Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-Finance 56 C 2 BIDHANNAGAR ROAD KOLKATA WEST BENGAL 700067 | KOLKATA | KOLKATA | WEST BENGAL | 700067 | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹13.8 L+₹15,358 (1.13%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹13.9 L+₹30,000 (2.20%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest |
| Sl No | Description | Qty | Unit | RS SYSTEMS AND PROJECTS L2 | DURGAPUR POWER L3 | BANERJEE ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Retro fitting of existing LT Panel of MCH Substation with charges of low rating Copper bar with necessary bending making hole fixing, overhauling old one & replacing the same with new nut, bolt, washer etc. as per rating of Main switches. | 1 | Item | 6,07,200 ₹6,07,200 | 6,06,900 ₹6,06,900 Lowest | 6,16,900 ₹6,16,900 |
| 2.00 | Supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse. (replacing existing Main switch) 250A, Make-Siemens (for LT Panel within MCH Substation) | 1 | Each | 18,526 ₹18,526 Lowest | 18,526 ₹18,526 Lowest | 18,526 ₹18,526 Lowest |
| 3.00 | 415A, Make-Siemens (for 250 KVA DG incomer, LT Panel within MCH Substation - 1 no, OPD Building panel- 2 nos, Medicine Store Feeder Pillar-1 nos) | 4 | Each | 23,524 ₹94,096 Lowest | 33,524 ₹1,34,096 | 23,524 ₹94,096 Lowest |
| 4.00 | 630A, Make-Siemens (Model No - 3KL8421-5UA00)(for 500 KVA DG incomer, LT Panel within MCH Substation) | 1 | Each | 55,857 ₹55,857 Lowest | 55,857 ₹55,857 Lowest | 55,857 ₹55,857 Lowest |
| 5.00 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 630A, Make- L&T (Cat. No. SK904920000) (for MCH building Panel) | 2 | Each | 51,458 ₹1,02,916 Lowest | 51,458 ₹1,02,916 Lowest | 51,458 ₹1,02,916 Lowest |
| 6.00 | Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/PWD Approved ) as per direction of EIC 4 core 185 sqmm (LT panel room interconnection) | 30 | Mtr | 3,857 ₹1,15,710 | 3,257 ₹97,710 Lowest | 3,257 ₹97,710 Lowest |
| 6.01 | 4 core 300 sqmm (500 KVA DG to LT panel 630A SFU) | 50 | Mtr | 5,406 ₹2,70,300 | 5,306 ₹2,65,300 Lowest | 5,306 ₹2,65,300 Lowest |
| 7.00 | Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. | 80 | Mtr | 166 ₹13,280 Lowest | 166 ₹13,280 Lowest | 166 ₹13,280 Lowest |
| 8.00 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 50 sqmm | 4 | Set | 246 ₹984 Lowest | 246 ₹984 Lowest | 246 ₹984 Lowest |
| 8.01 | 4 core 70 sqmm | 4 | Set | 265 ₹1,060 Lowest | 265 ₹1,060 Lowest | 265 ₹1,060 Lowest |
Tender Value
Refer Docs
EMD Value
₹9,900
Closing Date
3 Sept 2026, 1:55 pmClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Annual Maintenance estimate of the E.I. work at MCH Building of BSMC and H, under B.M.C Electrical Section-I, PWDte. Bankura.------ Repair of MCH LT Panel and OPD building 2 nos LT panel and MCH building 2 nos panel under BSMC and H, Bankura.
2026_WBPWD_5019314_1
WBPWDTE/AE/BMCESD/NIQ-15/Q of 2026-2027
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,900
Yes
10 Sept 2026
19 Aug 2026
7 Sept 2026
19 Aug 2026
3 Sept 2026
19 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Retro fitting of existing LT Panel of MCH Substation with charges of low rating Copper bar with necessary bending making hole fixing, overhauling old one & replacing the same with new nut, bolt, washer etc. as per rating of Main switches. | 1 | Item | - | - |
| 2 | Supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse. (replacing existing Main switch) 250A, Make-Siemens (for LT Panel within MCH Substation) | 1 | Each | - | - |
| 3 | 415A, Make-Siemens (for 250 KVA DG incomer, LT Panel within MCH Substation - 1 no, OPD Building panel- 2 nos, Medicine Store Feeder Pillar-1 nos) | 4 | Each | - | - |
| 4 | 630A, Make-Siemens (Model No - 3KL8421-5UA00)(for 500 KVA DG incomer, LT Panel within MCH Substation) | 1 | Each | - | - |
| 5 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 630A, Make- L&T (Cat. No. SK904920000) (for MCH building Panel) | 2 | Each | - | - |
| 6 | Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/PWD Approved ) as per direction of EIC 4 core 185 sqmm (LT panel room interconnection) | 30 | Mtr | - | - |
| 6.01 | 4 core 300 sqmm (500 KVA DG to LT panel 630A SFU) | 50 | Mtr | - | - |
| 7 | Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. | 80 | Mtr | - | - |
| 8 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 50 sqmm | 4 | Set | - | - |
| 8.01 | 4 core 70 sqmm | 4 | Set | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_5091420.xls
BOQ • 0.29 MB
2911.pdf
Additional Documents • 0.13 MB
OID.pdf
Other Document • 0.38 MB
Date_Corrigendum.pdf
PDF • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .