| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹17.0 L+₹3,678 (0.22%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance Quoted Higher Rates | |
| 3 | L3₹17.2 L+₹24,460 (1.44%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L3 | Rejected-Finance Quoted Higher Rates |
Tender Value
Refer Docs
EMD Value
₹41,800
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ SWAPNESH KOLI GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIRS AND REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY AND ALLIED WORKS AT NAVY AREA UNDER GE (I) (CGP) KOLKATA
2021_MES_423131_2
8910/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹41,800
Yes
31 Mar 2021
8 Mar 2021
24 Mar 2021
8 Mar 2021
22 Mar 2021
8 Mar 2021
60 days
Amount
Repair/maintannces of transformer of any make 6 KV/440V step down type & capacity for 200KVA & below by disconnecting electric supply draining out transformer oil and stocking for reuse opening up top cover, checking /cleaning the core, HT/LT winding , tank conservator, connections etc removing sludge/scaling etc deposited. Opening the HT/LT terminal boxes, checking/ changing/cleaning the bushes oil seals, gaskets nuts & bolts etc as required number checking & replacement of top cover gasket, breather & vent pipe gasket, silica gel, reassembling testing & commissioning complete all as specified and as directed. (Note : (i) Maintenance /repairs of transforerms shall be carried out by trained technicians/mechanic under super vison of qualified electrical technician. (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate .
All as per item no. 1 above but capacity for 400KVA complete all as specified and as directed.
Removing existing old paint by scraping from transformer , fins and conservator tank, and applying two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, capacity in white paint complete all as specified and directed.
Dehydration & filteration of transformer oil by disconnecting the device from supply and draining out the complete oil, filtering the dirt, sludge and dehumidifying by heating the same and raising the Breakdown voltage level 60 KV at 2.5 mm gap and testing and recording the result for three times in specified interval including pouring the oil in transformer tank and charging the same to restore supply complete all as specified and as directed.
Supply & filling only Transformer Oil for topping up the level( after necessry disconnection and earthing both winding) with grade as per IS : 335 complete incl opening the tank cover and refixing the same and charging the transformer to the supply voltage complete all as specified and as directed including taking out old one. (Note : Die electric strength of the oil shall be ensured not less than 60 KV before filling) (Make of Oil - Poweroil/ Gulf)
Maintenance of Vaccum circuit Breaker, make: PASCAL, 6.0 KV Grade, 200 to 630 Amps by Auth representative including the following:- (a) Switiching off VCB and conforming that supply to incomming end is properly disconnecte. (b) Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear. (c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths. (d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable. (e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts. (f) Replacement of parts detective or less reliable parts from OEM (to be measured and paid seperately). (g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections. Note : 1. After servicing of VCB, Health check up reports will be submitted.
Removing existing old paint by scraping from Vaccum circuit breaker and applying two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, capacity in white paint complete all as specified and directed.
Supply and replacement of heating coil of Vaccum circuit breaker including taking down old burnt/unserviceable one complete all as specified and directed.
Supply and replacement of potential transformer of Vaccum circuit breaker including taking down old burnt/unserviceable one complete all as specified and directed.
Supply and replacement of current transformer of Vaccum circuit breaker including taking down old burnt/unserviceable one complete all as specified and directed.
Supply and replacement of power pack unit of Vaccum circuit breaker including taking down old burnt/unserviceable one complete all as specified and directed.
Calibration of various relays of Vaccum circuit breaker complete all as specified and directed. (Note -Report of calibration to be submitted to the department)
Supply only electrical insulating mat type C conforming to IS 15652:2006 for high tension appliance with standard width of 1.0 mtr and in customised length including taking down old burnt/unserviceable one complete all as specified and directed. (Note -Test Report to be submitted to the department)
Supply only electrical insulating mat type A conforming to IS 15652:2006 for low tension appliance with standard width of 1.0 mtr and in customised length including taking down old burnt/unserviceable one complete all as specified and directed. (Note -Test Report to be submitted to the department)
Disconnecting, repair and maintenance of APFC panel and replacement of internal wiring by new, checking and taking out defective unserviceable parts and replaced the same to make serviceable connection, testing etc. as directed. (Note: (i) Maintenance / repairs shall be carried out by trained technicians / mechanic under supervision of qualified electrical technician. (ii) All repairs shall be carried out at site only. (iii) Spare / parts shall be measured and paid seperately as ''supply only''
Supply only 5 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, complete all as specified and directed. (Make- L&T /BCH/ABB)
Supply only 10 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, complete all as specified and directed. (Make- L&T /BCH/ABB)
Supply only 20 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, complete all as specified and directed. (Make- L&T /BCH/ABB)
Supply only APFC Relay meter (8 Staps) complete all as specified and directed, (Make L&T /BCH/ABB).
Supply only capacitor duty contractors of 10kvar rating, type MO C10, size Fr 1 complete all as specified and directed, (Make L&T / BCH/ABB).
Supply only capacitor duty contractors of 20kvar rating, type MO C20, size Fr 1 complete all as specified and directed, (Make L&T / BCH/ABB).
Supply and fixing MCCB, 160 Amps, 4pole, 36 KA breaking capacity, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. (Make: L&T / BCH/ABB/LEGRAND).
Supply and fixing MCCB, 125 Amps, 4pole, 36 KA breaking capacity, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. (Make: L&T / BCH/ABB/LEGRAND).
Supply and fixing MCCB, 16 to 100 Amps, 4pole, 36 KA breaking capacity, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. (Make: L&T / BCH/ABB/LEGRAND).
M & L Cable jointing kit for 11 KV (Earthed) grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - 3M / Denson / Raychem)
M & L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - 3M / Denson / Raychem)
M & L Cable jointing kit for LT 1100 V grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - 3M / Denson / Raychem)
M & L Cable jointing kit for LT 1100 V grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - 3M / Denson / Raychem)
M & L Cable jointing kit for LT 1100 V grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3.5/4.0 core XLPE armoured aluminium conductor cable of size 25 sqmm to 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - 3M / Denson / Raychem)
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 4 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 35 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 11KV HT volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 95 Sqmm 3.0 core including taking down old one complete all as specified and as directed.
Supply and fixing hot dip galvanized steel perforated cable tray rectangular type of suitable width ranging from 4 inch to 8 inch to be fixed on wall complete all as specified and as directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L for sand cushioning for protection of cables (below, above and around the cable laid in trenches) complete using clean, dry sand complete all as specified and as directed.
Supply and laying well burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed.
M&L cement concrete 1:3:6 Type C1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work complete all as specified and directed.
S&F 80 mm dia steel water tube light grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
M&L for road cutting for laying of LT UG cable / galvanised iron pipe complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron or steel earth lead MS flat 25 x 4 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth wire protected by galvanised iron pipe 50 mm dia (light grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work including taking down old one complete all as shown in elect plate No. 3 of SSR Part I, all as directed by Engineer-in-Charge.
M&L for GI strip 25 mm x 4mm as earth continuity conductor fixed to wall/burried in ground/drawn through conduit or pipe or fixed to pole for loop earthing complete all as specified and directed including taking out old one.
S&F Aluminium strip 25 x 3.15mm with porceline insulator and fixing screws etc. as roof conductors and down conductors complete all as specified and directed including taking out old one work upto 4th floor storey.
Refixing of hanging / loosen earth strip/roof conductors of Cu/GI/AL with proper clamping, saddling and connected accessories at the original location complete all as specified and directed.
Refixing of hanging / loosen earth strip/down conductors of Cu/GI/AL with proper clamping, saddling and connected accessories at the original location complete all as specified and directed.
S&F 40 mm dia steel water tube light grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
M&L for RYB indicator lamp LED for input voltage 240V complete all as specified and directed. (Make - L&T/C&S /ABB)
S&F Volt meter 0-500 volts Digital type including taking down old one complete all as specified and directed.
S&F Ammeter 0-500 volts Digital type including taking down old one complete all as specified and directed.
Disconnecting the cable from any size from panel/feeder pillar box/ junction box carefully by removing gland and remove the loose/burnt cable lugs/connector and single core cables and crimping the new lugs & connecting complete all as specified and as directed. (Note - Single core copper cable with lugs/Tube terminal shall be measured and paid seperately)
Supply only copper single core multistranded copper cable along with suitable aluminium lugs and sleeve with necessary fittings for 16-50 sqmm XLPE cable complete all as specified & directed .
Supply only copper single core multistranded copper cable along with suitable aluminium lugs and sleeve with necessary fittings for 70-150 sqmm XLPE cable complete all as specified & directed .
Supply only copper single core multistranded copper cable along with suitable aluminium lugs and sleeve with necessary fittings for 185-400 sqmm XLPE cable complete all as specified & directed .
M&L for painting of LT panels,APFC panels, feeder pillar boxes, junction boxes, sheet metal enclosure and any other steel surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint (1st quality) of approved colour by spraying after removing all dust/rust /grease including preparation surfaces complete all as specified and directed.
Supply and fix LED street light 90 W IP 66 made up of pressure die cast aluminum housing with toughened glass and high poer LED and secondry lenses with system efficacy 110 LM/W including all fittings including taking down old unserviceable all as specified and as directed. Make: Cromption/Havells/Bajaj/Philips.
Supply and fix electronic driver for LED flood light/street light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
Supply and fix electronic driver for LED bollard light/post top lantern/spot light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
Supply and fix sheet steel enclosure 4 way TPN DB with 200 amps bus bar with provision for TPN MCB as incomer, double door type complete all as specified and directed. Make: Legrand/ABB/L&T/Siemens/ Schenieider.
Supply and fix MCB TPN 240V, 40-63 Amps capacity complete all as specified and directed. Make: Legrand/ABB/L&T/Siemens/ Schenieider.
Supply and fix SMC junction box fix to wall/pole , Size - 140 x 140 x 95 mm, with provision of cable incoming and outging including cable glands and 4 Pole PVC Connector all fittings including taking down old unserviceable one all as specified and as directed. Make- Sintex/Hensel/RMW
Supply and fix SMC junction box fix to wall/pole , Size - 200 x 140 x 95 mm, with provision of cable incoming and outging including cable glands and 4 Pole PVC Connector all fittings including taking down old unserviceable one all as specified and as directed. Make- Sintex/Hensel/RMW
Supply only onload changeover switch in sheet steel enclosure 250 Amps capacity all as specified and as directed. Make: L&T/Legrand/Schneider.
Supply and fixing battery 12 volt, 180 AH including taking down unserviceable battary complete all as specified and as directed. Make - Exide/Amron/Luminous
Repair/maintenances of transformer of 11 KV/440 V make step down type & capacity upto 300 KVA & disconnecting electric supply(( incoming & outgoing) draining out transformer oil and stocking for reuse opening up top cover, checking /cleaning the core, HT/LT winding , tank conservator, connections etc removing sludge/scaling etc deposited. Opening the HT/LT terminal boxes, checking/cleaning the bushes oil seals, gaskets nuts & bolts etc as required number checking & replacement of top cover gasket, breather & vent pipe gasket, reassembling testing & commissioning complete all as specified and as directed. (Note: Maintenance /repairs shall be carried out by trained technicians/mechanic . (ii) All repairs shall be carried out at site only. Necessary HV testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate)
M&L for oil seal for LT bushing of transformer of 6k v / 440 volts step down & capacity for 200 KVA below complete all as specified and directed( incl taking down old one)
M&L for brass studs incl buses, porceline, brass nuts, bolts, washers etc complete set for 200 KVA transformer(as per sample) incl taking down old one complete all as specified and as directed..
S & F thermometer with brass stiff necessary sensing device of range 0-120degC for indoor type transformer complete all as specified and as directed incl taking down complete.
S & F breather unit for transformer indoor type (As per sample) complete all as specified and as directed incl taking down complete.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 6 Sqmm 2.0 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 70 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
S&F 50 mm dia steel water tube light grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
Laying of old bricks in trenches as cable protection with width equal to the length of bricks complete all as specified and as directed.
Maintenance of Vaccum circuit Breaker, 11.0 KV Grade, 630 Amps by Auth representative including the following:- (a) Switiching off VCB and conforming that supply to incomming end is properly disconnecte. (b) Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear. (c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths. (d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable. (e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts. (f) Replacement of parts detective or less reliable. (g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections. Note : 1. After servicing of VCB, Health check up reports will be submitted.
Supply only spring action leaver (as per sample) for11 KV HT VCB Of capacity for 630 Amps complete all as specified and directed.
M & L Cable jointing kit for LT 1100 V grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 120 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - 3M/ Denson / Raychem)
Supply and fixing MCCB, 100 Amps, 3pole, 16 KA breaking capacity, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. (Make: L&T / BCH/ABB/LEGRAND).
Supply and fixing MCCB, 63 Amps, 3pole, 16 KA breaking capacity, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. (Make: L&T / BCH/ABB/LEGRAND).
Supply and fix Onload Changeover switch box type I-O-II for 400 Amps, 4 POLE, sheet steel Encloser, incld taking out old one complete all as specified & directed. (Make: L&T / BCH/ABB/LEGRAND).
Supply and fixing MCCB, 400 Amps, 4pole, 36 KA breaking capacity, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. (Make: L&T / BCH/ABB/LEGRAND).
Supply and fixing MCCB, 250 Amps, 4pole, 36 KA breaking capacity, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. (Make: L&T / BCH/ABB/LEGRAND).
M & L for silica gel complete all as specified and directed.
M&L for Decorative post top lantern for 360 degree , 40Watt, indirect light suitable for pipe 50mm dia including connection from connector to switch including taking down old one complete all as specified and as directed. Make - CG / Bajaj/Philips
M&L for LED street light made upof pressure die cast aluminium houseing with integrated polycarbonate lens,high power ceramic LED 70 watt, with IP66 protection,10kv SPD incld taking down old U/S fitting incld connection from connector to switch complete all as specified and as directed .Make- crompton, CG/Bajaj.
M&L PCC 1:3:6 type C2 type (using 40 mm graded broken stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
M&L for outdoor inverted pyramid tripod type bollard LED luminaries, 10 watt with IP 65 protection,including suitable size of wire from joint box to connector including taking down old unserviceable fitting complete all specified and directed. Make: CG/Havells /Bajaj/philips
Supply and fixing LED aviation light luminaires comprising of aluminium housing with polycarbonate enclosure, incl taking down old one complete all as specified and as directed. Make: CG/Havells /Bajaj/philips
M&L for GI strip 32 mm x 6mm as earth continuity conductor fixed to wall/burried in ground/drawn through conduit or pipe or fixed to pole for loop earthing complete all as specified and directed including taking out old one.
S&F Aluminium strip 25 x 3.15mm with porceline insulator and fixing screws etc. as roof conductors and down conductors complete all as specified and directed including taking out old one for work from 5th to 8th floor storey.
S&F Aluminium strip 25 x 3.15mm with porceline insulator and fixing screws etc. as roof conductors and down conductors complete all as specified and directed including taking out old one for work from 9th to 12th floor storey.
S&F Aluminium strip 25 x 3.15mm with porceline insulator and fixing screws etc. as roof conductors and down conductors complete all as specified and directed including taking out old one for work above 12th floor storey.
Supply & fix Air termination single pointed aluminum rod 12 mm dia and 300 mm long including taking down old unserviceable one complete all as specified and as directed.
Supply & fix Test point terminal block made of gunmetal or phosphorus bronze of size 75 x 75 x 25 mm, drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed including taking down old unserviceable one.
M&L for test point metal box of size 130 x 100 x 80 mm incl front cover and neoprene gusket with locking arrangement of 3mm thick CRCA steel sheet incl painting with powder coated on steel surfaces internally and externaly. Provision for Cutting two sides of box for inserting 32 x 6 mm earth strip incl taking down all as specified and as directed.
Attending emergency breakdown of where directed, Checking defective APFC panel board having low power factor, harmonics to achieve the power factor not less than 0.99 (small spares like MCB SP, pices of wire etc shall be deemed include in the quotaded rate) complete all as specified and as directed by Engr-in-Charge. Note : The item shell be operated maximum 2 times in entire period of contract in the same installation(s).
Supply only 15 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, complete all as specified and directed. (Make- L&T /BCH/ABB)
Supply only capacitor duty contractors of 15kvar rating, type MO C15 size Fr 1 complete all as specified and directed, (Make L&T / BCH/ABB).
Supply only capacitor duty contractors of 5kvar rating, type MO C5 size Fr 1 complete all as specified and directed, (Make L&T / BCH/ABB).
Supply only 20 KVAR rating reactor,heavy duty, lower operating losses,440 v,50Hz,complete all as specified & directed. (Make L&T / BCH/ABB).
Supply only 15 KVAR rating reactor, heavy duty,lower operating losses,440V, 50 Hz,complete all as specified and directed. (Make L&T / BCH/ABB).
Supply only MCB TP 63A, 415 Volt, 10 KA complete all as specified and directed. (Make L&T / BCH/ABB).
Supply only MCB SP 6A, 240 Volt, 10 KA complete all as specified and directed. (Make L&T / BCH/ABB).
Supply only cooling fan of size 4"(100mm), 2400 rpm, 230V omplete all as specified and directed.
Supply only 3 pole power contactors type ML-2, complete all as specified and directed. (Make L&T / BCH/ABB).
Supply only Volt meter (0-500 Volts) Indicating type(in built PT) complete all as specified and directed. (Make L&T / BCH/ABB).
Supply only Ammeter (0 - 100 A), Indicating type(in built CT) complete all as specified and directed. (Make L&T / BCH/ABB).
Material and labour for PVC cable end terminal boxes outdoor type, 30x20cm, PVC door, sintex box provision for cable incoming and outdoing from bottom, comprising of one MCB SP 6-32 Amps, cable glands suitable and one porcelein connector four way completed fixed on wall/pole with necessary clamps, screw etc all as specified and directed including taking out old one. (Make Sintex or equivalent of)
M&L for street light bracket made with 40mm dia medium grade GI pipe bended suitabely complete with primer and paint up 1.5M length complete all as specified and as directed.
M&L for PVC conduit pipe 20mm bore with necessary clamps for running of cable from junction box to street light fittings complete all as specified as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable unarmoured, with stranded copper conductor of size 1.5 sq mm ,3 core, 1100 Volts grade complete all as specified as directed. (for street lights connection from junction box to street light)
Repair/ maintenance of HT Oil Isolating switch(VLE) unit of 200 Amps capacity, 3 phase manually operated fixed/draw out ID type oil isolating switch 11KV/200A, MEI make at Teesta building by removing the breaker from panel discmantling carefully its parts/accessories. Cleaning the dust/impurities and accumulations etc blowering/brushing cleaning properly with CRC-26 spray to remove rust including supply of gasket, oil seal, nut & bolts, washers, reassembles, the parts /accessories and fix in same position and connection, testing for satisfactory operation all as directed. (Note: Maintenance /repairs shall be carried out by trained technicians/mechanic (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate)
INDIA ELECTRICAL EQUIPMENTS
MS HORIZEN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .