Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹23.5 L+₹74,720 (3.28%)Rejected-AOC | L2 | Rejected-AOC Being not L1 bidder | |
| 3 | L3₹23.9 L+₹1.1 L (4.91%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Being not L1 bidder | |
| 4 | L4₹29.0 L+₹6.2 L (27.2%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L4 | Rejected-AOC Being not L1 bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical No Slow Progress in WLR |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
2 Oct 2020, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINTENANCE OF CERTAIN CENTRIFUGAL MONOBLOCK PUMP SETS INSTALLATION IN THE AREA OF AGE U No II UNDER GE U WATER SUPPLY DELHI CANTT 10
2020_MES_374778_1
GE/WS/D-98 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹50,000
Yes
4 Nov 2020
4 Sept 2020
5 Oct 2020
4 Sept 2020
2 Oct 2020
18 Sept 2020
Amount
Demolition of cement concrete unreinforced, in ground floor or pavings below or above ground level from foundation of pump sets including removal of debris from site complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates as in foundation, sub base or mass concrete complete all as specified and as directed.
Labour for Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of following capacities from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
Opening the electric induction motor of following capacity including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including all other insulating material to make it functional complete all as specified and as directed . Note:- Copper winding wire of approprioate guage will be measured in supply only
Supplying and Fixing in replacement of Motor Terminal Box of following capacity complete all as specified and as directed.
Supplying and Fixing in replacement of Motor Terminal Connection Plate of following capacity complete all as specified and as directed.
Supplying and Fixing in replacement of CI Sleeve on Bearing Housing of following capacity complete all as specified and as directed.
Labour for Disconnecting and De-coupling the Centrifugal pump of following capacity from foundation after opening /cutting the rusted nuts, bolts etc including transporting the pump to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and as directed.
Opening the centrifugal pump of following capacity, repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed. Note:- Spare Parts required shall be measured & paid spaerately.
Supply Only in replacement of spare parts for Centrifugal pump of 5-15 HP Capacity complete all as specified and as directed. NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller
Pump shaft SS (AISI-410)
CI Casing bearing DE/NDE
CI interstage ring
CI stuffing box bush
CI Gland Plate
Eye bolt with nut
CI Shaft sleeve
Gasket Packing Set
Gland packing champion
Impeller key
coupling key
water liquid deflector
CI bearing cartridge DE/NDE
CI bearing plate
Coupling nut
MS Stud with nut
Labour only for Remetling of pump shaft, turning and balancing
Supply Only in replacement of spare parts for Centrifugal pump of 20-30 HP Capacity complete all as specified and as directed. NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller
pump shaft SS (AISI-410)
CI Casing bearing DE/NDE
CI interstage ring
CI stuffing box bush
CI Gland Plate
Eye bolt with nut
CI Shaft sleeve
Gasket Packing Set
Gland packing champion
impeller key
coupling key
Water liquid deflector
CI bearing cartridge DE/NDE
CI bearing plate
coupling nut
MS Stud with nut
Labour only for Remetling of pump shaft, turning and balancing
Supply Only in replacement of spare parts for Centrifugal pump of 40-50 HP Capacity complete all as specified and as directed. NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller
pump shaft SS (AISI-410)
CI Casing bearing DE/NDE
CI interstage ring
CI stuffing box bush
CI Gland Plate
Eye bolt with nut
CI Shaft sleeve
Gasket Packing Set
Gland packing champion
Impeller key
coupling key
water liquid deflector
CI bearing cartridge DE/NDE
CI bearing plate
Coupling nut
MS Stud with nut
Labour only for Remetling of pump shaft, turning and balancing
Supply Only in replacement of spare parts for Centrifugal pump of 60-75 HP Capacity complete all as specified and as directed. NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller
pump shaft SS (AISI-410)
CI Casing bearing DE/NDE
CI interstage ring
CI stuffing box bush
CI Gland Plate
Eye bolt with nut
CI Shaft sleeve
Gasket Packing Set
Gland packing champion
Impeller key
Coupling key
Water liquid deflector
CI bearing cartridge DE/NDE
CI bearing plate
Coupling nut
MS Stud with nut
Labour only for Remetling of pump shaft, turning and balancing
Supply Only in replacement of spare parts for Centrifugal pump of 90-125 HP Capacity complete all as specified and as directed. NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller
pump shaft SS (AISI-410)
CI Casing bearing DE/NDE
CI interstage ring
CI stuffing box bush
CI Gland Plate
eye bolt with nut
CI Shaft sleeve
Gasket Packing Set
Gland packing champion
impeller key
coupling key
water liquid deflector
CI bearing cartridge DE/NDE
CI bearing plate
coupling nut
MS Stud with nut
Labour only for Remetling of pump shaft, turning and balancing
Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out monoblock pump set capacity upto 10 HP from foundation/base plate of pump set after opening the nuts, bolts etc and transporting the pump to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
Opening the monoblock motor upto capacity 10 HP , taking down/out the burnt winding wire and cleaning the slots including rewinding the monoblock motor with super enamelled copper winding wire of existing gauge ,weight etc. including all other insulating material complete all as specified and as directed. Note :- Copper winding wire of appropriate gauge shall be measured and paid separetely
Opening the monoblock pump of capacity upto 10 HP , repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed. Note :- Spare Parts required shall be measured & paid spaerately.
Supply Only in replacement of spare parts for Monoblock pump of upto 10 HP Capacity complete all as specified and as directed. NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller
Mechanical Seal
water Seal
GM Shaft sleeve
gland packing sheet
water liquid deflector
impeller Nut
MS Stud with nut
Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out dewatering motor pump vertical type from underground sump of capacity 2 HP after opening the nuts, bolts etc and transporting the pump to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out hydropneumatic pump set from base plate of capacity 1.5 HP after opening the nuts, bolts etc and transporting the pump to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out centrifugal pump set from base plate of capacity 2.5 HP after opening the nuts, bolts etc and transporting the pump to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
Opening of dewatering motor from underground sump of capacity 2 HP including taking down/out the burnt winding wire , cleaning the slots ,rewinding the motor with super enamelled copper winding wire of existing gauge ,weight etc. including all other insulating material and re-assembling the same in original position complete all as specified and as directed .
Opening of motor from hydropneumatic pump set of capacity 1.5 HP including taking down/out the burnt winding wire , cleaning the slots ,rewinding the motor with super enamelled copper winding wire of existing gauge ,weight etc. including all other insulating material and re-assembling the same in original position complete all as specified and as directed .
Opening of motor from centrifugal pump set of capacity 2.5 HP including taking down/out the burnt winding wire , cleaning the slots ,rewinding the motor with super enamelled copper winding wire of existing gauge ,weight etc. including all other insulating material and re-assembling the same in original position complete all as specified and as directed .
Opening of dewatering motor pump from underground sump of capacity 2 HP and repairing the motor by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed .
Opening of hydropneumatic pump set of capacity 1.5 HP and repairing the motor by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed .
Opening of motor from centrifugal pump set of capacity 2.5 HP andrepairing the motor by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed .
Supply Only in replacement of spare parts for 1.5 to 2.5 HP Capacity AMA porter pump/Non-clogging centifugal pump set complete all as specified and as directed . NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller-501
CI Impeller-503
Maintenance kit -501/503
Cable kit with float switchfluid level controller-501/503 SE
Suction plate
Plug for motor cable
Installation kit-ama porter 500
stainless steel rotor sleeve
stainless steel rotor shaft -410
Remetailing of rotor & turning/grinding
GM suction ring
Prrof jointing of submersible cable
CI suction chamber
Repairing of stamping of stator
mechanical seal set upper & lower
O ring set
insulation kit
Supplying and assembling super enamelled copper winding wire of appropriate gauge suitable upto 125 HP capacity Motor complete all as specified and as directed
Supply and Fixing in replacement of Ball bearing No 6205 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6212 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6305 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6306 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6307 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6308 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6309 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6310 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6311 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6312 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6313 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6314 complete all as specified and as directed.
All as per serial item No 30 here-in-before but of No 6315 complete all as specified and as directed.
Supply and Fixing in replacement of double Ball bearing No 3307 complete all as specified and as directed.
All as per serial item No 43 here-in-before but of No 3309 complete all as specified and as directed.
All as per serial item No 43 here-in-before but of No 21309 complete all as specified and as directed.
Supply and Fixing in replacement of Roller bearing NU-312 complete all as specified and as directed.
Supplying and Fixing in replacement of CI Sleeve on Bearing Housing of following capacity complete all as specified and as directed.
All as per serial item No 46 here-in-before but of No NU-314 complete all as specified and as directed.
All as per serial item No 46 here-in-before but of No NU-316 complete all as specified and as directed.
All as per serial item No 46 here-in-before but of No NU-318 complete all as specified and as directed.
Supply and fixing spare tyre for coupling type as under, after taking down/out as existing at site complete all as specified and as directed.
Type TC/P/011
Type TC/P/013
Type TC/P/014
Type TC/P/015
Type TC/P/017
Type TC/P/018
Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 5-20 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 25-50 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 60-75 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 90-125 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
Supply and Fixing in replacement MS base channel of size as exists including cutting, welding and making hole including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing bearing plate bolt of size 8 mm dia , 100 mm long after taking down/out plate as existing at site complete all as specified and as directed.
Supply and Fixing in replacement of MS foundation bolts with nuts and washers, size 20mm dia , 450 mm long complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-1.5, 415 Volts, 50 HZ range 25 Amps complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-2, 32 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-3, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-6,110 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-10, 200 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
S & F in replacement of Bimetal over load replay type MN 2, relay range 14-23 Amp complete all as specified and as directed.
S & F in replacement of Bimetal over load relay type ML 2/3, relay range 20-32 Amps complete all as specified and as directed.
S & F in replacement of Bimetal over load relay type ML 2/3, relay range 28-42 Amps complete all as specified and as directed.
S & F in replacement of Bimetal over load relay type ML 4/6, relay range 45-75 Amps complete all as specified and as directed.
S & F in replacement of Bimetal over load relay type ML 5, relay range 66-110 Amps complete all as specified and as directed.
S & F in replacement of Bimetal over load relay type MN-12, CT operated relay range 90-150 Amps complete all as specified and as directed.
Supply and fixing in replacement Amp Meter Analog type 0 to 60 Amp of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement Amp Meter Analog type 0 to 100 Amp of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement Amp Meter Analog type 0 to 200 Amp of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement Amp Meter Analog type 0 to 400 Amp of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement Volt Meter Analog type 0 to 500 Amp of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement of Indicating light RYB LED type complete all as specified and as directed.
Supply and fixing in replacement Amp Meter Digital type of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement Volt Meter digital type of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement PVC insulated FRLS singlestranded copper conductor wire of following size, 1100 volts complete all as specified and as directed.
4.00 sqmm, single core
6.00 sqmm, single core
10.00 sqmm, single core
16.00 sqmm, single core
25.00 sqmm, single core
35.00 sqmm, single core
Supply and fixing in replacement of Thermal contactor type MNX-12, in electric panel of motor complete all as specified and as directed.
Supply and fixing in replacement of Thermal contactor type MNX-18 in electric panel of motor complete all as specified and as directed.
Supply and fixing in replacement of Thermal contactor type MNX-25 in electric panel of motor complete all as specified and as directed.
Supply and fixing in replacement of Thermal contactor type MNX-32 in electric panel of motor complete all as specified and as directed.
Supply and fixing in replacement of Thermal Overload Relay MN 6 to 10 complete all as specified and as directed.
Supply and fixing in replacement of Thermal Overload Relay MN 10 to 16 complete all as specified and as directed.
Supply and Fixing in replacement Electronics Timer 3-30 seconds, Type ST100, 415 volts, complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 100 Amps with breaking capcity 16 KA , 415 volts, complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 160 Amps with breaking capcity 25 KA , 415 volts, complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 200 Amps with breaking capcity 36 KA , 415 volts, complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 250 Amps with breaking capcity 36 KA , 415 volts, complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 400 Amps with breaking capcity 50 KA , 415 volts, complete all as specified and as directed.
Supply and fixing in replacement of fully automatic star delta starter type ML-1.5 complete all as specified and as directed.
Supply and fixing in replacement of fully automatic star delta starter type ML-2 complete all as specified and as directed.
Supply and fixing in replacement of fully automatic star delta starter type ML-4 complete all as specified and as directed.
Supply and fixing in replacement of fully automatic star delta starter type ML-6 complete all as specified and as directed.
Supply and fixing in repair copper terminals lugs medium duty for following items :-
(iii) 6.0 mm
An amount of Rs 195702.00 shall be deducted from BOQ on account of schedule of credit
DHAIRYAE ENTERPRISES
Sumit Enterprises
Rahul Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .