| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹27.3 L+₹11.6 L (74.1%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹27.4 L+₹11.7 L (74.3%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L3 | Rejected-Finance L3 | |
| 4 | L4₹27.5 L+₹11.8 L (75.4%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹28.0 L+₹12.3 L (78.3%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L5 | Rejected-Finance L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Sept 2022, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR/ REPLACEMENT OF EXTERNAL ELECTRIFICATION SYSTEM ALONGWITH STREET LIGHTS AT EAST OF MALL ROAD UNDER GE (EAST) JALANDHAR CANTT
2022_MES_527891_3
GE/JULL/ET-20/2022-23
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹50,000
Yes
20 Oct 2022
31 Aug 2022
28 Sept 2022
31 Aug 2022
21 Sept 2022
16 Sept 2022
Amount
Repair/ rectification for street/ security light/ perimeter light/ flood light any type, any make and any capacity against complaints of received through telephone or in person to make the security/ street lights in serviceable & functional condition as intimated by JE in-charge by rectification/ trace out the fault which includes disconnecting connection wire, removing/ taking down of street/ security light fitting from wall/ bldg/ plinth/ LT/ HT PCC/ steel tubular/ swan neck poles/ octagonal poles upto 11 mtr height from ground level or any other location, bring to MES workshop, opening the screws, step opening, diagnosing the fault, replacing the defective spare parts/ connection wire or any other part in presence of JE (E/M) or deptt rep etc, cleaning of light fitting/ glass/ acrylic cover, re-assembling, testing for functioning, shifting back to site and re-fixing on GI pipe bracket/ wall/ pole after repair, making necessary connections or tightening of loose connection on ACSR conductor/ in bar chamber/ in DB, including any type of repair in timer switch box as required to make the light fitting functional. The replacement of parts i.e. driver, SPD, LED lamp, LED panel, MCB contactor, or any other part if required shall be measured and paid separately under relevant item of BOQ.
Notes : (a) Light fittings, flexible wire and LED driver, street light timer, MCBs, contactors, junction boxes or any other item etc if required to be replaced in repair shall be measured and paid separately under relevant items of BOQ for supply only in-replacement. The quoted rate include cost of minor parts i.e. screws, thimble, insulation tape etc required. (b) Complaints shall be attended and rectified within 04 hrs of receipt of complaint. (c) Repair of one light shall be measured as one unit for measurement. (d) Contractor will get make and sample approval of items required to be replaced mentioned at Srl No. 13.00 to 20.00 here-in-after and will hand over to JE in-charge with all PV & TC to ensure repair of street light any time when required during currency of contract and these items/ material will be issued by JE (E/M) daily on actual assessment of complaints to replace the defective part and for accounting of items. The contractor will maintain register regarding details of daily complaints received, pending, rectified, items replaced on daily basis duly signed by contractor, JE etc.
(e) Old retrieved material shall be deposited to JE (E/M) in AGE (E/M) yard/ E/M workshop on same day and will be given to contractor at the time of RAR after necessary recovery under Sch of Credit. (f) The contractor or his rep will get complaints from JE/ Engineer-in-Charge on daily basis in morning to repair lights. The contractor/ his authorised representative will receive the instruction/ complaints from JE (E/M) regarding detail of security light to be repaired daily at 0900 Hrs. In case contractor/ his rep do not receive complaint in morning, a recovery as per relevant PS clause shall be recovered which remains pending due to non-availability of contractor manpower. (g) Contractor will provide vehicle, ladder, any other tools & plants required at site at his own costs nothing extra will be admissible on account of this. (h) If a number of lights found unserviceable due to non-availability/ any defect in electric supply, then making of all lights functional rectification of electric supply be measured as one unit. (j) The contractor/ his rep will report back to JE as same day for feedback of complaints done/ rectified.
All as per item No. 1.00 here-in-before but for gate light/ post top lantern of any type, wattage and make
All as per item No. 1.00 here-in-before but for 12.5/ 16 m high mast lights including bringing down of high mast light bracket down to ground level, dismantling/ repair the lights after replacement of parts, assembling/ re-fixing the lights and taking up the light bracket complete with the help of motor or any type of manual labour work including any disconnection/ connection of cables involved. Note : The taking down of high mast light down, repair of one or more lights and taking up and fixing the bracket on top at one time will be measured as one unit for payment
Supply and fixing LED street light fitting 45 watts, made up of pressure die-cast aluminium housing with clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF>0.95, LED source : Hi power LED 3 to 5W, having external potted constant current driver moisture resistant (installed in separate independent compartment) with internal surge protection 4 KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150V to 270V AC at 50 Hz, auto cut off >300V and with separate external surge protection device 10KV suitable for fitting on 32/40mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified and directedNotes : (a) All LED fitting shall be made in India and of standard size only.(b) All LED fittings shall have supporting LM-79 & LM-80 test certificate from Govt approved NABL accredited Lab showing all the parameters duly signed by the local office bearer of manufacturer.(c) All LED fittings shall have 2 years written warranty from local office bearer of manufacturer.(d) The old unserviceable LED fitting shall be issued by JE in-charge after deducting amount as per Sch of Credit at the time of RAR(e) The old unserviceable light fitting may be of lower wattage/ old specification, no claim will be entertained on this account.
All as per item No. 4.00 here-in-before but of capacity 60W
All as per item No. 4.00 here-in-before but of capacity 70W
All as per item No. 4.00 here-in-before but of capacity 90W
All as per item No. 4.00 here-in-before but of capacity 120W
Supply and fixing LED flood light fitting 150 watts, made up of pressure die-cast aluminium housing with toughened clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF>0.95, LED source : Hi power LED 3 to 5W, potted constant current driver moisture resistant with internal surge protection 4 KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150V to 270V AC at 50 Hz, auto cut off >300V and separate surge protection device 10KV complete having fixing bracket clamp all as specified and directed Notes : (a) All LED fitting shall be made in India and of standard size only. (b) All LED fittings shall have supporting LM-79 & LM-80 test certificate from Govt approved NABL accredited Lab showing all the parameters duly signed by the local office bearer of manufacturer. (c) All LED fittings shall have 2 years written warranty from local office bearer of manufacturer. (d) The old unserviceable LED fitting shall be issued by JE in-charge after deducting amount as per Sch of Credit at the time of RAR (e) The old unserviceable light fitting may be of lower wattage/ old specification, no claim will be entertained on this account
All as per item No. 9.00 here-in-before but of LED light fitting 120W
All as per item No. 9.00 here-in-before but of LED light fitting 60W
Supply and fixing in replacement new generation, post-top, gate light energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source 25W, 5700K complete all as specified and directed. Make: Havells/Crompton/ Polycab.
Supply and fixing in repairs CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, efficacy > 110Lm/W power factor 0.95 suitable for existing LED street light of capacity 42W to 45W complete all as specified and directed. Note : The contractor shall have to procure the suitable driver for existing LED light fittings which can be accommodated in light fitting without any problem.
All as per item No. 13.00 here-in-before but of capacity 60W
All as per item No. 13.00 here-in-before but of capacity 70/72W
All as per item No. 13.00 here-in-before but of capacity 90W
All as per item No. 13.00 here-in-before but of capacity 120W
All as per item No. 13.00 here-in-before but of capacity 150W
Supply and fixing SPD (Surge Protection Device) suitable for LED street light/ flood light fitting to avoid surge protection voltage upto 5KV complete all as specified and directed
Supply and fixing SPD (Surge Protection Device) suitable for LED street light/ flood light fitting to avoid surge protection voltage upto 10KV min complete all as specified and directed
Supply and fixing in replacement 3 pole contactors 32 Amps with coil voltage 230 volts suitable for timer panels complete all as specified and directed. Make : BCH/ Havells/ C&S/ Indo Asian
Supply and fixing in replacement 3 pole contactors 40 Amps with coil voltage 240 volts suitable for timer panels complete all as specified and directed. Make : BCH/ Havells/ C&S/ Indo Asian
Supply and fixing astronomical digital timer for switching on/ off lights according to rising/ setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/ or fixed pre-set time, current capacity 16 A, weekly program with changeover (1 CO), total 28 programmes min complete in powder coated CRCA sheet enclosure of suitable thickness with MCB TPN 32 Amp min, 3 pole contactor 32 Amp and MCB for manual switching of lights, fixing arrangement i.e DIN rail complete with necessary porcelain insulator for incoming and outgoing cable connection with required clamp duly painted to fix on pole complete all as specified and directed Make : Indoasian/ Siemens/ Schneider/ L&T/ Legrand
Supply and fixing factory made junction box of size 150 x 150 x 100mm suitable for post top lantern, made out of CRCA powder coated sheet 2mm thick having front hinged shutter with lockable arrangements, outdoor type, weather proof duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer, having the provision to connect incoming and outgoing cable of size 16 sqmm 2 core and including one number MCB SP, 10 KA, C-Curve, 6 Amps 240 volts including two DMC insulator and earthing plug complete all as specified and directed. Notes : (i) Clamps, nuts, bolts and washer will be measured and paid separately. (ii) MCB shall be measured and paid for separately.
Supply and fixing in replacement bracket made out of 40mm dia light grade GI tubing 1.2 metre long and bent to shape at 120° angle with required holes for passing connection cable, fixed with clamps nuts and bolts, washer complete all as specified. (Clamps, nut, bolts and washers will be measured and paid separately).
Supply and fixing in replacement bracket made out of 25mm dia light grade GI tubing 1.2 metre long and bent to shape at 120° angle with required holes for passing connection cable, fixed with clamps nuts and bolts, washer complete all as specified. (Clamps, nut, bolts and washers will be measured and paid separately).
Supply and fixing in replacement MCB C-curve, 10 KA, SP 6 to 10 Amp, 240 volts including taking down the existing unserviceable MCB and all the necessary electrical connections complete all as specified and directed.
Supply and fixing in replacement MCB C-curve, 10 KA, SPN 25 Amp, 240 volts including taking down the existing unserviceable MCB and all the necessary electrical connections complete all as specified and directed.
Supply and fixing in replacement MCB C-curve, 10 KA, SPN 40 Amp, 240 volts including taking down the existing unserviceable MCB and all the necessary electrical connections complete all as specified and directed.
Supply and fixing in replacement MCCB 63 Amp, 415 V, 16 KA, 4 pole with fixed thermal magnetic release ICS=100% ICU with spreader links and phase separator complete all as specified and directed.
Supply and fixing in replacement MCCB 100 Amp, 415 V, 25 KA, 4 pole with fixed thermal magnetic release ICS=100% ICU with spreader links and phase separator complete all as specified and directed.
Supply and fixing in replacement MCCB 160 Amp, 415 V, 25 KA, 4 pole with fixed thermal magnetic release ICS=100% ICU with spreader links and phase separator complete all as specified and directed.
Supply and fixing in replacement MCCB 200 Amp, 415 V, 25 KA, 4 pole with fixed thermal magnetic release ICS=100% ICU with spreader links and phase separator complete all as specified and directed.
Taking down ACSR of any type and size by opening binding wires, removing outgoing electric connections by opening cable connections, removing spacers complete all as specified and directed Note : The decision of Engineer-in-Charge will be final and binding regarding the no of spans/ length and no of phase or neutral conductors to be removed/ taken down from site
Supply and fixing aluminium conductor steel reinforced of size ferret/ mink or other size required at site in required length/ span for overhead lines on poles stretching/ stringing without kinks and bends, including fixing with insulators using aluminium binding wire (rates inclusive), jumpers, line tapes etc and making necessary outgoing cable connection etc complete all as specified and directed
Supply and fixing continuous earth wire 4mm dia galvanised steel wire including galvanized mild steel binding wire 10 SWG or any other size required at site including removing old GI wire where exists complete all as specified. Note: For payment purpose weight of 4mm dia galvanised wire only shall be taken and clamps, hooks shall be measured and paid separately
Dismantling insulators any type, any size complete with opening of ACSR binding wire complete all as specified and directed
Supply and fixing pin type insulator 100mm height, 65mm dia for 1100 volts grade porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts complete all as specified
Supply and fixing in replacement shackle type insulator pressure porcelain vitreous white, brown or green insulator for 1100 volts grade complete all as specified and directed.
Supply and fixing in replacement loop type insulator porcelain vitreous white or brown, for LT stay large size with overall dissensions 65x140mm, clearance hole 20mm for 1100 volts grade complete all as specified.
Supply and fixing in replacement MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer including dismantling/ taking down existing MS work complete all as specified and directed. Note: Unexposed surface shall be given one coat of primer only.
Dismantling damaged concrete poles/ struts/ steel poles upto 11m height complete with necessary excavation work, dismantling/ demolition of RCC foundation/ coping and removing complete of any size, height and shifting for taking credit all as specified and directed.
Dismantling concrete poles/ struts/ steel poles complete with necessary excavation work, dismantling/ demolition of RCC foundation/ coping and removing complete of any size, height and shifting for re-use within 500m without making any damage to pole and re-fixing at new location all as specified and directed Note : The poles having serviceable condition will be shifted to new location within 500m for re-fixing/ reuse. The earth work at new location for fixing of pole shall be measured and paid separately
Supplying, erecting and fixing pre-stressed concrete pole 9.0 metre long having x-sectional area 102 x 172mm at top and 102 x 279mm at bottom, class 10, complete all as specified including painting of poles with two coats of synthetic enamel paint over a coat of primer, black & white strips upto 1.5mtr height from top of PCC coping and numbering of poles fixed in repairs of old broken pole complete all as specified and directed. (PCC and earth work shall be measured & paid for separately)
Material and labour for swaged steel tubular poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws type 410 SP-31 (9 mtr long) including painting of poles upto 1.5m height from coping with two coats of synthetic enamel paint black & white strips and numbering of poles complete all as specified and directed (PCC and earth work shall be measured & paid for separately)
Material and labour for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of electric pole, etc. including necessary form work and fair finish to exposed surface without using extra cement complete all as specified & directed.
Material and labour for stay assembly complete with accessories as shown in electrical plate No. 1 including loop type insulator large size, stay clamps, stay plate 230 x 230 x 6mm, galvanized stay rod 16mm dia, 14mm dia stay bow, galvanized stay stranded wire 7/3.15mm, necessary excavation and any type of earth work complete all as specified an directed. Note : PCC (1:3:6) type C-2 shall be measured and paid separately.
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded mechanically crushed stone aggregate as in foundation of stay/ coping of poles including necessary form work and fair finish to exposed surface without using extra cement complete all as specified & directed.
Supply and fixing 100mm bore galvanised pipe light grade for passing of cable fixed to poles/ walls/ laying under floor complete with and including fittings and clamps as required complete all as specified and directed.
All as per item No. 49.00 above but 80 mm bore pipe
All as per item No. 49.00 above but 50 mm bore pipe
Material and labour for Boring hole under the road/ pavement/ hard standing of any width and inserting HDPE pipe of 150mm at a depth not less than one metre below ground level complete all as specified & directed. Note: HDPE pipe 150mm shall be included and paid in quoted rate
Supply and fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 6 Sqmm flat twin core cable in service connection including taking down/ out unserviceable conductor connection all as specified and directed.
Supply and fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 10 Sqmm twin core flat cable in service connection including taking down/ out unserviceable conductor connection all as specified and directed.
Supply and fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 16 Sqmm twin core flat cable in service connection including taking down/ out unserviceable conductor connection all as specified and directed.
Taking down/ out unserviceable UG cables of any cross sectional area, any type, any make from trench/ from wall/ pole/pulling through pipe by opening connections and joints including removing pipe, bricks etc of any description from trenches or fixed with walls/ poles, segregating serviceable bricks/ cable cover, cables etc and keep in safe custody for reuse, complete all as specified and directed. Note : Earthwork shall be measured and paid under appropriate items of BOQ
Supply, laying, jointing and testing UG XLPE insulated, PVC sheathed , steel strip or wire armoured electric cable 1100 volt grade (heavy duty) with stranded aluminium conductor of size 10 Sqmm, 4 core laid in trenches, in floor, in duct, through pipes/ culvert or along the pole/wall complete all as specified and directed
All as per item No. 57.00 here-in-before but of size 16 Sqmm 4 core
All as per item No. 57.00 here-in-before but of size 25 Sqmm 3½ core
All as per item No. 57.00 here-in-before but of size 50 Sqmm 3½ core
Laying, jointing and testing underground PVC armoured cable insulated and PVC sheathed LT 1100 volt grade (heavy duty) with standard aluminium conductor of size 35 Sqmm 3½/4 core laid in trenches, in floor, in duct, through pipes or along the pole including taking out unserviceable cable complete all as specified and directed
All as per item No. 61.00 here-in-before but of size 95 Sqmm 3½ core
All as per item No. 61.00 here-in-before but of size 120 Sqmm 3½ core
All as per item No. 61.00 here-in-before but of size 185 Sqmm 3½ core Notes for item No. 57.00 to 64.00:- (i) Excavation & earth work, sand cushioning, brick protection cover, GI protection pipe and clamps shall be measured and paid for separately. (ii) For Item No. 61.00 to 64.00 : LT cable shall be issued under schedule ‘B’ ‘Free for laying only’ by the department.
Material and labour for astro timer of rating 16 Amp to replaced existing unserviceable timer including necessary connections complete all as specified and directed
Excavation in trenches in soft/ loose soil n. exc. 1.5 m wide and n. exc. 1.5 in depth for laying of cables, erecting poles/ stays etc. and getting out complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removal of surplus soil to a distance n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed.
Material and labour sand cushioning with 8cm thick layer of sand before laying of cable and 15cm thick after laying of cable in trenches punned down to thickness of 18 cm complete all as specified and directed.
Supply & laying old size sub class 'B' bricks laid flat in trenches across the cable with the length of brick perpendicular to the length of cable abutting each other complete all as specified.
Laying only serviceable bricks retrieved during taken out of cable from excavation, laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable of length, adjacent/ abutting each other complete all as specified.
Material and labour for locating fault of LT underground cables of size 10 Sqmm to 35 Sqmm 3.5 core/4 core laid in trenches by excavating and visually (upto 10 mtr of length) the faulty portion of cable, taking out to protection bricks or cover, sand and faulty cable and making of joints or repair to existing joint including all jointing material such as LT joint, ferrule and relaying after repair including refiling of sand and relaying of brick protection cover complete all as specified and directed. Note : (a) LT joint will be measured and paid separately.
Material and labour for locating fault of LT underground cables of size 50 Sqmm to 70 Sqmm 3.5 core/4 core laid in trenches by locating fault with fault locator machine with machine operator and excavating the faulty portion of cable (upto 10 mtr of length) taking out the protected bricks or cover, sand, faulty cable and making of joints or repair to existing joint including all jointing material such as LT joint, ferrule and relaying after repair including refiling of sand and relaying of brick/ protection cover complete all as specified and directed. Notes : (a) LT joint will be measured and paid separately. (b) The contractor will have to arrange the fault locating machine. A penalty of Rs. 300 per hour will be imposed/ levied, if contractor fails to arrange the machine within 6 hours of fault intimation. The quoted rate includes cost of arranging, shifting of fault locator machine, any operating charges at site. T&P required, number of times as and when required during the currency of contract. Nothing extra will be paid on the account. (c) The qty catered will be executed different times during currency of work whenever fault occurs/ develops, hence fault locating machine may be required numbers of times during currency of work as directed by Engr-in-Charge. Hence contractor shall quote his rate accordingly considering this aspect.
All as per item No. 73.00 here-in-before but of size 95 to 150 Sqmm 3½ core
All as per item No. 73.00 here-in-before but of size 185 to 300 Sqmm 3½ core
All as per item No. 73.00 here-in-before but of size 400 Sqmm 3½ core
Supply and fixing heat shrinkable straight through joint suitable for 1100 V, XLPE/ PVC cable for size 240 Sqmm to 400 Sqmm 3½ Core complete all as specified and directed
Supply and fixing heat shrinkable straight through joint suitable for 1100 V, XLPE/ PVC cable for size 95 Sqmm to 185 Sqm 3½ Core complete all as specified and directed
Supply and fixing heat shrinkable straight through joint suitable for 1100 V, XLPE/ PVC cable for size 25-70 Sqm 3½ Core complete all as specified and directed
Material and labour preparation of old painted surface of steel tubular poles 9.0m long and applying one coat of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and two coats of aluminium paint to remaining part of poles above strips including painting of street light brackets, clamps, cross arm and numbering the pole complete all as specified and directed.
Material and labour preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and numbering of poles including painting of two coats of aluminium paint on street light brackets, clamps, nut bolts, cross arm etc complete all as specified and directed.
Material and Labour for cutting/pruning of tree branches 1.5mtr all around the Lt overhead lines of span (not exceeding 50 mtr) and around the pole obstructing the overhead line & removing the branches to a distance not exceeding 200 mtr to the entire satisfaction of Engineer-in-Charge. Note:- The rate quoted include any type of T&P i.e ladder, cutting machine, cutter, axe etc required at site.
Re-stretching of existing loose OH, LT ACSR conductor wire any type/ any supply including GI wire along the span of pole 4 to 6 lines for sagging within the permissible limit, including disconnecting cable connections, opening of binding wire, winding/ rewinding/ joining with aluminium winding wire in case of breakage of conductor and re-stringing at same place as same phase or changing the location to use as neutral or other phase complete all as directed and again fixing to insulators with binding wire and making outgoing electric cable connections. the size of binding wire of same size as made up of conductor complete all as specified and directed. Notes : (a) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during stretching. (b) Cutting trimming of hanging/ extended branches of trees upto a distance 2 m from the overhead HT/LT line and making the line clear upto the entire length of the re-stretched ACSR feeder including removal and disposing of the cut tree/ branches 200 m away for the site as directed is deemed to be included in the quoted rate. (c) Piece of conductor of suitable size required for connecting the broken conductor included in the rates quoted by the contractor. (d) Each span will be consist of 3 to 5 ACSR conductor. Which will be measured as one unit only. Hence contractor shall quote his rate accordingly.
Material and Labour for removing of fallen/ broken pole due to any climatic/ mis-happening condition with help of crane by disconnecting all conductor, jumpers, cross arms, street light fitting and fixing the new pole with re-stretching the existing overhead line and making good complete all as specified and directed Note : PCC pole and re-stretching will be measured and paid against other items of BOQ
Material and labour in replacement earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level covered on all sides with alternative layers of charcol dust and common salt 15 cm thick connected to galvanised earth lead Galvanised Iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of Galvanised Iron or steel with protection pipe earth wire protected by galvanized steel pipe light grade 40 mm bore from top of the earth plate electrode upto test point and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shown in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indicated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCC covered with CI cover hinged with frame including excavation and earth work complete all as specified. Notes : 1. If result is not satisfactory then contractor will do 2nd earthing on his own cost. 2. Contractor will give 2 years warranty of earthing in writing. 3. The rate deem to be included in quoting, GI strip 32 x 6 mm earth strip from earth plate to test point and the strip 25 x 3 mm test point to equipment.
All as per item No. 85.00 above but GI wire 4mm dia
Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm aluminium strip all as specified and directed.
Supply and fixing in replacement aluminium thimbles suitable for 150 to 240 Sqmm underground cable, crimping and connecting with MCCB complete including disconnecting cables and making necessary connections after fixing thimble all as specified and directed
Supply and fixing in replacement aluminium thimbles suitable for 95 to 120 Sqmm underground cable, crimping and connecting with MCCB complete including disconnecting cables and making necessary connections after fixing thimble all as specified and directed
Supply and fixing in replacement aluminium thimbles suitable for 35 to 70 Sqmm underground cable, crimping and connecting with MCCB complete including disconnecting cables and making necessary connections after fixing thimble all as specified and directed
Supply and fixing in replacement aluminium thimbles suitable for 10 to 25 Sqmm underground cable, crimping and connecting with MCCB complete including disconnecting cables and making necessary connections after fixing thimble all as specified and directed
Supply and fixing wall/ pole mounted bus bar chamber with copper bus bar current rating 100 Amp 4 Nos suitable for 415V, 50 Hz AC supply complete making all incoming and outgoing connections in CRCA powder coated steel enclosure of size 400 x 300 x 200mm complete with fixing clamp all as specified and directed
Material and labour for maintenance free battery 12V, 180 AH complete all as specified and directed
Material and labour for painting of cross arms 0.60m long with clamps in position on 9m long pole and applying two coats of aluminium paint over one coat of red oxide complete all as specified and directed
Disconnecting XLPE/ PVC insulated armoured aluminium conductor cable connection from ACSR, removing from the pole and Supply and fixing end termination outdoor heat shrinkable joint suitable for 6 to 16 Sqmm, 4 core PVC/ XLPE cable and re-fixing the cable alongwith pole and making the connection with ACSR conductor complete all as specified and directed
All as per item No. 95.00 here-in-before but of size 25 to 50 Sqmm 4 core
All as per item No. 95.00 here-in-before but of size 70 to 150 Sqmm 4 core
Supply and fixing in replacement PVC insulated & PVC sheathed copper conductor of size 0.75 Sqmm , 3 core complete for street light including flexible conduit and making all as specified and directed
Kaul Enterprises
CHOUDHARY AND SONS
BHARAT ENGINEERS
Northern cable fault locatoers
AGGARWAL ENGINEERING CO
GULSHAN SINGH GHAI AND SON
Bains Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .