SALEM DIVISION: Provision of EOLB and Emergency Sliding Boom at left over interlocked LC gates in ADSTE/SA & ADSTE/ED section over Salem Division (39 LCs)
SA-SG-120-I-OT-13-2025~SR
SA-SG-120-I-OT-13-2025
Open
Works - General
24 Months
Salem, Tamil Nadu
₹0
₹4.8 L
17 Dec 2025
25 Nov 2025
3 Dec 2025
A-Items which are covered under SOR 2022
B-Items which are not covered under SOR 2022
Item Breakup - A-Items which are covered under SOR 2022
34.00 15037.73 signalling installations jointly with the Railway representative at site at the stations/ LC gates c o v e r e d u n d e r various schedules of the Contract and ensuring that all t h e signalling gears a r e installed and adjusted as per the existing rules. The work also involves supply o f required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, r e l a y r o o m key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)."Testing and commissioning of LC gates SALEM DIVISION-S AND T/SOUTHERN RLY
390.00 circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above"
7.00 9547.85 or latest and submission of negatives in 80/90 gsm tracing paper in 'U' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 s e t s of prints s h a l l be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings s h a l l b e s u p p l i e d to Railways on 80/90 gsm tracing paper and 2 CDs.[2 interlocked sidings will b e considered equal for one loop line](Approved permanent w a y p l a n w i l l be supplied by Railways). a)Designing of Signalling plan in AUTO CADD - 'U' size - for stations upto 4 road
5.00 17147.65 or latest and submission of negatives in 80/90 gsm tracing paper in 'U' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 s e t s of prints s h a l l be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings s h a l l b e s u p p l i e d to Railways on 80/90 gsm tracing paper and 2 CDs.[2 interlocked sidings will b e considered equal for one loop line](Approved permanent w a y p l a n w i l l be supplied by Railways).b)Designing of Signalling plan in AUTO CADD - 'U' size - for stations from 5 to 8 roads SALEM DIVISION-S AND T/SOUTHERN RLY
1.00 28308.70 or latest and submission of negatives in 80/90 gsm tracing paper in 'U' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 s e t s of prints s h a l l be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings s h a l l b e s u p p l i e d to Railways on 80/90 gsm tracing paper and 2 CDs.[2 interlocked sidings will b e considered equal for one loop line](Approved permanent w a y p l a n w i l l be supplied by Railways). c)Designing of Signalling plan in AUTO CADD - 'U' size - for stations from beyond 8 roads
130.00 in AUTOCAD 2000 or latest (including contact numbers o n t h e circuit) and submission of negatives i n 80/90 gsm tracing paper in 'A3' size along with 2 copies and also the soft copy i n compact disks induplicate. First, 2 sets of p r i n t s s h a l l be supplied t o R a i l w a y s for checking. One set will be returned by Railways t o the contractor f o r making corrections in AUTOCAD. The final corrected drawings shall be supplied to Railways on 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs.(Approved Signalling plan will be supplied by Railways for preparing table of control. Approved table of control will be supplied by Railways for preparing circuits diagrams).a) Designing of circuits/TC in AUTO CADD 2000 - A3 SIZE
900.00 Wago block to Datalogger. Necessary Wagos required is included as per schedule
100.00 Datalogger. Necessary Wa g o s required is included as per schedule
2.00 28118.51 Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed)
78.00 No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
RDSO/SPN/165 /2012 Ver 3.0 or latest SALEM DIVISION-S AND T/SOUTHERN RLY
93.00 21381.60 DC/24-40V, 10A as per RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest
3.00 57921.89 A C , 1 . 5 K VA a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest or IRS:S 82-92
9.00 74455.98 A C , 2 K V A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest or IRS:S 82-92
3.00 29500.00 wired(without Integrated power supply as per RDSO/SPN/165 or latest). Necessary interface cable from IPS to ASM panel is not covered."
93.00 chargers, transformers, transformer rectifiers, invertors, D C - D C convertors etc., in the apparatus cases and wiring the same using wire PVC 7/1.4mm a n d 3/0.75mm copper as per the approved wiring diagram and painting of particulars in the inside of the doors of the apparatus cases. The work also includes provision o f protective arrangements i n bare terminals carrying high voltages. (Supply of power equipments is not included in this schedule).[Wire PVC 7/1.4mm and 3/0.75mm copper, protective arrangements, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].
17000.00 Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
12000.00 Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
610.00 or CE3P certified panduit or Systimax or R&M or AMP or Molex or Krone Or D-LinkMakes
8.00 13647.37 enclosure f o r armoured optical fi b r e cable c o n f o r m i n gt o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest
325.00 cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions o f Railway representative at site.) as per drawing enclosed
900.00 (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case c a p i n g a n d clamping on the w a l l / Ro o f t o p s / S h e l t e r s w i t h suitable clamping and hose to be provided where ever bends/ curves (PVC conduit/ Case capping and other accessories to be supplied by the contractor)
12500.00 except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) SALEM DIVISION-S AND T/SOUTHERN RLY
175.00 the Passenger Platform, trenching to a depth o f 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives a t site. (Laying of cables is not included in this schedule).
300.00 track crossing of cables, refilling of trench by ramming a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall b e f r o m t h e bottom o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule).
300.00 road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench b y r a m m i n g a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supplyo f D W C / R C C p i p e s with couplers/collars is not included in this schedule).
450.00 laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor.
300.00 laying in hard rocky area with off sets at both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. SALEM DIVISION-S AND T/SOUTHERN RLY
29000.00 cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s not included in this schedule).
12500.00 width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling."
325.00 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y r a m m i n g . T h e cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station l i m i t s throughout t h e cable route, diversions a n d a l s o a t every track/road crossing."
10.00 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n r e a r o f r e l a y rooms/ A F TC huts, apparatus cases etc. The work includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor].
1000.00 Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc . (Note: T h e pilot used for HDD should be of sufficient size to s u i t insertion o f H D P E / D W C p i p e o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a H D P E p i p e o r a n y other combination as directed by the site engineer) ( Supply o f HDPE pipe i s not covered in this schedule)"
4500.00 cable/Signalling c a b l e i n s i d e permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated H D P E pipe. ( This includes Transportation o f materials from nominated stores to site)
78.00 10722.72 Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC non AC immunizeda s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 or latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. SALEM DIVISION-S AND T/SOUTHERN RLY
39.00 13597.41 of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug i n type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g b o a r d s , r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram a n d painting the particulars.[Wire P V C copper, 3/0.75mm and
industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 -
condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, r e s i s t o r s , c o n d e n s e r s a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. d)Wiring o f Signal/ Point/ L C control circuit (up to 20 relays/Plug in type)
78.00 15009.60 Nos of KLCRs
2.00 9752.74 r a c k 500/210/140 Terminals capacity on teakwood base frame o f size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting a s p e r standard practice.(Supply of cable termination racks a r e not included in this schedule).[Foundation bolts and nuts with washers, cement, sand, stone jelly, teak wood base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Concreting and erection of cable termination rack 140/210 capacity SALEM DIVISION-S AND T/SOUTHERN RLY
850.00 rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper b u s b a r f o r supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n the PVC/ n y l o n s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm &
covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block)
100.00 rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper b u s b a r f o r supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n the PVC/ n y l o n s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm &
covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block i n cable termination rack (Per Unit = Per Fuse Block) SALEM DIVISION-S AND T/SOUTHERN RLY
2.00 3015.04 168/56 relay capacity using 'J' type bolts and painting of relay rack as per the instructions of Railway representative at site.(Supply of relay rack i s not covered i n this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, p a i n t a n d all other miscellaneous materials required for the work s h a l l b e s u p p l i e d b y the Contractor]. b)Concreting and erection o f relay rack - 56 capacity
100.00 with 2BA terminals, and wiring of relays as per Relay the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes w i r i n g o f c o n t a c t s f o r data logger and terminating them i n t a g blocks, provision of relay index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips i s not c o v e r e d i n this schedule). [Wire PVC 16/0.2mm copper, tag blocks, 2BA terminals, h a r d w o o d p l a n k o f size 600mmx 900mmx25mm w i t h decolum finish, MS a n g l e s o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, p h y n o l i c sheet 6mm t h i c k o f size 1200mmX1800mm with aluminium grooved channel frame f o r relay index board, paints, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor].
555.00 terminal blocks and wiring of additional relays Relay as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips and 50 w a y terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 2 5 m m t h i c k for fi x i n g resistors a n d condensers, soldering materials, b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w i r e supporting tray with cover of suitable size made of PVC, paint, varnish and a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] SALEM DIVISION-S AND T/SOUTHERN RLY
825.00 in the relay racks/apparatus cases as per the Relay approved circuit diagram using wire PVC 16/0.2mm copper. The work includes painting alterations and releasing the unwanted wires c a r e f u lly w i t h o u t disturbing the existing wiring.[Wire PVC 16/0.2mm copper, soldering materials, b u n c h i n g t h r e a d s , condensers, resistances a n d teakwood p l a n k f o r fixing the m a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor].
12500.00 Orange, width o f 250mm (10") by printing w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides
4500.00 (inner dia) with couplers
8.00 10502.00 mountable 1 2 Fi b r e management system ( F M S ) conforming t o RDSO/SPN/TC- 37/2000(rev-3 a m d t - 1 o r l a t e s t sim ila r to COMMSCOPE m a k e o r better, suitable for splicing and front patching 12F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required l e n g t h ( A l l o t h e r m a t e r ia ls r e q u i r e d for splicing are to be supplied by contractor)
8.00 4936.26 600mm x 600mm with complete accessories
61.44 a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre.
800.00 a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre.
450.00 a n d P B T F u s e b l o c k s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse
39.00 11333.10 and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another f o r t h e bac k door, fixing o f o n e hard wood s h e l f p l a n k 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, ' E ' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & n u t s a n d a l l other miscellaneous materials required for thework shall be supplied by the Contractor.] SALEM DIVISION-S AND T/SOUTHERN RLY
950.00 existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be r e p a i n t e d / c o r r e c t e d o n t h e d o o r s of a p p a r a t u s c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. T h i s w o r k i n c l u d e s c l o s i n g t h e opening create d f o r e n t r y o f n e w c a b l e s i n the apparatus cases with masonry brick work and sealing t h e bottom o f t h e apparatus cases/ cable termination racks with cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor]. (Per Unit = Per Terminal block)
4000.00 cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm t h i c k for terminal board to suit each apparatus c a s e , varnishing all teakwood items, fixing o f terminals/ fuse blocks o n the terminal board, drilling of necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n this schedule)." a)Termination o n 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) SALEM DIVISION-S AND T/SOUTHERN RLY
400.00 cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm t h i c k for terminal board to suit each apparatus c a s e , varnishing all teakwood items, fixing o f terminals/ fuse blocks o n the terminal board, drilling of necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n this schedule)." b)Termination o n P B T fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block)
900.00 cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves and also o n t h e inner side o f t h e doors of apparatus cases. After terminations are over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location) (Per Unit = Per Terminal block) SALEM DIVISION-S AND T/SOUTHERN RLY
200.00 cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of c a b l e s using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars o n sleeves and also o n t h e inner side o f t h e doors of apparatus cases. After terminations are over, t h e side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block)
10.00 G a t e Wa r n i n g equipment f o r e a c h level crossing g a t e , o n e o n e a c h r o a d warning signal, amplifier i n t h e apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting.(Electronic G a t e Warning Equipment and amplifier will be supplied by Railways).[All wiring, fixing and painting materials shall be supplied by Contractor].
78.00 same in LC/HP/FP Locks/SM slides
80.00 H a l f / Q uarte r s i z e ) w itho ut d a m a g e after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall b e accounted and stacked a t a place a s instructed by Railway representative at site.
120.00 73903.01 round the clock to attend the teething trouble of the installation along with SSE/JE after the i n s t a l l a t i o n h a s b e e n b r o u g h t into commissioning. T h e w o r k includes routine maintenance, failure restoration a s p e r the direction of the SSE/JE
200.00 S&T gears by deputation of Helpers/Unskilled Days Labour for executing additional S&T portion of t h e w o r k s . The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. SALEM DIVISION-S AND T/SOUTHERN RLY
120.00 g e a r sb y d e p u t a t i o n of Days Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The w o r k c a n i n v o l v e fixing, releasing, dismantling, replacement, painting or alteration o f vario us signallilng assets or parts, termination of cables, minor patch work on damages at location box, Plastering, Concreting b r i c k w o r k , w i r i n g alterations, cable jointing etc as per instruction of Railway representatives at size.
4000.00 a s p e r t h e i n s t r u c t i o n s o f Railway representative at site. The work also includes l o a d i n g a n d u n lo a d in g o f the materials a)Transportation o f Signalling materials upto 100kms
4000.00 than 100km
195.00 other machineries for regarding and levelling t h e formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as per the instruction o f Railway representative at site. Total 35130989.57
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .