Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.8 L+₹1.8 L (11.2%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹18.9 L+₹3.0 L (18.5%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹19.0 L+₹3.0 L (18.9%)Rejected-AOC SHANTINAGAR 670 1 AIRPORT HIGHWAY ROAD VASCO DA GAMA 403802 INDIA | SOUTH GOA | GOA | 403802 | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹39,820
Closing Date
8 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOMANTAK VASCO
GE Gomantak Vasco Goa 403802
Repair maint of lighting protection system and other misc EM works at NOFRA NAD and MO Goa under GE Gomantak Vasco
2020_MES_394460_1
8218/E8
Open Tender
Support/Maintenance Service
Works
180 days
VASCO DA GAMA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹39,820
Yes
16 Nov 2021
11 Nov 2020
9 Dec 2020
11 Nov 2020
8 Dec 2020
21 Nov 2020
60 days
Amount
M&L for provn of chemical earthing, electrode made of copper molecular bonded steel rod 17.2 x 3000mm, minimum 254 micron coating, 3 mtr long with connecting strip head with SS fastener, inspection joint box and also connect copper strip with electrode rod and inspection joint box with nut, bolts and GI washers etc . The electrodes will be filled with highly conductive non-corrosive crystalline conductive mixture with connective arrangement for connection of strip/cable etc. The electrode will be installed along with conductive and low resistance powder tested to the resistivity of 0.2 ohms as per IEC 62561-7 read with ASTM G57-06, CI 3.4 connected to copper strip by means of nut bolts check nuts and washer of GI or steel including necessary drilling in earth upto 3 mtr in any type of soil for inserting electrode in any type of strata, Heavy duty poly plastic chamber with cover all as directed by Engr-in-Charge.
Supply and fixing Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm copper strip as per directed by Engr-in-Charge.
M&L for test point terminal block made out of gun metal 75 mm x 75 mm x 25 mm drilled and screwed including three Nos 8mm dia 25 mm long hexagonal head screws and including provision of suitable MS box made out of 3 mm thick MS sheet to accommodate the terminal block all as specified and directed by Engr-in-Charge.
M&L for laying GI pipe 40mm dia light grade for the protection of copper strip.
M&L for PCC 1:3:6, type C-1, using 20mm graded aggregate for repair of damaged plinth protection including necessary form work as per site and directed by Engr-in-Charge.
Supply & fixing aluminium strip 25 x 3 mm fixing on porcelain insulator for roof conductors and down conductors above ground level as lighting conductor (including insulater) complete including removal of old unserviceable earth strip.
Supply and fixing Air termination, single pointed Copper Rod 12mm dia and 300 mm long as specified and directed by Engr-in-Charge.
Supply and filling of chemical earthing compound for enhancement of ground in existing earthpit complete all as specified and directed.
Dismantling the unserviceable electric motor any type or of any capacity and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enamelled copper winding wire of existing gauge and size with insulating materials, varnishing and baking etc, re-fixing the same at site and re-alignment, testing and commissioning complete all as directed by Engr-in-Charge
Taking out old and supply & fixing new PVC fills of cooling tower of any capacity AC plant and replacing with new one including setting complete.
Supply and fixing in repairs ball / roller bearing for pumps and motors of following capacity including taking down old bearing and re installation at site including testing on completion.
(a) 03/05 HP capacity
(b) 10 HP capacity
Supply & fixing of Centrifugal monoblock type pump Sets of 2HP capacity for transferring water having a minimum flow rate capacity not less than 7.5 LPS at not less than 12 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having outlet 50mm dia complete and removal of old one and depositing to MES store all as specified and directed.
Supply & fixing of Centrifugal monoblock type pump Sets of 3HP capacity for transferring water having a minimum flow rate capacity not less than 9.2 LPS at not less than16 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having outlet 50mm dia complete and removal of old one and depositing to MES store all as specified and directed.
Supply & fixing of Centrifugal monoblock type pump Sets of 5HP capacity for transferring water having a minimum flow rate capacity not less than 17.9 LPS at not less than16 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having outlet 65mm dia complete and removal of old one and depositing to MES store all as specified and directed.
Supply & fixing of Centrifugal monoblock type pump Sets of 7.5HP capacity for transferring water having a minimum flow rate capacity not less than 8.6 LPS at not less than 32 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having outlet 65mm dia complete and removal of old one and depositing to MES store all as specified and directed.
Supply & fixing of Centrifugal monoblock type pump Sets of 10HP capacity for transferring water having a minimum flow rate capacity not less than 12.5 LPS at not less than 28 m Head electrically driven and working on 415 V 3 Phase 50 Hz AC supply with CI body bronze impeller having outlet 65mm dia complete and removal of old one and depositing to MES store all as specified and directed.
Supply and fixing power contractor assembly for upto 10 HP motor/pump complete as per existing type and make including taking down old contactor
Supply and fixing Thermal Overload relay range 9 - 12.5 amps as per existing make suitable for upto 10 HP motor/pump complete.
Supply and fixing electronic timer for star delta function having time range 1 - 20 sec, input voltage 380-440V AC or as per existing make and model including taking down of old one.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth and getting out in hard/dense soil for laying and taking down UG cable any size.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 in depth and getting out in soft disintegrated rock for laying and taking down UG cable of any size
M&L for fine river sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment
Supply and laying PCC cable cover class LV type I flat size 250mm x150mmx40mm.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr-in-charge.
Supply & fixing UG LT cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandarded including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall including dismentling of existing cable of 240 Sqmm 3.5 Core.
Supply & fixing MCCB 250 Amps, 25kA, 4 pole, 415 Volts, 50 Hz including dismantling old one.
Supply & fixing MCCB 160 Amps, 25kA, 4 pole, 415 Volts, 50 Hz including dismantling old one.
M&L for earthing complete with copper plate earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to Copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of brass and earth lead connected to terminal box with including necessary earth work and excavation including PCC chamber made up of 1:3:6 and GI cover all as specified and shown in electric plate No 3 of SSR-Part I complete all as specified and directed by Engr-in-Charge.
Inspection of lift by lift inspector authorised by the Goa State Govt as directed by Engineer-in-Charge
Prabha Electricals and Communications
Star Freeze Service
M/s Ekta Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .