CWE Rajouri
HQ CWE Rajouri PIN 900129 C/o 56 APO
REPAIR TO SUMMER APPLIANCES, VOLTAGE STABILIZER AND SOLAR WATER HEATER AT NAUSHER UNDER GE 862 EWS
2023_MES_634405_1
CWE/RAJ-49/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹21,000
Yes
26 Apr 2024
26 Dec 2023
3 Feb 2024
26 Dec 2023
29 Jan 2024
10 Jan 2024
Amount
Window AC Disconnecting, taking down of window AC's of capacity 1/1.5 TR for repair , maintenace, comprissing of following works at different locations & refixing, commissioning & testing of the same complete all as specified & directed :- (i) Inspecting, taking down, brushing cleaning with blower & including acid/detergent wash of condenser and cooling coil. (ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting for leakage in the system. (iv) Checking the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of all electrical parts. (vii) Testing the machine for satisfactory operation. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respective item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of window type AC.
S & F in replacement of air filter of window type AC of capacity 1/1.5 TR as per existing Make & Model as required at site complete all as specified and directed.
S&F in replacement cooling coil as per existing Make and Model for window AC 1/1.5TR & including soldering/welding, commissioning & testing complete all as specified and directed.
Disconnecting & taking down of window type AC 1/1.5 TR of any Make and Re-fixing the same after replacement of condenser coil as per existing Make and Model & including soldering/welding, commissioning & testing complete all as specified and directed.
S & F in replacement of fan and blower motor as per existing Make & Model and suitable for window air conditioner of capacity 1 TR complete all as specified and directed.
S & F in replacement of fan and blower motor as per existing Make & Model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
S & F in replacement of blower as per existing Make & Model and suitable for window air conditioner of capacity 1 TR complete all as specified and directed.
S & F in replacement of blower as per existing Make & Model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
S & F in replacement of fan blade as per existing Make & Model and suitable for window air conditioner of capacity 1 TR complete all as specified and directed.
S & F in replacement of fan blade as per existing Make & Model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
Split AC M & L for servicing and maintenance of split type AC's of capacity 1 TR/ 1.5 TR/ 2.0 TR comprising of the following works installed at different locations, including testing complete all as specified and directed :- (i) Checking and rectifying the Indoor/outdoor units for noise free operation. (ii) Checking and rectifying the electrical connection & water leaking problem. (iii) Cleaning the Out-door unit condenser and In-door unit cooling coil with air blower and latest technology cleaning system. (iv) Greasing/Oiling of condenser fan motor and blower motor. (v) Checking and rectifying any kind of refrigerant leakage. (vi) Checking the serviceability of remote control unit. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respective item (here-in-after) of BOQ. (ii) Make(s) of AC's to be repaired are (Voltas, Hitachi, Lloyd, Godrej, Bluestar) (iv) Providing Common tools, Special Tools, latest cleaning devices and Connected accessories is the responsibility of contractor.
S & F in replacement of capacitor combo running 36/45 mfd for split/ window type AC unit as per existing or as required at Site complete all as specified and directed.
S & F in replacement of running capacitor 60/80 mfd for split/window type AC unit as per existing or as required at Site complete all as specified and directed.
S & F in replacement of indoor blower fan motor, single phase, 230 Volt of split/window type AC Suitable for 1.5/2 TR capacity complete all as specified and directed.
S & F in replacement of burnt compressor of capacity 1.5 TR of split type AC unit and re-fixing the same after replacement from the company make original compressor as per existing Rotary Type Make & Model and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in replacement of burnt compressor of capacity 2.0 TR of split type AC unit and re-fixing the same after replacement from the company make original compressor as per existing Rotary Type Make & Model and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
M & L for repair to leaking area of split type AC unit of capacity 1.5 TR and including dehydration, gas charging with gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same
M & L for repair to leaking area of split type AC unit of capacity 2.0 TR and including dehydration, gas charging with gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in replacement of air filter of indoor unit for split type AC units of capacity 1.5 TR as per existing Make & Model complete all as specified and directed.
S & F in replacement of air filter of indoor unit for split type AC units of capacity 2.0 TR as per existing Make & Model complete all as specified and directed.
S&F in replacement of insulation for Split AC Copper Tube 5/8 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (Under minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
S & F in replacement of 3 core copper PVC insulated flexible cable of size 4.0 Sqmm, 1100 Volts and conforming to IS: 694 complete all as specified and directed.
S & F in replacement of swing motor of indoor unit as per existing Make & model for split type AC, 1.5 TR complete all as specified and directed.
S & F in replacement of swing motor of indoor unit as per existing Make & model for split type AC, 2 TR complete all as specified and directed.
S & F in replacement of suction line (1/4") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S & F in replacement of discharge line (5/8") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S & F in replacement of PCBs indoor/ outdoor units as per existing Make & model for Split type AC of Capacity 1.5 TR complete all as Specified and Directed.
S&F in replacement of PCB (printed control board) Units as per existing make & model for split type AC of capacity 2.0 TR complete all as specified and directed.
S & F in replacement of electronic cordless remote control unit as per existing Make & model of split type AC's of capacity 1.5 TR complete all as specified and directed.
S & F in replacement of electronic cordless remote control unit as per existing Make & model of split type AC's of capacity 2.0 TR complete all as specified and directed.
S & F in replacement of Flexible PVC drain pipe of size 15mm bore & suitable for Split type AC of Capacity 1.5/2.0 TR complete all as specified and directed.
S & F in replacement of outdoor unit fan blade as per existing Make and model & suitable for Split type AC of Capacity 2 TR complete all as Specified and directed.
S & F in replacement of outdoor unit fan blade as per existing Make and model & suitable for Split type AC of Capacity 1.5 TR complete all as Specified and directed.
S & F in replacement of outdoor unit condenser fan motor as per existing Make & model and suitable for 1.5 TR capacity air conditioner complete all as specified and directed.
S & F in replacement of outdoor unit condenser fan motor as per existing Make & model and suitable for 2 TR capacity air conditioner complete all as specified and directed.
S & F in replacement of copper condenser coil as per existing and suitable for 1.5 TR capacity of air conditioner, outdoor unit, ISI marked and including gas charging complete all as Specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in replacement of copper condenser coil as per existing and suitable for 2 TR capacity of air conditioner, outdoor unit, ISI marked and including gas charging complete all as Specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in replacement of Low pressure valve suitable for 2TR/1.5TR capacity air conditioners as per existing Make & model complete all as specified and directed.
S & F in replacement of four way valve as per existing Make & model and suitable for 2.0 TR / 1.5 TR capacity of air conditioner, ISI marked complete all as specified and directed.
S&F in replacement of AC refrigerant charging Pin NRV Valve complete all as specified.
M & L for removal and shifting of Split AC's of capacity 1.5/2.0 TR with indoor, outdoor and including all the connected accessories after pumping down the gas, refitting, topping up the gas, testing and commissioning complete all as specified and directed.
S & F in replacement of ducting insulation sheet (9mm thick) for insulating refrigeration pipe line for 1.5/2.0 TR capacity of air conditioner complete all as specified and directed.
S & F in replacement of brass flare union connector (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
Water cooler M & L for servicing & maintenance of water coolers of any capacity comprising of the following works at different location complete all as specified and directed :- (i) Inspection, taking down, opening, dismantling, descaling, brushing & cleaning of storage tanks. (ii) Examination of water tightness, leak proof of storage tank after cleaning. (iii) Carry out operation of all stop cock, push cock, float valve etc. (iv) Inspect overflow and remove blockage if any. (v) Check and correct earth continuity of electric items. (vi) Check thermostat and functioning test. (vii) Inspect drain pipe and remove blockage if any. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of water cooler after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respective item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of water coolers.
S & F in replacement of thermostat switch as per existing Make & Model for water cooler of any Capacity complete all as specified and directed.
S & F in replacement of overload protector relay as per existing Make & Model for compressor of water cooler of any capacity as reqd at site complete as specified and directed.
S & F in replacement of condenser fan motor, single phase suitable for water cooler of capacity 40/80 Ltrs complete all as specified and directed.
S & F in replacement of condenser fan motor, single phase suitable for water cooler of capacity 60/120 Ltrs complete all as specified and directed.
S & F in replacement of 15mm bore brass float valves accessories as per existing Make and Model & suitable for water coolers at site, ISI marked complete all as specified and directed.
Disconnecting and taking down water coolers of capacity 40/80 Ltrs & 60/120 Ltrs of any make and size for repairs & including detection of leakage in the system rectifying the same, dehydration & recharging of gas (R-22/R-134A/Environmental Friendly Gas) suitable for compressor model & testing the water cooler for smooth & satisfactory operation complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in replacement of CP push cock of size 15mm dia as per existing Make & model, ISI marked complete all as specified and directed.
S & F in replacement of capacitor 10 Mfd as per existing Make & model, ISI marked for water cooler of any capacity complete all as specified and directed.
S & F in replacement of burnt compressor as per existing original Make & model and suitable for water cooler of capacity 40/80 Ltrs and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in replacement of burnt compressor as per existing original Make & model and suitable for water cooler of capacity 60/120 Ltrs and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
Deep Freezer M & L for repair & maintenance of Deep Freezer of capacity 200 to 320 Ltrs comprising of the following works at different location complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting the leakage in the system. (iv) Checking of the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of all electrical parts. (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of Refrigerator after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respective item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of Deep freezer.
S&F in replacement fan motor suitable for deep freezer of capacity 320 Ltr, 230 Volts single phase as per existing make and model all as directed as site.
S & F in replacement of burnt compressor as per existing Company Make original & model and suitable for deep freezer of capacity 200-320 Ltrs and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S&F in replacement of start relay suitable for deep freezer of capacity 320 Ltr as per existing make and model all as directed as site.
S&F in replacement of relay with capacitor 6 mfd sutaible for 320 Ltr deep freezer.
S & F in replacement of single pole and neutral sheet metal enclosure with a two pin and earth plug and socket and including one MCB SPN 20 Amps, 240 Volt, MCB, 'C' curve type with AC box, rupturing capacity 10 KA complete all as specified and directed.
S & F in replacement of MCB single pole 6 to 32 Amp, 'C' curve having rupturing capacity 10 KA complete all as specified & directed.
S & F in replacement of metal clad plug 20A for AC's as per existing Make and size complete all as specified & directed.
S & F in replacement of metal clad socket 20A for AC's as per existing Make and size complete all as specified & directed.
REFRIGERATOR Dismantling refrigerator of any make any capacity for taking out compressor/condenser/freezer unit etc. for repair/ replacement of unserviceable parts, cleaning condenser/ freezer unit of foreign particle and descaling with carbon dioxide gas to ensure smooth flow of refrigerant gas, reassembling the appliance, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately.
S&F in replacement of compressor unit 1/8 HP for 165/175 Ltr refrigerator complete all as specified and directed
S&F in replacement of compressor unit 1/6 HP for 280 to 310 Ltr refrigerators complete all as specified and directed
S&F in replacement of PCB (printed control board) and sensor suitable for refrigerator of capacity from 165 to 310 Ltr as per existing make and model complete all as specified and directed.
Supply and filling of refrigerant gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters complete all as specified and directed.
S&F in replacement of copper capillary tube for refrigerator of capacity 165 to 310 Ltr as per existing make and model complete all as specified.
S&F in replacement starting relay for refrigerator of capacity 165 to 310 Ltr as per existing make and model complete all as specified and directed
S&F in replacement over load protector for refrigretor of capacity 165 to 310 Ltr as per existing make and model complete all as specified and directed
S&F in replacement themostat for refrigretor of capacity 165 to 310 Ltr as per existing make and model complete all as specified and directed
S&F in replacement freezer compartment including hinges for door and all petty accessories for refrigerator of capacity 165 to 310 Ltr as per existing make and model including filling of suitable type and quantity of gas complete all as specified and directed
Solar water heater M&L for over hauling & servicing the solar water heater of any capacity 100 LPD by repair/replacing the spares and blocks in the solar cells removed by the acid cleaner, descaling and arresting leakages to be ractified including replacement of unserviceable/damages part complete all as specified and directed. Note:- Defective parts will be measured & paid separately but all the petty items such as nuts bolts, washers, etc used for repair are included in the quoted rate.
Supply and fixing of Gasket set for solar water heater panel suitable for 100 LPD capacity.
Supply and replace flat plate collector panel for solar water heater suitable for 100 LPD capacity and testing complete.
S & F of heating element 3000W with thermostat of suitable type and size for solar water heater all as specified.
Voltage stabilizer Dismantling electric connection of any make any capacity voltage stablizer for inspecting of burnt out relay, circuit board, etc. for repair/ replacement of unserviceable parts, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately.
S & F in replacement electromagnetic relay for capacity of 2.5 KVA stabilizer, complete all as specified and directed.
S & F in replacement electromagnetic relay for capacity of 3 KVA stabilizer, complete all as specified and directed.
S & F in replacement of electric circuit board for capacity of 2.5 KVA stabilizer, complete all as specified and directed.
S & F in replacement of electric circuit board for capacity of 3 KVA stabilizer, complete all as specified and directed.
S & F in replacement of electric transformer of capacity upto 3 KVA suitable for voltage stabilizer, complete all as specified and directed.
M/S PARSHOTAM KUMAR GUPTA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .