Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance M S OMVEER SINGH CONTRACT OR AND ENGINEERS VILLAGE NASRATPUR SAHARANPUR UTTAR PRADESH 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | Admitted-Finance |
| 3 | Admitted-Finance GRAM POST MAWANA KHURD MAWANA MEERUT | MEERUT | UTTAR PRADESH | 245206 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
24 Apr 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Distribution Circle II Saharanpur
WORK OF FULL DIPOSIT SCEEM TOWN OF EDD NAKUR
2021_PVVNL_573804_2
03/W/EDC II/SRE/2021-22
Open Tender
Electrical Works
Lump-sum
365 days
SAHRANPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC II SRE
₹2,000
Yes
18 May 2021
13 Apr 2021
24 Apr 2021
13 Apr 2021
24 Apr 2021
13 Apr 2021
120 days
Amount
Detail of Work
Safe cartage of PCC/STP poles up to 11 Mtr. from ESC, SRE/JE store to site of work at various sites including loading & unloading at both ends.(Dist.Up to 50 Km.)
Safely cartage of other complete line material (Except PCC /STP Poles) from ESC, SRE JE store to site of work at various sites including loading, unloading at both ends.( Dist.App. 0 to 50 Km.)
Safe cartage of 25/250 KVA T/F from ESC,SRE/JE Store to the site of work including loading & unloading at both ends. (Dist. Upto 50 km.)
Erection of single support on PCC/STP poles up to 11 Mtr Long with complete fitting of all accessories of 11 KV/LT line.as per RESPO specification.
Erection of double on PCC/STP poles up to 11 Mtr Long with complete fitting with all accessories as per RESPO specification.
Fixing of 11 KV stay rods by digging of pits in block of 600X600X300 mm. & with new brick and nozzling of stay wire 7/10 SWG and fitting the same on the pole
Providing & fixing of LT clamp with nuts bolts made of new MS flat iron 50x6 mm on PCC poles as per RESPO specification.
Providing of LT shekel insulator of size 100x115mm
Providing of nuts & bolts for LT shekel insulator of size 180x19mm half threading.
Providing & fixing of X-arm holding clamps PCC/STP poles with nuts bolts made of new MS flat iron 50x6 mm as per RESPO specification.
Providing & fixing of F-brackets PCC/STP poles with nuts bolts made of new MS flat iron 50x6 mm on PCC/STP poles as per RESPO specification.
Providing & fixing of double Pole clamp on PCC/STP poles with nuts bolts made of new MS flat iron 50x6 mm on PCC/STP poles as per RESPO specification.
Opening of consumer cable connections for LT line then sagging, binding, jumpering and reconnection of cable of consumer.
Laying, lifting, Stringing, sagging jumpring & binding of ACSR Weasel/Rabbit Conductor for 11KV/LT Line as per RESPO specification including complete.
Laying, lifting, Stringing, proper sagging ABC cable of size 3x95+1x70+1x16sq.mm. including fixing of all accessories.
Earthing of poles by earthing rod as per RESPO specification.
Removal of 250 KVA T/F from the existing D/P after opening HT & LT connection and with shifting the T/F from the site to ESC, SRE/JE store with loading & unloading at both ends.
Safe installation of 25/250 KVA T/F on the double pole with complete fittings including making connections and commissioning.
Construction of plinth for installation of 250 KVA T/F of size 1.5x1.5x1.5 Mtr. made of 9" thick wall in all the four sides with 6" thick RCC top duly filled with sand & plastered 12 mm. thick in ratio 1:4 with cement & sand on outer surface of brick wall .
Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning.
Laying and making connections of LT PVC/XLPE cable 3.5x70sq.mm./3.5x150/1x240 sq.mm. from T/F to double pole (approx to 20 Mtr).
Making of Brakets with M/S Channal and MS angel complete work.
Earthling of T/F of 250 KVA of boring 60ft deep and fixing of 60ft GI pipe 1.5 inch dia class b and connecting with GI strip of size 40*5 mm at the bottom of GI pipe to the t\f with providing of required charcoal and salt in the pipe.
Off shooting of tree branches touching the 11 KV/LT line.
Replacement of broken/damaged pin insulators
GYAS PAL CONTRACTOR
SHIV CONTRACTOR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .