GE AF OJHAR
GE AF OJHAR
REPAIR/MAINT OF WATER SUPPLY INSTALLATION PIPE LINE, STREET LIGHT, DG SET, CRANE, FIRE ALARM EARTHING PITS AND OTHER CONNECTED WORKS AT CHAMERLENI AND BORGARD AND PROVN OF FRESH WATER SUPPLY THROUGH WATER BROUSOERS AT AF STN BORGARD.
2024_MES_645566_1
8162/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹54,000
Yes
1 Jun 2024
7 Mar 2024
6 Apr 2024
8 Mar 2024
4 Apr 2024
22 Mar 2024
Amount
M & L for Preventive Checks/Breakdown Maintenance/serviceing of DG set by deputing Skilled Service Mechanic to attend the DG set as per the requirement for carrying out scheduled Preventive checks/Breakdown maintenance for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:-
Supply and Fix in Replacement Diesel filter suitable for 75 KVA
Supply and Fix in Replacement Lub Oil filter suitable for 75 KVA
Supply and Fix in Replacement Air filter (inner and outer) suitable for 75 KVA.
Supply and Fix in Replacement Hose Pipe Set suitable for 75 KVA.
Supply and Fix in Replacement V belt Set for 75 KVA
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete
Supply and Fix in Replacement VMR Panel for 75 KVA.
Supply and Fix in Replacement Battery Charger 12V,10Amp SMPS Base
Dismantling and taking out the FIP (PT Pump Assy) for repairing by replacing the worn out gasket, filter, suction valve, discharge valve and fixing the same after calibration and testing complete as directed by Engr-in-charge of Gen set of capacity 75/40 KVA .
Dismantling and taking out the dfective self starter assembly from Gen set of capacity 75/40 KVA (12V/24V) form the DG set and re-fixing the same after repair works including replacing the spare parts such as carbon brushes, springs, spring holder bushes, bearings, or any other spare part not mentioned herein but essentially required for proper functioning of the starter assembly complete all as specified and directed.
Supply & Fixing flexible pressure pipe for lubricant oil and fuel for any size/capacity/model/make of DG set incl taking down old one etc complete all as specified.
Dismantling and taking out radiator from Gen set of capacity 75/40 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins, incl weilding of lekage portion and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as directed by Engineer-in-Charge.
M & L for Preventive Checks/Breakdown Maintenance/serviceing of DG set by deputing Skilled Service Mechanic to attend the DG set as per the requirement for carrying out scheduled Preventive checks/Breakdown maintenance for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:- (Major Spares Replacement will be Paid Seperately under respective items below) at DG Set 40 KVA Chamarleni.(2 Nos DG set )
Supply and Fix in Replacement Diesel filter suitable for 40 KVA
Supply and Fix in Replacement Lub Oil filter suitable for 40 KVA
Supply and Fix in Replacement Air filter (inner and outer) suitable for 40 KVA.
Supply and Fix in Replacement V belt Set for 40 KVA
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete
Supply and Fix in Replacement VMR Panel for 40 KVA.
Supply and Fix in Replacement Battery Charger 12V,10Amp SMPS Base
M & L for Preventive Checks/Breakdown Maintenance/serviceing of DG set by deputing Skilled Service Mechanic to attend the DG set as per the requirement for carrying out scheduled Preventive checks/Breakdown maintenance for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:- (Major Spares Replacement will be Paid Seperately under respective items below) at DG Set 15 KVA at chamarleni. ( 3 nos DG set )
Supply and Fix in Replacement Diesel filter suitable for 15 KVA
Supply and Fix in Replacement Lub Oil filter suitable for 15 KVA
Supply and Fix in Replacement Air filter (inner and outer) suitable for 15 KVA.
Supply and Fix in Replacement V belt Set for 15 KVA
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete
Supply only coolant concentrate Make : Valvoline
Material and labour for draining out old engine/lubrication oil from chamber of the DG sets, cleaning of chamber thoroughly and filling new engine/lubrication oil of grade 20W40 complete all as specified and directed.
Supplying, fixing lead acid battery, 12 volts, 180 AH with lead acid suitable for DG set including initial charging (Make- EXIDE / AMRON ) including connction and testing incl taking down old one complete as specified and directed .
Supply only distilled water for batteries.
Material and labour for servicing/repair of AMF Panel of DG Set 75/40 KVA capacity for smooth functioning of the same with renewal / repair of AMF panel, wiring control timer, engine starting relay, contact point repal, AMF relay, HRC fuse of existing rating inclding painting complate for DG sets installed at various pockets at Borgad all as specified and as directed. Note:- The rate quoted by the contractor shall be deemed to included the cost of all minor spares as or any other part not mentioned herein but essential required to make the AMF panel completely functional and no extra payment shall be made for the same.
S&F Current Transformer with CT ratio 100/5 as per sample.
S&F Contactor FP, 3 Phase 63 A FP , AC as per sample
S&F Contactor FP, 3 Phase 40 A FP , AC as per sample
Supply & Fixing in repairs "ON LOAD" type Change over switch 100 Amps TPN front handle operated, on existing LT/AMF Panels, suitable for three phase, 415V, 50 Hz AC supply of following ratings :- Make - L&T/Schneider/C&S/indoasian/HPL
Dismantling and taking out the dfective door lock assembly of any capacity of the DG set and re-fixing the same after repair works including replacing the defective spare parts as reqd at site. complete all as specified and directed.
Taking down old unserviceable street light fittings /high way light /flood light/Watch tower light ) of any type and capacity up to 15 mtr heights and deposited to MES store yard for further disposal.
Supply, Installation, Testing and commissioning LED street light fittings 70 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No TRP-409-70-57-SL-GL-NSG or equivalent in Havells/ Phillips.complete all as specified and directed by Engineer- in-charge..
Supply, Installation, Testing and commissioning LED street light fittings 45 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No CRP-409-45-57-ML 2-GL-NSG or equivalent in Havells/ Phillips/bajaj.complete all as specified and directed by Engineer- in-charge.
Supply, Installation, Testing and commissioning LED Flood light fittings 120 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-120- CDL/60-M or equivalent in Havells/ Philips.complete all as specified and directed by Engineer- in-charge.
Supply, Installation, Testing and commissioning LED Flood light fittings 80 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-80-WW CDL/60-M or equivalent in Havells/ Philips.complete all as specified and directed by Engineer- in-charge.
Supply & Fix in repair PVC perplex cover glove type with Base plate /holder not less than 8 inch dia suitable for Post top lantern including one nos 7/9 watt LED lamp complete all as specified and directed by Engineer- in-charge.Make - Bajaj / Surya/*havells.
Repairs to High mast light 15/30 Mtr high, by taking down the luminaires mounting frame mechanically and replacing the unserviceable items (paid separately) including lifting the superstructure after repairs and testing complete all as specified and as directed by Engr-in- Charge..
S&F in repair flat twin core 10 sqmm nominal cross sectional area multistand aluminium conductor cable over all PVC shathed 1100 volt grade Heavy duty cable complete all as specified
S&F in repair flat twin core 6 sqmm nominal cross sectional area multistand aluminium conductor cable over all PVC shathed 1100 volt grade Heavy duty cable complete all as specified
Supply & Fix in repair LED Post top lantern weather proof indirect lighting solution Make Cormpton Cat Pt No LPTC-40-CDL or equivalent in Havells/Bajaj.complete all as specified and directed by Engineer- in-charge.
Supply & Fix in repair Post top lantern decorative HERITAGE LED suitable 1X20 Watt retro LED with opel deffuser including LED 20 Watt of Make Crompton Cat Part No LPTH-20-CDL or equivalent in Havells/ Wipro.complete all as specified and directed by Engineer- in-charge.
Supply and fix in repair street light bracket 32/40 mm bore GI pipe/tubing light grade not less than 1.2 Mtr long band to shape with 2 nos MS clamps flat iron 50 x 5 mm for nuts, bolts and washers suitable for Steel/PCC Pole etc and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make- Prakesh surya/Swastik/Jindal
Material and labour for cable joint termination box PVC body housing suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge.
Supply and fix in repairs power contactor, ML-3type Three pole, 440 volt , Auxilary coil voltage 230 Volt, Make- L&T/Legrand/Semiens
Supply and fix in repairs Time digital switch with built in PCB for street light , Make L&T, type DIGICON or equivalent of GEC/ GIC/ Havells.
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable multistanded with aluminium conductor 1100V grade 4 core cross sectional area 10 sqmm all as specified and directed.
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable with aluminium conductor 1100V grade 2 core cross sectional area 10 sqmm all as specified and directed.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 38mm
Supply and fix 40mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
M&L for Preparation of old painted surfaces of PCC LT 9.0 Mtr long & painting two coats of cement base paint from top to bottom and painting with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, including existing cross arm/angle iron/clamps/brackets etc & marking of pole numbers in white on black background all as directed.
M&L for periodical maintenance/ brake down maintenance of Fire alarm system any type and make of different location of 793SU (Borgard top & chamerlene) ( Fire alarms, smoke detectors, fire panel , sesor etc ) by checking & Testing to ensure proper function compete all as specified and as directed by Engr-in-charge , comprising of the following. Testing of smoke detectors and fire alarms to be functional Cleaning of fire alarm and other parts to prevent dirt and dust buid-up Ckecking of sesors and wiring to be all functional of CTO Section Make Bosch-03 at Chamar leni.
All as per Item No-61 above but location Borgad Top Make - Bosch-01
Supply ,install,testing & commissioning Addressable photoelectric smoke detector with base Model No HFP-11+ DB-11 of Make Siemens, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning addressable manual call point Model No HMS-S of Make Siemens, complete all as specified & as directed by Engineer-In Charge
Supply ,install,testing & commissioning control relay for module for hooter Model No HTRI-R of Make Siemens, complete all as specified & as directed by Engineer-In Charge.
Supply and lay 2 core 1.5 sq mm armoured FRLS copper cable for interconnecting devices in PVC conduit of 20 mm dia,complete all as specified & as directed by Engineer-In Charge
M&L for carrying out physical inspection and measurement of individual earth pit resistance of each earth pit, every month located in area and maintain the record of its reading month wise and submit to the office monthly for measuring the resistance of individual electrode of LV distribution system and other non-DG/ Transformer by fall of potential test in case fall of potential method is not possible at certain locations then measurement of earth pit resistance shall be carried out in stake less method using current and voltage clamps.() Nos earth pit located in different area of this station shall be measured in each month or all as directed. Pit for measurement of pit resistance including necessary excavation in any type of soil, or braking of hardstanding for inserting of spikes complete all as directed by Engineer-in-Charge. The rate also include to inspect and measure resistance of any type of earth( like conventional or chemical, strip or wire any size) complete. Note- Minimum 22 Earthings per working day and 100 % within a month to be cheked and testing will be carried out, testing equipment should be calibrated and certified from appropriate Govt Authority. Testing of earth resistance should be carried out in presense of the users and record should be furnished to the AGE E/M Office on daily basis, Failing which a recovery @ Rs 500 per eathing per day will be recovered as penalty.
Repair of old earthing for improvement of earth resistance by removing of old pit Chemeber from existing site , disconnecting all earth electrode of any type and size excavated the pit and removing old existing earth plate any type, cleaning the same and burried directly in ground with new bolts,nuts ,washer and check nut of galvanized steel,filling adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode and including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) The material as salt, charcoal, Magnesium sulphate,GI Plate, wire mesh funnel will be measured and paid seprately.
Supply only Salt
Supply only Char coal
Supply only Magnesium sulphate
Supply only Back fill compound (SGI Engineer or equvalent )
Supply only Wire mesh funnel
Supply & fix earth continuty conductor or main earthing lead of 25 x 3 mm copper strip.
Dismantling and taking down dislocated/de-shaped/loose earth contunity conductor down or roof conductor in any position for re-fixing properly or for replacement complete including UNSV insulators/clamps/ saddles ets Aluminum strip of any size. Note :- The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top and at lateral faces of existing hangers upto height of 25 Mtrs.
Supply & Fix 25 x 3 mm aluminium strip ( Roof conductor or down conductor) above ground level fixed to wall/ roof duly insulated fixed on and including new porcelain insulators with clamping device or recessed or chases or burried in ground/ floor or drawn in conduit / pipe or fixed to poles or any other indicated situation or for loop earthing etc. Note :- i) The consecutive distance between porcelain insulator will not be more than 40 cm. ii) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top and at lateral faces of existing hangers upto height of 25 Mtrs.
Re-fixing the taken down aluminium strip on roof top/on wall/lateral faces fixed on new porcelain insulator including new GI bolt, nut, washer provide at a distance not more than 40 Cm consecutively. Note :- i) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top at lateral faces of existing hangers upto height of 25 Mtrs. i) The consecutive distance between porcelain insulator will not be more than 40 iii) The cost of porcelain insulators will be paid under relivant item here in under but cost of GI bolt nut, washer etc is deemed to be included under quoted rates.
M&L for GI tubing light grade with all fitting laid in trenches or fixed to wall or ceiling with clamps or fixed to floor complete all as specied and directed of size 40 mm bore.Make : Tata/Jindal/Prakash Surya/Apollo.
M&L for Air termination, single pointed aluminium rod 12 mm dia and 300 mm long, includind dismantling and taking out old unservicable termination complete all as specified and as directed.
M&L in repairs for PCC block on roof top comprising 1:3:6 of required size at places where directed & laying,clamping the strip any size secured on the block with suitable size GI bolt duly grouted, nut bolt washer etc.
M&L for test point terminal block insulated from wall or external surface made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screws complete fixed on ebonite sheet 6mm thick fitted on MS flat 50x5mm bent to shape etc complete all as specified and as directed.
M&L in repairs to earthing pit chamber including replacement of PCC chamber, cement concret pit with cast iron miled steel frame embedded in the massonery enclouser finished flushed & PCC cover 10 mm thick (300mmx300mm having locking arrengment hinged to PCC frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, complete all as directed.
Supply only PVC insulator for GI/Aluminium strip supporter adequate to accomadate strip of 32 mm with fasteners complete all as specified and directed.
M&L for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.
M&L for yearly Inspection of cranes by checking & testing all parts /seafty deviceincluding Load testing and provide inspection report /certificate from authorised rep complete all as specified for the complete with the testing load as recommended by OEM for the rated tonnage of crane for the specific period complete with and including arrangement for safe test load for 0.5 to 2.0 ton cranes . Note :- Load testing is inclusive of shiffting /Transporting the load place to place, unloading will be arranged by the contractor including required ropes,manpower etc for handilling the load.
Repair maintenance of HOT operated travelling (HOT) cranes, once in a month of crane up to 20 mtr span, 0.5 ton to 1 ton capacity, medium duty floor operated comprising of Hoist motor , long travell , installed at Borgad Top including carry out periodical services as per ,repair /maintenance of unserviceable damaged parts such as bearing bushes all type of shoes headers, / broken MS Parts, safety parts, mechanically safety lock , including all connected accessories complete with push button ,inclusive repair of harness wiring of control panel , minor repair to panel ,for safety and smooth functioning of Cranes, cutting wall making good disturbed surface with masonry work to make the existing surface, cable as per requirement or safety operation of cranes, maintenance of unserviceable /worn out parts such as warm wheel, warm shaft, bushes, thrust bearing and necessary packing including cleaning, alignment of gear box assembly after repair/replacement of worn-out parts re-assemble and fixing with existing machine with proper alignment complete maintenance, binding of loose wire at control panel and painting to rust portion of crane.
Excavation in trenches n. exc 1.5 Mtr width and n.exc 1.5 mtr deep for foundation, laying GI pipes in hard and dense soil and getting out,complete all as specified and as directed by Engineer-In-Charge.
Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 cm levers of soil, complete all as specified and as directed by Engineer-In-Charge.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.
Taking up or down old rusted water tubing and connections fixed to wall floor, celing for bore of 15 mm dia , complete all as specified and as directed by Engineer-In-Charge.
All as per item no-90 but bore 20 mm dia
All as per item no-90 but bore 25 mm dia
All as per item no-90 but bore 40 mm dia
All as per item no-90 but bore 50 mm dia
Supply & Fix GI water tubing medium grade with all fitttings and fixed to wall, floor,in trenches, ceiling for bore of 15 mm diameter, complete all as specified and as directed by Engineer-In-Charge.
All as per item no 95 above but of bore 20 mm dia
All as per item no 95 above but of bore 25 mm dia
All as per item no 95 above but of bore 40 mm dia
All as per item no 95 above but of bore 50 mm dia
Fixing only old serviceable water tubing medium grade received from item No 5 here in before and connected with new fittings of medium grade as required including cleaning, cutting, threading and fixed to wall, floor, ceiling for bore of 15 mm diameter , complete all as specified and as directed by Engineer-In-Charge.
All as per item no 100 above but of bore 20 mm dia
All as per item no 100 above but of bore 25 mm dia
All as per item no 100 above but of bore 40 mm dia
All as per item no 100 above but of bore 50 mm dia
Supply & Fix in replacement of Bronze gate valve (Hex type) ISI marked screwed both ends of 50 mm diameter Art No 1006 of Make: Zoloto or Equivalent in SEIKO/GEM complete all as specified and as directed by Engineer-In-Charge.
All as per item no 105 above but of bore 40 mm dia
All as per item no 105 above but of bore 25 mm dia
All as per item no 105 above but of bore 20 mm dia
All as per item no 105 above but of bore 15 mm dia
Supply & fix in repair Contactor ML-02 Aux coil voltage 230 V , Make L&T or Equivalent in Siemens/Standard complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. item no 110 above but Contactor ML-03,Aux coil voltage 230 V
All as per Sl.item no 110 above but Contactor ML-04, Aux coil voltage 230 V
Material & Labour for run lead joint suitable for 150 mm dia spigot and socket end pipe including necessary excavation, cutting of existing pipe etc complete all as specified and as directed by Engineer-In- Charge
All as per Sl. item no 113 above but suitable for 100 mm dia spigot and socket end pipe
All as per Sl. item no 113 above but suitable for 80 mm dia spigot and socket end pipe
Supply and fix in repair fully automatic star delta starter complete with operating coil 230 volts, 3TF52- 02-0AP0 ,2 NO+ 2 NC suitable for 7.5 HP motor of Make Siemens or equivalent in L&T/Legrand complete all as specified & as directed by Engineer-In-Charge.
Dismantling old unserviceable valve chamber & Material & Labour for construction of valve chamber of size 0.90x0.90x0.90 mtrs internal dimension complete of brick masonary of 23 cm thick in cement mortar 1:6 on PCC 1:4:8 foundation 75 mm thick using 40 mm graded stone aggregates & coping in PCC having wall thickness of 0.26 mtrs 1 :3:6 10 mm thick at the top of brick wall using 20 mm graded stone aggregates and 10 mm thick plastering in cement mortar 1:4 on exposed brick or concrete surfaces & MS cover of 3.15 mm thickness including 40 mm×40mm× 6 mm angle iron frame fixed with the same size of angle iron hold fast,handle with locking arrangement & two coats of synthetic enamel paint over one coat of red oxide primer on steel surface and two coats of white wash on plastered concrete surface ,complete all as specified and as directed by Engineer-In-Charge.
All as per item no 117 aove but of size 1.20x1.20x1.20 mtrs internal dimension complete
Dismantling and taking out old unserviceable CI sluice valve from existing position and Supply & Fix CI sluice valve ISI marked PN-1 confirming to IS14846 both ends flanged with stainless steel stem with high tensile gun metal parts, iron wheel head check nuts etc including jointing with rubber gaskets, nuts, bolts and washer of sizes 80 mm dia Art No 1079A of Make:Zoloto or Equivalent in BIR/VENUS/UPADHAYA complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.119 here in before but of sizes 100 mm dia Art No 1079A of Make:Zoloto or Eqivalent in BIR/VENUS/UPADHAYA ,complete all as specified and as directed by Engineer-In-Charge.
All as per Sl. Item No.119 here in before but of sizes 150 mm dia Art No 1079A of Make:Zoloto or Eqivalent in BIR/VENUS/UPADHAYA ,complete all as specified and as directed by Engineer-In-Charge.
Material & Labour for structral steel work with MS channel ,angles,tees,beam,plate,pipe for fabricationof ladder ,manhole ,valve chamber,railing including fabrication work i.e welding,cutting drilling,jointing work and painting two coats of synthetic enamel paint over one coat of red oxide and fixing same at desire location, complete all as specified & as directed by Engineer-in Charge
Material & labour for fitting for spigot socketed CI pipes Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc,) Tee pieces single branch. "Y" juction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 300 mm bore including welding the same at desired location & taking out unserviceable fitting from existing position ,complete all as specified and as directed by Engineer-In-Charge.
Supply & Fix Cast iron detachable joint(mechanical joint) of 80 mm dia,complete including all excavation work and curtting of existing pipe etc all as specified and as directed by Engineer-In-Charge.
All as per item no 124 above but of size of 100 mm dia,
All as per item no 124 above but of size of 150 mm dia,
Material & labour to collect water sample from 793 SU chamarlene area in container & sending it to govt approved NABL lab , to carry out chemical analysis as well as organoleptic & physical & General Parameters & bacteriological parameter Including Residual free Chlorine test from approved lab Every month & rate quoted are deemed to be quoted with this item.) (Note: - Report from approved NABL lab shall be submitted by 15th of the Month.)
Supply and laying in repairs Cast iron pipes of bore 80 mm dia, with spigot and socket ends Centrifugally cast, class LA ,Tyton joint complete all as specified and as directed by Engineer-In-Charge.
All as per item no 128 above but of bore 100 mm dia,
All as per item no 128 above but of bore 150 mm dia,
Material & Labour for disconnecting the motor from pumpset & transporting it to workshop rewinding the electric motor after dismantaling the stator and rotor, removing the damaged winding, cleaning the slots, warnishing the stampings, slots and rewindung the stator with super enamelled best quality copper winding wire of the suitable gauge and number of turns/coils as per the existing/manufactureres winding pattern of electric motor of 7.5 HP. Warnishing, drying and reasssembling, testing etc, complete all as specified and as directed by Engineer-In-Charge.
Material & Labour for Repairs to centrifugal pump set of Make :Kirloskar 7.5 HP capacity,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set with complete all as specified and directed by Engineer-in-Charge.
Repairs to vacuum pump of 50 LPM capacity Kirloskar coupled with electric motor 3 PH 440V , 50Hz, 1450 RPM after disconnecting the electric connections,transporting the pumpset to workshop and transporting the pumpset to workshop ,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Pumping out water and sediments from overhead resorvoir of capacity 75000 ltrs situated at chmarleni area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the OH resorvoir including the walk way arround, by removing all the debries & clearing the bushes,vegetation/weeds/salvage/scrap .
Material & Labour for Pumping out water and sediments from the semi underground sump of capacity 250000 ltrs situated at chamarleni area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the sump including the walk way arround by removing debries & clearing bushes ,vegetation/weeds around 50 metre radius of sump,Prepration of surfaces, Applying two coats of white wash inside the sump, and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome ,pumpset & associated pipeline with synthetic enamel paint as directed by Engineer-In-Charge .etc ,and marking a portion of size not exceeding more than 1 Sq M with black syntetic enamel paint over a coat of primer and writing in white synthetic enamel paint the sump capacity,date of cleaning , due for cleaning & painting all the valve chambers & valves and valve cover with synthetic enamel paint and marking flow direction area and area of supply etc. complete all as specified and directed by Engineer-In- Charge.
Material & Labour for Pumping out water and sediments from the semi underground sump of capacity 120000 ltrs situated at chamarleni area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the sump including the walk way arround by removing debries & clearing bushes ,vegetation/weeds around 50 metre radius of sump,Prepration of surfaces, Applying two coats of white wash inside the sump, and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome ,pumpset & associated pipeline with synthetic enamel paint as directed by Engineer-In-Charge .etc ,and marking a portion of size not exceeding more than 1 Sq M with black syntetic enamel paint over a coat of primer and writing in white synthetic enamel paint the sump capacity,date of cleaning , due for cleaning & painting all the valve chambers & valves and valve cover with synthetic enamel paint and marking flow direction area and area of supply etc. complete all as specified and directed by Engineer-In- Charge.
Material, labour & suitable vehicle for making one trip for transortation of 4000 ltrs of clean & hygenic potable water, in water bowser three times in a week ( checked by MI room, borgard) to be delivered to borgard hill top approximately 22 kms from borgard(chamerlene area) passing through plain and hilly area (of 3100 feet height) & hair pin turns. (Note: The vehicle provided shall be fully insured updated with all vehicle paper. The driver & helper should have suitable life insurance. ii) The water to be delivered three times a week . (Note : Failing to provide water bowser at borgard top under any circumstances whatsever, contractor shall be penalise for paying 10000 per trip in the form of recovery. Water shall be loaded form MES pump house at chamarlene with locking arrangement, representative of user unit to ensure its potability and shall be submitted to sub division on monhtly basis. If water tanker found rusted/ not suitable to carry the potable water, the sane trip shall be rejected by MES and no claim on this account shall be admissible by the MES) )
K R Electricals
United Enterprises
SHRI SULAI ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .