Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 249 SHALIMAR SHAMLI | SHAMLI | SHAMLI | UTTAR PRADESH | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical 100 FOOTA ROAD FCI COLONY BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
29 Apr 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
office of the S.E., EUDC-II, Sec-18, Noida.
Construction of New 11KV Feeder of village Mahepa for supply to domestic consumers under EDD - Gr
2024_PVVNL_922414_1
Construction of New 11KV Feeder of village Mahepa for supply to domestic consumers under EDD - Gr
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹26,000
16 May 2024
20 Apr 2024
29 Apr 2024
20 Apr 2024
29 Apr 2024
20 Apr 2024
Amount
Construction of New 11KV Feeder of village Mahepa for supply to domestic consumers under EDD - Gr. Noida.
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 14
ST/PCC 11Mtr Pole
PCC 8.5Mtr Pole
11KV XLPE Cable 3x185sqmm
ACSR RABBIT CONDUCTOR
ABC 3X120+1X95+1X16 SQMM CABLE
11KV Pin Insulator with Pin
11KV Disc Insulator with Fittings
11KV X Arm
Stay Set Complete
11KV Dropper and Top Channel 100x50x2240mm
11KV Fuse Set
11KV VCB O/G CTR 400/200/5Amp.
Distribution Box 3 Phase
Heat Shrinkable outdoor type end termination cable jointing kit suitable for 11KV XLPE 3x185 Sq.mm. cable (Make - Raychem/3M/Denson)
Errection of above Following material and Supply and errection of the below material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) ST/PCC - 11Mtr Long Pole and PCC - 8.5 Mtr. Long Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST/PCC - 11Mtr Long Pole and PCC - 8.5 Mtr. Long Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) ST/PCC - 11Mtr Long Pole and PCC - 8.5 Mtr. Long Pole
FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT.
FIXING OF DISC INSULATOR WITH FITTING, COMPLETE WORK IN ALL RESPECT.
FIXING OF 11KV X ARM COMPLETE WORK IN ALL RESPECT.
FIXING OF 11KV FUSE SET COMPLETE WORK IN ALL RESPECT.
FIXING OF 3 PHASE DISTRIBUTION BOX AT SITE WITH COMPLETE WORK IN ALL RESPECT.
FIXING OF TOP and Dropper CHANNEL AS PER SITE REQUIREMENT.
Laying, spreading, lifting and final sagging of 3 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel as per site requirement.
Laying, spreading, lifting and final sagging of ABC 3X120+1X95+1X16 SQMM in accordance with Line chart includidng binding and fixing of all accessories in parallel as per site requirement.
Laying and commissiong of 11KV 3x185sqmm XLPE Cable Double Ckt. after digging trench of dia 220 mm in two parallel bores for Double Curcuit by manual method at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and Providing & Laying of Ist Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, Providing 150 thickness mm River sand for cushion beneath and 150mm above the cable and Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Preparation of 11 KV Power Cable ends: Making of 11 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x185sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
FIXING AND PROPER COMMISSIONING & CONNECTION OF 11KV VCB WITH COMPLETE WORK IN ALL RESPECT INCLUDING PLINTH/FOUNDATION.
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
PROVIDING AND FIXING OF G.I. PIPE 6" Dia for the Pole risers or AS PER REQUIREMENT.
PROVIDING AND FIXING OF CLAMS WITH NUT & BOLT AS PER REQUIREMENT.
PROVIDING AND FIXING OF F-CLAMP AS PER REQUIREMENT.
PROVIDING AND FIXING OF PIERCING CLAMP AS PER REQUIREMENT.
PROVIDING AND FIXING OF DEAD END CLAMP AS PER REQUIREMENT.
PROVIDING AND FIXING OF NUT BOLT AND WASHERSAS PER REQUIREMENT.
Kunal Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .