| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAdmitted-Finance | ₹2.2 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ASHISH ELECTRICALS L1 |
|---|---|---|---|---|
| 1.00P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. | ||||
| 1.01 | 185.0 Sq.mm 4 core | 2,000 | Mtr | 1,100 ₹22,00,000 Lowest |
| 1.02 | 70.0 Sqmm 4 Core | 3,223 | Mtr | 600 ₹19,33,800 Lowest |
| 2.00Replacement of following faulty items/ cnsumable items of DG Sets | ||||
| 2.01 | Oil Filter of 75/80 KVA DG Sets | 15 | Nos | 1,500 ₹22,500 Lowest |
| 2.02 | Diesel filter of 75/80 KVA DG Sets | 15 | Nos | 1,500 ₹22,500 Lowest |
| 2.03 | Lubricant OIL | 200 | Ltrs. | 250 ₹50,000 Lowest |
| 2.04 | 180 AH Lead acid battery | 10 | Nos | 14,500 ₹1,45,000 Lowest |
| 2.05 | coolent | 3,000 | Ltrs. | 195 ₹5,85,000 Lowest |
| 2.06 | Diesel | 600 | Ltrs. | 95 ₹57,000 Lowest |
Tender Value
₹2.4 Cr
EMD Value
₹2.4 L
Closing Date
16 Feb 2022, 6:00 pmClosed
ACE I RHB
Additional Chief Engineer-I, Rajasthan Housing Board Aawas Bhawan Jyoti Nagar Janpath Jaipur
Annual rate contract for Repair and maintenance of Electric works at different RHB Residential Schemes under ACE I RHB Jaipur
2022_RHBCE_256271_1
ACE-I_13/2021-22
Open Tender
Electrical Works
Percentage
365 days
Jaipur
As per NIT
3 documents required · 3 mandatory
₹3,540
As per NIT
₹2.4 L
Yes
2 Mar 2022
27 Jan 2022
21 Feb 2022
27 Jan 2022
16 Feb 2022
27 Jan 2022
Amount
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.
185.0 Sq.mm 4 core
70.0 Sqmm 4 Core
Replacement of following faulty items/ cnsumable items of DG Sets
Oil Filter of 75/80 KVA DG Sets
Diesel filter of 75/80 KVA DG Sets
Lubricant OIL
180 AH Lead acid battery
coolent
Diesel
Hire charges of Main service line for 3 phase connection upto 50 mtr. Length (without any joint) including meter board, panel/distribution Board and supports with skilled operator to operate system as and when etc as required. (If work contineue for more then one week , rates for next subsequent weeks will be 50% of the original rates.)
upto 25.0 sq.mm PVC insulated and Sheathed cable(Armoured or Un-armoured as required.)
Hire charges for Silent type D.G. Set, including change over switch. Control panel etc. and excluding POL with skilled operator to operate system as and when etc as required. of following capacity
Supply and filling of POL for DG sets
Replacement of existing transformer oil confirming to IS: 335 after removing of old oil and remove from site (old oil shall be retained by the contractor)
Charges for testing of transformer oil for its viscosity and dielectric strength including collection of sample from top and bottom of the existing transformer tank and submission of test report complete with all T & P , labour etc as required .
Charges for collection , Filtration and dehydration of existing transformer oil with the help of high vaccum filtration machine and cleaning of core-coil assembly by hot oil for removal of sludge / dust particles etc. as required.
Supply and filling of fresh transformer oil as per IS: 335 in existing transformer along with submission of oil test report for its physical and chemical properties.The oil shall be clear and free from any suspended matter or sediments complete as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Repairing of LT/HT bushings of Distribution Transformers includingreplacement of brass studs , porcelain insulators , nut bolts , oil seals , gaskets etc.complete as required complete in all respect. All as per pre approved byEngineer in charge. For additional technical parameters of products/ work refer annexure A
LT Bushing Set
HT Bushing Set
63 KVA to 500 KVA Set
630 KVA to 1600 KVA
Replacement of silica gel Breather of Distribution Transformers of following capacities complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Replacement of gasket of Distribution Transformers of following capacitiescomplete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
63 KVA to 500 KVA Set 1513
630 KVA to 1600 KVA Set
Providing experienced and Highly skilled/skilled/ semi- skilled/Un Skilled labour for electric repair/ maintenanceoperation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month)
Highly skilled Labour
skilled Labour
Semi skilled Labour
Hire charges for 90-150 Watt LED flood light luminairewith skilled operator to operate system as and when etc as required. (If work contineue for more then one day , rates for next subsequent days will be 50% of the original rates.
With suitable pole
With out pole
Detecting of cable fault for 33KV and 11 KV cable with fault locate Machine
Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps. Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. Certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of roduct/ accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
High Power LED Flood Light 150W
High Power LED Flood Light 200W
Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
LED Street Light fixture 30 Watt
LED Street Light fixture 70 Watt
LED Street Light fixture 120 watts
B-check servicing of 75/80/320 KVA DG set at Site i/c supply & replacing of mobile oil (Koel Care Super Genuine ) for B-check servicing as per manufacturer's recommendation (servicing is to be carried out through authorised dealer only).
Bidder Name
Amount
ASHISH ELECTRICALS(GSTN-08AHXPC7032J1ZZ)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.02 MB
tbid.pdf
Tender Documents • 11.32 MB
BOQ_457322.xls
BOQ • 0.33 MB
cagr.pdf
Tender Documents • 2.65 MB
gs.pdf
Tender Documents • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .