Loading…
Loading…
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
7 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or " V" whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully or substantially completed any of the following during last 07(seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of work for this tender is -" Any work of Signal or Telecom involving trenching, laying & testing of Signal or Telecom cables OR Any other miscellaneous S&T work."
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Signalling work- Howrah Division - TTR (FS+TWS+WCMSC) 60 Kg 1 in 12 - 74 Sets.
SDSTE-TTR-ASTE-RPH-26-27~ER
SDSTE-TTR-ASTE-RPH-26-27
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹6.0 L
13 Aug 2026
13 Aug 2026
24 Aug 2026
73 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,01,84,069 | ||
| — | — | — | Above/ 2995920.00 Below/P | ||
| Supply of Electric Point Machine-IRS type, (AC Immunity 160V AC), Non-Trailable to operate on 110V DC complete with Lock and Detector slides, (143mm throw, thrust as applicable, Rotary locking), confirming to IRS:S-24/2002 (Amdt.1) (Amdt. upto date if any) & Assy. Drg. No. RDSO-S10910 (Alt. upto date if any) & IRS:S 37/82 (Amdt.3) (Amdt. upto date if any) for Motor. Inspection: RDSO. | — | 40.00 | — | — | |
| — | — | — | Above/ 12000.00 Below/P | ||
| Termination of Outdoor Cables (Main Cables /tail cables) in location boxes, cable termination rack in relay room, station building, etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by the contractor (Lugs, eyelets, Power cables should be terminated with suitable lugs/eyelets wherever applicable). | — | 2000.00 | — | — | |
| — | — | — | Above/ 146780.00 Below/P | ||
| Supply of Ground Connection [BG] Threaded Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E.Rly drawing number, SL. No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below :- 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT-1. 5. Sleeve - BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement-BS/29/727 with ALT-1. Amdt. and alt. upto date if any. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). A)For Turn Out. | — | 20.00 | — | — | |
| — | — | — | Above/ 62830.00 Below/P | ||
| Supply of Ground Connection [BG] Threaded Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E.Rly drawing number, SL. No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below :- 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT-1. 5. Sleeve - BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement-BS/29/727 with ALT-1. Amdt. and alt. upto date if any. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). B)For Trap. | — | 10.00 | — | — | |
| — | — | — | Above/ 495810.00 Below/P | ||
| Supply of Ground Connection [BG] Threaded Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E.Rly drawing number, SL. No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below :- 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT-1. 5. Sleeve - BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement-BS/29/727 with ALT-1. Amdt. and alt. upto date if any. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). C)For Double Slip as per DRG No. SGW/S/2/HWH/1/92 or Latest. | — | 30.00 | — | — | |
| — | — | — | Above/ 875000.00 Below/P | ||
| Supply of Ground Connection [BG] Threaded Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E.Rly drawing number, SL. No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below :- 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT-1. 5. Sleeve - BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement-BS/29/727 with ALT-1. Amdt. and alt. upto date if any. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). D)For Single Slip as per DRG No. S-3153 or Latest. | — | 100.00 | — | — | |
| — | — | — | Above/ 80920.00 Below/P | ||
| Dismantling and releasing of existing Point machines (all types) including ground connections and other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. | — | 40.00 | — | — | |
| — | — | — | Above/ 7783000.00 Below/P | ||
| Disconnection & Reconnection of All Signalling Equipments like Cables/TLJB/Point Machine G.Fitting/PointJB/BPAC Track Device etc. immediate before and after the work during block period. This Includes cost of the Releasing of Signalling equipmets and Reconnection of the same after the work. This includes 1 Fitter, 1 BlackSmith, 1 Hammer Man,1 Cable Jointer, 1 Bondingfitter, 4 Khalasis. | — | 2000.00 | — | — | |
| — | — | — | Above/ 6400060.00 Below/P | ||
| Disconnection & Reconnection of All Signalling Equipments like Cables/TLJB/Point Machine G.Fitting/PointJB/BPAC Track Device and other Signalling works. This includes Supply of Labours(Helper/Assistant)of 5 Nos per Man Day to assist Signal Supervisor /Officer during Field Work& Other S&T work. | — | 2000.00 | — | — | |
| — | — | — | Above/ 155300.00 Below/P | ||
| Point insulation Complete set as per RDSO/SPN/168/2005 for 1. Switch 'D' bracket insulation for IRS point machine - One set comprises Side plate LH to Drg. No. S-3266 - 1 No. (b) Side plate RH to Drg. No. S-3265 - 1 No. (c) Insulating bush to Drg. No. S-3199 - 4 Nos. (d) Insulating washer to Drg. No. S-8640 - 4 Nos. 2.Split-Stretcher bar 2.1 Insulation for Leading stretcher bars (BG). Each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg. No. T-10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg. No. T-10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO Drg. No. T-10371 - 6 Nos. 2.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg. No. T-10367 - 3 Nos. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg. No. T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg. No .T10371-12 Nos. & 3. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg. No. T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg .No. T10368-3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO Drg. No. T-10371 - 6 Nos. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). | — | 100.00 | — | — | |
| — | — | — | Above/ 46000.00 Below/P | ||
| Gauge Tie plate insulation as per RDSO/SPN/168/2005 as per RDSO Drg. No. T-10372 Alt.2, T-10368, T-10371 Alt.2, T-15083/88 Alt.2 & T-11690 Alt.2 and as per RDSO/SPN/168/2005 with latest amendments as applicable. Gauge tie plates (52Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer. Each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg. No. T-10372 - 1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg. No. T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS-40/84 as per RDSO Drg. No. T-10371 - 6 Nos. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). | — | 100.00 | — | — | |
| — | — | — | Above/ 106400.00 Below/P | ||
| Ground connection insulations for thick web switch layout facing point (BG) for 52kg/60kg rail fitted with high thrust (220mm) point machine comprising of the following: Set 1. Bush as per Drg. No.S-3463 - 1 no. and Washer as per DRG. No. S-58640 - 2 no. for drive (throw) rod 2. Bush as per Drg. No.S-23199 - 1 no. and Washer as per Drg. No.S-8640 - 2 nos. for a short detector rod. 3. Bush as per Drg. No. S-3199 - 1 no. and Washer as per Drg. No. S-8640 - 2 nos. for a long detector rod. 4. Bush as per Drg. No. S-22179 - 1 no. and Washer as per Drg. No. S-8640 - 2 nos. for short lock rod. 5. Bush as per Drg. No. S-22179 - 1 no. and Washer as per Drg. No. S-8640 - 2 no. for long lock rod. 6. Bush 'B' as per Drg. No. S-8912 for LH lock slide - 1 no. 7. Bush 'B' as per Drg. No. S-8912 for LH lock arm - 2 nos. 8. Bush 'B' as per Drg. No. S-8912 for RH lock arm - 2 nos. 9. Bush 'B' as per Drg. No. S-8912 for RH lock slide - 1 no. 10. Bush as per Drg. No. S-23199 - 4 nos. and washer as per Drg. No. S-8640 - 4 nos. for the LH lock slide. 11. Insulating Plate LH as per Drg. No. S-3404 RDSO S- 3593 - 1 No. 12. Insulating Plate RH as per Drg. No. S-3404 RDSO S- 3592 - 1 No. 13. Bush as per Drg. No. S-23199 - 4 nos. and washer as per Drg. No. S-8640 - 4 nos. for RH lock slide. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). | — | 100.00 | — | — | |
| — | — | — | Above/ 138533.00 Below/P | ||
| Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc. and conforming to BRS:939A & 966(Appendix F2) and RDSO Spec No. IRS:S-34 ,S-23 with Amdt. Upto date as applicable or latest. Inspection: RDSO. | — | 29.00 | — | — | |
| — | — | — | Above/ 317200.00 Below/P | ||
| Supply of Self Regulating Type Battery Charger, 230V AC/24V DC, 20 Amps as per RDSO Spec. No. IRS:S-86/2000 (Amdt.4) or latest. Inspection: RDSO. | — | 10.00 | — | — | |
| — | — | — | Above/ 693950.00 Below/P | ||
| Supply of color light signal post 5.5 mtr. as per RDSO SPEC. NO. IRS:S-6-81 (or latest) and Drg. No. SA-23156 (ADV), Alt-1 or latest. Materials to be procured only from RDSO approved list of firms for manufacture & supply of mechanical signaling items. Inspection: RITES/Consignee. (As per extant guidelines, please refer tender documents). | — | 50.00 | — | — | |
| — | — | — | Above/ 66490.00 Below/P | ||
| Supply of Spares and accessories for UFSBI. Inspection: RDSO.A)Input card compatible with existing UFSBI system. | — | 5.00 | — | — | |
| — | — | — | Above/ 169380.00 Below/P | ||
| Supply of Spares and accessories for UFSBI. Inspection: RDSO.B)Output card compatible with existing UFSBI system. | — | 5.00 | — | — | |
| — | — | — | Above/ 145810.00 Below/P | ||
| Supply of Spares and accessories for UFSBI. Inspection: RDSO.C)CPU card compatible with existing UFSBI system. | — | 5.00 | — | — | |
| — | — | — | Above/ 124980.00 Below/P | ||
| Supply of Spares and accessories for UFSBI. Inspection: RDSO.D)Control & Communication card compatible with existing UFSBI system. | — | 5.00 | — | — | |
| — | — | — | Above/ 143030.00 Below/P | ||
| Supply of Spares and accessories for UFSBI. Inspection: RDSO.E)MODEM compatible with existing UFSBI system. | — | 5.00 | — | — | |
| — | — | — | Above/ 237740.00 Below/P | ||
| Supply of Spares and accessories for UFSBI. Inspection: RDSO.F)DC-DC Converter (Hot standby Type). | — | 5.00 | — | — | |
| — | — | — | Above/ 2639064.00 Below/P | ||
| Supply, Installation, wiring, testing and commissioning of Multi Section Digital Axle Counter (Detection points and Evaluators as per the Scheme) along with Toolkit, as per RDSO Specification No. RDSO/SPN/176/2013, Ver.3 or latest and as per Annexure-A. The warranty of the equipment shall be 2 YEARS from the date of commissioning. Inspection: RDSO. Note:- 1) Scheme of Main/Redundant (dual) Evaluators with approximate number of DPs connected shall be enclosed for each location of Evaluators. 2) Installation, wiring, testing and commissioning of MSDAC as per RDSO TAN/Guidelines and Annexure-B. Inspection: RDSO. | — | 8.00 | — | — | |
| — | — | — | Above/ 602600.00 Below/P | ||
| Supply of B Type Choke as per RDSO Spec. No. IRS:S-65/83 (Amnd.1) or latest. Inspection: RDSO. | — | 100.00 | — | — | |
| — | — | — | Above/ 100000.00 Below/P | ||
| "SUPPLY OF POLYMER POSITIVE TEMPERATURE COEFFICIENT DEVICE (PPTC) Resettable Fuses, for outdoor circuits. 30V/2.5A for track feed and 60V/1.1A in place of 24V/2A fuse and 120V/1.1A for signal lighting. Make- RAYCHEM, BOURNS, LITTLE FUSE, FUZETEC or TYCO. Quantity as per site engineer. Note- PPTC fuses are to be connected with crimped ring type lugs. ". Inspection: RITES/Consignee(As per extant guidelines, please refer tender documents). | — | 1000.00 | — | — | |
| — | — | — | Above/ 38500.00 Below/P | ||
| Supply of Non deteriorating type FUSE as per Spec No. IRS:S-78/2006 with latest amendments rating (2A/6A/10A/16A/20A) type, cylindrical. Inspection- RDSO. | — | 500.00 | — | — | |
| — | — | — | Above/ 112500.00 Below/P | ||
| Supply of fuse BASE (PBT) to Spec. No. IRS-S-78/2006 or latest, Drg. No. SA-23748 with fuse inserts cartridge, non-deteriorating type to Spec. No. IRS:S:78/2006 with latest amendment, to be mounted inside the location box on the hylam sheet. Inspection: RDSO. | — | 500.00 | — | — | |
| — | — | — | Above/ 34000.00 Below/P | ||
| Supply of Fuse terminal block with LED indication up to 2.5 sq. mm. screw type one in one out suitable for 400mA/630mA/1A/1.6A/2A/4A/6.3A/8A10A or as decided by Engineer in charge as per RDSO SPN/189/2004 or latest. Inspection: RDSO. | — | 500.00 | — | — | |
| — | — | — | Above/ 28000.00 Below/P | ||
| Supply of Fuse links of (400 mA, 630 mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A, 250mA as per RDSO Spec. No. RDSO/SPN/189/2004 With latest amendments Inspection: RDSO. | — | 500.00 | — | — | |
| — | — | — | Above/ 28500.00 Below/P | ||
| Supply of Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). Inspection: RDSO. | — | 500.00 | — | — | |
| — | — | — | Above/ 10000.00 Below/P | ||
| Supply of Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63A - 3.0A (System, Rapid, Malnad or RBCO make or similar). Inspection: RDSO. | — | 500.00 | — | — | |
| — | — | — | Above/ 3120.00 Below/P | ||
| Supply of Indicative type Fuse suitable to G type Without holder 6A (System, Rapid or Malnad or RBCO make or similar) as per IRS:S-80/92 or latest. Inspection: RDSO. | — | 80.00 | — | — | |
| — | — | — | Above/ 3400.00 Below/P | ||
| Supply D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. Inspection: RDSO. | — | 100.00 | — | — | |
| — | — | — | Above/ 3500.00 Below/P | ||
| Supply of D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS:S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. Inspection: RDSO. | — | 100.00 | — | — | |
| — | — | — | Above/ 3682560.00 Below/P | ||
| Supply of 2V/80AH uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Spec. No. IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO. | — | 840.00 | — | — | |
| — | — | — | Above/ 388080.00 Below/P | ||
| Charging of 2V/80AH lead acid cell (Secondary cell) of various capacities as per Manufacturer's/Railway engineer's instruction. Acid and distilled water to be supplied by the contractor. Specific gravity acid should be approved type duly inspected by consignee. This includes installation and commissioning of the battery in circuit. Battery to be kept on a wooden rack. | — | 840.00 | — | — | |
| — | — | — | Above/ 1313112.00 Below/P | ||
| Supply of Self Regulating type Battery Charger, 230V AC / 110V DC, 30A single phase, signalling & telecom Installation as per Specification IRS: S 86-2000 Amd.4 or latest. Inspection: RDSO. | — | 12.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
InspectionCriteria_1.pdf
ATTACHMENT
CheckListAnnexItoVIIIUPDATED.pdf Annexure I to VIII
ATTACHMENT
Annexure-IX.pdf
ATTACHMENT
Annexure-X.pdf
ATTACHMENT
Annexure-XI.pdf
ATTACHMENT
AnnexureV.pdf
ATTACHMENT
Annexure_VA.pdf
ATTACHMENT
Annexure-VIA.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
GCCwithCorrectionSlips1to10.pdf
ATTACHMENT
ACS-11.pdf
ATTACHMENT
LabourCess_compressed.pdf
ATTACHMENT
VICINITYOFUNDERGROUNDCABLE- Panalty JPO
ATTACHMENT
TermsofPayment.July-25.pdf
ATTACHMENT
TenderDocument-TTR.pdf
ATTACHMENT
MSDAC-ANNEXURE1.pdf
ATTACHMENT
OnlineBG.pdf
ATTACHMENT
CheckListAnnexItoVIIIUPDATED.pdf
ATTACHMENT
JPO-CABLEDIGGINGWORK-VICINITYOFUNDERGROUNDCABLE-SRDSTESRDEN-C-240124.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].