Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L1 | Accepted-AOC VALID | |
| 2 | L2₹9.2 L+₹19,370 (2.14%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹10.6 L+₹1.6 L (17.2%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹11.3 L+₹2.2 L (24.8%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
22 Oct 2020, 6:00 pmClosed
GE AF SURATGARH
GE AF SURATGARH
REPAIR TO INTERNAL WATER SUPPLY SANITARY FITTINGS TILLING AND OTHER MISC BR WORKS IN SMQ AND OTM ACCN IN ZONE B IN AKASH VIHAR AT AF STATION SURATGARH
2020_MES_380610_1
8820/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF SURATGARH
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
Yes
GE AF SURATGARH
₹20,000
Yes
1 Jan 2021
24 Sept 2020
24 Oct 2020
24 Sept 2020
22 Oct 2020
8 Oct 2020
Amount
BOQ (REPAIR TO INTERNAL WATER SUPPLY, SANITARY FITTINGS, TILLING AND OTHER MISC B/R WORKS IN SMQ AND OTM ACCN IN ZONE ‘B’ IN AKASH VIHAR AT AF STATION SURATGARH)
Demolition of cement concrete (un-reinforced) any description and laid in any position including removal of rubbish in low lying area, complete all as specified and directed by the Engineer in Charge.
Plain cement concrete (1:5:10), type E-2, using 40 mm graded mechanically crushed stone aggregates, as in filling of sunken floors, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:2:4), type B-1, using 20 mm graded mechanically crushed stone aggregates 75mm thick as in path/hardstanding in alternate ways, finishing the surface even & smooth with using extra cement, complete all as specified and directed by Engineer-in-Charge.
Rendering 20 mm thick on concrete surfaces of sunken foor in cement mortar 1:4 finished the surface even and smooth without using extra cement, mixed with WPC as per manufacturer instructions, complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified.
Taking up or down 15 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., and removal from site, complete all as specified and directed by the Engineer in Charge.
Taking up or down 20 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., and removal from site, complete all as specified and directed by the Engineer in Charge.
CPVC 16mm dia pipes SDR 11 and plain CPVC SDR 11 including necessary fitting (Brass elbow, Brass Tee, Union) on walls/ceiling or laying in floors complete all as specified by Engr-in-charge. Make-Apollo/Finolex/Astral
Steel water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed by the Engineer in Charge.
Re-fixing steel water tubing of 15 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified.
Re-fixing steel water tubing of 20 mm bore, with all fittings at new or old position, laid in floor along wall or at ceiling, complete all as specified.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit writing etc and making good, cutting exc 10cm and n exc 20cm girth complete all as directed by Engineer-in-Charge.
Dismantling of Cast Iron or reinforced concrete drain pipe, jointed in cement mortar and taking out of trenches, floors / walls if required upto 100mm internal dia of pipe complete all as specified and directed.
100 mm bore Cast Iron soil, waste and vent pipe, sand cast pipe, in any length, with or without ears, with cement joints in cement sand mortar 1:1 with spun yarn fixed to walls complete all as specified and directed.
75 mm bore Cast Iron soil, waste and vent pipe, sand cast pipe, in any length, with or without ears, with cement joints in cement sand mortar 1:1 with spun yarn fixed to walls complete all as specified and directed.
100 mm bore Cast Iron bend (any radius), diminishing piece or taper (larger bore measured) fixed as in repair, complete all as specified and directed.
75 mm bore Cast Iron bend (any radius), diminishing piece or taper (larger bore measured) fixed as in repair, complete all as specified and directed.
100 mm bore Cast Iron Tee/branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fixed as in repair, complete all as specified and directed.
75 mm bore Cast Iron Tee/branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fixed as in repair, complete all as specified and directed.
Cast Iron floor trap of size 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate), fixed as in repair, complete all as specified and directed by the Engineer in Charge.
PVC (SWR) pipes 110mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets fitting like bends, tee etc, fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
125 / 110 mm size PVC (SWR) gully trap, setting and jointing with solvent cement, fixed as in repair, complete all as specified and directed.
Stainless steel Plate Rack of best quality, made out of 0.80 mm thick stainless steel sheet , of size 90 cm x 60 cm x 25 cm with all internal fittings of appoved make, fixed as in repair, complete all as directed by the Engineer in Charge.
75mm wide 4mm thick rubber bidding for aluminium /wooden door seal with brush fixed to door shutter with nails, fixed as in repair, complete all as directed by Engineer-in-Charge.
Waste coupling PTMT of 32mm dia with long screwed shank and fly nut for for WHB/Sink, fixed as in repair, complete all as specified and directed by the Engineer in -Charge
Stop valve 15 mm dia cast copper alloy , angular decorative fancy type chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair , complete all as specified and directed by Engineer-in-Charge.
Pillar taps, 15 mm bore cast copper alloy chromium plated fancy type, with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe fixed as in repair, complete all as specified and directed by the Engineer in Charge.
Bib taps fancy type chromium plated ,15 mm cast copper alloy with crutch handle or butter fly handle screwed down, screwed for iron pipe and fixed as in repair, complete all as specified and directed by the Engineer in Charge.
Bib tap, 15 mm size, standard of PTMT, any colour high pressure screwed for iron pipes (minimum weight 90 gram) fixed as in repair, complete all as specified and directed by the Engineer in Charge.
Chromium plated brass shower rose 125 mm bore of rim with swivel joint fixed as in repairs ,fancy type suitable for 15 mm bore pipe including shower arm chromium plated 15 mm dia, 195 mm long with bend of 45 degree including fixing to steel pipe or union ,complete all as specified and directed by Engineer-in-Charge
Ball valve of 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) & fixed in repairs , complete all as specified and directed by Engineer-in-Charge.
Wash basins, vitreous china, white, flat back of size 550x400 mm with pedestal including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe and including new brackets fixed as in repair , complete all as specified and directed by the Engineer in Charge. Make :- CERA/HINDWARE/PARYWARE.
Vitreous china squatting pan Orissa pattern size 580x440mm white with integral foot rest (exclusive flusing cistern& flush pipe) including cast iron 'P' or 'S' trap of 100 mm bore pipe fixed in PCC 1:2:4 type B-2 and necessary lime concrete, fixed as in repairs, including making good the surface to match with existing floor finish fixed as in repair ,complete all as specified and directed by the Engineer in Charge. Make :- CERA/HINDWARE/PARYWARE.
PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level fixed in repair , complete all as specified and directed by the Engineer in -Charge
PVC connection of PTMT ,non corrosive with nuts and washers on both ends, 450mm long suitable for 15 mm bore fixed in repair , complete all as specified and directed by the Engineer in -Charge
PVC waste pipe 32mm dia socketed and 600mm long for WHB /sink fixed in repair, complete all as specified and directed.
Stainless steel sink made of 1.00 mm thick sheet for kitchen with plugs washers & wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495 mm x 420 mm with bowl size 410mm x 330mm x 160mm, with and including PVC waste pipe and CP waste coupling 32 mm fixed as in repair and making good to disturbed surfaces, complete all as specified and directed . Make : Nirali/ blue star or equivalent.
Stainless steel sink made of 1.00 mm thick sheet for kitchen with plugs washers & wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm with bowl size 410mm x 330mm x 160mm, with and including PVC waste pipe and CP waste coupling 32 mm fixed as in repair and making good to disturbed surfaces, complete all as specified and directed . Make : Nirali/ blue star or equivalent.
Glass shelf assembly consisting 5.5 mm thick, 12mm wide and 600mm long chromium plated plated bracket guard and railing, fixed as in repair , complete all as specified and directed by the Engineer-in-Charge. Make - MARC/GEM /PRIMA/ESS ESS .
Grating round 100mm size of PTMT (minium weight 50 gram) fixed in repair , complete all as specified and directed by the Engineer in -Charge.
Wash hand basins, counter type, vitreous china white, oval shape of size 440x525x195mm including 32mm dia waste coupling, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe fixed as in repair , complete all as specified and directed by the Engineer in Charge. Make :- CERA/HINDWARE/PARYWARE.
Vitreous china bowl urinal (half stall)flat back or corner wall type fixing, bedding urinal against wall in cement mortar 1:2 including pointing around urinal back with cement motrar, with grating and union for discharge pipe, including urinal spreader for fixing with 15 mm dia pipe, fixed as in repair, complete all as specified and directed by the Engineer in charge. Make :- CERA/HINDWARE/PARYWARE.
Vitreous china urinal partition white of size 310x700 mm, fixed as in repair, complete all as specified and directed by the Engineer in charge.
Vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts flushing cistern and flush pipe) including plastic seat cover white and mild steel chromium plated aluminum hinging devices, connected to drains outlet, fixed as in repairs,complete all as specified and directed by the Engineer in Charge.
Dismantling floor, hearth or wall tilling including cement morter bedding (but not backing ),and removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed by Engineer-in-Charge
First quality glazed ceramic coloured tiles of (350x250mm) x 7 to 8 mm (450x300mm) x 7 to 8 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles ,complete all as specified and directed by the Engineer in Charge.
First quality glazed ceramic coloured tiles of (300x200mm) x 7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:4) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles ,complete all as specified and directed by the Engineer in Charge.
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sq.m but not exceeding 0.11 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles,complete all as specified and directed by the Engineer in charge.
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in coloured cement to match the shade of tiles,complete all as specified and directed by the Engineer in charge.
Granite (any type) 14-16 mm thick, work (table rubbed and polished) in steps, windows cills, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed of 15 mm thick in CM 1:4, complete all as specified and directed by the Engineer in Charge.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description not exceeding 1.50 Sq. m each, and making good the disturbed Surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
Taking down Chowkhats with shutters without taking of shutter from the frame of any description exceeding 1.50 Sq. m but not exceeding 4.00 Sq. m each, and making good the disturbed Surface in CM 1:4 & finished with similar specification as exists, complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description exceeding 1 Sq. m but not exceeding 2 Sq. m each, from chowkhat, complete all as specified and directed by the Engineer in Charge.
Mild steel framed work such as in doors/chowkhats or gates of angle or other section with gusset plates, rail, braces etc. complete drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fittings (exclusive of steek sheeting or other coveriong, running rails and guides) and hanging, also fastening & fixing and similar work conforming to Fe-290 grade E-165 , complete all as specified and directed by Engineer-in-Charge
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted as per specification & drawing and as per manufacturer's instructions and shown on drawing on Page 160 of SSR Pt-II ,complete all as specified and directed by the Engineer in Charge.
Factory made solid panel PVC Door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail,lock rail and bottom rail on either side as gap insert for top rails, bottom rail,panelling of plain colour PVC sheet to be fitting in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supply & fixing in the frame at site as per specification and drawing on Page No 156 of SSR Part-II Rates,complete all as specified and directed by the Engineer in Charge.
Aluminium handles cast type anodised of 150mm size , complete all as specified and directed by Engineer-in-Charge.
Aluminum anodizes barrel tower bolts of extuded section and fixed of 150 mm ong size (length of bolt), complete all as specified and directed by Engineer-in-Charge
Butt hinges medium weight stainless steel of 100 mm size and fixed, complete all as specified and directed by the Engineer in Charge.
Steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge
Steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-Charge
Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed by Engineer-in-Charge
Preparing new steel surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified and directed by Engineer-in-Charge.
Preparation of old steel or iron surfaces over 10 cm width or girth not other wise described and applying one coat of synthetic enamel paint (of approved shade), complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling our glazing pins / spring clips providing and fixing new one , complete all as specified and directed by Engineer-in-Charge.
Sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and directed by the Engineer in charge.
Frosted sheet glass 3 mm thick, ordinary quality and glazing with oil putty (in metal frames etc) in squares not exceeding 0.5 Sq. m in each pane, complete all as specified and directed by the Engineer in Charge.
Stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.4mm & fixed with tinned tacks, or stainless steel wire staples, complete all as specified and directed by Engineer-in-Charge.
Stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.4mm & fixed with tinned tacks, or stainless steel wire staples, fixed as in repair, complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches , pillars etc & removing debries out of MoD land, complete all as specified and directed by the Engineer-in-Charge.
Brick work with sub class 'B' , straight or curved on plan not exc 6m mean raidus built in cement mortar 1:6 , complete all as specified and directed by Engineer-in-Charge.
Brickwork with sub class 'B' bricks , straight or curved on plan not exc 6m mean raidus (except brick) built in cement mortar 1:6 , complete all as specified and directed by Engineer-in-Charge. Note: Servicable bricks retrived from serial item No 71 above shall be used after proper cleaning and washing of old bricks.
Taking down cement plaster on brick walls or stone wall including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish in low lying area ,complete all as specified and directed by the Engineer in Charge.
Rendering 10 mm thick on RCC ceiling surfaces in cement mortar 1:3 and finished the surface even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
Rendering 10 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 finished the surface even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 finished the surface even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered wall surfaces and applying two coats of exterior acrylic emulsion paint (wheather proof) in camouflaging patterns (in multi colour shades as approved) over and including one coat of primer (antifungal), complete all as specified and directed by the Engineer-in-Charge.
Preparation of old surfaces of walls including scraping by mechinised means (Vacuum based sanding machine); scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and washing with water and applying two coats of exterior acrylic emulsion paint (antifungal), (in camouflage pattern using number of colours), complete all as specified and directed by the Engineer-in-Charge.
Preparation of new wall surfaces and applying two coats of oil bound distemper (white or coloured) by auto roller over and including 2mm thick Birla / JK wall care putty to obtain smooth regular/ even finish by using sand papercomplete all as specified and directed by Engineer –in-Charge.
Preparation of new surfaces of ceilings and applying three coats of white wash, complete all as specified and directed by Engineer –in-Charge.
Preparation of old surfaces of ceilings including scraping by mechinised means (Vacuum based sanding machine); scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and washing with water and applying two coats of white wash, complete all as specified and directed by Engineer –in-Charge.
Plain cement concrete 1:2:4 type B-0(12.5 mm graded stone aggregate) 25mm thick as flooring finished fair & even to receive top layer of flooring , complete all as specified and directed by Engineer-in-Charge.
75 mm thick, plain cement concrete 1:3:6, type C-1, using 20 mm graded mechanically crushed stone aggregates, laid in 1:30 slope as in plinth protection , surface finished even and smooth without using extra cement, complete all as specified and directed by the Engineer in Charge. Note: (i) Plinth protection shall be laid to slope (1 in 30) in alternate bays not exceeding 3 mtr in length with joint of 6mm wide and 10mm deep shall be provide along the wall and bays and shall be filled with sealing compound grade 'B'. (ii) Cost of sealing compound is included in the unit rate of the item.
Dismantling existing water storage tanks exc 250 litres but n.exc 500 litres capacity by disconnecting existing water connection and removal from site , complete all as specified and directed by Engineer-in-Charge
Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve, complete all as specified and directed by Engineer –in-Charge.
Ball valve of 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) & fixed in repairs , complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre deep in soft/loose soil for foundations etc. or for cesspits etc. or for manholes not exc. 10 Sq. m on plan and not exc. 1.5 metre in depth or for shiftling existing sewage lines and getting out , complete all as specified and directed by the Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, in soft/loose soil, complete all as specified and directed by the Engineer-in-Charge.
Removing excavated material to distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed by the Engineer-in-Charge.
Plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by the Engineer-in-Charge.
Salt- glazed stoneware drain pipe grade ‘A’ 150 mm bore, ISI marked jointed with cement mortar, laid in trenches and tested including pipe fittings such as bend, junction etc. of same grade, complete all as specified and directed by the Engineer-in-Charge.
Cutting into walls of existing manholes for connecting new drain pipe 150mm dia bore, making good to wall in CM (1:3)/ PCC (1:2:4) after inserting pipe, cutting out benching & forming branch channel in cement concrete (1:2:4) type B-1, reforming benching as required and rendering smooth finished, including removal of rubbish outside MoD land, complete all as specified and directed., complete all as specified and directed by the Engineer-in-Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates, filling in mass concrete, foundation and as in sub base of flooring, complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position, complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 8mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S, complete all as specified and directed by Engineer-in-Charge.
Precast reinforcement cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate in man holes covers slabs/Shelves as in slabs supported on walls, beams and columns, in floors, roofs, landings, deck slabs and in shelves and like including necessary form work as in repair,complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate as in Surface channels and drains & likes , complete all as specified and directed by Engineer-in-Charge.
Forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitered / stopped ends etc. complete all as specified and directed.
Plain cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate as in coping, bands etc like incl weathering, slightly rounded or chamfered throating as directed incl form work (straight or curved) and finish all exposed surface facing of concrete , complete all as specified and directed by Engineer-in-Charge.
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 15 (R) of tender documents.
M/S Shree Ram Enterprises
MSR INFRATECH
M/S VISHNU ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .