Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | Ist₹6.4 LAccepted-Finance 19 A DURGA BARI SADAR BAZAR MEERUT MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | Ist | Accepted-Finance L-1 Bidder | |
| 2 | IInd₹7.0 LRejected-Finance 16F 1K NEW MARKET BAMRAULI NEAR BAMRAULI RAILWAY STATION ALLAHABAD UTTAR PRADESH 211012 | PRAYAGRAJ | UTTAR PRADESH | 211012 | IInd | Rejected-Finance L-2 Bidder | |
| 3 | IIIrd₹7.6 LRejected-Finance | IIIrd | Rejected-Finance L-3 Bidder | |
| 4 | IVth₹11.4 LRejected-Finance | IVth | Rejected-Finance L-4 Bidder |
| Sl No | Description | Qty | Unit | Technocrat Electrical L1 | R.S.ASSOCIATE L2 | M/s S.S. Refregeration L3 | Gupta Elect and Engg Works L4 |
|---|---|---|---|---|---|---|---|
| 1.01AT 132 KV S/S MANDUADIH | |||||||
| 1.02Following works to be carried out for replacement of T/F main tank gaskets including other associated work for 132/33 KV ,40 MVA T/F-III (M/S AREVA Make,Mfg-2006),40 MVA T/F-IV (EMCO Make ,Mfg-2010) at 132 KV S/S Manduadih under ETD-I, Varanasi with all cost of man, materials, T&P as per technical specification of the work with the safety and precautions as per directions of supervising Engineer. | |||||||
| 1.03 | Safe transportation of Empty oil tank 20 KL capacity from 220 KV S/S Gajokhar to 132 KV S/S Manduadih distance approx-60 Kms. This work includes safe shifting and loading of oil tank with the help of Hydra/Crane and safe unloading at working site at 132 KV S/S Manduadih. | 1 | Job | 10,000 ₹10,000 Lowest | 12,600 ₹12,600 | 15,000 ₹15,000 | 19,500 ₹19,500 |
| 1.04 | Opening of Jumpers of jumpers of HV/LV side bushing and removal of earthing strip from neutral bushing. | 2 | Job | 2,000 ₹4,000 | 840 ₹1,680 Lowest | 2,000 ₹4,000 | 5,000 ₹10,000 |
| 1.05 | Dismantling of 40 MVA transformer accessories including radiator, bushing, buchholz relay, oil pipe line from conservator tank to main tank. Oil pipe lie to OLTC and surge relay coservator tank. | 2 | Job | 25,000 ₹50,000 | 25,200 ₹50,400 | 10,000 ₹20,000 Lowest | 38,000 ₹76,000 |
| 1.06 | Complete drain out of transformer oil from the existing 40 MVA T/F into empty oil tank(20KL)/Drum.This work also include cleaning of core and winding by transformer oil and removal of sludge from bottem of main tank. | 2 | Job | 2,000 ₹4,000 Lowest | 16,800 ₹33,600 | 2,000 ₹4,000 Lowest | 15,000 ₹30,000 |
| 1.07 | Creating vaccum inside the main tank for period for 12Hrs and filling of centrifuging oil top up to core, core ,tank, radiator and winding conservator new transformer oil in | 2 | Job | 1,000 ₹2,000 | 420 ₹840 Lowest | 10,000 ₹20,000 | 15,000 ₹30,000 |
| 1.08 | Replacement of all gaskets including top cover of transformer by providing and fixing of new gaskets as per existing size made of Rubberized cork sheet Konika/Turboze/Nucork brand grade 07. | 2 | Job | 65,000 ₹1,30,000 | 58,800 ₹1,17,600 Lowest | 95,000 ₹1,90,000 | 1,10,000 ₹2,20,000 |
| 1.09 | Creating vaccum inside the main tank for period for 12Hrs and filling of centrifuged new transformer oil in main tank of required BDV after prepration in 20 KL oil tanker. | 2 | Job | 1,000 ₹2,000 Lowest | 8,400 ₹16,800 | 10,000 ₹20,000 | 15,000 ₹30,000 |
| 1.10 | Complete erection of 40 MVA Transformer including radiator, conservator tank, HV/LV and Neutral bushing connecting oil pipe line. Erection of cooling fans making control cable connection, Buchholz relay etc. topping up of transformer oil and final oil filling in the tank, radiator, conservator tank all other accessories. | 2 | Job | 25,000 ₹50,000 Lowest | 42,000 ₹84,000 | 30,000 ₹60,000 | 38,000 ₹76,000 |
Tender Value
₹8.1 L
EMD Value
₹9,000
Closing Date
10 Jul 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, ETC-I, Varanasi
Bhikharipur, DLW, Varanasi
REPLACEMENT OF DAMAGED GASKET OF 40 MVA TRANSFORMER-III (AREVA MAKE), 40 MVA T/F-IV(EMCO MAKE) and 40 MVA T/F-2(BBL MAKE)
2025_UPTCL_1049016_1
E-Tender No. 11/2025-26/ETC-I/VNS
Open Tender
Electrical Works
Item Wise
30 days
132KV S/S Manduadih and 220KV S/S Raja Ka Talab
Fee/EMD/PAN/GST Registration and experience for execution of work as per specification
2 documents required · 2 mandatory
₹590
SE, ETC-VARANASI
₹9,000
8 Dec 2025
16 Jun 2025
11 Jul 2025
16 Jun 2025
10 Jul 2025
1 Jul 2025
Amount
AT 132 KV S/S MANDUADIH
Following works to be carried out for replacement of T/F main tank gaskets including other associated work for 132/33 KV ,40 MVA T/F-III (M/S AREVA Make,Mfg-2006),40 MVA T/F-IV (EMCO Make ,Mfg-2010) at 132 KV S/S Manduadih under ETD-I, Varanasi with all cost of man, materials, T&P as per technical specification of the work with the safety and precautions as per directions of supervising Engineer.
Safe transportation of Empty oil tank 20 KL capacity from 220 KV S/S Gajokhar to 132 KV S/S Manduadih distance approx-60 Kms. This work includes safe shifting and loading of oil tank with the help of Hydra/Crane and safe unloading at working site at 132 KV S/S Manduadih.
Opening of Jumpers of jumpers of HV/LV side bushing and removal of earthing strip from neutral bushing.
Dismantling of 40 MVA transformer accessories including radiator, bushing, buchholz relay, oil pipe line from conservator tank to main tank. Oil pipe lie to OLTC and surge relay coservator tank.
Complete drain out of transformer oil from the existing 40 MVA T/F into empty oil tank(20KL)/Drum.This work also include cleaning of core and winding by transformer oil and removal of sludge from bottem of main tank.
Creating vaccum inside the main tank for period for 12Hrs and filling of centrifuging oil top up to core, core ,tank, radiator and winding conservator new transformer oil in
Replacement of all gaskets including top cover of transformer by providing and fixing of new gaskets as per existing size made of Rubberized cork sheet Konika/Turboze/Nucork brand grade 07.
Creating vaccum inside the main tank for period for 12Hrs and filling of centrifuged new transformer oil in main tank of required BDV after prepration in 20 KL oil tanker.
Complete erection of 40 MVA Transformer including radiator, conservator tank, HV/LV and Neutral bushing connecting oil pipe line. Erection of cooling fans making control cable connection, Buchholz relay etc. topping up of transformer oil and final oil filling in the tank, radiator, conservator tank all other accessories.
Centrifuging of complete transformer oil in transformer tank or oil tanker by connecting centrifuging pipes, circulating the transformer oil through centrifuging machine to be provided by the contractor and taking the BDV value of the oil preiodically till the required value achieved as per direction of supervising engineer and also measurment of PPM. All labour, T&P, Centrifuging machine shall be provided by contractor at his own cost
Spray painting of 132/33 KV 40 MVA T/F-1,II'III & IV with one coats of red oxide and two coats smoke gray paint by good quality Asian make enamel paint after cleaning of rust, dust and oil spots etc.
Collection of oil sample from S/S 15 Days after enerization of T/F and testing and submission of report of oil sample such as BDV,PPM,DGA and Ten delta Flash point etc.
At 220 KV Substation Raja Talab
Following works to be carried out for replacement of T/F main tank gaskets including other associated work for 132/33 KV 40 MVA T/F-2 (BBL Make ,MFG-2007) at 220 KV S/S Raja Talab under ETD-1 Varanasi with all cost of man, materials, T&P as per technical specification of the work with the safety and precautions as per directions of supervising Enginner.
Safe transportation of Empty oil tank 20 KL capacity from 132 KV S/S Manduadih to 220 KV S/S Raja Talab (Thathra) distance approx-40 Kms. This work includes safe shifting and loading of oil tank with the helf of Hydra/Crane and safe unloading at working site at 220 KV S/S Raja Talab.
Opening of Jumpers of jumpers of HV/LV side bushing and removal of earthing strip from neutral bushing
Dismantling of 40 MVA transformer accessories including radiator, bushing, buchholz rela, oil pipe line from conservator tank to main tank. oil pipe lie to OLTC and surge relay coservator tank.
Complete drain out of transformer oil from the existing 40 MVA T/F into empty oil tank(20KL)/Drum. This work also include cleaning of core and winding by transformer oil and removal of sludge from bottem of main tank.
Creating vaccum inside the main tank for period for 12Hrs and filling of centrifuging oil top up to core, core ,tank, radiator and winding conservator new transformer oil in
Replacement of all gaskets including top cover of transformer by providing and fixing of new gaskets as per existing size made of Rubberized cork sheet Konika/ Turboze/ Nucork brand grade 07
Creating vaccum inside the main tank for period for 12Hrs and filling of centrifuged new transformer oil in main tank of required BDV after prepration in 20 KL oil tanker.
Complete erection of 40 MVA Transformer including radiator, conservator tank, HV/LV and Neutral bushing connecting oil pipe line. Erection of cooling fans making control cable connection, Buchholz relay etc. opping up of transformer oil and final oil filling in the tank, radiator, conservator tank all other accessories.
Centrifuging of complete transformer oil in transformer tank or oil tanker by connecting centrifuging pipes, circulating the transformer oil through centrifuging machine to be provided by the contractor and taking the BDV value of the oil preiodically till the required value achieved as per direction of supervising engineer and also measurment of PPM. All labour, T&P, Centrifuging machine shall be provided by contractor at his own cost
Spray painting of 132/33 KV 40 MVA T/F with one coats of red oxide and two coats smoke gray paint by good quality Asian make enamel paint after cleaning of rust, dust and oil spots etc.
Collection of oil sample from S/S 15 Days after enerization of T/F and testing and submission of report of oil sample such as BDV,PPM,DGA and Ten delta Flash point etc.
R.S.ASSOCIATE (BID ID -5310216)
M/s S.S. Refregeration (BID ID -5304901)
Gupta Elect and Engg Works (BID ID -5305823)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .