Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.1 L+₹7,269 (0.66%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹11.1 L+₹12,586 (1.15%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹12.9 L+₹1.9 L (17.2%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹14.5 L+₹3.6 L (32.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
6 Aug 2021, 6:00 pmClosed
GE (I) (P) Fy Jabalpur
GE (I) (P) Fy Jabalpur PO - Khamaria PIN - 482005
PROVISION OF NEW STORE ROOM, TANK FIRING PLATFORM, RETAINING WALL AND RCC SAFETY WALL AT EAPL GUN POINT AT TECH AREA TAKU, CPE ITARSI UNDER GE (I) (P) FY JABALPUR
2021_MES_457029_1
8399/ITA/E8
Open Tender
Civil Works
Item Rate
240 days
Itarsi
As per eNIT
6 documents required · 6 mandatory
₹500
GE (I) (P) Fy Jabalpur
₹26,000
Yes
29 Oct 2021
5 Jul 2021
12 Aug 2021
5 Jul 2021
6 Aug 2021
23 Jul 2021
Amount
Surface dressing n exc 15 cm deep in soft /loose soil all as specified and directed.
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth, for foundation, etc orfor shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out in any type of soil all as specified and directed.
All as per item No. 02 here-in-before but exc 1.5m & n exc 3.0M all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exe 25 CM all as specified and directed.
Removing excavated materials n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point all as specified and directed.
M&L for plain cement concrete type D2 1:4:8 using 40 mm graded stone aggregate as in foundation filling and mass concreting and sub base for floor all as specified and directed.
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded stone agg) nominal mix as in foundation including raft, footings, basement slab and mass concrete all as specified and directed.
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded stone agg) nominal mix as slabs supported on walls, plinth beams and columns in floors, roofs, landings, balconies all as specified and directed.
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded stone) nominal mix for Columns, pillars, piers, posts all as specified and directed.
M&L for reinforced cement concretetype B1 1:2:4 (20 mm graded stone) nominal mix for Lintel Beam, roof beam, Gebal beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded stone) nominal mix for Chajjas all as specified and directed.
M&L for form work to sides of concrete foundation, footing bases of columns raft and similar work vertical or to batter for rough finished curved surface all as specified and directed.
M&L formwork to sides and soffits of floor or roof beam, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc including fair finished surface all as specified and directed.
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal including fair finished surfaces all as specified and directed.
M&L formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick all as specified and directed.
Mild steel TMT bars of Fe - 500 10 mm dia and over cut to shabe required including cranking bending spirally hooping for columns hooking ends and binding with and includuing mild steel wire (anneled) not less than 0.9 mm dia all as specified and directed.
All as per item No. 16 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed.
Material and labour for brickwork with subclass 'B' bricks straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as speciified and directed.
Material and labour for Brick work with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick wall built in CM 1:4 complete all as specified and directed.
M&l for rendering 15 mm thick on fair faces of brick wall mixing with water proofing compound as per manufacturer instruction (Water proofing compound paid for seperately) of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement.
Supply only intregal water proofing compound.
M&L preparation of newly plastrered surface of any description and applying two coat of Cement Base paint all as specified and directed.
M&L preparation of new surfaces of wall and applying three coats of white washing to wall surface complete all as specified and directed.
Material and labour for providing precast cement concrete type B-l, 1:2:4 (20 mm graded aggregate) for slab set in cement mortar (1:4) as in bench complete all as specified and as directed.
Excavating over areas, n exc 1.5m deep and getting out hard/dense soil complete all as specified and as directed.
M&L Hard core of Broken stone Boulders of gauge n.exc 63mm deposited spread & levelled in layers n exc 15cm watered and rammed to a true surface thickness all as specified and directed.
M&L for cement concrete type E 2 1:5:10 using 40 mm graded stoine aggregate as in foundation filling and mass concreting and sub base for floor all as specified and directed.
Material and labour for 50mm thick Cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as flooring shall be laid in alternate bays and finishing the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6) type C-2 (using 20 graded aggregate) as in plinth protection and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen and 3 parts sand), finished the surface fair and even complete all as specified and as directed.
S&F Glass dividing strips 38mm wide and 3mm thick inserted and fixed in position complete all as specified and directed.
S&F pressed steel frame for doors with one rebates size of frame 105x60 mm including necessary fixing lungs hinges lock strike plate etc complete all as specified and directed.
M&L for PCC 1:3:6 type C0 (using 12.5 mm graded stone aggregate) as in back filling of pressed steel frame etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in bed blocks for hold fast & similar work etc complete all as specified and directed.
Supply and fixing for factory made 35 mm thick flush shutters solid core construction with block board core and plywood face panels all as specified and directed.
Supply and fix 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 150mm size extruded aluminum alloy handle fabricated type anodized (ISI Marked) complete all as specified and as directed.
Supply and fix 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
Supply and fix Steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
Supply and fix 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fixing for Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, bracket of angle etc and similar work conforming to Fe - 290 Gde E - 165 complete all as specified and as directed.
Excavation in post holes (or Similar holes) each in soft/loose soil not exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50m and making good surface complete all as specified and as directed.
S&F pre-painted galvanized aluminium zink coating GI based corrugated steel sheeting 0.50 thk of an colour having tensile strength 550Mpa as in roofing fixed with self tapping screws complete all as specified and directed.
All as per item No. 43 here-in-before but as in ridge/flashing board of width and girth not less than 610mm.
M&L for rolled mild steel work as in truss, bracket, rafter, purlien, made out of anglle/Hollowpipe/tube section including jointing cleats, plates flat iron, gusset plates, rails, braces etc Fe - 290 Gde E - 165 Quality, confirming to IS-1161-1979 of grade St - 240 complete all as specified and as directed.
Supply and fix in repair PVC (SWR) pipe 110 mm bore,single socketed, in any length with rubber ring joints fixed to walls with and including PVC clip complete all as specified and directed.
M&L for preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified.
Preparation of new steel surface of any description and applying two coats of synthetic enemal paint over a coat of primer.
Dismantling the existing ceiling board of any description fixed in any position with nails and S&F in position suspended false celling system using E Grid suspended celling Grid system of M/S Everest industries Ltd or India Gypsum. The size of Grid shall be 600X600mm with GI frame work, main runner 39X24mm, cross tee 29X24mm and wall angle 22.2X22.2mm using 4mm thick High Pressure Stream cured non primered classic/designer variant E-Board ISI Marked IS No 14862-2000. Fibre cement E Board to be placed in the gird of E Grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the pulins of the roof with butter fly clips complete all as specified and directed.
Roiling and consoliding road formation surfaces with 8 to 10 tonne power road roller, watering as necessary including filling in hollows and depressions to required true gradient and camber complete.
M&L soling or sub base with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber Spread thickness in 150mm complete all as specified and directed.
M&L for 100mm thick cement concrete type D2 1:4:8 (using 40mm graded aggregate) as in sub base for stone sett pavings complete all as specified and directed.
Material and labour for providing cement concrete 1:2:4 type B1 using 20mm graded aggregate as in pavement/hard standing, mass concrete filling etc including necessary form work complete all as specified and as directed.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attahced pillasters buttresses, etc vertical or to batter for flat rough finished surface of concrete.
M&L RCC type B-1 (1:2:4) using 20 mm grades aggregate nominal mix in walls, retaining walls, basement walls, ballast walls and the like any thickness above top of footing including attached pillasters and buttresses complete all as specified and directed.
M&L for light/fan Point wiring with PVC insulated unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable 1100 Volts grade & 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit as concealed conduit not less than 19/20 mm dia with all fittings, shunk in MS Pressed steel terminal boxes suitable depth and 1.6mm thick (duly painted with two coat of anti corrosive paint out side and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as directed Engr-in-Charge. (Make of cable:-Plaza/Paragon/Havells/Finolex/Anchor/L&T) Note : (i) On RCC roo/ceiling PVC conduit will be carried out by proper fixing with clips (ii) Colour coding should be maintained.
All as per item No. 57 here-in-before but with socket outlet 5 Amps controlled by one switch on the same board.
All as per item No. 57 here-in-before but with One socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 57 here-in-before but with 2.5 Sq mm for one 15 Amps socket outlet on independent board and 2.5 Sq mm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
M&L for Sub main wiring with PVC insulated, unsheathed, multistranded copper condurtor FRLS cable of size 3 runs x 4 Sqmm (Phase, neutral & earth) drawing into 20mm PVC conduit complete all as specified and directed. (Note :- 3 runs of copper condition and one run of PVC conduit shall be measured as one length).
S&F for Switch piano flush button type single pole, one way 5 Amps, 240 Volts, complete all as specified and directed.
S&F for Socket outlet 5 pin, 5 Amps, 240 volts flush type complete all as specified and directed.
S&F Switch Socket combination 2 in 1, 5 Amps flush type, 230 Volts complete all as specified and directed.
S&FSwitch Socket combination, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 Volts complete all as specified and directed.
S&F for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
S&F electronic fan regulator step 5, 250V flush type on the exiting phenolic laminated sheet complete all as specified and directed.
S&F Lamp holder PVC/ Polycarbonate insulated body with back plate for angle/batten fittings complete all as specified and directed.
S&F LED bulb 7 watt Lamp complete all as specified and directed.
S&F new generation energy saving, wall mounted LED Tube light batten fittings, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED 6K (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz.
S&F LED bulk head luminaries IP65 with opal diffuser 10 watt, 230 Volts complete all as directed Engr-in-Charge.
S&F sheet metal enclosure MCB distribution board, 4 way, Double door with IP-43 protection single phase 240 Volts, including suitable size copper bus bar and neutral link, fixed flush in wall including taking out old DB's and cutting chases to wall as per site requirement for fixing DB and making good disturbed wall/surfaces to match with existing specification.
S & F 'C' series MCB SPN 6 to 32 Amps complete all as specified and directed.
S & F 'C' series MCB SP, 6 to 32 amps complete all as specified and directed.
Supply and fiixing of ceiling fan 1200mm sweep high speed, single phase, 50 Hz energy efficient, 3 Star rating, 230 Volts including down rod and canopy complete all as specified and directed.
Material and labour for 10mm rendering in cement mortar (1:3) to ceiling and similar work finished the surface even and smooth without using extra cement complete all as specified and directed.
Preparation of new ceiling plaster surface and applying three coats of white washing on ceiling surface complete all as specified and directed.
pyarelal galar
M/s SHIVRATAN CONSTRUCTION
TANUJ CONST. CO.
AFSA ENGINEERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .