Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.2 LAdmitted-Finance | -1.80% | ₹11.2 L | L1 | Admitted-Finance |
| 2 | L2₹11.5 LAdmitted-Finance 53 VAISHAILI ENCLAVE SECTOR 9 INDIRA NAGAR LUCKNOW | LUCKNOW | +0.67% | ₹11.5 L | L2 | Admitted-Finance |
Tender Value
₹11.4 L
EMD Value
₹1.1 L
Closing Date
2 May 2026, 12:00 pmClosed
SE 47th E/M Circle P.W.D. Moradabad
Office of the SE 47th E/M Circle P.W.D. Moradabad
Janpad Muradabad esthit court campus me fire fighting evam fire alarm system se sambandhit marramt karya
2026_CEEMP_1139592_2
460/3WE(MBD)-47/2026 Dt. 09.04.2026
Open Tender
Electrical Works
Percentage
180 days
Moradabad
As per NIT
2 documents required · 2 mandatory
₹854
Executive Engineer E/M Div P.W.D. Moradabad
₹1.1 L
As per NIT
4 Jun 2026
23 Apr 2026
2 May 2026
23 Apr 2026
2 May 2026
23 Apr 2026
24 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive repair and maintenance / major Overhauling of Diesel Engine Pump Set (2280 LPM): Full servicing of 60 HF engine; replacement of Mobil oil (specifiec grade), air/fuel/oil filters; replacement of 12V/24V heavy-duty battery (Exide/ Amaron); radiator flushing and coolant replacement; testing of self-starter and charging alternator etc or inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Nos | - | - |
| 2 | Comprehensive repair and maintenance of Main Electric Fire Pump (60 HP): replacement of heavy-duty ball bearings (SKF/FAG); replacement of mechanical seal/gland packing; greasing and coupling bush replacement /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Nos | - | - |
| 3 | Comprehensive repair and maintenance of Jockey Pump (15 HP): Rewindinq of motor with 'F' class copper insulation; replacement of bearings ano mechanical seal; shaft trueing and dynamic balancing of impeller /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Nos | - | - |
| 4 | Comprehensive repair and maintenance of Terrace Pumps (7.5 HP): General servicing of 2 Nos pumps; replacement of grease, oil seals, and testing of automatic float switches /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 2 | Nos | - | - |
| 5 | Comprehensive repair and maintenance of RRL Hose Pipes (Type-A): 15m length, 63mm dia Reinforced Rubber Lined (RRL) as per IS:636 (Type A) with Gunmetal/SS couplings securely bound with copper wire /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 16 | Nos | - | - |
| 6 | Comprehensive repair and maintenance of SS Branch Pipes: Stainless Steel (Grade 304) short branch pipe with 20mm nozzle. PWD approved design/inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 15 | Nos | - | - |
| 7 | Comprehensive repair and maintenance of Main Control Panel: Replacement of faulty contactors (L&T/ Schneider), Ammeters, Voltmeters, and faulty LED indicators; recalibration of Single Phase Preventer (SPP) and Star-Delta Starters /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | nos | - | - |
| 8 | Comprehensive repair and maintenance of First-Aid Hose Reel of 30m braided hose (if cracked); nozzle cleaning and lubrication of the swinging hub to ensure 180° rotation /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 5 | nos | - | - |
| 9 | Comprehensive repair and maintenance of Fire Alarm System Restoration faulty Smoke/Heat detectors; checking of end-of-line (EOL) resistors; battery backup replacement for the main Fire Alarm Control Panel (FACP) including Comprehensive servicing of the main Power Amplifier and Pre-amplifier unit Includes replacement of faulty internal circuits, cooling fans, fuse assemblies, and calibration of the Master Controller Ensuring integration with the Fire Alarm Panel /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Job | - | - |
| 10 | Comprehensive repair and maintenance of Tank Hygiene & Pipeline Protection: De-silting and high-pressure cleaning of 1.0 Lakh Liter UG tank; application of two coats of anti-corrosive svnthetic enamel paint (Post Office Red) on all exposed MS piping /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.40 MB
BOQ_2127844.xls
BOQ • 0.40 MB
T-1FF.pdf
Tender Documents • 7.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].