wall/ roof etc. including cutting and jointing through cable jointing kit as required and connecting to the main switches/cut outs MCB/MCCB with necessary lugs after cutting to required length complete all as specified and as directed.
M&L for relaying of faulty UG XLPE cable of size 4 core ,25 sqmm alongwith brick protection, sand cushioning etc as obtained from taking up/down old cable here in before in trenches/ wall/ roof etc. including cutting and jointing through cable jointing kit as required and connecting to the main switches/cut outs MCB/MCCB with necessary lugs after cutting to required length complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 6 sqmm 2 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 4 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size70 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size95 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for sub class 'B' old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
M&L for GI pipe light grade 40mm bore with all fittings as in protection of cable at road crossing/hard standing/pole protection fixed with clamps, including taking up/ down old pipe complete all as speciffied and as directed
Refixing only serviceable GI pipe light grade 40mm bore as obtained from taking up/down cablewith provision of new fittings as in protection of cable at road crossing/hard standing/pole protection fixed with clamps, including taking up/ down old pipe complete all as speciffied and as directed
M&L for GI pipe light grade 50mm bore with all fittings as in protection of cable at road crossing/hard standing/pole protection fixed with clamps, including taking up/ down old pipe complete all as speciffied and as directed
Refixing only serviceable GI pipe light grade 50mm bore as obtained from taking up/down cablewith provision of new fittings as in protection of cable at road crossing/hard standing/pole protection fixed with clamps, including taking up/ down old pipe complete all as speciffied and as directed
Refixing only serviceable GI pipe light grade 80mm bore as obtained from taking up/down cablewith provision of new fittings as in protection of cable at road crossing/hard standing/pole protection fixed with clamps, including taking up/ down old pipe complete all as speciffied and as directed
M&L for erection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundation duly painted painted with two coats of Aluminium paint over a coat of red oxide primer including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2( using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-1( using 20 mm graded crushed stone aggregate) as in coping including necessary form work to the new/existing steel pole complete all as specified and as directed.
M&L for stay assembly comprising 14mm dia iron stay bow, stay strand wire of size 7/3.15mm with stay rod of diameter 16mm complete with all accessories as shown in electrical plate no. 1 of SSR part-I 2009 including dismsntling of old stay assembly of any description with foundation, etc. complete all as specified and as directed.
M&L for loop type insulator, vitreous porcelain, white, brown or green with overall dimension 95mmX65mm, clearence of hole 16mm suitable for 1100 Volts complete all as specified and as directed.
M & L for aluminium conductor, steel reinforced (ACSR) of any size as approved on HT/LT Poles including straining, binding to insulators with aluminium binding wire with connectors, etc, providing PVC sleeves for jumpers as in OH conductors including dismantling of old ACSR or AAD conductors complete all as specified and as directed.
Dismantling of old cross arms of mild steel channel or angle section complete all as specified and as directed.
M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Refixing only serviceable Cross arms, bracings, supports, clamps, eye hook and back plates as obtained from dismantling of old cross arms including provision of new bolts, nuts etc . in any shape or size as indicated or directed including painting with one coat of aluminium paint complete all as specified and as directed.
Dismantling of old insulator any type and description from existing poles complete all as specified and as directed.
M&L for pin type insulators LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, iron nut, 100 mm height, 65 mm dia complete all as specified and as directed.
Refixing only serviceable pin type insulators as obtained from dismantling of old insulator including provision of one galvanized mild steel spindle, two galvanized iron washers, iron nut, etc complete all as specified and as directed.
M&L for shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including galvanised mild steel straps, washers, insulator bolts, nuts 12 mm dia, 75 mm height and 90 mm dia, section of straps 31mmx3mm of insulator complete all as specified and as directed.
Refixing only serviceable shackle type insulators as obtained from dismantling of old insulator including provision of new bolts, nuts, washers , etc complete all as specified and as directed.
Dismantling of old earth wire, craddle guard etc of any description and size complete all as specified and as directed.
M&L for galvanised steel wire 3.15mm or 4.00mm dia as earth continuity conductor and fixed to pole, binding with aluminium binding wires complete all as specified and as directed.
M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m between two electric poles having 4 Nos of ACSR conductors of any size including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as directed to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 4 Nos wire of LT over head line and 2 Nos of earth wire.)
M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m between two electric poles having 2 Nos of ACSR conductors of any size including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 2 Nos wire of LT over head line and 1 Nos of earth wire.)
S&F PVC/Fibre seperator for LT lines 1100 volts overhead conductors 2 wire system for horizontal spacing between the conductors fixed with nuts, bolts, washer etc. complete all as specified and as directed.
S&F PVC/Fibre seperator for LT lines 1100 volts overhead conductors 4 wire system for horizontal spacing between the conductors fixed with nuts, bolts, washer etc. complete all as specified and as directed.
M &L Complete removal of old paint by scrapping and removing for preparing surfaces of existing old steel tubular poles 8.5m/9.00m long including scrapping, brushing down old paint with emery paper and applying one coat of aluminium paint including cross arms, street light brackets etc and making strip upto 1.5m above ground level by black/yellow paint in alternate layers with numbering of poles complete all as specified and directed.
M & L for Prunning / trimming the branches of trees if any along overhead line, 3 m on all side below/ above/ sides of overhead line and removing the same upto a distance of 150m, each span not exceeding 45 m complete all as specified and as directed.
M & L cutting grasses, shrubs/herbs surrounding LT poles, feeder pillar box installations by mechanical or manual T&P, removing the debris at a distance not exceeding 50m and depositing where directed complete all as specified and as directed.
S&F in replacement MCCB with Thermal - magnetic release of 250 Amps, 4 Pole, 415V,36 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in replacement MCCB with Thermal - magnetic release of 200 Amps, 4 Pole, 415V,36 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in replacement MCCB with Thermal - magnetic release of 160 Amps, 4 Pole, 415V,36 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in replacement MCCB with Thermal - magnetic release of 100 Amps, 4 Pole, 415V,50 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in replacement MCCB with Thermal - magnetic release of 63 Amps, 4 Pole, 415V,50 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories complete all as specified and as directed.
S&F in repair 3 phase single function LED Voltmeter flush mounting 96X96 mm of input voltage measurement range 50-520 VAC (P-P), 5 A, accuracy class 1 for LT panel board complete all as specified and directed
S&F in repair LT CTs of rating 200/5 Amp complete all as specified and directed.
Cutting out burnt out cable end and reconnecting with providing new lugs, tapes etc. for cable of size 25 sqmm to 50 sqmm 3.5 core complete all as specified and directed.
Cutting out burnt out cable end and reconnecting with providing new lugs, tapes etc. for cable of size 70 sqmm to 95 sqmm 3.5 core complete all as specified and directed.
Cutting out burnt out cable end and reconnecting with providing new lugs, tapes etc. for cable of size 120 sqmm to 300 sqmm 3.5 core complete all as specified and directed.
S&F in replacement four pole onload changeover switch with advanced neutral having current rating 400 Amps with phase barrier and handle with door interlock kit in open execution complete all as specified and directed.
S&F in replacement four pole onload changeover switch with advanced neutral having current rating 200 Amps with phase barrier and handle with door interlock kit in sheet metal enclosurecomplete all as specified and directed.
S&F in replacement aluminium conductor cable 2.5 sqmm 2 core as in panel or street light complete all as specified and directed.
S&F aluminium thimble for cable of size 300sqmm/400sqmm complete all as specified and directed.
S&F aluminium thimble for cable of size 95sqmm/120sqmm complete all as specified and directed.
S&F aluminium thimble for cable of size 70sqmm complete all as specified and directed.
S&F aluminium thimble for cable of size 50sqmm complete all as specified and directed.
S&F aluminium thimble for cable of size 35sqmm complete all as specified and directed.
S&F aluminium thimble for cable of size 25sqmm complete all as specified and directed.
S&F aluminium thimble for cable of size 16sqmm complete all as specified and directed.
S&F aluminium thimble for cable of size 10sqmm complete all as specified and directed.
S&F in replacement rubber mat suitable for LT panel of size 2mX1mX15mm thickcomplete all as specified and directed.
S & F CPRI approved Outdoor type LT feeder panel of thickness 2.00mm factory made both side openable having rain protection with slanted roof top, door pated with rubber gasket, water tight IP-42 protection having proper locking arrangement including painting with powder coated paint complete having cable entry space from down side for miniumum 4 Nos. of cable of size 50 to 95 sqmm , internal wiring complteconnecting incoming/outgoing cable with suitable size of lugs and comprising the following. (i) 200 Amps raed copper bus bar TPN of length 150cm each duly insulated with coloured PVC sleeve as per standard colour code. (ii) Incomer ; MCCB 4 pole 125 Amps, thermal magnetic type DN2-250D with breaking capacity 25 KA with thermal magnetic release at 415 Volts with spreader terminal : 01 NO.
S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 70-95 Sqmm 3.5 core complete all as specified and as directed.
S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 35-50 Sqmm 3.5 core complete all as specified and as directed.
S&F in replacement Aluminium strip 25X3.15mm with saddles and fixing screws and run through wall provided with nonconducting plank as in down conductors of lighting arrestor complete all as specified and as directed.
S&F in replacement copper strip 20X3.15mm burried in ground/ fixing with saddle and screws for roof and wall as earth continuity conductor complete all as specified and as directed.
S&F in replacement Air termination single pointed copper rod 12mm dia and 300mm long fixed with brazing complete all as specified and as directed.
S&F in replacement Test point terminal block made of gun metal or phosporous bronze of size 75mmX75mmX25mm, drilled and screwed including three numbers 8mm dia 25mm long hex head screws complete all as specified and as directed.
M& L for Manual boring under roads / hard standing by required T&P without disturbing the top surface of the road for passing the cable in GI Pipe of 40 mm to 80mm dia complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Two runs of cable and one run of PVC conduit will be measured as one Rm unit.
M & L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Two runs of cable and one run of PVC conduit will be measured as one Rm unit.
M&L for earthing complete with Copper earth plate electrode of size 60cm x 60cm x 3.15mm buried directly in ground vertically at a depth not less than 1.50 metre below normal ground level connected to copper earth strip 20X3.15m thick surrounded from all sides by mixture of charcoal and common salt in alternate layers including protection pipe GI light grade 40mm bore by means of bolts, nuts, check nuts and washers including necessary excavation and earth work, provision of PCC chambers in PCC 1:3:6 type C-2 with RCC cover, funnel with wiremesh 20mm dia medium grade GI pipe for watering complete including testing on completeion as per Electrical plate no. 3 of SSR Part-1 complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion including demolition of old earthing all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.
M L TREATMENTS
DEE PEE ENTERPRISE
SANDIP BARUAH
Yaduvanshi Traders
VENUS TRADING CORPORATION
Goswami Traders
M/S MANOJ PAUL
Rana Kr Phookan
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .