Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.0 LAccepted-AOC FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹54.7 L+₹1.1 L (2.09%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹68.3 L+₹14.8 L (27.6%)Rejected-Finance MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹58.8 L
EMD Value
₹1.1 L
Closing Date
6 Jun 2020, 6:00 pmClosed
SH M V SANKAR SE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO BUILDING NO P 49 ABHI I AT INS MANDOVI UNDER AGE I MANDOVI
2020_MES_341425_1
85255/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
AGE I MANDOVI
₹1.1 L
Yes
4 Sept 2020
28 Apr 2020
8 Jun 2020
28 Apr 2020
6 Jun 2020
23 May 2020
Amount
Schedule 'A' Part I - B/R portion
Taking down cement plaster of stone /PCC block /brick wall / top of chajja, or concrete surface of any description including raking out joints hacking for key securing down with water etc and removal of debris to outside of INS Mandovi Area complete all as specified and as directed.
Dismantling PCC floor,hearth or wall tiling including cement mortar bedding, removing serviceable tiles to stores and removing debris to a distance exc 250 m and not exc 1000 m spread and levelled all as specified and as directed.
Taking down chowkats with shutters without taking off shutters from the frames not exc. 1.5 sq m each all as specified and as directed.
Taking down chowkats with shutters without taking off shutters from the frames exc. 1.5 sq m but n exc 4 Sqm each all as specified and as directed.
Taking down steel tubing and connections 15 mm bore all as specified and as directed.
Taking down steel tubing and connections 20 mm bore all as specified and as directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level ) all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any portion not otherwise specifically provided for complete all as specified and as directed.
Demolition of brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, for ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling all as specified and as directed.
M&L for precast cement concrete block masonry type C1 1:3:6 using 20 mm graded stone aggregate with soild blocks exc 10cm in width and set in cement mortar 1:6 complete all as specified and as directed.
Dismantling/taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Fillig the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalant) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 part of water and allow to dry for 04 hours. Apply the first coat of waterproofing coating (Dr. Fixint Newcoat/ Waterseal Concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completly. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
M&L for providing 10mm thick plaster in cement mortar 1:3 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement. Note :- Integral water proofing compound shall be measured and paid separately
M&L for chipping , removing carefullly concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debries outside the premises etc. complete all as specified and as directed. Note : Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement with wire/rotary wire brush, making the surfaces free from loose material dirt etc, complete, applying two coats of alkaline rust converting primer FEOVERT confirming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as specified and as directed.
M&L for replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB complete all as specified and as directed.
M&L for carry out application of Bi-polar migratory corrosion inhibitor EPCO-KP-100/Protectsil CIT/Ferogard 903 on concrete surface (This inhibitor shall have migratory kind of properly which permits the material to migrate to a vertual extent of 100 mm, through pores of concrete , inhibiting the corrosion and de-passivating the Electro-chemical reaction. It should have properly to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete
M&L for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 mm center to center in staggered manner or as directed by Engineer-In-Charge.Work shall be carried out as under :- (i) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles: Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles: Cut the nozzles by chisel after completion of grouting without damaging structural elements.
M&L for injecting of site cement slurry grout, in the ratio 1:2 (1- Cement, 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kg of cement. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. (for repair to wall & slab)
M&L for injecting low viscosity MONOPOL (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including,Mixing of materials:Mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching.Grouting maintain the pressureat exit(0.5 to 1.0 kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements at 100ml per nozzle. Repeat the process for all the nozzles. (Beam and columns)
M&L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete
M&L for building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond,5 Cement,15 sand) -in damaged areas in 30mm thickness including leveling profliling etc complete all as specified and as directed.
M&L for providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor all as specified and as directed. Notes: (i)Reinforcement shall be measured and paid separately. (ii)Rates quoted for the item includes jacketing, formwork and micro concrete
M&L for 5 mm thick rendering in cement mortar 1:4 over gunniting / concrete surface and finished the surfaces even and smooth without using extra cement all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finish even & smooth with using extra cement all as specified and as directed.
M & L for 15 mm thick (10+5) rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces i.e first layer 10 mm thick and 5 mm thick outer layer mixed with WPC as per manufacturer's instruction and finished surface even and smooth without using extra cement complete all as specified and as directed. Note - WPC shall be measured and paid separately
Supply only WPC all as specified and as directed.
M & L for 5mm thick plastering in cement mortar 1:3 finished even & smooth, without using extra cement on ceiling all as specified and as directed.
M&L for applying two coats of Anti fungal weather proof paint over a coat of primer on newly plastered surfaces including preparation of surfaces all as specified and as directed.
M&L for complete removal of the existing surface treatment on wall & apply two coats of Anti fungal weather proof paint over a coat of primer including preparation of surfaces all as specified and as directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed.
M&L for preparing old plastered surfaces of ceiling and applying one coat of white wash all as specified and as directed.
M&L for preparation of newly plastered surfaces preparatory to distempering, priming plastered and other surfaces with alkali resistant priming paint, 1mm thick wall care putty & distempering walls with two coats of distemper oil emulsion, white or tinted all as specified and as directed.
M&L for complete removal of existing treatment for preparation of old plastered surfaces preparatory to distempering, applying two coats of distemper oil emulsion, white or tinted, over 1mm thick wall care putty all as specified and as directed.
M & L for 15 mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surfaces with liquid WPC as per manufacturer instruction complete all as specified and as directed. Note - WPC shall be measured and paid separately
Supply only liquid WPC all as specified and as directed.
M&L for 40mm thick cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate all as specified and as directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces all as specified and as directed.
M&L for broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and as directed.
M&L for 100mm thick cement concrete type B- 2, 1:2:4 using 40mm graded stone aggregate all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on vertical surface all as specified and as directed.
M & L for non - skid ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M&L for non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M&L for glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:3 for laying floor finishes for kota stone all as specified and as directed.
M&L for machine cut Kota stone slab 20-25mm thick as in riser of steps, skirting, dado and pillar cement laid over cement screed and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for polishing of existing kota stone flooring as mentioned in SSR part -I all as specified and as directed.
S & F CPVC 20mm pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S & F CPVC 25mm pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S & F in repairs stop valve of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms) in dia 15 mm pipe all as specified and as directed.
S & F in repairs bib tap standard of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms)15 mm bore pipe all as specified and as directed.
S&F in repairs pillar taps of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-110gms) 15mm bore dia all as specified and as directed.
S&F in repairs swivel shower of PTMT any colour for fixing with 15mm pipe (Minimum weight 40gms) & shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) all as specified and as directed.
S & F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) ( excluding flushing cistern and flush pipe) including seat and cover for pedestal pan all as specified and as directed.
S&F in repairs 10 litres capacity PVC valveless,syphonic action type,flushing cistern,low level,white with inlet,ball valve,float and handle including brackets & flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any all as specified and as directed.
Supply and fix in repairs vitreous china wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets & fixing wash basins, vitreous china (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe & flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for wash basin all as specified and as directed.
S&F waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45 gms) bore dia of discharge pipe of 32 mm all as specified and as directed.
Supply & fix vitreous china urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe all as specified and as directed.
S&F 5 litres capacity PVC valveless,syphonic action type,flushing cistern,low level,white with inlet,ball valve,float and handle including brackets & flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern & fixing only in repairs of High or low level fluslhing cistern, and connections to pipes and fixing of chain and pull, or lever, if any all as specified and as directed.
S&F PVC connection of size 15 mm ,450 mm long with PTMT nuts complete all as specified and as directed.
S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) all as specified and as directed.
S&F in repairs PTMT soap dish approximate size 160 x 160 x 90 mm embedded in wall all as specified and as directed.
S & F rotational moulded polyethylene water storage tanks 1000 Ltr capacity (Cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed.
Disconnecting existing tanks exc 250 litres & n exc 500 litres capacity ,setting aside cleaning and removing all scales and dirt etc from mouths of circulating pipes etc hoisting and refixing in position all as specified and as directed.
S&F in repairs ball valves 25mm bore dia high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 25mm-455gms) all as specified and as directed.
S&F 25 mm bore CPVC ball valve all as specified and as directed.
S&F 25 mm CPVC Tank Adaptor all as specified and as directed.
S&F 20 mm bore CPVC ball valve all as specified and as directed.
M&L for 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed.
M&L for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
S&F 110 mm dia PVC (SWR) pipe with single socketed in any length solvent cement jointed fixed to wall/column all as specified and as directed.
S& F PVC (SWR) bends any radius 110 mm bore all as specified and as directed.
S& F PVC (SWR) bends any radius 75 mm bore all as specified and as directed.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal 110mm all as specified and as directed.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal 75mm all as specified and as directed.
S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and as directed.
M&L for 75 mm thick cement concrete 1:3:6 type C1, using 20 mm stone stone aggregate as in plinth protection etc complete all as specified and as directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors (over plinth protection) with grey cement and no pigments all as specified and as directed.
S&F factory made panneled FRP door shutters, 30 mm thick with 2 mm thick FRP lamination top rail of size 25 X 150 mm, lock rail and bottom rail of size 25 X 150 mm with 12 mm thick panels of FRP sections of box type construction as per IS 4020 core shall be polyurethane foam/high density (more than 40 Kg per cubic meter) cellular foam done in situ and fixed in position as per manufacturer's instructions with and including the following fittings and as directed ( the thickness of FRP shutter and panels shall be inclusive of 2mm thick FRP lamination) Fittings to be provided per shutter Stainless steel 100 mm long butt hinge 03 Nos, Aluminium anodised 200 mm long barrel tower bolt 02 Nos, Aluminium anodised 150 mm size bow handles -02 Nos, aluminium alloy anodized sliding door bolt with hasp and staple (bolt type)-01 No all as specified and as directed.
S&F 100mm X 63 mm size factaory made FRP door frame, frame fixed with 3 Nos on either side with MS flat iron 25 mm x 3mm cut to size and made to swhape and fixed as in hold fast after necessary taring and sanding and fixed as per manufacture instruction and as directed. Thickness of FRP lamination shall be 2 mm. Core shall be polyurethane foam/high density (more than 40 Kg per cubit meter) cellular foam done in situ. Second class wooden blocks shall be provided to hold the fittings. The size of the chowkats shall be inclusive of 2 mm thick FRP lamination all as specified and as directed.
S&F powder coated Aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the JINDAL/HINDAL CO standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Notes :- 1.Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements. 2.Sheet glass & wire mesh shall be measured & paid separately
Supply and fix powder coated aluminium grill, 7.5 mm thick as per design code No. DG 007 of DURAL GRILL all as specified and as directed.
S&F 4 mm thick sheet glass panel aluminium window/ventilater, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane all as specified and as directed.
S&F figured glass 4mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified and as directed.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and as directed.
S&F in repairs 19 mm dia decorative aluminium anodized alloy curtain rod fixed with brackets all as specified and as directed.
S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
S&F factory made 2nd class hard wood 35 mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and as directed.
All as per item No 91 here in before, but 25mm thick wire gauzed Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, cla-use 8.24 (a); supplied and fitted to chowkats all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in bed plates , hold fast etc, all as specified and as directed.
S&F MS flat iron of size 25 x 3 mm as in hold fast, bands,straps, etc all as specified and as directed.
M&L for preparation of new wood surfaces & apply two coats of varnishing with synthetic varnish over a filler coat of wood filler liquid transparent, surfaces of any description over 10 cm in width or grith, not other wise description all as specified and as directed.
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and as directed.
S&F aluminium , anodized barrel tower bolt of extruded section & fixed 150mm long in size all as specified and as directed.
S&F extruded aluminium alloy handles, fabricated type, anodized 200 mm long in size all as specified and as directed.
S&F stainless steel hinge, size 100 mm all as specified and as directed.
S&F hand rails, half round or other stock section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
M&L for 2 coats of synthetic enamel painting over a coat of red oxide primer on new steel surfaces of any description, not otherwise described, over 10cm width or girth including preparation of new surfaces
Schedule 'A' Part II - E/M portion
Taking down carefully copper / aluminium point wiring ( Light,fan socket or power) complete including fitting and fixture such as switches,ceiling roses, pendants, regulators, socket, light fitting etc removing material to store for keeping in safe custody or for taking redit( credit for above item should be made as as per condition seperately) and making good disturbed surface of walls, floors ect complete all as per the existing finish.
Taking down DB TPN, Main Switch,Sheet metal enclosure all as specified and as directed.
Taking down submain wiring all as specified and as directed.
M&L for point wiring for one light point controlled by one switch with cable 1.5 sqmm copper cable in multistranded unsheathed through concealed in wall with PVC conduit with all accessories including pressed steel terminal boxes firmly fixed with pipe /wall and 3mm thick Hylem sheet or plastic masonite laqminated sheet top cover fixed with brass secrew for mounting switches sockets regulator etc all as specified and as directed.
M&L for point wiring for one ceiling/exhaust fan point controlled by one switch with cable 1.5 sqmm copper cable in multistranded unsheathed through concealed in wall with PVC conduit with all accessories including 1.5 sqmm cable conductor for earth wire including making connection with common earth dolly including pressed steel terminal boxes firmly fixed with pipe /wall and 3mm thick Hylem sheet or plastic masonite laqminated sheet top cover fixed with brass secrew for mounting switches sockets regulator etc all as specified and as directed.
All as per item No 106 here in before, but for switch socket combination 3 pin 5 amps on independent board all as specified and as directed.
All as per item No 106 here in before, but 2.5 sq.mm pvc insulated and unsheathed copper conductor for switch socket combination 3 pin 15 amps on independent board all as specified and as directed.
Supply and fix switch piano,flush type single pole ,one way 5 amp all as specified and as directed.
Supply & fix socket board comprising of 10 Nos.of 5 Amps sockets along with 10 Nos.of suitable piano switches complete with separate submain all as specified and as directed. NOTE:- Submain shall be of 4.0 sqmm copper cable along with 4.0 sqmm cable for earth
Supply and fix switch socket combination 5 pin 5 amp 230 volt 50 HZ AC all as specified and as directed.
S&F switch socket combination 05 pin 15 Amp 230 Volt all as specified and as directed.
Supply & fix fan regulator eletronic step type 300 watt all as specified and as directed. Make: Anchor Cat No- 38659 or equivalent in Bajaj/Usha
S & F ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed.
S&F LED tube light fitting 1 X 20 watt baton T5 CLASSIC integrated LED channel integral sleek extruded polycarbonate LED channel with white acrylic cover along with LED tube ROD 01 No including flexible wire three core from existing ceiling rose to fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and as directed.
Supply and fix in replacement including taking down u/s fittings and depositing to MES store Yard LED light 45 watt, IP 65, Die cast aluminium housing heat sink heat toughened glass individual LED 3 stage CCCV driver with min 4 KV surge protection voltage range of 150-270V AC and DC output operating voltage of driver should be complied to SELV norms connecting with 1.5 Sqmm 3 core cable aluminium stranded conductor from OH feeder/junction box to fittings as per site requirement complete all as specified and as directed. Make : BAJAJ BRTFG45W LED I or equivalent in Philips/Crompton.
Taking down ceiling fan of any make single phase and painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust and re- fixing again in same position all as specified and as directed.
S&F MCB 6-32 Amp 240 Volt single pole 'B' series all as specified and as directed.
Supply and fixing of MCB DP 32 Amp 230 Volt 50HZ AC supply all as specified and as directed.
Supply and fix MCB TPN 415 Volts 63 Amps 'B' series all as specified and as directed.
S&F sheet metal enclosure double door DB SPN 8 way 240 volts 50 Hz IP-42 protection all as specified and as directed.
S&F sheet metal enclosure double door DB SPN 4 way 240 volts 50 Hz IP-42 protection all as specified and as directed.
S&F MCB (DB) Vertical (TPN) 4 way double door 415 Volts complete including taking existing old unserviceable all as specified and as directed.
S&F consumer unit double door DBTPN 06 way with provision for MCCB as incommer 415 volts 50 Hz IP -42 protection all as specified and as directed.
Supply and fix MCCB 4 Pole,415 Volt fixed type , 125 amp with breaking capacity 16 KA all as specified and as directed.
S&F exhaust fan 300 mm sweep with louvers complete with suitable MS Bracket, nuts,bolts and fixing arrangement single phase 230/240volt AC supply 50 HZ including making holes and PCC work and including Taking down old u/s Exhaust fan of any size from the existing location and deposit to MES store yard all as specified and as directed.
M&L for submain wiring with 04 run of 6 sqmm single core copper cable PVC insulated unsheathed multistranded 1100 volt grade drawn through PVC conduit of suitable size with accessories etc concealed in wall/ceiling with and including two run of 6.0 sqmm single core copper cable run through concealed PVC conduit all as specified and as directed. NOTE :- Four run of 6 sqmm single core cable and 02 run of 6.0 sqmm single core cable as earthing contnuity conductor with PVC conduit shall be measured as one unit length meter
M&L for submain wiring with 02 run of 4.0 sqmm single core copper cable PVC insulated unsheathed multistranded 1100 volt grade drawn through PVC conduit of suitable size with accessories ext concealed in wall/ceiling with and including one run of 4.0 sqmm single core copper cable run through concealed PVC conduit all as specified and as directed. NOTE :- Two run of 4.0 sqmm single core cable and 01 run of 4.0 sqmm single core cable as earthing contnuity conductor with PVC conduit shall be measured as one unit length meter
Supply and fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly on ground earth pit n. less than 2.25 m deep below the ground bend with top edge of the plate n. less than 1.5m below ground level connected to GI earth wire 4mm by means of bolts,nuts,checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber cover and light grade GI pipe 40mm dia for protection of strip and fund etc complete all as per electrical plate No. 3 of SSR Part-I including connections with testing point of lightening protection all as specified and as directed.
Schedule 'A' Part III - External water supply
Excavation in trenches not exc 1.5m wide and n exc 1.5 m in depth and getting out in soft/disintegrated rock complete all as specified and as directed.
Returning filling in trenches including spreading levelling, watering and well raming in layers not exc 25 cm thick in soft/disintegrated rock all as specified and as directed.
Taking up or down GI/CPVC tubing and connecting including making good distrubed surface and removal from site all as specified and as directed for the following size:
(a)25 mm dia bore
(b) 50 mm dia bore
Supply & Laying of 25 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings such as elbow, bend, socket, nipple, union and Reducer socket etc fixed to wall, ceiling or floor all as specified and as directed.
All as per item No 134 here in before, but 50 mm outer dia CPVC pipe with all fittings fixed complete laid in trenches all as specified and as directed.
S & F in repair gun metal gate/globe valve with iron wheel screwed both ends for unions, pipes and fixed complete all as specified and as directed.
(a)25 mm bore dia of pipe
(b) 50 mm bore dia of pipe
M/s. R.S. LAWANDE
Super Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .