Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹42.5 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹44.1 L+₹1.1 L (2.56%)Rejected-Finance D 2 36 VIBHUTI KHAND GOMATI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226010 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹44.1 L+₹1.1 L (2.65%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹49.5 L+₹6.5 L (15.1%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹54.6 L+₹11.6 L (27.1%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | 5 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | Unnati Engineers L3 | ANKIT SHIP REPAIRERS AND SUPPLIERS L4 | M/S S.B. Singh and Sons L1 | OMVIN ENTERPRISES LLP L5 | Lucknow Refrigeration L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L Point wiring (in repairs) for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed. | 180 | Each Point | 425 ₹76,500 | 550 ₹99,000 | 375 ₹67,500 Lowest | 400 ₹72,000 | 480 ₹86,400 |
| 2.00 | All as per item No 1 here-in-above but for one socket outlet point 5 amps on independent board controlled by one, one way switch. | 38 | Each Point | 455 ₹17,290 | 550 ₹20,900 | 375 ₹14,250 Lowest | 400 ₹15,200 | 530 ₹20,140 |
| 3.00 | All as per item No 1 here-in-above but for one socket outlet point on the same baord with other switches. | 35 | Each Point | 120 ₹4,200 | 100 ₹3,500 | 80 ₹2,800 Lowest | 150 ₹5,250 | 90 ₹3,150 |
| 4.00 | M & L for Point wiring (in repairs) for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed . | 35 | Each Point | 475 ₹16,625 | 650 ₹22,750 | 425 ₹14,875 Lowest | 500 ₹17,500 | 650 ₹22,750 |
| 5.00 | S & F in repairs Switch piano flush type of sigle pole ,5/6 Amps, one way ,complete all as specified and as directed. | 253 | Each | 80 ₹20,240 | 40 ₹10,120 | 19 ₹4,807 Lowest | 20 ₹5,060 | 28 ₹7,084 |
| 6.00 | S & F in repairs Switch piano flush type of single pole, 15 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge. | 35 | Each | 120 ₹4,200 | 85 ₹2,975 | 75 ₹2,625 | 80 ₹2,800 | 38 ₹1,330 Lowest |
| 7.00 | S & F in repairs Socket out let 2 in 1 socket 3 pin 5 Amps, flush type controlled by one switch , complete all as specified and directed. | 73 | Each | 100 ₹7,300 | 45 ₹3,285 | 25 ₹1,825 Lowest | 50 ₹3,650 | 45 ₹3,285 |
| 8.00 | S & F in repairs Socket out let 2 in 1, 3 pin, 5 and 15 Amps flush type , complete all as specified and as directed. | 35 | Each | 120 ₹4,200 | 90 ₹3,150 | 75 ₹2,625 Lowest | 80 ₹2,800 | 90 ₹3,150 |
| 9.00 | S&F in repairs fan regulator electronic, step up socket type, 230 volt and conection complete all as directed. | 14 | Each | 175 ₹2,450 | 160 ₹2,240 Lowest | 290 ₹4,060 | 170 ₹2,380 | 230 ₹3,220 |
| 10.00 | S&F in repairs ceiling rose surface bakelite three terminal complete as directed. | 160 | Each | 40 ₹6,400 | 35 ₹5,600 | 28 ₹4,480 | 24 ₹3,840 Lowest | 28 ₹4,480 |
Tender Value
₹52 L
EMD Value
₹1.0 L
Closing Date
5 Dec 2025, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
REPAIR/REPLACEMENT AND MAINT OF WATER LEVEL INDICATOR, GATE LIGHT, BLDG SECURITY LIGHT AND INTERNAL WIRING INCL TUBE LIGHT FITTINGS AND FIXTURES INCL MCB DBS AND OTHER MISC WORKS AT DIFFERENT PUMP HOUSES IN THE AREA OF AGE E/M EXT (W/S) UNDER GE (E/M
2025_MES_733617_2
CWE/LKO/EM/T-84 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EM LUCKNOW
₹1.0 L
Yes
27 Feb 2026
21 Nov 2025
8 Dec 2025
21 Nov 2025
5 Dec 2025
28 Nov 2025
21 Nov 2025 - 28 Nov 2025
M & L Point wiring (in repairs) for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed.
All as per item No 1 here-in-above but for one socket outlet point 5 amps on independent board controlled by one, one way switch.
All as per item No 1 here-in-above but for one socket outlet point on the same baord with other switches.
M & L for Point wiring (in repairs) for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly including taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately)and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed .
S & F in repairs Switch piano flush type of sigle pole ,5/6 Amps, one way ,complete all as specified and as directed.
S & F in repairs Switch piano flush type of single pole, 15 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
S & F in repairs Socket out let 2 in 1 socket 3 pin 5 Amps, flush type controlled by one switch , complete all as specified and directed.
S & F in repairs Socket out let 2 in 1, 3 pin, 5 and 15 Amps flush type , complete all as specified and as directed.
S&F in repairs fan regulator electronic, step up socket type, 230 volt and conection complete all as directed.
S&F in repairs ceiling rose surface bakelite three terminal complete as directed.
S&F in repairs Lamp Holder PVC/ polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in- Charge.
S&F in repairs sheet metal enclosure for DB’s when MCB, to be used, TPN, 4 ways 415 volt with 200 Amps rated bus bar made out of 16 Gauge sheet steel double door complete all as specified. (MCB required to be fixed shall be paid for separately under respective items of this Schedule ‘A’)
S & F in repairs distribution box epoxy powder coated ,SPN 8 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed.
S & F in repairs distribution box epoxy powder coated ,SPN 4 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door as in replacment ,complete all as specified and directed.
S & F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 amps , complete all as specified and directed.
Supply & fix in repair MCB TPN capacity 32 Amps, 415V, 50 c/s 16 KA, complete all as specified and directed.
Supply & fix in repair MCB SPN capacity 32 amp, 'C' series , complete all as specified and directed.
S & F in repairs MCB SP 6 to 40 Amps, 240 Volts of 'B' series to be housed in DBs and suitable size cable lugs to be fixed with MCBs as in replacment, complete all as specified and directed.
S & F in repairs MCCB 160 Amps, 415 volts AC 50Hz, 4 pole, bracking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
S & F in repairs MCCB 200 Amps, 415 volts AC 50Hz, 4 pole, bracking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
S & F in repairs MCCB 100 Amps, 415 volts AC 50Hz, 3 pole, bracking capacity 16 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
S&F in repairs electronic control timer type ET-100 of suitable capacity as required at site.
Supply & fix in repairs under voltage relay
Supply & fix in repair four Pole Power Contractor -Type MCX-22, 100 Amps, 415V, 50 Hz
Supply & fix in repair three Pole Power Contractor -Type, MNX-95, upto 120 Amps, 415V, 50 Hz
Supply & fix in repair three Pole Power Contractor -Type, MNX-110, 120 Amps, 415V, 50 Hz
Supply & fix in repair three Pole Power Contractor -Type MNX-140, 160 Amps, 415V, 50 Hz,
Supply & fix in repair four/three Pole Power Contractor -Type ML-06 100 Amps, 415V, 50 Hz
Supply & fix in repair Single Phase Preventor Relay + Timer 415 Volt
Supply & fix in repairs outdoor type fountain light waterproof and RGB colour with 6 bulb, 18 watt LED, 12 volt, IP68 with fitting accessories all as specified and directed.
S&F in repair 70 watt LED street light fitting 230 V AC, system lumen efficiency not less than 110 lumen / watt, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply & fixing in repair Gate light LED-40 WATT 215 V, 50 HZ, post top made in cast aluminium spigot housing with decorative clear acrylic diffuser and IP65 protection fix with GI Pipe 40 mm dia 30 cm long (15 cm under the pillar & 15 cm above the pillar ) with proper connecting with existing electric cable in and including taking out old unservicable light , complete all as specified and directed.
Supply and fixing in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repairs PVC insulated & sheathed , heavy duty electric cable on RCC Piller /Dome of over head tank at hight of 26 meter approximatelly from normal ground level including fixing arrangement with Copper conductor, multi stranded 1100 volts grade flat 2 core 04 Sqmm and taking out of existing unserviceable cable complete all as specified and directed.
Suppling, laying, fixing and testing in repairs LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core laid in trenches/ under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing complete and taking out unserviceable cable, complete all as specified and directed. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block shall be measured and paid separately under appropriate items.
All as per Sl No 35 here-in-above but 25 Sqmm 3.5 core.
All as per Sl No 35 here-in-above but 35 Sqmm 3.5 core.
All as per Sl No 35 here-in-above but 50 Sqmm 3.5 core.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed.
Supplying and laying or fixing DWC HDPE pipe alongwith all accessories like socket,bend, couplers etc ISI marked as per IS - 16205 (Part-24) including cutting/jointing laid in trenches,wall,floor etc as required 40 mm outer dia and 32 mm inner dia (for cable protection) complete.
Supplying and laying or fixing DWC HDPE pipe alongwith all accessories like socket,bend, couplers etc ISI marked as per IS - 16205 (Part-24) including cutting/jointing laid in trenches,wall,floor etc as required 50 mm outer dia and 38 mm inner dia (for cable protection) complete.
Supplying and laying or fixing DWC HDPE pipe alongwith all accessories like socket,bend, couplers etc ISI marked as per IS - 16205 (Part-24) including cutting/jointing laid in trenches,wall,floor etc as required 77 mm outer dia and 63 mm inner dia (for cable protection) complete.
Supply & fixing on load Changeover switch in open execution 4 pole 415 V, 50 cycles-100 Amp complete all as specified and directed.
Supply & fixing in replacement of DOL starter for single phase motor, 220 V upto 3 HP Motor complete all as specified and directed.
Supply & fixing in replacement of DOL starter for three phase motor,440 V 5 HP Motor complete all as specified and directed.
Supply & fixing in replacement of FASD starter for three phase motor,440 V, for upto 20 HP Motor complete all as specified and directed.
Outgoing (a) MCCB 63 Amps, 4 pole,415V, 25 KA adjustable type-02 Nos (b) MCB 20 Amps , SPN – 01 Nos (c) MCB SP 10 Amps-02 Nos (d) MCB TPN 40 Amps- 01 nos (e) Contactor 50 A MNX type - 06 (f) NO-NC push button for 30 hp motor - 04 Nos (g) Timer for star delta starter for 30 hp motor - 02 Nos (h) Phase preventor - 02 Nos (i) Thermal overload relay 45 to 80 A - 02 Nos (j) Timer for security light - 01 Nos (h) phase sequencer three phase of suitable size - 01 nos Note (1):- Cost of foundation is deemed to be included in the unit rate and foundation is made as per manufacture design.
Each Job
The panel shall be dust and vermin proof, indoor type made of 2 MM CRCA MS sheet, powder coated finish over one coat of red oxide primer outside and two coats of red o
xide primer on inside, front opening type, with aprons for cable entry, and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sqmm.
Motor Protection features: • Motor overload, Excess start time(stall), Undercurrent, Instantaneous overcurrent • Phase loss, Phase Sequence, Undervoltage, Overvoltage, Motor Connection fault • Current imbalance, External trip (x2), Motor thermistor, Shorted SCR, Power loss • Supply frequency, Network communications, Heatsink over-temperature • Batter/clock failure, Bypass overload, Control supply ANCILLARY FUNCTIONS: • Jog, Emergency Mode, Dual Motor Sets, Inside Delta Operation, • Motor Reverse Control, Restart Delay: Anti-backspin • Power-Through Mode, Second Motor Set, Auto Reset • Pump Clean, Run Timers, Weekly Scheduling • Auto-Start/Stop Soft Brake Control Simulation Tools Semiconductor Fuse • Type-2 Coordination with semiconductor fuses should be followed, Bussman 170M3013 or Suitable rating semiconductor fuse along with mounting mechanism for soft starter should be used.
Supplying, laying or fixing, jointing and testing solid PVC insulated , 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 Volts garde 0.5 sqmm instruemental cable ISI-5608 marked ,complete all as specified laid in trenches/ laid under floor including taking out unserviceable cable complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items.
Supplying, laying or fixing, jointing and testing solid PVC insulated , 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 Volts grade 0.5 sqmm instruemental cable ISI-5608 marked , fixed on walls, including taking out unserviceable cable complete all as specified and directed.
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of GI strip of size 32x6mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 40mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed.
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00mm by me
ans of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 40mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed.
Note(2) :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. (iv) Design/Drawindg Shall be approved by GE. (v) Wiring diagram of Panel should be embosed on the panel by manufacturer in mettalic sheet.
Each Job
M & L for Wash out complete water by pumping set/manually of existing Underground sump/ static water tank up to 400000 gallons capacity including removing deposited sand from inside the tank, scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits stains using wire brush, filling of cavaties inside of tank with CM 1:1 with quick setting cement and applying two coat of white wash inside & writing date of cleaning complete all as specified and directed. Note:-1. All type of T & P, Labour & pumping set etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. 2. Contractor will dispose off the material taken out from the sump at a distance upto 50 Mtr as ddirected by Engieneer-in-Charge. 3. Contractor will clean the surroundings of Tank upto 3 mtr around the plinth of the tank.
M & L for Cleaning inside RCC OH reservoirs capacity 375000 gallons at 22 metre staging including removing deposit sand from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus deposits starins using wire brush filling of cavaties inside of tank with cm 1:1with quick cement and applying one coat of white wash inside including dome & writing date of cleaning complete all as specified and directed including repair to wash out system if required for proper flushing of over head tank. Note :-1. All type of T&P and Labour etc shall be arranged by the contractor and rate for the same will be deemed to be included in the quoted rate. 2. Contractor will dispose off the material taken out from the Tank at a distance upto 50 Mtr as directed by Engieneer-in-Charge. 3. Contractor will clean the surroundings of Tank upto 5 mtr around from the plinth of the tank.
All as per item No 60 above but tank capacity 100000 gallons complete all as specified and directed.
M&L for Painting of pipe lines with two coat of synthetic enamell paint as per colour code after cleaning and removing existing dust and dirt on existing painted surfaces complete all as specified and directed of undermentioned sizes:- Note:- The rate for scafolding etc deemed to be included in the quoted rates.
a) 200 mm bore vertical with over head tanks from GL upto 21 Mtr above GL
b)150/100mm bore vertical with over head tanks from GL upto 21 Mtr above GL
c) 150/200 mm bore horizontal/vertical pipe along with Sluice valve/ NRV at GL for header/inside/Outside of Pump House
d) 100/80 mm bore horizontal/vertical pipe along with Sluice valve/ NRV at GL for header/inside/Outside of Pump House
Supply, Installation,(in replacement) testing and commissioning of outdoor type wall mounted water level indicator panel having environmental protection IP-67. Panel consisting of 05 nos. water levels for direct contact type point level sensors along with alarm annunciation for complete empty or complete full of OHT or UG sump. Also, panel consist of SMPS, Power ON (Green) LED lamp, MCB with proper ferruling & wiring etc.
Supply, Installation,(in replacement) testing and commissioning of nonrusting type Teflon coated magnetic float point level sensor having wire length 5 meter minimum complete all as specified & directed .
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
2ndCallTenderEMT84.pdf
Tender Documents • 0.50 MB
BOQ_829806.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .