Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹1.7 L
EMD Value
₹5,000
Closing Date
20 Aug 2026, 6:00 pmClosed
CWE (AF) TUGHLAKABAD
Headquarters CWE AF Tughlakabad, Air Force Station, Tughlakabad, PO Sangam Vihar, New Delhi 110 080
STRUCTURAL INTEGRITY AUDIT FOR OVERHEAD TANK AT VAYUSENABAD UNDER GE (AF) TUGHLAKABAD
2026_MES_779589_1
CWE/TKD/TOKEN-44 OF 2026-27
Open Tender
Civil Works
Item Rate
45 days
TUGHLAKABAD
As per NIT.
7 documents required · 7 mandatory
₹300
GE (AF) TUGHLAKABAD
₹5,000
Yes
22 Aug 2026
18 Jul 2026
22 Aug 2026
18 Jul 2026
20 Aug 2026
1 Aug 2026
20 Jul 2026 - 27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and Labour for conducting of Structural audit for Overhead Tank at Vayusenabad, AF STN Tughlakabad. Following works shall be carried out in detail:-
(1) Mobilization of necessary equipment and manpower to the project site and removal of the same outside from the MOD area.
(2) To do survey of structural system by Rapid visual screening as per IS 13935:2009 and 5988:2013
(3) Testing by rebound hammer and Ultrasonic pulse velocity test as per the relevant IS.
(4) Carryout necessary Half Cell Potential test.
(5) To do photographic survey of the building.
(6) To study the structural system of the building.
(7) To study the defects in structural elements etc and marking of critical stress areas.
(8) Identification of broad area/ location in the structure requiring further detail investigation and for conducting various ND tests.
(9) To mark all photographs and structural defects on drawings.
(10) To conduct seepage/ leakage survey and look out for defects in other services in the building which are affecting the structural system.
(11) Diagnosis & root cause analysis of the problem/ observations.
(12) To submit a detailed report of inspection done along with interpretation of test report results.
(13) To submit status of stability of the structure.
(14) To suggest repair required in the structure and necessary remidial measures for strengthening of the structure.
Note: Test report shall be submitted duly vetted from any govt approved Government Engineering Institute/ NIT/ IIT and quoted rate shall deemend to have inclusive of this aspect and nothing extra shall be paid on this account. | 1 | Each | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
CompleteTenderDocuments.pdf
Tender Documents • 0.27 MB
BOQ_873198.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .