Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.2 LAdmitted-Finance | -1.80% | ₹11.2 L | L1 | Admitted-Finance |
| 2 | L2₹11.5 LAdmitted-Finance 53 VAISHAILI ENCLAVE SECTOR 9 INDIRA NAGAR LUCKNOW | LUCKNOW | +0.67% | ₹11.5 L | L2 | Admitted-Finance |
Tender Value
₹11.4 L
EMD Value
₹1.1 L
Closing Date
2 May 2026, 12:00 pmClosed
SE 47th E/M Circle P.W.D. Moradabad
Office of the SE 47th E/M Circle P.W.D. Moradabad
Janpad Muradabad esthit court campus me fire fighting evam fire alarm system se sambandhit marramt karya
2026_CEEMP_1139592_2
460/3WE(MBD)-47/2026 Dt. 09.04.2026
Open Tender
Electrical Works
180 days
Moradabad
As per NIT
2 documents required · 2 mandatory
₹854
Executive Engineer E/M Div P.W.D. Moradabad
₹1.1 L
As per NIT
4 Jun 2026
23 Apr 2026
2 May 2026
23 Apr 2026
2 May 2026
23 Apr 2026
24 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Comprehensive repair and maintenance / major Overhauling of Diesel Engine Pump Set (2280 LPM): Full servicing of 60 HF engine; replacement of Mobil oil (specifiec grade), air/fuel/oil filters; replacement of 12V/24V heavy-duty battery (Exide/ Amaron); radiator flushing and coolant replacement; testing of self-starter and charging alternator etc or inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Nos | - | - | BI01010001010000000000000515BI0100001128 |
| 2 | Comprehensive repair and maintenance of Main Electric Fire Pump (60 HP): replacement of heavy-duty ball bearings (SKF/FAG); replacement of mechanical seal/gland packing; greasing and coupling bush replacement /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Nos | - | - | BI01010001010000000000000515BI0100001129 |
| 3 | Comprehensive repair and maintenance of Jockey Pump (15 HP): Rewindinq of motor with 'F' class copper insulation; replacement of bearings ano mechanical seal; shaft trueing and dynamic balancing of impeller /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Nos | - | - | BI01010001010000000000000515BI0100001130 |
| 4 | Comprehensive repair and maintenance of Terrace Pumps (7.5 HP): General servicing of 2 Nos pumps; replacement of grease, oil seals, and testing of automatic float switches /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 2 | Nos | - | - | BI01010001010000000000000515BI0100001131 |
| 5 | Comprehensive repair and maintenance of RRL Hose Pipes (Type-A): 15m length, 63mm dia Reinforced Rubber Lined (RRL) as per IS:636 (Type A) with Gunmetal/SS couplings securely bound with copper wire /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 16 | Nos | - | - | BI01010001010000000000000515BI0100001132 |
| 6 | Comprehensive repair and maintenance of SS Branch Pipes: Stainless Steel (Grade 304) short branch pipe with 20mm nozzle. PWD approved design/inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 15 | Nos | - | - | BI01010001010000000000000515BI0100001133 |
| 7 | Comprehensive repair and maintenance of Main Control Panel: Replacement of faulty contactors (L&T/ Schneider), Ammeters, Voltmeters, and faulty LED indicators; recalibration of Single Phase Preventer (SPP) and Star-Delta Starters /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | nos | - | - | BI01010001010000000000000515BI0100001134 |
| 8 | Comprehensive repair and maintenance of First-Aid Hose Reel of 30m braided hose (if cracked); nozzle cleaning and lubrication of the swinging hub to ensure 180° rotation /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 5 | nos | - | - | BI01010001010000000000000515BI0100001135 |
| 9 | Comprehensive repair and maintenance of Fire Alarm System Restoration faulty Smoke/Heat detectors; checking of end-of-line (EOL) resistors; battery backup replacement for the main Fire Alarm Control Panel (FACP) including Comprehensive servicing of the main Power Amplifier and Pre-amplifier unit Includes replacement of faulty internal circuits, cooling fans, fuse assemblies, and calibration of the Master Controller Ensuring integration with the Fire Alarm Panel /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | Job | - | - | BI01010001010000000000000515BI0100001136 |
| 10 | Comprehensive repair and maintenance of Tank Hygiene & Pipeline Protection: De-silting and high-pressure cleaning of 1.0 Lakh Liter UG tank; application of two coats of anti-corrosive svnthetic enamel paint (Post Office Red) on all exposed MS piping /inculding changing of above required parts etc complete in all respect or as required as per actual site requirement. | 1 | nos | - | - | BI01010001010000000000000515BI0100001137 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.40 MB
BOQ_2127844.xls
BOQ • 0.40 MB
T-1FF.pdf
Tender Documents • 7.11 MB
Download all tender documents and submit your bid