| # | Company | Amount |
|---|---|---|
| 1 | ₹100 C 119 S2 SECOND FLOOR RAMPRASTHA COLONY GHAZIABAD U P 201011 | ₹100 |
Tender Value
₹10.0 Cr
EMD Value
₹10.0 L
Closing Date
8 Apr 2022, 11:00 amClosed
Construction of different RKVY Units Poly houses compost unit Development of tissue culture lab vehicle parking and training hall hybridization facility and other miscellaneous farm External Development works for RLBCAU Jhansi, UP
NBCC/SBGDelhill/RLBCAUJhnasi/RKVY/2022/56dated25032022
NBCC/SBGDelhill/RLBCAUJhnasi/RKVY/2022/56dated25032022
Open Tender-Domestic
Civil Works General
Jhansi, Uttar Pradesh
₹11,800
₹10.0 L
24 Jul 2026
25 Mar 2022
8 Apr 2022
8 Apr 2022
19 Apr 2022
Bill of Quantity
Sl No. DSR2021 Description of Items unit Quantity Rate DSR Non DSR
1 1.1.2.2 Carriage of Earth By Mechanical Transport including loading,unloading cum 7875.00 203.98 16,06,342.50
and stacking upto 2km
2 2.6.1 Earth work in excavation by mechanical means (Hydraulic cum 13308.45 205.45 27,34,221.39
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in
width as well as 10 sqm on plan) including getting out and disposal of
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by
Engineer-in-charge.
All Kind of Soil
3 2.7.3 Earth work in excavation by mechanical means (Hydraulic excavator)/ cum 122.89 1,184.30 1,45,537.27
manual means over areas (exceeding 30 cm in depth, 1.5 m in width as
well as 10 sqm on plan) including getting out and disposal of excavated
earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-
Hard rock (blasting prohibited)
4 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, cum 1723.08 253.95 4,37,577.13
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.
5 2.31 Clearing jungle including uprooting of rank vegetation, grass, brush sqm 16135.00 14.50 2,33,957.50
wood, trees and saplings of girth up to 30 cm measured at a height of 1 m
above ground level and removal of rubbish up to a distance of 50 m
outside the periphery of the area cleared.
6 2.28.1 Surface dressing of the ground including removing vegetation and sqm 1001.80 28.15 28,200.67
inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to
50 m and lift up to 1.5 m.
All kinds of soil
7 4.1.8 Providing and laying in position cement concrete of specified grade cum 613.56 6,326.05 38,81,407.13
excluding the cost of centering and shuttering -
All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40
mm nominal size)
8 4.1.2 Providing and laying in position cement concrete of specified grade cum 264.79 7,783.65 20,61,032.68
excluding the cost of centering and shuttering - All work up to plinth level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone
aggregate 20 mm nominal size)
9 5.9.1 Centering and shuttering including strutting, propping etc. and removal of sqm 5819.33 307.95 17,92,061.44
Foundations, footings, bases of columns, etc. for mass concrete
10 5.9.2 Centering and shuttering including strutting, propping etc. and removal of sqm 760.08 669.55 5,08,911.56
Walls (any thickness) including attached pilasters, butteresses,
plinth and string courses etc.
11 5.9.3 Centering and shuttering including strutting, propping etc. and removal of sqm 1290.00 766.55 9,88,849.50
Suspended floors, roofs, landings, balconies and access platform
12 5.9.5 Centering and shuttering including strutting, propping etc. and removal of sqm 280.80 608.35 1,70,824.68
Lintels, beams, plinth beams, girders, bressumers and cantilevers
13 5.9.6 Centering and shuttering including strutting, propping etc. and removal of sqm 388.20 804.25 3,12,209.85
Columns, Pillars, Piers, Abutments, Posts and Struts
14 5.22.6 Steel reinforcement for R.C.C. work including straightening, cutting, kg 41043.64 89.65 36,79,562.33
bending, placing in position and binding all complete upto plinth level .
Thermo-Mechanically Treated bars of grade Fe-500D or more.
15 5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, kg 41649.68 89.65 37,33,894.17
bending, placing in position and binding all complete above plinth level .
Thermo-Mechanically Treated bars of grade Fe-500D or more.
16 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cum 410.44 7,997.30 32,82,383.02
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting
of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following
grades of concrete.
All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Note: Extra cement up to 10% of the minimum specified cement content
in design mix shall be payable separately. In case the cement content
in design mix is more than 110% of the specified minimum cement
content, the contractor shall have discretion to either re-design the mix
or bear the cost of extra cement.
17 5.33.2.1 Providing and laying in position ready mixed or site batched design mix cum 347.08 10,080.15 34,98,625.52
cement concrete for reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from natural sources, Portland
Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting
of concrete, to improve durability and workability without impairing
strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following
grades of concrete.
All works upto plinth level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Note: Extra cement up to 10% of the minimum specified cement content
in design mix shall be payable separately. In case the cement content
in design mix is more than 110% of the specified minimum cement
content, the contractor shall have discretion to either re-design the mix
or bear the cost of extra cement.
18 5.35 Add for using extra cement in the items of design mix over and above quintal 25.00 688.45 17,209.92
the specified cement content therein.
19 6.1.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class cum 241.08 6,658.25 16,05,175.10
designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
20 6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class cum 497.14 8,288.35 41,20,486.90
designation 7.5 in superstructure above plinth level up to floor V level in
all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
21 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks sqm 271.00 1,018.05 2,75,892.36
of class designation 7.5 in superstructure above plinth level up to floor
Cement mortar 1:4 (1 cement :4 coarse sand)
22 7.1.1 Random rubble masonry with hard stone in foundation and plinth cum 30.00 6,653.45 1,99,603.50
including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse
sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level
Cement mortar 1:6 (1 cement : 6 coarse sand)
23 7.2.1 Random rubble masonry with hard stone in superstructure above plinth cum 93.75 8,275.70 7,75,846.88
level and upto floor five level, including leveling up with cement concrete
1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm
nominal size) at window sills, ceiling level and the like.
Cement mortar 1:6 (1 cement : 6 coarse sand)
24 9.1.1 Providing wood work in frames of doors, windows, clerestory windows cum 1.56 1,31,576.95 2,05,260.04
and other frames, wrought framed and fixed in position with hold fast
lugs or with dash fasteners of required dia & length (hold fast lugs or
dash fastener shall be paid for separately).
Second class teak wood
25 13.106 Painting (one or more coats) with black Japan paint of approved sqm 19.50 78.60 1,532.70
brand and manufacture to give an even shade.
26 9.21.1 Providing and fixing ISI marked flush door shutters conforming to IS : sqm 63.00 2,015.75 1,26,992.25
2202 (Part I) non-decorative type, core of block board construction with
frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on both
faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
27 9.127.2 Providing & Fixing decorative high pressure laminated sheet of plain / sqm 126.00 764.00 96,264.00
wood grain in gloss / matt/ suede finish with high density protective
surface layer and reverse side of adhesive bonding quality conforming
to IS : 2046 Type S, including cost of adhesive of approved quality.
28 9.40.1.2 Providing and fixing wooden moulded beading to door and window frames metre 156.00 239.20 37,315.20
with iron screws, plugs and priming coat on unexposed surface etc.
2nd class teak wood
29 9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to each 60.00 194.35 11,661.00
frame with 10 mm diameter bolts, nuts and wooden plugs and embedding
in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse
sand : 6 graded stone aggregate 20mm nominal size).
30 10.27.3 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) each 60.00 144.60 8,676.00
dash fastener of 10 mm dia double threaded 6.8 grade (yield strength
480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide
PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry,
etc. as per direction of Engineer-in-charge.
31 9.82 Providing and fixing bright finished brass hanging type floor door stopper each 30.00 109.60 3,288.00
with necessary screws, etc. complete.
32 9.84 Providing and fixing aluminium extruded section body tubular type each 30.00 856.30 25,689.00
universal hydraulic door closer (having brand logo with ISi, IS : 3564,
embossed on the body, door weight upto 36 kg to 80 kg and door width
from 701 mm to 1000 mm), with double speed adjustment with necessary
accessories and screws etc. complete.
33 9.62.1 Providing and fixing ISI marked oxidised M.S. sliding door bolts with each 30.00 180.55 5,416.50
nuts and screws etc. complete :
34 9.63.1 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, each 30.00 74.65 2,239.50
(Barrel type) with necessary screws etc. complete :
35 9.59.1 Providing and fixing ISI marked oxidised M.S. single acting spring hinges each 30.00 251.70 7,551.00
with necessary screws etc. complete :
36 9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows kg 900.00 181.00 1,62,900.00
etc. with M.S. flats, square or round bars etc. including priming coat
with approved steel primer all complete.
Fixed to steel windows by welding
37 21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators kg 240.00 466.30 1,11,912.00
and partitions with extruded built up standard tubular sections/
appropriate Z sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with dash fasteners of
required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing / paneling, C.P.
brass / stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge. (Glazing, paneling
and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50
38 21.1.2.2 For shutters of doors, windows & ventilators including kg 360.00 564.80 2,03,328.00
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost
of EPDM rubber / neoprene gasket required (Fittings
shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50
39 21.3.2 Providing and fixing glazing in aluminium door, window, ventilator sqm 180.00 1,325.55 2,38,599.00
shutters and partitions etc. with EPDM rubber / neoprene gasket
etc. complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid
in basic item):
With float glass panes of 5 mm thickness (weight not
less than 12.50 kg/sqm)
40 21.8.1 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ metre 180.00 85.25 15,345.00
Stone work by providing weather silicon sealant over backer rod of
approved quality as per architectural drawings and direction of
Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
41 21.15.2 Providing and fixing aluminium casement windows fastener of required each 60.00 79.75 4,785.00
length for aluminium windows with necessary screws etc. complete.
Powder coated minimum thickness 50 micron aluminium
42 9.135.2 Providing and fixing fly proof stainless steel grade 304 wire gauge, to sqm 120.00 1,051.75 1,26,210.00
windows and clerestory windows using wire gauge with average width of
aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
With 12 mm mild steel U beading
43 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow kg 250 612.25 1,53,062.50
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners , stainless
steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-incharge, (for
payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners
44 10.16.1 Steel work in built up tubular (round, square or rectangular hollow tubes kg 29244.00 154.90 45,29,895.60
etc.) trusses etc., including cutting, hoisting, fixing in position and applying
a priming coat of approved steel primer, including welding and bolted with
special shaped washers etc. complete.
Hot finished welded type tubes
45 11.5 62 mm thick cement concrete flooring with concrete hardener topping, sqm 50.00 928.65 46,432.50
under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand
: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick
cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded
stone aggregate, 6mm nominal size) by volume, hardening compound
mixed @ 2 litre per 50 kg of cement or as per manufacture’s
specifications. This includes cost of cement slurry, but excluding the cost
of nosing of steps etc. complete.
46 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and sqm 577.00 1,706.60 9,84,708.20
jointed with grey cement slurry mixed with pigment to match the shade of
the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) :
47 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and sqm 23.50 2,038.55 47,905.93
pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3
coarse sand) and jointed with grey cement slurry mixed with pigment to
match the shade of the slabs, including rubbing and polishing complete.
48 11.31 Extra for pre finished nosing in treads of steps of Kota stone/ sand metre 90.00 157.35 14,161.50
49 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: sqm 252.00 1,063.45 2,67,989.40
15622 (thickness to be specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados,
over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)
and jointing with grey cement slurry @ 3.3kg per sqm, including pointing
in white cement mixed with pigment of matching shade complete.
50 11.37A Providing and fixing 1st quality ceramic glazed floor tiles conforming to sqm 90.00 938.50 84,465.00
IS : 15622 (thickness to be specified by the manufacturer ) of approved
make in all colours, shades except burgundy, bottle green, black of any
size as approved by Engineer-in-Charge in skirting, risers of steps and
dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm
including pointing in white cement mixed with pigment of matching shade
51 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be sqm 510.00 1,416.65 7,22,491.50
specified by the manufacturer) with water absorption less than 0.08%
and conforming to IS: 15622, of approved make, in all colours and
shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse
sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting
the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
52 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be sqm 51.00 1,466.50 74,791.50
specified by manufacturer), with water absorption less than 0.08 % and
conforming to I.S. 15622, of approved make, in all colours & shade, in
skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1
cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/
sqm including grouting the joint with white cement & matching pigments
Size of Tile 600x600 mm
53 12.1.2 Providing corrugated G.S. sheet roofing including vertical / curved surface sqm 1987.50 1,135.45 22,56,706.88
fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with
bitumen and G.I. limpet washers or with G.I. limpet washers filled with
white lead, including a coat of approved steel primer and two coats of
approved paint on overlapping of sheets complete (up to any pitch in
horizontal/ vertical or curved surfaces), excluding the cost of purlins,
rafters and trusses and including cutting to size and shape wherever
0.80 mm thick with zinc coating not less than 275 gm/m²
54 12.52.3 Providing and fixing tiled false ceiling of specified materials of size sqm 54.00 1,948.95 1,05,243.30
595x595 mm in true horizontal level, suspended on inter locking metal
grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/
sqm, both side inclusive) consisting of main "T" runner with suitably
spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center
and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet,
1200 mm long spaced between main "T" at 600 mm center to center to
form a grid of 1200x600 12.5 mm thick square edge PVC Laminated
Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard,
manufactured from natural gypsum as per IS 2095 part I and laminated
with white 0.16mm thick fire retardant PVC film on the face side and
12micron metalized polyester on the back side with all edges sealed with
the face side PVC film which goes around and wraps the edges and is
bonded to the edges and the back side metalized polyester film so as to
make the tile a completely sealed unit.
55 13.1.1 12 mm cement plaster of mix : sqm 1883.00 294.85 5,55,202.55
1:4 (1 cement: 4 fine sand)
56 13.12 18 mm cement plaster in two coats under layer 12 mm thick cement sqm 1006.30 461.85 4,64,759.66
plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick
cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with
57 13.15 20 mm cement plaster 1:2 (1 cement : 2 stone dust). sqm 300.00 450.30 1,35,090.00
58 13.16.1 6 mm cement plaster of mix : sqm 1310.00 253.05 3,31,495.50
1:3 (1 cement : 3 fine sand)
59 13.80 Providing and applying white cement based putty of average thickness sqm 3696.15 123.85 4,57,768.18
1 mm, of approved brand and manufacturer, over the plastered wall
surface to prepare the surface even and smooth complete.
60 13.41.1 Distempering with oil bound washable distemper of approved brand and sqm 15965.00 162.55 25,95,110.75
manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming
coat with cement primer
61 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade : sqm 10363.00 166.85 17,29,066.55
New work (Two or more coat applied @ 1.67 ltr/10 sqm
over and including priming coat of exterior primer applied
62 13.61.1 Painting with synthetic enamel paint of approved brand and sqm 438.66 131.45 57,661.86
manufacture to give an even shade :
Two or more coats on new work
63 16.8.1 Brick edging laid lengthwise with half brick depth including excavation, metre 312.00 49.90 15,568.80
refilling and disposal of surplus earth lead upto 50 metres :
With common burnt clay F.P.S. (non modular) bricks of
class designation 7.5
64 16.71 Providing and fixing G.I. chain link fabric fencing of required width in mesh sqm 250.00 971.90 2,42,975.00
size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with
2 mm dia wire or nuts, bolts and washers as required complete as per the
direction of Engineer-in-charge.
65 16.68 Providing and laying 60mm thick faciory made cement concrete sqm 1712.00 951.00 16,28,112.00
interlocking paver block of M -30 grade made by block making machine
with strong vibratory compaction, of approved s;ze, design & shape, laid
in required colour and pattern over and including 50mm thick compacted
bed of coarse sand, filling the joints with line sand etc. all complete as per
the direction of Engineer-in-charge.
66 0052 Front end loader 1 cum bucket capacity (incl POL) hour 350 1,300.00 4,55,000.00
68 16.1 Preparation and consolidation of sub grade with power road roller of sqm 2,951.00 180.50 5,32,655.50
8 to 12 tonne capacity after excavating earth to an average of 22.5
cm depth, dressing to camber and consolidating with road roller
including making good the undulations etc. and re-rolling the sub
grade and disposal of surplus earthwith lead upto 50 metres.
69 16.31.1.1 Providing and applying tack coat using bitumen emulsion conforming Sqm 2,681.75 11.60 31,108.30
to IS:8887, using emulsion pressure distributer including preparing
the surface & cleaning with mechanical broom.
With rapid setting bitumen emulsion
On W.B.M / W.M.M. @ 0.4kg/sqm
70 16.31.1.2 Providing and applying tack coat using bitumen emulsion conforming Sqm 2,412.50 7.90 19,058.75
to IS:8887, using emulsion pressure distributer including preparing
the surface & cleaning with mechanical broom.
With rapid setting bitumen emulsion
On bituminous surface @ 0.25kg/sqm
71 16.55.1 Providing and laying bituminous macadam using crushed stone Cum 180.94 7,756.40 14,03,423.63
aggregates of specified grading premixed with bituminous binder,
transported to site by tippers, laid over a previously prepared surface
with paver finisher equiped with electronic sensor to the required
grade, level and alignment and rolling with smooth wheeled, vibratory
and tandem rollers as per specifications to achieve the desired
compaction and density, complete
50 to 100 mm average compacted thickness with bitumen
of grade VG-30 @ 3.50% (percentage by weight of total
mix) prepared in Batch Type Hot Mix Plant of 100-120
TPH capacity.as per specificatons and directions
of Engineer-in-Charge.
72 16.79 Providing, laying, spreading and compacting graded stone aggregate Cum 536.35 2,803.65 15,03,737.68
(size range 53 mm to 0.075 mm ) to wet mix macadam (WMM)
specification including premixing the material with water at OMC in
for all leads & lifts, laying in uniform layers with mechanical
paverfinisher in sub- base / base course on well prepared surface
and compacting with vibratory roller of 8 to 10 tonne capacity to
achievethe desired density, complete as per specifications and
directions of Engineer-in-Charge.
73 16.56.2 Providing and laying semi- dense Bituminous concrete using crushed sqm 7,065.00 247.35 17,47,527.75
stone aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site by tippers,
laying with paver finisher equiped with electronic sensor to the required
grade, level and alignment and rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction and density
as per specification, complete and as per directions of Engineer-
25 mm compacted thickness with bitumen of grade VG 30 @ 5%
(percentage by weight of total mix) and lime
filler @ 2% (percentage by weight of Aggregate) prepared
in Drum Type Hot Mix Plant of 60-90 TPH capacity.
74 NS1 Supplying and fixing polycarbonate multiwall 15mm sheet complete as sqm 545.14 1,380.80 7,52,726.55
per direction of EIC.
75 NS2 Extra for cutting, levelling, grading, watering for available earth in field in sqm 6225.00 23.26 1,44,793.50
desired slope in all respect as per direction of EIC.
Total of civil works 608,48,553.43 8,97,520.05
75 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) Each 2 5781.35 11562.70
with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors
wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests
76 17.2.1 Providing and fixing white vitreous china pedestal type water closet Each 8 5540.55 44324.40
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors
wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
77 17.16A Providing and fixing 8mm dia C.P./S.S. Jet with flexible tube upto 1meter Each 8 299.35 2394.80
long with S.S. Triangular plate to european type W.C. Of approved quality
and make as approved by engineer in charge.
78 17.7B Providing and fixing wash basin with C.I. brackets, 15 mm PTMT Each 9 2521.85 22696.65
pillar cock, 32 mm PTMT waste coupling of standard pattern, including
painting of fittings and brackets, cutting and making good the walls
wherever required. White Vitreous China Flat back wash basin size
550x400 mm with single 15 mm PTMT pillar cock.
79 17.22A Providing and fixing CP Brass 32mm size bottle trap of approved quality & Each 9 886.25 7976.25
make and as per the direction of engineer in charge.
80 17.28.2.2 Providing and fixing P.V.C. waste pipe for sink including P.V.C. waste Each 9 104.35 939.15
fittings complete.
81 18.58.1.1 Providing and fixing PTMT grating of approved quality and colour. Each 9 33.20 298.80
100 mm nominal dia
82 17.30 Providing and fixing in position 25 mm diameter mosquito proof coupling Each 9 45.30 407.70
of approved municipal design.
83 17.32.2 Providing and fixing mirror of superior glass (of approved quality) and of Each 9 1158.95 10430.55
required shape and size with plastic moulded frame of approved make
and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
84 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 Each 9.00 204.70 1842.30
mm wide with minimum distances of 37 mm from wall face with concealed
fittings arrangement of approved quality and colour, weighing not less
85 17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to Each 9 600.35 5403.15
wooden cleats with CP brass screws with concealed fittings arrangement
of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width
78 mm and effective height of 88 mm, weighing not less
86 18.21.2.1 Providing and fixing uplasticised PVC connection pipe with brass unions : Each 9 85.20 766.80
15 mm nominal bore
87 18.52.1 Providing and fixing C.P. brass stop cock (concealed) of standard design Each 9 594.75 5352.75
and of approved make conforming to IS:8931.
88 18.49.1 Providing and fixing C.P. brass bib cock of approved quality conforming to Each 18 434.20 7815.60
15 mm nominal bore
89 18.50.1 Providing and fixing C.P. brass long nose bib cock of approved quality Each 9 715.05 6435.45
conforming to IS standards and weighting not less than 810 gms.
15 mm nominal bore
90 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser Each 27 500.35 13509.45
points of approved quality conforming to IS:8931
a) 15 mm nominal bore
91 18.65 Providing and fixing PTMT soap Dish Holder having length of Each 9 96.75 870.75
138mm,breadth 102mm, height of 75mm with concealed fitting
arrangements, weighing not less than 106 gms.
92 18.8.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, Metre 162.00 441.15 71466.30
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes jointing of pipes & fittings with one
step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction
of Engineer in Charge.
Concealed work, including cutting chases and making good the walls
15 mm nominal dia Pipes
93 18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, Metre 108.00 513.75 55485.00
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes jointing of pipes & fittings with one
step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction
of Engineer in Charge.
Concealed work, including cutting chases and making good the walls
20 mm nominal dia Pipes
94 18.8.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, Metre 54.00 626.05 33806.70
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes jointing of pipes & fittings with one
step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction
of Engineer in Charge.
Concealed work, including cutting chases and making good the walls
25 mm nominal dia Pipes
95 18.8.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, Metre 54.00 712.75 38488.50
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps
at 1.00 m spacing. This includes jointing of pipes & fittings with one
step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction
of Engineer in Charge.
Concealed work, including cutting chases and making good the walls
32 mm nominal dia Pipes
96 19.7.1.1 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement Each 25.00 11687.10 292177.50
: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement :
1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm
nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),
inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with floating coat of neat cement and making
channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating
coat of neat cement complete as per standard design : Inside size 90x80
cm and 45 cm deep including C.I. cover
with frame (light duty) 455x610 mm internal dimensions,
total weight of cover and frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg) : With common burnt
clay F.P.S. (non modular)
bricks of class designation 7.5
97 17.23 Providing and fixing white vitreous china flat back or wall corner type each 2 1382.30 2764.60
lipped front urinal basin of 430x260x350 mm or 340x410x265 mm
sizes respectively.
98 NS-PL1 Providing and fixing uPVC pipes type -B conforming to IS: 13592 for soil, metre 108.00 719.00 77,652.00
waste and vent pipes including all fittings rubber ring type (plain or with
access door) e.g. bends, junctions, cowls, offsets, access pieces, jointing
with rubber ring joints with lubricant etc. fixed with clamps to walls.
For soil, waste and vent pipes
110 mm OD (6 kg pressure)
99 NS-PL3 Providing, fixing, jointing and testing in position the following uPVC pipes metre 54.00 176.10 9,509.40
conforming to IS 4985 of 6 kg/sqcm pressure rating including all fittings,
solvent weld joints, testing complete for drainage system cut to required
length to be laid under floor and making good the same complete as
For waste pipes
40mm OD (6 kg pressure)
100 NS-PL4 Providing, fixing, jointing and testing in position the following uPVC pipes metre 54.00 234.80 12,679.20
conforming to IS 4985 of 6 kg/sqcm pressure rating including all fittings,
solvent weld joints, testing complete for drainage system cut to required
length to be laid under floor and making good the same complete as
For waste pipes
50mm OD (6 kg pressure)
101 NS-PL6 Providing and fixing uPVC cleanout plug with openable cap for uPVC each 18.00 410.90 7,396.20
102 NS-PL7 Providing and fixing 110x110 mm uPVC 'P' trap with 2-3 inlets required each 18.00 770.30 13,865.40
size ftting with seal 50 mm of self cleansing design floor/urinal trap
without vent suspended with supporting clamp or in sunken portion
including cutting and making good the walls and floors wherever required
complete in all respects.
110 x110 mm outlet
103 NS-PL8 Providing and fixing uPVC floor drain of following size inlet and outlet each 18.00 264.10 4,753.80
including cutting and making good the walls and floors wherever required
complete in all respects.
110 x63mm outlet
104 NS-PL9 Providing & fixing PVC inlet fitting with one or more inlets fabricated from each 18.00 777.70 13,998.60
110 mm outer dia UPVC pipe and solvent welded sockets and fixed to
UPVC Trap and as per drawing complete
105 NS-PL10 Providing and fixing P.V.C. WC Connector (Straight/ or bend Type) with each 18.00 719.00 12,942.00
rubber lip ring, including 110mm dia PVC Pipe/ Bend of required length
and proper connection with M seal to C.I./PVC Pipe Complete as
106 2.10.1.1 Excavating trenches of required width for pipes cables etc including Metre 240 255.55 61332.00
excavation for sockets, and dressing of sides, ramming of bottoms, depth
upto 1.5 m ncluding getting out the excavated soil , and then returning the
soil as required , in layers not exceeding 20 cm in depth including
consolidating each deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed , within a lead of 50 m.
All kind of soil
Pipes, cables etc. not exceeding 80mm dia.
107 18.10.3 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, metre 72 491.20 35366.40
i/c cutting and making good the walls etc.
Internal work - Exposed on wall
25 mm dia nominal bore
108 18.12.4 Providing and fixing G.I. pipes complete with G.I. fittings including metre 48 457.70 21969.60
trenching and refilling etc.
32 mm dia nominal bore
109 18.12.5 Providing and fixing G.I. pipes complete with G.I. fittings including metre 240 558.35 134004.00
trenching and refilling etc.
40 mm dia nominal bore
110 18.13.1 Making connection of G.I. distribution branch with G.I. main of following each 30 757.10 22713.00
sizes by providing and fixing tee, including cutting and threading the
pipe etc. complete :
25 to 40 mm nominal bore
111 18.18.3 Providing and fixing ball valve (brass) of approved quality, High or low Each 20 399.15 7983.00
pressure, with plastic floats complete :
25 mm nominal bore
112 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved Each 20 532.35 10647.00
quality (screwed end) :
25 mm nominal bore
113 18.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved Each 15 589.90 8848.50
quality (screwed end) :
32 mm nominal bore
114 18.17.3 Providing and fixing gun metal gate valve with C.I. wheel of approved each 30 707.30 21219.00
quality (screwed end) :
40 mm nominal bore
115 18.19.2.2 Providing and fixing gun metal non- return valve of approved quality each 15 777.90 11668.50
(screwed end) :
32 mm nominal bore
116 18.19.3.1 Providing and fixing gun metal non- return valve of approved quality each 24 815.05 19561.20
(screwed end) :
40 mm nominal bore
117 18.46.3 Providing and fixing G.I. Union in G.I. pipe including cutting and threading Each 15 369.35 5540.25
the pipe and making long screws etc. complete (New work) :
25 mm Nominal Bore
118 18.46.4 Providing and fixing G.I. Union in G.I. pipe including cutting and Each 15 409.45 6141.75
threading the pipe and making long screws etc. complete (New
32 mm nominal bore
119 18.46.5 Providing and fixing G.I. Union in G.I. pipe including cutting and Each 15 523.20 7848.00
threading the pipe and making long screws etc. complete (New
40 mm nominal bore
120 18.38.3 Painting G.I. pipes and fittings with synthetic enamel white paint with two Metre 72 25.60 1843.20
coats over a ready mixed priming coat, both of approved quality for new
25 mm dia nominal bore
121 18.38.4 Painting G.I. pipes and fittings with synthetic enamel white paint with two Metre 48 30.70 1473.60
coats over a ready mixed priming coat, both of approved quality for new
32 mm dia nominal bore
122 18.38.5 Painting G.I. pipes and fittings with synthetic enamel white paint with two Metre 240 36.05 8652.00
coats over a ready mixed priming coat, both of approved quality for new
40 mm dia nominal bore
123 18.48 Providing and placing on terrace (at all floor levels) polyethylene water per Litre 12,500.00 9.7 121250.00
storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
124 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes Metre 18.00 319.75 5755.50
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes.
110 mm diameter
125 12.43.2 Providing and Fixing on wall face unplasticised - PVC pipe clips of Each 72 309.50 22284.00
approved design to unplasticised - PVC rain water pipes by means of 50 x
50 x 50 mm hard wood plugs, screwed with M.S. screws of required
length including cutting brick work and fixing in cement mortar 1:4 (1
Cement: 4 Coarse sand) and making good the walls etc. complete
126 19.4.2.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete Each 24 2474.40 59385.60
with C.I. grating brick masonry chamber with water tight C.I. cover with
frame of 300 x300 mm size (inside) the weight of cover to be not less than
4.50 kg and frame to be not less than 2.70 kg as per standard design :
150 x 100mm size P-type
With common burnt clay F.P.S. (non modular) bricks of class designation
127 19.7.1.2 Constructing brick masonry manhole in cement mortar 1:4 ( 1 Each 12 11567.00 138804.00
cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1
cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20
mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4
coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal
size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement
: 3 coarse sand) finished with floating coat of neat cement and
making channels in cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size) finished with
a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover
with frame (light duty) 455x610 mm internal dimensions,
total weight of cover and frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg) :
With Sewer bricks conforming to IS : 4885
128 19.6.2 Providing and laying non-pressure NP2 class (light duty) R.C.C. Metre 72 493.10 35503.20
pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete :
150 mm dia. R.C.C. pipe
129 23.1.1.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by Metre 200 592.05 118410.00
suitable method prescribed in IS: 2800 (part I), including collecting
samples from different strata, preparing and submitting strata chart/ bore
log, including hire & running charges of all equipments, tools, plants &
machineries required for the job, all complete as per direction of Engineer
-in-charge, up to 90 metre depth below ground level.
All Types of Soil
130 23.1.2.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by Metre 140 1416.30 198282.00
suitable method prescribed in IS: 2800 (part I), including collecting
samples from different strata, preparing and submitting strata chart/ bore
log, including hire & running charges of all equipments, tools, plants &
machineries required for the job, all complete as per direction of Engineer
-in-charge, up to 90 metre depth below ground level.
Rocky strata including Boulders
131 23.3.3 Supplying, assembling, lowering and fixing in vertical position in bore well, Metre 140 971.30 135982.00
unplasticized PVC medium well casing (CM) pipe of required dia,
conforming to IS: 12818, including required hire and labour charges,
fittings & accessories etc. all complete, for all depths, as per direction of
Engineer-in-charge.
200 mm nominal size dia
132 23.4.3 Supplying, assembling, lowering and fixing in vertical position in bore well Metre 140 1099.25 153895.00
unplasticized PVC medium well screen (RMS) pipes with ribs, conforming
to IS: 12818, including hire & labour charges, fittings & accessories etc.
all complete, for all depths, as per direction of Engineer-in-charge.
200 mm nominal size dia
133 23.13.3 Providing and fixing suitable size threaded mild steel cap or spot welded Each 2 280.95 561.90
plate to the top of bore well housing/ casing pipe, removable as per
requirement, all complete for borewell of:
134 23.15.3 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of Each 2 308.55 617.10
pipe assembly of tubewell as per IS:2800 (part I).
Total Plumbing work 20,14,757.15 1,52,796.60
Polyhouse works -
135 NS-PH1 Supply, erection, testing and commissioning of polyhouse including sqm 4700.00 945.50 44,43,850.00
Structural Materials i.e. G.I. Pipes, Profiles, G.I. Clamps, Hard wear,
Polycarbonate sheet , and , Zigzag Locking Springs fan pad system with
Misting irrigation system at RLBCAU campus as per the design, drawing
and technical specification complete including all items specified in
specifications in all respect as per the direction of Engineer-in-
charge/client (Excluding cost of civil works) (Plan area to be measured for
Total Poly house Work - 44,43,850.00
Prefab structure items -
139 NS-PF1 SITC of 80 mm thick Sandwich Roof Panel with internal flat liner with an sqm 622.14 4,175.00 25,97,434.50
insulation core of CFC free PUF/PIR foam fire retardant, self
extenguishing with minimum 40kg/m3 density conform to DIN 4102.
0.5mm TCT Colour coated Profiled sheet with yield strength 280MPA
confirming to IS-12426 on external facing. Closed cell content to be 90%
minimum. The panels have a protective guard film of minimum 20-25
microns to avoid scratches to finishing flashing during transportation. The
panels shall be fixed on the purlins with self-drilling, self-tapping fasteners
of approved quality and anti-corrosive polymer coated with integral
washers and EPDM seals complete as per specification and direction of
140 NS-PF2 SITC of 60 mm thick Sandwich Wall Panel with internal flat liner with an sqm 1212.87 4,019.40 48,75,009.68
insulation core of CFC free PUF/PIR foam fire retardant, self
extenguishing with minimum 40kg/m3 density conform to DIN 4102.
0.5mm TCT Colour coated Profiled sheet with yield strength 280MPA
confirming to IS-12426 on both facing. Closed cell content to be 90%
minimum. The panels have a protective guard film of minimum 20-25
microns to avoid scratches to finishing flashing during transportation. The
panels shall be fixed on the purlins with self-drilling, self-tapping fasteners
of approved quality and anti-corrosive polymer coated with integral
washers and EPDM seals complete as per specification and direction of
141 NS-PF3 Fixing & Covering all joints of above panels using proper & suitable size sqm 609.50 609.50 3,71,490.25
Flashings, comprising of 0.5 mm TCT Colour Coated Sheet. The Colour
Coated sheets will have substrate of Yield Strength 280 MPA and finish
as per IS 12426. The Flashing have a protective guard film of minimum
20-25 microns to avoid scratches to finishing.
142 NS-PF4 SITC of Flush Puf Door of 30 mm thickness with single rebate Frame with sqm 13.00 35,299.00 4,58,887.00
chrome finished accessories such as mortice lock, tower bolt and door
closure excluding toilet size as per specification and direction of EIC.
143 NS-PF5 SITC OF TEMPERATURE & LIGHT CONTROLLED TISSUE CULTURE 1 job 1.00 24,98,617.60 24,98,617.60
ROOM WITH TISSUE CULTURE CASTOR RACKS IN BUILDING AS
PER DIRECTION OF EIC.
Temperature Range: 15°C – 28°C±1°C
Humidity: 65% - 90% ± 5%.
Light Intensity: 6 – 10 Klux.
PUFF Panel thickness: 60 mm
General Tolerance: ± 5mm
PUFF Density: 60 ± 2 kg/m3
Panels are joints together by means to tongue and groove and locked
together & Camlock system on each side to ensure air tightness and
leakage. Both side 0.5mm thick Sheet
All joints of chamber to be properly sealed with Silicon sealant to avoid
any temperature loss.
Covered with pre painted sheets, thereby eliminating any fungal growth
WALL AND CEILING INSULATION OF GROWTH AND INOCULATION
ROOM: With puff 60mm thick Grade 38 Kg/m³ with Polyester pre-coated
GI outer surface having 60 mm polyurethane (Puff ) insulation
Pre-fabricated (Easy to install) panel system duly sealed to prevent
leakage. Flushed door (6’ x 3’) duly insulated may be provided with see
through hatch window of 35cm x 35cm (Toughened Vacuum Glass
Panel fitted with aluminum section)
Floor made of PUFF panels of thickness 60mm, PUFF Density: 60±2
kg/m3 to be use in main Chamber, superimposed with ply 6mm and fitted
with Anti Skid chequered aluminum Sheet.
Door is provided with magnetic door closer and made of thick Stainless
Steel Sheet from inside &
PPGI Sheet from outer side. Puff density 60kg ±2/m3,
HEAT CONVECTOR: Heat convector with paralytic technique, Auto
thermal cut off device, 2 / 2.4 KW heater, variable speed selector switch
selective combustive material chosen for minimum utilization for
atmospheric oxygen, Input 200-240 VAC, 50 HZ, single phase.
Ambient 5°C to 50°C, RH up to 90%.
COOLING SYSTEM:
Complete 15000+ BTU machine with ISI mark CFC free Eco friendly
HERMATIC sealed compressor
of EMERSON make (Imported) with wall mounted type sleek design
evaporator, Compressor coupled
with evaporation coil and condenser.
Split type indoor & outdoor unit and the Condenser Unit shall be placed
in well-ventilated area to avoid
throw of hot air in the stability room
Condensing unit is of sleek design, pressed sheet metal component,
inner grooved copper tubes, slit
aluminum fins, permanently lubricated fan and motor.
High insulation K value and superior characteristics thermal coefficients
and insulation. No messy civil
work thereby reducing installation time
ROOM TEMPERATURE:
Temperature Range: 15°C – 28°C
Accuracy: ±1.0°C
Digitally Controlled by Microprocessor based PID Digital Temperature
Indicator Cum Controller.
DE-HUMIDIFICATION SYSTEM:
Humidity shall be maintained from 55%RH to 95%RH (±3%) at
Temperature Range +15°C to +25 ºC, Multidirectional
air outlet, The multi-directional front outlet provides a wide range of air
circulation which dries
more space desired. Microcomputer automatic control, Movable handle
and easy-glide casters, Compact
design with a handle. Easy to lift, Casters allow the unit to be moved
easily from one place to another. Air
purifying filter Option Besides the nylon filter and activated charcoal filter
can be used for removing dust,
smoke and unpleasant odor. Power: 220-240V, 50Hz Microcomputer
humidity-level controls
ULTRA SONIC VAPOUR HUMIDIFIER: It creates the simulated natural
humidity in Growth Room any specific room without disturbing the inside
temperature because vapour comes out in cold form.
Salient Features:
ELECTRICAL WIRING
Electrical Device: High quality ISI approved fittings with FR grade copper
cable (ISI standard make) and rigid Stds of safety with proper M.C.B. and
main ON/OFF switch. Complete with electric wiring. Inside the lab and
main connecting cable should be provided.
Fitted with Microprocessor based Profile Controller which can be pre
programmed as per different Temperature & Humidity required.
SAFETY & ALARM SYSTEM:
Control panel shall be fitted with Safety devices for Temperature &
Humidity Over & Undershoot. Time delays relay & overload protection
circuit to safeguard the compressor & to enhance the compressor life.
Panel fitted with Audio-visual alarms for Temperature & Humidity
ILLUMINATION SYSTEM: 3000 LUX, Inner Chamber shall be fitted with
lights to provide the Illumination.
POWER SOURCE : 220-240VAC, 50Hz, single / Three phase
COLD ROOM SIZE: 13’ x 10’ x 10’ (W x L x H)
Frame is made of 25 x 25 mm square pipe with siemens gray / off white
Shelf to shelf distance 37.5 cm (15”) Shelf base is made of good quality
Four No's of tube light is fitted with every shelf (i.e. total 16 tube lights)
to produce excellent photo simulated light Illumination: 1.2K Lux at 5 cm
above shelf level ^ 8K lux at 15 cm above shelf level
separate switch if provided for each tube light.
Electronic ballast is connected with every tube light. 200-220 V AC
144 NS-6 Supply of Aquirium of 3.5 feet x 2 feet x 2 feet approx, capacity min. 150 each 2.00 45,228.80 90,457.60
lit., with water rotating filter, pump, temperature control system,
ornamental work inside with pebbles, trees etc. as required, ornamental
fish minimum 10 nos , two turtle (gold fish or equivalent of minimum 100
mm size in length), storage box at bottom complete in all respect as per
direction of client/ EIC
145 NS-7 Providing and fixing Aluminium Partition panel of 3mm thickness with sqm 150.00 868.70 1,30,305.00
framing (if required) at desired location complete in all respect as per
direction of Engineer in charge
Total Prefab works - 110,22,201.63
PROJECT- : “Construction of different RKVY Units, Poly houses, compost unit, Development of tissue
culture lab, vehicle parking and training hall, hybridization facility and other miscellaneous farm & External
Development works for RLBCAU, Jhansi, UP”
SUMMARY OF COST ELECTRICAL WORKS
S.NO NAME OF SUB-HEAD
CPWD DSR 2018 items Non Scheduled items
1 SUB HEAD-I: W I R I N G & SUBMAIN 25,58,400.00
2 SUB HEAD -II : DISTRIBUTION BOARD 2,13,076.00
3 SUB HEAD - III : LIGHTING FIXTURE & FAN 29,400.00 3,34,550.00
4 SUB HEAD - IV :EARTHING WORK 3,70,474.00
SUB HEAD - V :MV CABLE LAYING & END
TERMINATION WORK
6 SUB HEAD - VI :CIVIL WORK 1,79,400.00
11 SUB HEAD - VII :DISTRIBUTION PANEL WORK 15,21,085.00
14 SUB HEAD - IX :SUPPLY OF MV CABLE WORK 18,94,720.00
15 SUB HEAD - X:SAFETY EQUIPMENT WORK 4,87,736.00
JHANSI SOQ-24SUMMARY- EXTERNAL ELECTRICAL WORK
Sub-Head - XI- EXTERNAL VIDEO SURVEILLANCE
SYSTEM (IP CCTV)
17 ANNUAL MAINTENANCE OF RO SYSTEM 7,71,631.00
18 Sub-Head - XIII- SEEDER MACHINE AND OTHERS 45,27,098.00
19 Solar Photovoltaic Work 2,95,998.49
TOTAL AMOUNT 169,54,385.49
TOTAL AMOUNT 169,54,385.49
JHANSI SOQ-25SUMMARY- EXTERNAL ELECTRICAL WORK
PROJECT- : “Construction of different RKVY Units, Poly houses, compost unit, Development of tissue culture lab, vehicle parking and training hall, hybridization
facility and other miscellaneous farm & External Development works for RLBCAU, Jhansi, UP”
BILL OF QUNATITIES FOR ELECTRICAL WORKS
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
1 SUB HEAD-I: W I R I N G & SUBMAIN
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable in surface / recessed medium class PVC conduit, with modular
1.0 1.10 switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in
2.0 1.12 surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper Metre 2500 200 500000
conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in
3.0 1.13 surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper Metre 100 308 30800
conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
4.0 1.14 copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4.2 1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre 420 249 104580
4.3 1.14.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire Metre 350 394 137900
4.4 1.14.10 4 X 10 sq. mm + 2 X 10 sq. mm earth wire Metre 550 543 298650
4.5 1.14.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Metre 450 752 338400
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate
5.0 1.25 switch box including connections but excluding modular plate etc. as required. Each 45 342 15390
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding
modular plate as required.
JHANSI SOQ-1External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
7.0 1.31 including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections Each 90 401 36090
etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,
8.0 1.32 including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, Each 60 495 29700
connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including
connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length
(upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including
10.0 1.45 providing and fixing phenolic laminated sheet cover on the fan box etc. as required. Each 45 203 9135
Installation of exhaust fan in the existing opening, including making good the damage, connection,
testing, commissioning etc. as required.
12.0 1.51 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. Each 15 168 2520
Total of Sub-Head - I carried to summary sheet 2558400
13.0 2 SUB HEAD -II : DISTRIBUTION BOARD
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
14.1 2.3.2 8 way, Double door Each 5 1760 8800
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution
board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din
15.0 2.4 bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/
JHANSI SOQ-2External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for
16.0 2.10 inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
20.0 2.14 circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve
21.0 2.17 TP MCB complete with connections, testing and commissioning etc. as required. Each 10 1146 11460
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed
plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with
chained metal cover for the socket out let and complete with connections, testing and commissioning etc.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm
23.0 2.21 thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as Each 10 226 2260
Total of Sub-Head - II carried to summary sheet 213076
SUB HEAD - III : LIGHTING FIXTURE & FAN
JHANSI SOQ-3External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all
types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5
24 1.41 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Each 175 168.00 29400
25 NS-1 Supply of Light fixture as given below
25.1 1.1 Supply of 15W(Nominal) Surface Mounted LED square/circular Downlighter. Each 80 1341.00 107280
25.2 1.2 Supply of 20W(Nominal) Wall/Surface mouted 4 ft. LED. Each 60 494.00 29640
25.3 1.3 Supply of 10 W(Nominal) Bulk head Light. Each 30 1765.00 52950
25.4 1.4 Supply of Mirror Light. Each 5 424.00 2120
Supply of 1200 mm sweep 3 blade energy saving Ceiling fan complete with assembling of blades, down
rod, shackle insulator, canopy etc. (BEE-5 Star)
Supplying of Plastic Body Ornamental Exhaust Fan Light duty 230V A.C 50 cycles, 300 mm sweep,
1300 rpm, energy efficient, complete erected in position with all accessories.
Total of Sub-Head - III carried to summary sheet 334550
28 Sub-Head - IV- EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry
29.0 5.2 enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and Each 12 5308.00 63,696.00
salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing
30.0 5.4 masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. Set 15 6216.00 93,240.00
with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing
31.0 5.5 masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. Set 2 10724.00 21,448.00
(but without charcoal/ coke and salt ) as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode,
including connection/ termination with GI thimble etc. as required.(For Pole earthing).
JHANSI SOQ-4External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including
connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including
connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I.
pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Total of Sub-Head - IV carried to summary sheet 3,70,474.00
36 Sub-Head - V - MV CABLE LAYING & END TERMINATION WORK
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following
37.0 7.1 size direct in ground including excavation, sand cushioning, protective covering and refilling the trench
etc as required.
37.2 7.1.2 Above 35 sq. mm and upto 95 sq. mm Metre 680 338.0 2,29,840.00
37.3 7.1.3 Above 95 sq. mm and upto 185 sq. mm Metre 550 352.0 1,93,600.00
37.4 7.1.4 Above 185 sq. mm and upto 400 sq. mm Metre 250 396.0 99,000.00
38.0 9 MV CABLE END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
40.0 MV CABLE JOINTING
JHANSI SOQ-5External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing
41.0 9.4 materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1
KV grade as equired.
Total of Sub-Head - V carried to summary sheet 15,41,787.00
42.0 14.0 Sub-Head - VI - CIVIL WORK
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC
43.0 14.1 collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and
refilling etc as required.
Total of Sub-Head - VI carried to summary sheet 1,79,400
44.0 NS-2 SUB HEAD - VII :DISTRIBUTION PANEL WORK .
The contractor shall consider the following details in their item rates, wherever required:
1 Supporting rigid steel framework.
2 Cubicle type, 14 gauge CRCA sheet steel enclouser.
3 Complete with interconnections and distribution bus bars.
4 Proper bonding to earth.
5 Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram.
6 Providing cable clamps / supports within distribution boards cable alley.
7 TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link.
8 All MCB’s shall be of minimum 10 KA breaking capacity.
9 All motor feeders MCCBs shall be of motor duty.
10 Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5.
11 Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.
12 IP 42 for indoor panels.
13 IP 54 for kitchen and laundry panels.
14 IP 55 for outdoor panels
15 All MCCB’s shall be provided with operating mechanism for door interlock.
JHANSI SOQ-6External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Current density of aluminium shall be 1 sq mm for 1.0 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1.25 amps for
rated current of bus bars.
17 Tinned copper earth bus shall be provided through out the length of each board.
18 All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS.
19 All hinged door shall be earthed through 4.0 sq mm tinned braided copper wire.
20 All panels shall have provision of the following:
Pad locking of Switch board doors.
Pad locking of MCCB’s handles in “OFF” Position.
Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various
21 transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor.
All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C”
characteristic and discharge lamps and UPS etc. shall be of type D characteristic.
All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation.
24 All PTs / control transformer shall be provided with centre tap earth secondary.
25 All DOL & Star-Delta Starters shall be provided with SPPR (single phase preventor relay) and 2 nos. of Aux.Contacts for Remote operation/monitor.
26 The Panel fabricator shall provide Al./ Copper Bus-bars link from Breakers wherever more than two nos. of cables are terminated in the breakers.
27 Readymade 16 SWG Sheet steel Enclosure with cutout For MCBs
The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermal magnetic releases upto 250 amps and miroprocessor
based above 250 amps capacity, unless specified otherwise.
29 Protection Releases Microprocessor based (PRMB) & Thermal magnetic (PRTM) shall be as described below .
A Protection Release Microprocessor Based (PRMB-1)
Over-current/long time protection range 40% - 100 % with Time setting
short circuit /short time protection range 100% - 1000 % with Time setting
Instantaneous short circuit Protection range 150% - 1200 % with Time setting
Earth Fault Protection range 20% - 100 % with Time setting
Under voltage & over voltage protection
Current unbalance
JHANSI SOQ-7External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Power (Active,Reactive & Apparent)
Energy ((Active,Reactive & Apparent)
B Protection Release Microprocessor Based (PRMB-2)
Over-current/long time protection range 40% - 100 % with Time setting
short circuit /short time protection range 100% - 1000 % with Time setting
Instantaneous short circuit Protection range 150% - 1200 % with Time setting
Earth Fault Protection range 20% - 100 % with Time setting
C Protection Release Microprocessor Based (PRMB-3)
Over-current/long time protection range 40% - 100 % with Time setting
Instantaneous short circuit Protection range 150% - 1200 % with Time setting
D Protection Release Thermal-Magnetic Based (PRTM)
(Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without
any extra cost ,as the figure indicated within the bracket are required maximum fault level of the panel).
49.0 FRONT OPERATED PANEL
Supply, installation, testing and commissioning of front operated, front access, totally enclosed, free
standing, dust and vermin proof Panel with IP65 ingress protection, fabricated from 2 mm thick CRCA
sheets, with hinged, gasketted and lockable doors including the cost of interconnections, copper crimping
lugs, brass glands, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz
system with 31 MVA rupturing capacity at 415 volts complete as per specifications, as required and as
50.0 2.1 Main External Lighting panel (IP-65)
JHANSI SOQ-8External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
1 No. 160 amps 4P MCCB (25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient
voltage surge suppression device suitable for 3 phases as per specifications.
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's
iv) 1 No. Digital Electronic KWH meter(Dual Source).
i) 1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
i) 8 Nos. 63A TP+NL MCCB (25 KA)
Main External Lighting panel (IP-65) as described above Set 1 159808 159808
51.0 2.2 Sub External lighting Feeder piller
1 No. 63A,4P MCCB (25kA) and ON/OFF indicating lamps.
1 No. 63A, 3 phase Timer Switch for automatic operation.
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps.
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB.
iii) 1 No. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's.
1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves.
Ten(10) nos 25 Amp 4P MCB, 10 KA.
Sub External lighting Feeder piller described as above Set 2 167072 3,34,144.00
52.0 2.3 Feeder Pileer-1 (IP-65)
1 No. 160 amps 4P MCCB (25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient
voltage surge suppression device suitable for 3 phases as per specifications.
JHANSI SOQ-9External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-160A) Ammeter with ASS with 3 nos. 160/5A CT's
iv) 1 No. Digital Electronic KWH meter(Dual Source).
i) 1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
i) 3 Nos. 100A TP+NL MCCB (25 KA)
Feeder Pileer-1 (IP-65) as described above Set 1 138016 138016
53.0 2.4 Feeder Pileer-5 (IP-65)
1 No. 630 amps 4P MCCB (25 KA) with thermal Magnetic release (PRMB-3) with Class-C transient
voltage surge suppression device suitable for 3 phases as per specifications.
B METERING & INDICATION FOR EACH INCOMER
i) 1 set of R,Y,B phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-630A) Ammeter with ASS with 3 nos. 600/5A CT's
iv) 1 No. Digital Electronic KWH meter(Dual Source).
i) 1 Set of 800A TPN Aluminium Bus Bar with colour coded PVC Sleeves
i) 5 Nos. 200A TP+NL MCCB (25 KA)
Feeder Pileer-5 (IP-65) as described above Set 1 421313 421313
54.0 2.5 Typical floor panel
1 No. 200 amps 4P MCCB(25 KA) with thermal Magnetic release
JHANSI SOQ-10External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
(PRMB-3) with Class-C transient voltage surge suppression device
suitable for 3 phases as per specifications.
B METERING & INDICATION
i) 1 set of R,Y,B phase indicating lamps
ii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iii) 1 No. (0-200A) Ammeter with ASS with 3 nos. 200/5A CT's
iv) 1 No. Digital Electronic KWH meter(Dual Source).
i) 1 Set of 250A TPN Aluminium Bus Bar with colour coded PVC
i) 4 Nos. 63A TP+NL MCCB (25 KA)
ii) 2 Nos. 63A TPN MCB (10 KA)
Typical Floor Panel described as above Set 4 116951 467804
Total of Sub-Head - VII carried to summary sheet 15,21,085.00
SUB HEAD - IX :SUPPLY OF MV CABLE WORK
55.0 NS-3 Supply of MV cable
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor
power/ multicore control armoured cable of 1.1 KV grade.
55.6 NS-3.5 3 ½ C - 35 sq mm Aluminium Metre 60 349.50 20,970.00
55.7 NS-3.6 4 C - 25 sq mm Aluminium Metre 50 304.00 15,200.00
55.8 NS-3.7 4 C - 16 sq mm Aluminium Metre 50 226.00 11,300.00
Total of Sub-Head - IX carried to summary sheet 18,94,720.00
56.0 NS-4 SUB HEAD - X:SAFETY EQUIPMENT WORK
56.1 4.1 Providing and fixing NO SMOKING & DANGER ZONE signboards. Nos. 2 353 706.00
56.2 4.2 Providing and fixing ISI marked CO2 4.5 Kg. Capacity as per latest IS. Nos. 10 13411 1,34,110.00
JHANSI SOQ-11External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
56.3 4.3 Providing and fixing ISI marked Chemical foam type of 9 liters as per latest IS (trolley marker). Nos. 10 17646 1,76,460.00
56.4 4.4 Providing and fixing ISI marked Dry chemical powder type (5 Kg.) as per latest IS. Nos. 10 17646 1,76,460.00
Total of Sub-Head - X carried to summary sheet 4,87,736
57.0 NS-5 Sub-Head - XI- EXTERNAL VIDEO SURVEILLANCE SYSTEM (IP CCTV)
Supply, installation, testing and commissioning of 2 megapixels resolution Network Bullet camera
camera,Imager 1/2.8” Progressive Scan CMOS,Video Compression. .H.264/MJPEG,Day/Night-IR Cut
Filter,Minimum Illumination-0Lux/F1.4(IR ON) IR Range-Up to 50 Meter,Electronic Shutter-
Auto/Manual(1/25~1/10000), Lens 2.8 to 12 mm Motorized zoom Lens,Resolution Main-
1920x1080p,Digital Noise Reduction-3D,Wide Dynamic Range-120db, Behavior Analysis-Line crossing
detection, intrusion detection, unattended baggage detection, object removal detection.Support Face
Detection. Region of Interest Support 1 ROI per stream.Power Consumption and Current- 12 VDC, 1.2A,
max. 14.5W PoE (802.3at, 42.5V to 57V), 0.5A to 0.1A, max. 16.5W.Protection Level IP67, IK10 TVS
2000V Lightning Protection, Surge Protection and Voltage Transient Protection.Regulatory UL, CE,
FCC.Operating Conditions Temperature: -30 °C to +60 °C (-22 °F to +140 °F).Humidity: 95% or less.
Supplying of 1/2.8’’ Progressive Scan CMOS PTZ Dome Camera with laser IR,Compression-
H.264/MJPEG/MPEG4,Focal Length - 4.3-129mm, Optical zoom 30x and digital zoom 16x,Max. Image
Resolution-1920×1080,Frame Rate 50Hz: 25fps(1920×1080) 360° endless pan range and -2°-90° tilt
range,240°/s Pan Preset Speed and 200°/s Tilt Preset Speed,0.1°-160°/s Manual Pan Speed and 1°-
120°/s Manual Tilt Speed,256 presets programmable; preset image freezing capability ,8 patrols, up to
57.2 5.2 32 presets per patrol 4 patterns, with the recording time not less than 10 minutes per pattern,SD/SDHC Each 1 324688.00 324688
card local storage Support up to 8 NAS storage; Edge recording (transmit the videos from SD card to the
NAS after network resumed) High performance Laser IR LED covering up to 500m (IR) distance 3D
intelligent positioning function,3D DNR,Protection Level-IP66 standard,TVS 6,000V lightning protection,
surge protection and voltage transient protection.
JHANSI SOQ-12External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Supplying of 2U Rack mount single chassis Network Video Recorder with dual Gb NIC, 1 DVI-I + HDMI
+ 1 Display Port, max 2 simultaneous monitors, RS-232/485 serial port, DVD, Server Operating System-
Windows 10,Ubuntu Linux 16.04, Processor-Gen 4 Intel Core i3, Local Client Display Rate
(FPS)Windows – 700 FPS (HD)Linux – 900 FPS (HD),High Performance, High Reliability IP Recorder.
— Continuously records 300Mbps (Windows) & 450 Mbps (Linux)of video while hosting a local client,
multiple remote clients and the web server on a single server,RAM-4 GB, 8 GB, 12 GB (Optional)solid-
state operating system drive,USB-6 x USB 2.0, 2 x USB 3.0 high air flow cooling and hardware
57.3 5.3 monitoring features ensure maximum uptime. keyboard and mouse, Professional Grade client and Each 1 776428.00 776428
server software pre-installed and software updates. Access live and recorded video on multiple client
PCs with free Windows, Mac or Linux client application. web server application is pre-installed on the
server to access video through a web browser or free Mobile iPhone / iPad and Android apps. Maximum
Storage Capacity 30TB & Maximum Hard Drive 3 Slot(Up to 10TB) Support Up to 64 IP Camera
57.4 5.4 Supply, installation, testing and commissioning of Enterprise Class 6TB HDD. Make-WD/Seagate Each 1 45174.00 45174
Supply, installation, testing and commissioning of Video Management System (VMS) software shall be
used to view live and recorded video from capture cards and IP devices connected to local and wide area
networks. The VMS software shall have a client/server-based architecture that can be configured as a
standalone VMS system with the client software running on the server hardware and/or the client running
on any network-connected TCP/IP workstation. Multiple client workstations shall be capable of
simultaneously viewing live and/or recorded video from one or more servers. Multiple servers shall also
57.5 5.5 be able to simultaneously provide live and/or recorded video to one or more workstations. The VMS Each 6 13835.00 83010
server software shall also have the ability to be installed on an IP edge device—such as an IP camera or
encoder that allows for 3rd party applications—allowing the device to serve as both a server and IP video
recording device.The VMS shall not charge for the number of concurrent clients (min. 50 thick clients and
16 mobile clients to be provided along with VMS).
Supply & Laying of outdoor armoured 4-pair Category 6 cable as per TIA-568C.2, The cable should be
57.6 5.6 tested till 250 MHz , Shall be Fire-Retardant, Low-Smoke & Zero-Halogen as per IEC 60332-1, IEC Mtrs 500 113.00 56500
61034-2 & IEC 60754-1 respectively.
JHANSI SOQ-13External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Supply, installation, testing & commissioning of Feeder Piller having IP55 Outdoor 17U Network Rack
with Hood and FAN For Field Devices. The Rack box shall be provided with external earthing lugs 5
57.7 5.7 socket Power terminaton with MCB or More Proper/Steady fixing through Each 2 74819.00 149638
Supply, installation, testing & commissioning of 12 Port PoE+ Switch with 2 SFP slots 12 x 10/100/1000
Base-T PoE+ ports and additional 2 100/1000X SFP PORTS Should support PoE+ as per IEEE 802.3 at
with PoE budget of 100W.Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, STP root guard,
57.8 5.8 Voice VLAN, MLD snooping (MLDv1 and v2), IEEE 802.3ac VLAN tagging IEEE 802.17/equivalent for Each 2 110112.00 220224
sub 50ms ring protection in following scenario : single, dual fibre cuts in ring and when fibre cut at
common shared link in between two or more rings.
Supply and fixing of 7.0 Mtrs G.I. Octagonal Pole (70 mm A/F (Top) x 130 mm A/F (Bottom) x 5 mm thick
with base plate of 250 x 250 x 16 mm, 4 nos. 600 mm long M20 foundation bolts & hardwares (suitable
reinforcements to be inserted in the foundation and 40mm x 2 nos. GI pipes for In/Out of main cables)
Any other accessories etc. required complete in all respect as per direction of Engineer in charge. The
pole shall also be provided with recessed lockable GI junction box of suitable size and flush door at the
bottom with proper strengthening for the cutout of the door opening of junction box. The cost of RCC
foundation shall be Included
Supply, installation, testing & commissioning of IP55 Outdoor Junction Box For Field Devices at camera
side. JB must be of appropriate size to house different components as per CCTV system design
confirming. The junction box shall be fixing along with weather proof clamping with pole as per site
Supplying, Installation,Testing & Commissioning of 40 " LED Full HD TV Resolution 1920 x 1080
,Contrast Ratio (Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source
Switching & Recovery, Lamp Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play
57.12 5.11 (DDC2B), Pivot Display, Clock Battery, PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, Each 1 56467.00 56467
HDCP Support, Smart Scheduling, Smart F/W update, Built-In MagicInfo Premium-Swith Mounting
Brackets as per Technical Specification complete in all respect. Approved
Supply, installation, testing & commissioning of online 1KVA fully Microprocessor Based UPS System
suitable for Single phase, AC 50 Hz. input supply comprising of following features.High Frequency PWM
57.13 5.12 Inverter using IGBT Technology Manual by pass switch LCD disply SMF VRLA Batteires with 30 minutes Each 2 35292.00 70584
back up time for full load including interconnecting cables Battery Rack.
JHANSI SOQ-14External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Supplying and laying of permanently Solid Lubricated Double Wall Corrugated HDPE Pipe 32 mm inner
57.14 5.13 dia with 40 mm outer dia, conforming to IS-14930 (Part-II), having anti rodancy features complete with Mtrs 150 226.00 33900
accessories including slip fit/push fit type couplers
57.15 5.14 Supply and laying of Heavy duty 25MM PVC Concduit along with all accessories. Mtrs 50 99.00 4950
Digging of Hard/Soft soil at 750mm depth including excavation and refilling of earth.This shall include
pull boxes and cable route markers every 50mtr with all accessories
Total of Sub-Head - XI carried to summary sheet 2229030
58.0 NS-6 Sub-Head - XII-MISCELLANEOUS
Annual Maintenance OF 1 NO RO 1500 LTR/HR capacity, 3 NO RO 250 LTR/HR capacity, 2 NO RO 10 1 job 1 771631 7,71,631.00
LTR/HR CAPACITY, 12 NO ACADEMIC WATER COOLERS , 4 NO ADMIN WATER COOLERS & 2 NO
HOSTEL COOLERS including 2 no of pressure pumps at RLBCAU UNIVERSITY as per direction of EIC.
59.0 NS-7 Sub-Head - XIII- SEEDER MACHINE AND OTHERS
Supply & Installation of Seeder Machine & Chamber for
Seeder Machine complete in all respect as per direction of engineer-in-charge
JHANSI SOQ-15External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Infrastructure:
Chamber for seeder machine
mm thick with false ceiling. With two door & two windows,. Roof hut type,
Floor: made by made by PCC (1:5:10)100 mm thick than CC (1:2:4) 100 mm thick with dully plastered.
Air bars within double row of nozzles and seed holding plate with pneumatic
with 2 drilled bars with mounted conveyer size 3000mm x 565mm
Electrical wiring as per required complete in all respect as per direction of Engineer in charge
Refilling of fire extinguisher cylinder of 6kg type ABC including filling the same at site/respective existing
Ns-8.1 location. Nothing extra shall be payable for handling, carriage of cylinders complete in all respect as per each 95 880 83,600.00
direction of Engineer in charge
Refilling of fire extinguisher cylinder of 4.5 kg CO2 type including filling the same at site/respective
Ns-8.2 existing location. Nothing extra shall be payable for handling, carriage of cylinders, complete in all each 95 660 62,700.00
respect as per direction of Engineer in charge
Refilling of fire extinguisher cylinder of 9 liter AFFF type including filling the same at site/respective
Ns-8.3 existing location. Nothing extra shall be payable for handling, carriage of cylinders, complete in all each 22 990 21,780.00
respect as per direction of Engineer in charge
JHANSI SOQ-16External Electrical Estimate
Sr. No. Description Unit Total Qty Rate (Rs) Amount( Rs )
Refilling of fire extinguisher cylinder of foam wheel type 60 liter including filling the same at
Ns-8.4 site/respective existing location. Nothing extra shall be payable for handling, carriage of cylinders, each 12 5133 61,596.00
complete in all respect as per direction of Engineer in charge
Total of Sub-Head - XII carried to summary sheet 45,27,098
59.0 NS-9 Solar Photovoltaic Work
Supply,Installation,TestingandCommissioningofongridSolarPhotovoltaicPowerPlantconformingtoMNREsp
ecificationsasamended,consistingofMono/PolyCrystallinesiliconsolarcells,netmeteringfacility,necessarypr
Ns-9.1 otections,earthing,mountedonAluminium/GIstructureofsuitablestrengthwithfollowingcomponents complete Kwp 4.847666 61060 2,95,998.49
a)SolarPhotovoltaicModuleofcapacity330Wporabove,manufacturedinIndia,conformingtoIS14286/IEC6121
5,IS/IEC61730-Part-1,IS/IEC61730-Part-
2.SolarPhotovoltaicModuleconversionefficiencyshallnotbelessthan16.5%.PVmodulesusedinsolarpowerpla
nts/systemsmustbewarrantedfortheiroutputpeakwattcapacity,whichshouldnotbelessthan90%attheendof10
yearsand80%attheend of 25 years.
b)PowerConditioningUnit(PCU)of350-800VDCInputvoltagerangeand400VAC,threephase,4wire,50Hz+/-
2.5Hz,outputvoltagesuitabletogenerateACPowerwithefficiencynotlessthan97%,totalharmonicdistortionless
than3%andsuitableforambienttemperaturefrom0to50degreeC.ThePCUshalladjustthevoltage and
frequency level to suit the Grid Voltage Frequency.
c) Data Monitoring System complete with accessories.
d ) Fixing of Array junction box& Main junction box with IP65
protectionandterminationarrangementforincomingandoutgoingcablealongwithglands,lugsand other
accessories etc. as required.
e) Lightning and surge voltage protection.
f)Connections&Interconnectionsbysupplying&fixingrequiredsizeXLPEinsulated
copperconductor1.1kVgradearmouredpowerandcontrolcablesbetweensolarmodules,mainpowercabletogri
dsupplyPCUunitalongwithsupplying&fixingofnecessarychannel/conduitlugsandotheraccessoriesetc.asreq
Total of Sub-Head carried to summary sheet 2,95,998.49
JHANSI SOQ-17External Electrical Estimate
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NITRKVY.pdf
Tender Document
RKVY BOQ Mushroom unit-R12 Rev.pdf
Tender Document
MAKE LIST RKVY.pdf
Tender Document
TechnicalspecificationRKVY.pdf
Tender Document
IPRKVY.pdf
Tender Document
GCCContracting2019withAmendment1to16.pdf
Tender Document
DRG-1.pdf
Tender Document
DRG-2.pdf
Tender Document
SCCRKVY.pdf
Tender Document
MilestoneRKVY.pdf
Tender Document
corrigendum-569-05corriRKVY.pdf
pdf • 0.28 MB
corrigendum-568-04corri.pdf
pdf • 0.28 MB
corrigendum-567-03 corrigendumrkvyprice.pdf
pdf • 0.28 MB
corrigendum-566-02corrigendumRKVYpricebid.pdf
pdf • 0.28 MB
corrigendum-543-prebidrkvy.pdf
pdf • 1.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .