Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹20.9 L+₹1.3 L (6.76%)Rejected-Finance | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹21.2 L+₹1.7 L (8.54%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹22.2 L+₹2.7 L (13.6%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | Rejected-Technical | - | Rejected-Technical Not meeting in eligible creteria |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
20 Aug 2020, 6:00 pmClosed
GE MH AND RH Kirkee
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINT OF EXTERNAL ELECT SUPPLY NETWORK INCL REPLACEMENT OF OLD US LT CABLE PANEL AND ITS CONNECTED ITEMS AT AUNDH MIL CAMP UNDER GE MH AND RH KIRKEE
2020_MES_362768_1
8126/E8
Open Tender
Civil Works
Works
270 days
Kirkee and Aundh
As per NIT
6 documents required · 6 mandatory
₹500
GE MH RH KIRKEE
₹50,000
Yes
16 Sept 2020
22 Jul 2020
21 Aug 2020
22 Jul 2020
20 Aug 2020
6 Aug 2020
22 Jul 2020 - 29 Jul 2020
Amount
Excavation in trenches for taking out/laying of Cable not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in soft/loose soil Complete and all as specified.
All as par item No 1 above but in hard dense soil
Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each layer of soft/loose/hard/dense soil complete and all as specified.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. Complete and all as specified.
M & L for riddled earth for cushioning including spreading, levelling and hand punning to under ground cable in trench all as specified and directed. Note: Punned thickness shall only be measured and paid.
M&L for brick protection with sub class B bricks all as specified and directed.
Labour only for relaying old retrived brick/PCC cable cover during excavation of old unserviceable UG cable of any size
M&L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 10 sqmm 2 core including aluminium cable gland,suitable end terminations with Aluminum lugs at both cable ends all as specified and directed
All as per item No. 10 here-in-before but 10sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 16sqmm 4 core complete all as specified
All as per item No. 10 here-in-before but 25sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 35sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 50sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 70sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 95sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 120sqmm 3.5 core complete all as specified
All as per item No. 10 here-in-before but 150sqmm 3.5 core complete all as specified
Taking down underground serviceable LT cable from trenches all as specified and as directed.
Relaying of serviceable LT underground cable obtained form above items in trenches etc all as specified and as directed.
S&F in replacement of old broken/worn out steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long). Note : Excavation and earth work and PCC will be measured and paid separately.
Supply and fixing cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complete all as specified and directed.
S&F ACSR conductor incl jointing with existing conductor and stringing on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as dercted
Dimantling and taking down old/unsv insulator of any type any size from pole/stay carrying to store for credit complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed.
S&F shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
S&F Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm all as specified and directed.
M&L for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismantling unsv one all as specified and directed. Note: Clamps, loop insulator, earth work and PCC will be measured and paid separately.
S&F for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismantling taking down unserviceable one all as specified and directed
S&F cradle hexagonal /rectangular fabricated with galvanised steel wire not less than 4mm dia on pole incl dismentling taking out unsv cradle guard all as specified and as directed.
S&F earth continuity wire using GI wire not less than 4mm dia on pole incl dismentling taking out unsv GI wire all as specified and as directed.
M&L for earthing with galvanised steel earth plate electrode 60cm x 60 cm x 3.15 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 mtr below ground level connected to and including testing point and GI strip of size 32 x 6 mm 7.5 mtr beyond the earth pit as earthing lead including GI protection pipe 40 mm bore (light grade) burried in ground at a depth of 300 mm upto 7.5 mtr beyond the earth pit and connecting to equipments by means of earthing lead , GI bolts, nuts & washer etc with provision of char-coal and salt etc all as per electrical plate No 3 of SSR Part - I, 2009 including RCC cover and MS angle iron frame watering arrangements with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc complete all as specified and directed by Engr-in-charge. Note : Rate of item is deemed to be included for excavation in hard rock, by compressor machine to achieve required depth.
Labour only for restringing of overhead ACSR conductor of any size includign cradle gaurd / GI earth wire on pole after disconnecting all jumpering connection & binding of insulators and including rejointing all jumper connections and insulators, binding with aluminium conductor providing required T&P all as specified and directed
Supply and fix of LT outdoor type feedar pillar box confirming to IS 8623 with IP-54 protection of minimum size (750x750x250)mm made out of 3.15 mm thick CRCA sheet with both side openable door with locking arrangement and complete panel should be powder coated with having neoprene rubber gasket for sealing door, doors of the panel should be removable type, including Al bus bar of suitable size and capacity as per site requirement complete all as specified and directed by Engr-in-Charge. Note : Aluminium Bus Bar shall be measured separately under relevant item of Schedule A.
Supply only Heat shrink straight through joint LT 1100 volts grade 10-25 sqmm, 4 core, Make-3M or equivalent of M-Seal/MS Seal/Rayhem
Supply only Heat shrink straight through joint LT 1100 volts grade 35-50 sqmm, 3.5/4 core, Make-3M or equivalent of M-Seal/MS Seal/Rayhem
Supply only Heat shrink straight through joint LT 1100 volts grade 70-95 sqmm, 3.5 core, Make-3M or equivalent of M-Seal/MS Seal/Rayhem
Supply only Heat shrink straight through joint LT 1100 volts grade 120-185 sqmm, 3.5 core, Make-3M or equivalent of M-Seal/MS Seal/Rayhem
Supply and fixing MCCB, 4 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps, incl dismentling taking down unsv one, make- Schneider/ABB/Legrand/Merlin Gerin.
Supply and fixing MCCB, 4 pole, 36 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismentling taking down unsv one, make- Schneider/ABB/Legrand/Siemense
Supply and fixing MCCB, 4 pole, 16 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps, incl dismentling taking down unsv one, make- Schneider/ABB/Legrand/Merlin Gerin.
Supply and fixing MCCB, 3 pole, 16 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 25 to 100 Amps, incl dismentling taking down unsv one, make- Schneider/ABB/Legrand/ Siemense
Supply and fixing MCCB, 3 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 160 amps, incl dismentling taking down unsv one, make- Schneider/ABB/Legrand/Siemense
Supply and fixing MCCB, 3 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 200 amps, incl dismentling taking down unsv one, make- Schneider/ABB/Legrand/Siemense
Supply and fixing MCCB, 3 pole, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 250 amps, incl dismentling taking down unsv one, make- Schneider/ABB/Legrand/Siemense
Supply only GI tubing light grade 40mm bore, ISI marked, for cable protection
Supply only GI tubing light grade 50mm bore, ISI marked, for cable protection
Supply only GI tubing light grade 80mm bore, ISI marked, for cable protection
M&L for painting to steel surfaces of gate, rolling shutter, fencing, LT panel boards, over 10cm in width or girth,not otherwise described with synthetic enamel paint (ordinary tint) one coat as per specified colour code including writing letters or figure n exc. 30 cm high on LT/HT poles indicating substation number and serial pole number using white synthetic paint on black synthetic paint as background and on Transformer body showing SM/MES No and on LT panel board showing feeder/location using black synthetic enamel paint all as specified and directed.
M&L for painting with two coats of aluminium paint including preparation of old painted surfaces of poles of 9 mtr long LT steel tubular poles/street light pole complete with fittings, brackets, cross arms complete all as specified and directed by Engr-in-charge.
M/L for trimming of branches of trees of grith not more than 50 mm touching LT electric over head line and making clear about 3 mtr in radius with suitable T & P carrying and depositing where directed not exceeding 50 mtr all as specified and as directed.
S&F rigid PVC line separator suitable for 2 wire, made from high grade PVC material, distance but phase to phase 300mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast
M & L for taking down unserviceable conventional street light fitting and S & F Energy saving DPSD Dimmable LED Street light 60 W, with dimming optins of 30% / 50% / 70% at pre-determined time slots. Various dimmable, Housing made from cast aluminium toughened glass, IP 65, complete & wired with all accessoires. Make: Shati Cat No: SZPSLMM060DIM or equivalent make & model of Wirpro/Jaguar
M&L for wiring for circuit/submain wiring along with earth wire with two run of 2.5 sqmm, one run of 2.5 sqmm sizes of FRLS PVC insulated copper conductor through conduit from pole mounting box to light fitting. Note:- (i) Two run of 2.5 sqmm cable and one run of 2.5 sqmm cable measured as one length.
Supply and fix sheet moulding compound(SMC) Junction box size 250 x 200 x 105 mm inner dimension, Hinged door, including three phase 100 Amps 4 pole baklite terminals and MCB SP 2 Amps for street light control mounted on pole with the provision of cable entry and exit. Make: sintex or equivalent
Material and labor in existing panel board / timer box Contactor of capacity 25 to 50 Amps 3 Pole, coil voltage as per site requirement with street light timer relay including taking down old all as specified and as directed.. Make : L & T,Siemense, ABB, Legrand
Material and labour for Switch fuse unit of 415 Volts, capacity 32 to 100 Amps including taking down old all as specified and as directed Make : L & T,Siemense, ABB, Legrand
Material and Labour for Change over switch 63 Amps 415 Volts with enclosure including taking down the same all as specified and as directed
S&F rigid PVC line separator suitable for 4 wire, made from high grade PVC material, distance bet phase to phase 300mm, suitable for use with 1100 volts grade all as specified and as directed. Make- Shree Balaji Power Plast/Goyal Power Plast
M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) of 150 x300 mm in respect of width and depth complete all as directed by Engr-in-charge
Descaling of LT indoor/outdoor Panel/feeder pillar box any type by disconnecting and removing all the incoming and outgoing cable connection from MCCBs, cleaning of dust with air blower, burnt busbars, burnt thimbles, any type of insulators, cable tray, sprial piping, necessary cable tie, reconnections after proper cleaning of contacts with CRC solution and fixing of hanging front and rear openings with new hinges including welding as required painting of complete panel including stand and door/back outside(after proper scrubbing) with synthetic enamel paint one coat as per specified colour code including writing of panel/feedar panel location using black systhetic paint and reconnecting the dismantled LT cables etc. complete all as specified and directed by Engr -in- charge. Note :(i) Cost of labour, cotton waste and T&P required for upkeeping/maint work is inclusive in quoted rate.
Supply only RYB indicator lamp LED type for incoming and outgoing supply as per Existing size all as directed by Engineer-in-Charge.
S & F coarse aggregate grading 3, 50 to 20 mm size spread in substation / surronding of outdoor Panel / below GOD as specified and directed by Engineer - in - charge
Taking down and M & L for 32mm X 6mm galvanised iron strip earth continuity conductor including nut bolt GI washers etc or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.
Taking down and M & L for 25mm X 4mm galvanised iron strip earth continuity conductor including nut bolt GI washers etc or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.
Taking down and M & L for 25mm X 3mm Aluminum strip earth continuity conductor including nut bolt GI washers etc or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.
M & L, for L.T. lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 volts including taking down the unserviceable LA all as directed.
M & L Air termination, single pointed aluminium rod 12mm dia and 300mm long including taking down including dismantling the broken rod all as directed.
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, porcelene insulator aluminium strip 100 X 25 X 3 mm or GI nut bolts washers etc. incl taking down the unserviceable block all as specified and as directed.
Taking down and refixing of Aluminium / GI strip including new GI nut bolts washers, fastner bolt, porcelene insulator etc.
MAYUR ELECTRIC SERVICES
SKS Electricals
metro electrical services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .