| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹57.3 LAccepted-AOC 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L-1 | Accepted-AOC Become L1 | |
| 2 | L-2₹58.6 L+₹1.3 L (2.20%)Rejected-AOC FP 38A GROUND FLOOR PITAMPURA NEW DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | L-2 | Rejected-AOC Rejected | |
| 3 | L-3₹58.9 L+₹1.6 L (2.72%)Rejected-AOC | L-3 | Rejected-AOC Rejected | |
| 4 | L-4₹62.7 L+₹5.4 L (9.37%)Rejected-AOC | L-4 | Rejected-AOC Rejected |
Tender Value
₹63.8 L
EMD Value
₹1.3 L
Closing Date
19 Oct 2023, 4:00 pmClosed
Sr. Manager(Engg.-E), CHQ-IMU
Airports Authority of India, IMU, Corporate Head Quarters, Rajiv Gandhi Bhawan, Safdarjung Airport, New Delhi-110003
Augmentation of Internal Electrical Installations at New Office Complex at Safdarjung Airport, New Delhi.
2023_AAI_169161_1
AAI/IMU/SM(E-E)/ENIT03/23-24
Open Tender
Electrical Works
Item Rate
270 days
New Delhi
As per NIT
22 documents required · 22 mandatory
₹1,180
₹1.3 L
10 Apr 2024
29 Sept 2023
20 Oct 2023
29 Sept 2023
19 Oct 2023
29 Sept 2023
29 Sept 2023 - 5 Oct 2023
Amount
Supply of following lighting fixtures suitable for operation at indoor site conditions and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear/ driver including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fasteners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, specifications of this tender and directions of Engineer-in-Charge.
Recess mounted circular downlighter fitting should have nominal system lumen of 1500 lm, CCT of 4000K. The fixture should comply with the parameters as per IS10322, EMC / EMI compliance, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Surface mounted or suspended type 4 feet Batten LED fixture should have nominal system lumen of 4800 lm, CCT of 5700K. The fixture should comply with the parameters as per IS10322, EMC / EMI compliance, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Surface mounted LED 600 x 600 mm fitting should have nominal system lumen of 3000 lm, CCT of 5700K. The fixture should comply with the parameters as per IS10322, EMC / EMI compliance, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Recess mounted LED 600 x 600 mm fitting should have nominal system lumen of 3000 lm, CCT of 5700K. The fixture should comply with the parameters as per IS10322, EMC / EMI compliance, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Surface mounted LED 300 x 300 mm fitting should have nominal system lumen of 1500lm, CCT of 5700K. The fixture should comply with the parameters as per IS10322, EMC / EMI compliance, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Recess mounted LED 300 x 300 mm fitting should have nominal system lumen of 1500lm, CCT of 5700K. The fixture should comply with the parameters as per IS10322, EMC / EMI compliance, and LED driver shall be BIS registered & luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer.
Supply of following PVC sheathed, XLPE insulated, Aluminium conductor armoured cable, 1.1 KV grade, as per IS 7098 (Part 1) 1988 with upto date amendments.
4 Core, 10 sqmm.
4 Core, 16 sqmm.
4 Core, 25 sqmm.
Supply and Installation of DLP plastic U-PVC trunking (Make: Legrand) of following items i/c accessories as required.
Plastic trunking (cat no. 0104 22) without cover 105 mm X 50 mm
Plastic trunking cover (cat no. 0105 22) suitable for 105 mm X 50 mm
Separation (cat no. 0105 82) suitable for trunking size 105mmx50mm
Body joint for aligning bases during installation (cat No. 0106 91) suitable for trunking size 105mmx50mm
Internal Angle adjusted from 800-1000 angle suitable for truncking size 105mm x 50 mm (cat No. 0106 02)
External Angle adjusted from 600-1200 angle suitable for truncking size 105mm x 50 mm (cat No. 0106 22)
Flat Angle - 900 suitable for truncking size 105mm x 50 mm (cat no. 0107 85)
End caps suitable for trunking size 105mmx50mm (cat no. 107 02)
Plastic trunking with cover & without central partition 32 mm X 20 mm (cat no. 0300 17)
End caps suitable for trunking size 32mmx20mm (cat no. 0312 09)
Changeable Flat Angle suitable for trunking size 32mmx20mm (cat no. 0302 73)
Changeable Internal-external Angle suitable for trunking size 32mmx20mm (cat no. 0302 71)
Supply and Installation of Modular base, cover plate & insulation unit DLP trunking (for 85 mm cover) etc. as required. (MAKE: Legrand)
1 or 2 Module (Cat No. 0109 92)
3 Module (Cat No. 0109 93)
4 Module (Cat No. 0109 94)
6 Module (Cat No. 0109 96)
Supply and Installation of Modular switch/socket/accessories on the existing DLP trunking i/c connection but excluding modular plate & cover etc. as required.
01 module telephone jack with shutter -RJ11 (make: Legrand, cat no. 5734 26)
01 module double telephone jack with shutter -Double RJ11 (make: Legrand, cat no. 5734 27)
01 module blanking plate (make: Legrand, cat no. 5734 49)
1 module RJ45 port (Cat 6 UTP) (make: Legrand, cat no. 5734 28)
6 Amp. One way module switch (make: Legrand, Cat no. 5734 00 )
20 Amp. One way module switch (make: Legrand, Cat no. 5734 10 )
25 Amp. One way module switch (make: Legrand, Cat no. 5734 17)
6/16 Amp. Twin socket heavy duty (2 module) (make: Legrand, cat no. 5734 71)
6 Amp. Modular type socket (two module) (make: Legrand, Cat no. 5734 70)
25 Amp. Modular type socket (two module) (make: Legrand, Cat no. 5734 66)
Execution of works as per CPWD, Delhi Schedule of Rate (E&M) 2022 and specification as and when required. Percentage above or below on the rates of DSR (E&M) 2022-(CPWD)-Electrical items worth totalling to Rs. 40,00,000.00 as mentioned below. (Note: Rate shall be quoted in the Indian Rupees only payment of DSR item will be released on the basis of percentage calculation of quoted amount and fixed amount of Rs. 40,00,000/- as clarified below: For Example: If desired to quote 5% above on DSR-2022 rates, the rate column shall be filled as Rs.4,20,000/- If desired to quote 5% below on DSR-2022 rates, the rate column shall be filled as Rs.38,00,000/-) (Rates are inclusive of Cess@1% but excluding GST on Rs.40,00,000/-)
VRISHANK ELECTRICALS
ANAND AND COMPANTY
Trishul Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .