Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.0 L+₹38,155 (0.92%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹42.2 L+₹53,687 (1.29%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹42.5 L+₹84,820 (2.04%)Rejected-Finance 1A 52 NETAJI SUBHASH NAGAR E M BY PASS SOUTH 24 PARGANAS WEST BENGAL 700100 | KOLKATA | WEST BENGAL | 700100 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹42.6 L+₹96,654 (2.32%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
28 Mar 2022, 6:00 pmClosed
COMMANDER WORK ENGINEER, DINJAN
COMMANDER WORK ENGINEER, DINJAN
SPECIAL REPAIRS AND REPLACEMENT OF LIFT CONTROL SYSTEM, REPAIR MAINT OF ELCTRICALLY OPERETATED LIFTS AND CENTRAL AC PLANT AND ALLIED SERVICES AT 162 MH DINJAN UNDER GE DINJAN
2022_MES_512605_1
84052E8
Open Tender
Civil Works
Item Rate
180 days
GE DINJAN
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE DINJAN
₹75,000
19 Apr 2022
8 Mar 2022
30 Mar 2022
8 Mar 2022
28 Mar 2022
23 Mar 2022
9 Mar 2022 - 18 Mar 2022
Amount
M&L for repairs to electrically operated lift (Stretcher lift) and its control/safety devices alongwith work services mentioned below by shutting down the lift at each floor position dismantling the railed/grilled doors in position of the car cabin and the floor doors (total 04 doors) with necessary cuttings, welding and making good the track to run the car cabinet smoothly complete checking after replacing spares/control units all as specified and as directed by the Engr-in-Charge (Note: the quoted rates dimmed to be incl necessary PCC works to make good the replaced door entrance cabin, other sky folding mtrl to execute inside the lift well etc and all other wks to complete the fixing of new sliding doors), complete all as specified and directed.
S&F testing and commissioning lift automatic door panel (Centre openable/side slideable panel door with embedded railed glass visor to enable paitent to view the movement of the car cabin) made of 1.5 mm stainless steel 900 opening set complete all as specified and as directed.
M&L testing and commissioning of car door cabin header automatic door stainless steel (Centre openable/side slideable panel door with embedded railed glass visor to enable paitent to view the movement of the car cabin) complete all as specified and as directed.
M&L testing and commissioning of car cabin front panel SS complete all as specified and as directed.
M&L testing and commissioning of controller panel board for automatic doors modified complete with required copper wiring as per OEMs instructions, Main IC, 13 relay card and other connected spares complete all as specified and as directed.
M&L in replacement of travelling cable 24 core 1 sqmm multistranded copper cable (suitable for stretcher and passenger lifts) complete all as specified and as directed (Make : Macrothern).
Supply only ''Timer ON relay'' complete all as specified and directed.
Supply only ''Timer OFF relay'' complete all as specified and directed.
Supply only ''Conractor 9 Amps (Siemens make)'' complete all as specified and directed.
Supply only ''MCB SP 16 Amps to match the existing'' complete all as specified and directed.
Supply only ''MCB Fuse 1T Amps to match the existing'' complete all as specified and directed.
Supply only ''Gear Oil'' complete all as specified and directed
Supply only ''steel wire rope 8 mm dia'' complete all as specified and directed.
Supply only NR-4 top and bottom speed governor pulley complete all as specified and directed.
Supply only ''TC relay 110 Volt DC 15 Amps 4 Pole'' complete all as specified and directed
Supply only ''O/E/N relay 24 volt DC'' complete all as specified and directed
Supply only ''two phase transformer (415 volts AC)'' complete all as specified and directed
Supply only 'Door shoes for MCD'' complete all as specified and directed
Supply only ''Door bearing for MCD'' complete all as specified and directed
Supply only ''Door bearing for auto door'' complete all as specified and directed
Supply only ''Door drive belt V type'' complete all as specified and directed
Supply only ''Read switch'' complete all as specified and directed
Supply only ''Micro Switch 15A 250 Volts'' complete all as specified and directed.
Supply only ''Toggle switch '' complete all as specified and directed
Supply only ''Rubber Coupling'' complete all as specified and directed
Supply only ''Micro switch 15 Amps, 250V'' complete all as specified and directed
Supply only ''Landing Switch'' complete all as specified and directed
Supply only ''COP switch'' complete all as specified and directed
Supply only ''APCLD Card'' complete all as specified and directed
Material and labour for preparation of old painted mild steel (MS) surfaces of passenger and stretcher lift (all inside and outside door of the lift) including electric motor, floor of lift and cabin fan of the lifts, putlying steel surfaces to obtain smooth and even finish and applying two coats of synthetic enamel paints by brush application complete all as specfied and directed
M&L for long Travel 4 Nos Motor alongwith 4 Nos Gear Box complete dismantling overhauling, heat varnishing grassing & gear oil change and fillup complete all as specified and as directed by the Engr-in-charge
M&L for cross travel motor & gear box greasing & gear oil change and fillup complete all as specified and as directed by the Engr-in-charge
M&L for Hist motor gear box grasing & oil change and fillup complete all as specified and as directed by the Engr-in-Charge
M&L for cross travel trolly full checking and greasing complete all as specified and as directed by the Engr-in-charge
M&L for Pendent oily fully check free and greasing complete all as specified and as directed by the Engr-in-charge
M&L for Pannel board 4 Nos drive all contractor all relay checking complete all as specified and as directed by the Engr-in-charge
M&L for guarder repairing, long travel & testing complete all as specified and as directed by the Engr-in-charge
M&L for long travel all guarder checking and grinding as required complete all as specified and as directed by the Engr-in-charge
M&L for cross travel guarder checking complete all as specified and as directed by the Engr-in-charge
S/F s*2000VVVF AC drive crank No 2 change 400 volts complete all as specified and as directed by the Engr-in-charge
M&L for cross travel motor rewinding 3 phase 5 HP DC convert 110 V make bharat bijlee 2 Nos bearing chane complete all as specified and as directed by the Engr-in-charge
M&L for timer on Relay 3 Nos crank I & II complete all as specified and as directed by the Engr-in-charge
M&L for timer off relay complete all as specified and as directed by the Engr-in-charge
M&L for contractor 9 Amps cap set of 4 Nos complete all as specified and as directed by the Engr-in-charge (Make simens)
M&L for MCB single pole 16 Amps cap complete all as specified and as directed bh the Engr-in-charge Make CRS electric limited
M&L for HRC fuse 32 Amps csp complete all as specified and as directed by the Engr-in-charge
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Central air cooled AC plant of capacity 3x28TR (incl 1 standby), by cleaning of airfilters, condensor cleaning with coil cleaner, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring,greasing of blower motor, checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results,in presence of Engineer-in-Charge, complete all as specified and directed. [Central AC plant of capacity 3x28 TR,Make- M/s Batliboy Ltd (installed at 162 MH)
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Package type air cooled AC plant of capacity 3 x5 TR(incl 1 standby) by cleaning of airfilters,condensor cleaning with coil cleaner,cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring, greasing of blower motor,checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results, in presence of Engineer-in-Charge complete all as specified and directed.[Package type air cooled AC plant of capacity 3 x 5 TR, Make - M/s Batliboy Ltd installed at 162 MH].
De-scaling of water cooled condenser unit of 28 TR capacity by non-chemical approved water treatment system after opening end covers and removing scales using nylon brush and re-assembling the same by replacing rubber gasket and washing by circulating fresh water complete all as specified and directed.
De-scaling of water cooled condenser unit of 5 TR capacity by non-chemical approved water treatment system after opening end covers and removing scales using nylon brush and re-assembling the same by replacing rubber gasket and washing by circulating fresh water complete all as specified and directed.
Cleaning of cooling coil of AHU, capacity 56 TR including flushing with suitable high pressure gas and chemicals as approved/recommended by the manufacturer complete all as directed.
Cleaning of cooling coil of AHU, capacity 5 TR including flushing with suitable high pressure gas and chemicals as approved/recommended by the manufacturer complete all as directed.
Supply only "Carbon brush for 40 HP" for induction motor.
Supply only “Ball bearing No 6313” for induction motor.
Supply only “Ball bearing No 6308” for induction motor & pumps.
Supply only “Ball bearing No 6206” for induction motor & pumps.
Supply only “Ball bearing No 6204” for induction motor & pumps.
Supply only “Ball bearing No 6309” for induction motor.
Supply only “Ball bearing No 6208” for induction motor.
Servicing/overhauling of open type Compressor Unit of capacity 28 TR (Make : Kirloskar Pneumatic) after complete dismantling compressor unit to its smallest components/parts in presence of MES representative and display all the parts/ components of compressor for inspection of Engineer-in-Charge to ascertain the serviceability of existing parts including carrying out maintenance and check as per the Maintenance Manual along with the following other repairs :- (a) Draining out of compressor oil, charging and refilling after repair/ servicing. (b) Dismantling of heads of compressor, replacement of gasket, repairs head assembly by adjusting valves and replacement of worn out components complete all as directed by Engineer-in-Charge. (c) Dismantling, de-carbonizing and degreasing of all parts such as piston assembly, heads, crank case, crank shaft, etc. (d) Checking all rotary and stationery parts (existing) for its smooth functioning. (e) Assembling of compressor complete with old serviceable parts and replacement of unserviceable parts by new parts where necessary complete all as directed by Engineer-in-Charge. Testing of compressor after servicing/ overhauling as per direction by Engineer-in-Charge [Note: - (i) Any parts required to be replacement during servicing/ overhauling of compressor shall be measured and paid separately here-in-after as supply only rates. (ii) Any minor parts such as split pins, screws, washers, etc. required for commissioning of work shall be supplied by the tenderer and rate for the same shall deemed to be included in the unit rate quoted against the item].
Supply only "Discharge oil filter" for open type compressor unit of 28 TR capacity.
Supply only "Side cover gasket set" for open type compressor unit of 28 TR capacity.
Supply only "Top cover gasket set" for open type compressor unit of 28 TR capacity.
Supply only "Back cover gasket set" for open type compressor unit of 28 TR capacity.
Supply only "Piston rings set (set of 02)" for open type compressor unit of 28 TR capacity.
Supply only "Suction valve reed" for open type compressor unit of 28 TR capacity.
Supply only "Suction valve spring" for open type compressor unit of 28 TR capacity.
Supply only "Suction valve 'O' ring" for open type compressor unit of 28 TR capacity.
Supply only "Discharge valve reed" for open type compressor unit of 28 TR capacity.
Supply only "Discharge valve spring" for open type compressor unit of 28 TR capacity.
Supply only "Connecting rod big end bearing nuts bolts" for open type compressor unit of 28 TR capacity.
Supply only "Rotary shaft seal" for open type compressor unit of 28 TR capacity.
Supply only "50 mm bore suction valve packing Teflon 3 mm thick (plate type)" for open type compressor unit of 28 TR capacity.
Supply only "40 mm bore discharge valve packing Teflon 3 mm thick (plate type)" for open type compressor unit of 28 TR capacity.
Supply only "Crank case heater cap 200 Watt" for open type compressor unit of 28 TR capacity.
Supply only "Compressor oil pump" for open type compressor unit of 28 TR capacity.
Supply only "Piston assembly" for open type compressor unit of 28 TR capacity.
Supply only "Connecting rod" for open type compressor unit of 28 TR capacity.
Supply only "Gudgen pin" for open type compressor unit of 28 TR capacity.
Supply only "Cylinder liner" for open type compressor unit of 28 TR capacity.
Supply only "Cylinder liner washer Aluminium" for open type compressor unit of 28 TR capacity.
Supply only "Discharge valve plate" for open type compressor unit of 28 TR capacity.
Supply only "Oil pump suction strainer (Compressor 28 TR)" for open type compressor unit of 28 TR capacity.
Supply only "Suction line strainer fine net" for open type compressor unit of 28 TR capacity.
Supply only "O" Ring for compressor rotary shaft seal" for open type compressor unit of 28 TR capacity.
Supply only "Gasket for suction line header" for open type compressor unit of 28 TR capacity.
Supply only "Service valve suction rubber bush" for open type compressor unit of 28 TR capacity.
Supply only "Service valve discharge rubber bush" for open type compressor unit of 28 TR capacity.
Supply only "Service resistance set fitted with porcelain tube for slip ring assembly" for open type compressor unit of 28 TR capacity.
Supply and topping up compressor oil by supplying new compressor oil and charging oil complete all as specified and directed. [Make : SITALN-68 or Equivalent]
Supply and charging of refrigerant R-22 to AC plant and package type AC complete all as specified and directed.
Supply and fixing of driving V belt of size “C-128” degree for compressor unit including taking out existing unserviceable one complete all as specified and directed. [Make : Fanner/Dunlop]
Supply and fixing of driving V belt of size “B-86” for booster fan including taking out existing unserviceable one complete all as specified and directed. [Make: Fanner/Dunlop]
Supply and fixing of driving V belt of size “B-91” for blower motor including taking out existing unserviceable one complete all as specified and directed. [Make : Fanner/Dunlop]
Supply and fixing of driving V belt of size “A-67” for fresh air motor including taking out existing unserviceable one complete all as specified and directed. [Make : Fanner/Dunlop]
Supply and fixing driving V belt of size “A-29” for blower motor package including taking out existing unserviceable one complete all as specified and directed.
Supply and fixing HBC fuse link din type 80 KA, 125 Amps round bolted connection type/knife edge blade contact type for switch fuse units as per existing including taking out the unserviceable fuse complete all as specified and directed. [Make : L&T or AE]
Supply and fixing HBC fuse link 80 KA, 63 Amps round bolted connection type/knife edge blade contact type for switch fuse units of make as per existing including taking out the unserviceable fuse complete all as specified and directed. [Make : L&T or AE]
Supply and fixing HRC fuse link 80 KA, 32 Amps round bolted connection type/knife edge blade contact type for switch fuse units as per existing including taking out the unserviceable fuse complete all as specified and directed. [Make : L&T or AE]
Supply and fixing HRC fuse link 80 KA, 20 Amps round bolted connection type/knife edge blade contact type for switch fuse units as per existing including taking out the unserviceable fuse complete all as specified and directed. [Make : L&T or AE]
Supply and fixing HRC fuse link 80 KA, 4 Amps round bolted connection type/knife edge blade contact type for switch fuse units as per existing including taking out the unserviceable fuse complete all as specified and directed. [Make : L&T or AE]
Supply and fixing HRC fuse link 80 KA, 2 Amps round bolted connection type/knife edge blade contact type for switch fuse units as per existing including taking out the unserviceable fuse complete all as specified and directed. [Make : L&T or AE]
Supply & fixing fuse base with grip 63 Amps as per existing including taking out old unserviceable one complete all as specified and directed. [Make : L&T]
Supply & fixing fuse base with grip 32 Amps as per existing including taking out old unserviceable one complete all as specified and directed. [Make : L&T]
Supply & fixing fuse base with grip 20 Amps as per existing including taking out old unserviceable one complete all as specified and directed. [Make : L&T]
Supply and fixing base fuse grip for HRC fuse type FNB sheet metal enclosure cap 250 Amps TPN 415 Volts including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing in repair HP-LP cut out switch, M-15 complete all as specified and directed. [Make: INDFOSS/DANFOSS]
Supply and fixing in repair oil presser switch, type MP- 55, completes all as specified and directed. [Make – INDFOSS/DANFOSS]
Supply and fixing in repair loading and unloading valve electrically operated complete all as specified and directed.
Supply and fixing in repair filter drier for package AC complete all as specified and directed.
Supply and fixing in repair power contactor, type ML-1.5 complete all as specified and directed. [Make: L&T]
Supply and fixing in repair power contactor, type ML-2 complete all as specified and directed. [Make- L&T]
Supply and fixing in repair power contact kit without coil for contactor ML 1.5 to ML 1 complete all as specified and directed. [Make :- L & T]
Supply and fixing in repair standard operating coil AC 230 Volt suitable for power contactor ML 1.5 complete all as specified and directed.
Supply and fixing in repair neon type bulb for panel mounting indicator lamp fitting, pin type, complete all as specified and directed.[Make : NTN]
Supply and fixing in repair brass contact points (set of three) for oil immersed starter cap, 40 HP, complete all as specified and directed.
Supply and fixing in repair thermal overload relay, 16 Amps for package type AC complete all as specified and directed.
Supply and fixing in repair AHU runner shaft bearing NTN-P-206J complete all as specified and directed.
Supply and fixing in repair liquid line Teflon sheet 3mm thick plate type complete all as specified and directed.
Supply and fixing in repair 230 Volt, single phase, 3 KW strip heater complete all as specified and directed.
Supply and fixing terminal connector for 6 sq. mm cable including taking out existing unserviceable one complete all as specified and directed. [Make- L&T]
Supply and fixing in repair toggle switch, 5 amps, 230 Volt complete all as specified and directed.[Make : KAYCEE/L & T]
Supply and fixing in repair Hand shut valve, 1/4", Brass complete all as specified and directed.
Supply and fixing in repair bearing for fresh air unit block type model 2307 K complete all as specified and directed.
Supply and fixing in repair filter Drier, ¼” complete all as specified and directed.
Supply and fixing in repair booster fan shaft, bearing with socket, model SN – 610 complete all as specified and directed.
Supply and fixing in repair angle valve, brass, ¼” complete all as specified and directed.
Supply and fixing in repair bearing for package air conditioner unit, capacity 5 TR blower motor, model SV-505 M complete all as specified and directed.
Supply and fixing in repair liquid line filter strainer complete all as specified and directed.
Material and labour for flushing out of complete central air conditioning system by nitrogen gas and making the system leak proof and vacuuming complete all as specified and directed.
Charging only R-22 gas to the system obtained during pump down of AC plant all as directed by Eng-in-Charge.
Supply and fixing in repair motor terminal plate for 15 HP motor complete all as specified and directed.
Supply and fixing in repair motor terminal plate for 5 HP motor complete all as specified and directed.
Diamntling and taking down the old wooden and the MS base sump complete from site in replacement of corrosion proof fibre glass structure, casing , distribution basin and collection basin included cooling tower fully galvanised support for central AC Plant of model mentioned at item no 1 above with the tech specifications as : tower of dimentions 1905 x 1581 x 1964mm with pumping head from base tower coloumn 1.749m-WC,with fan of dia 42 (1.067)m -01 No with rpm @740speed duly belt driven incl motor power rating 3 (2.2) (HP(KW) three phase 415 volts +/- 10%/3/50+/-5% current characterisitics TEFC, IP-55 weatherproof FRP casing , Louvers and elevatorswith PVC, integral fill, nozzels of PVC made, Fan cylinder and basin of FRP, Fan blade of Engineering plastic, with HDG Steel nuts & bolts complete with cap of 224 USGPM, 97.5 hot water temp 0F, cold water temp 900F, design wet bulb temp 830F complete all as specified incl testing, commissioing with necessary connections to the exisitng water tubing connections all as specified and as directed (note : rates quoted shall be deemed to be incl necessary minor modifications to match the exisitng plumbing/ tubing system of the water supply and incl erection of tower to the exisiting platform etc all as specified
Diamntling and taking down the old wooden and the MS base sump complete from site in replacement of corrosion proof fibre glass structure, casing , distribution basin and collection basin included cooling tower fully galvanised support for package AC Plant of model mentioned at item no 2 above with the tech specifications as : tower of dimentions 953 x 1581 x 1324mm with pumping head from base tower coloumn 1.109m-WC,with fan of dia 24 (0.61)m -01 No with rpm @654speed duly belt driven incl motor power rating 0.5 (0.37) (HP(KW) three phase 415 volts +/- 10%/3/50+/-5% current characterisitics TEFC, IP-55 weatherproof FRP casing , Louvers and elevatorswith PVC, integral fill, nozzels of PVC made, Fan cylinder and basin of FRP, Fan blade of Engineering plastic, with HDG Steel nuts & bolts complete with cap of 40 USGPM, 97.5 hot water temp 0F, cold water temp 900F, design wet bulb temp 830F complete all as specified incl testing, commissioing with necessary connections to the exisitng water tubing connections all as specified and as directed (note : rates quoted shall be deemed to be incl necessary minor modifications to match the exisitng plumbing/ tubing system of the water supply and incl erection of tower to the exisiting platform etc all as specified
Supply and fixing in repair four pole terminals for cable connection M-150AH including 35 sq. mm 3.5 core un-armored XLPE copper cable 2 meter including lugs complete all as specified and directed.
Material and labour for preparation of old painted mild steel (MS) surfaces of water tank, cooling air duct GI pipe of any size and length and applying two coats of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted surfaces of compressor unit 28 TR (including motor, oil immersed, starter, condenser, control panel board, liquid line pipe, discharge line pipe mounting channel etc) and applying two coats of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted surfaces of induction motor pump of capacity 2 HP / 5 HP capacity by using steel scrubber and applying two coats of synthetic enamel paint complete all as specified and directed.
S & F Suction line service valve 50mm (TAL Make) for Central AC Plant
S & F Discharge line service valve 40mm (TAL Make) for Central AC Plant
STANDARD ELECTRIC WINDERS
R D Enterprises
M/s. R. K. Trading Company
M/s GANDHESWAR PHUKAN
Bimal Trading Company
NChetia and Sons Trading
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .