Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.0 L+₹60,995 (9.60%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.1 L+₹77,745 (12.2%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹7.6 L+₹1.2 L (19.0%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹7.8 L+₹1.4 L (22.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹10.8 L
Closing Date
15 Dec 2021, 9:30 amClosed
Executive_Engineer
EE,EandM,DIV,APWD,PP,PB
Renovation of Type-II Quarter No 01,02,03,04, 05,06,07,08, 09,10 and 11,12,13 of STS at Hut Bay SW Providing IEI
2021_APWD_4386_1
NIT No. 64/EE/EandM/21-22
Open Tender
Electrical Works
Item Rate
75 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
12 Jan 2022
25 Nov 2021
15 Dec 2021
25 Nov 2021
15 Dec 2021
29 Nov 2021
26 Nov 2021 - 29 Nov 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group-A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing of surface mounted 1 x 20 Watt white powder coated CRCA box type industrial batten with polycarbonate retrofit T8 Tube as equivalent to C&S product Code No. CRUX/1X20W (Ordering Code No. LTIC00120WLED/ WD) or its equivalent make.
Supplying and fixing of PVC Batten Holder as required
Supplying of 7 Watt LED Lamp Similar to C&S Cat No. LTHPLEDLAMP7W/B22 as required
Supplying and Fixing of LED Bulkhead fitting 10 Watt complete with accessories etc as required similar to C&S Code LTB10WLED or its equivalent
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as require
Supplying of AC Ceiling Fan (1200 mm) Sweep ISI Marked i/c down rod of standard length 30 cm with all accessories similar to Havells ES-50 or its equivalent
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way , Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Providing and fixing Sintex SMC 1-Phase Meter Box Hinged (L) of size 250 x 250 x 155 mm (inside side) for accommodating one LT 1 Phase KWh meter as equivalent to sintex Cat No. GSMB 2525 including cut out etc., as required.
DAYAL HALDER
M K ENGINEERING
M/s G K Construction
M/s Sai Electrical Works
BLUE CHIP CONSULTANCY SERVICE
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .