| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹32.0 L+₹8.3 L (34.9%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹32.6 L+₹8.9 L (37.7%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹34.9 L+₹11.2 L (47.4%)Rejected-Finance LODHI NAGAR NEAR TEACHERS COLONY GALI NO 4 MAHOLI ROAD MATHURA U P 281004 | MATHURA | MATHURA | UTTAR PRADESH | 281004 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹45.8 L+₹22.1 L (93.3%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | Ms Kamal Kant Agarwal L2 | M/s A.K. ENGINEERS L1 | M/S S S CONSTRUCTION L3 | BUILDTECH ASSOCIATES L5 | ISHWAR ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down of window/split AC 1.5/2.0 tonne of any make opening complete. Servicing of AC components carefully such as cleaning with chemical solution and soft nylon brush and change of air filters,tightnining of loose screw, checking wiring connection and tightening the same and rectification of defects if any assembling the same with body balancing and fixing in position and testing in the presence of Engineer-in-Charge complete all as specified and as directed.
Note :- (i) Cost of unserviceable major parts as required shall be measured and paid separetaly under relevant items under this BOQ.
(ii) The Spare Part item (s) required to be changed/replaced in appliance to make the appliance efficient workable shall of same makes/manufacturers of appliance.
(iii) Servicing of same AC shall be carried out for two times in whole contract period and shall be measured as one unit "Each Job" for two services. Register shall be maintained for these services. | 135 | Each Job | 300 ₹40,500 Lowest | 500 ₹67,500 | 390 ₹52,650 | 430 ₹58,050 | 500 ₹67,500 |
| 2.00M&L for servicing / cleaning of the following appliances which included cleaning the body, storage tank, blow out the condenser coils with air blower, alignment and greasing, cleaning of fan bushes thorough checking of wiring and rectification of defects and leakages, cleaning of blockages of drain out-let connections, testing for smooth operation in presere of Engineer-in-Charge to entire satisfaction all as specified and directed. Note: (i) This service shall be carried out for three times in whole contract period and shall be measured as one unit "Each Job" for three services. Register shall be maintained for these services. (ii) Cost of Gas charging as in topping up as required to maintain desired gas pressure is deemed to be included in the unit rate quoted for this item. | ||||||||
| 2.01 | Water coolers of capacity upto 280 Ltrs | 40 | Each Job | 400 ₹16,000 | 300 ₹12,000 | 290 ₹11,600 Lowest | 430 ₹17,200 | 300 ₹12,000 |
| 2.02 | Refrigerator of capacity upto 320 Ltrs | 15 | Each Job | 400 ₹6,000 | 400 ₹6,000 | 450 ₹6,750 | 430 ₹6,450 | 300 ₹4,500 Lowest |
| 2.03 | Deep Freezers of capacity upto 425 Ltrs | 15 | Each Job | 1,000 ₹15,000 | 500 ₹7,500 | 700 ₹10,500 | 600 ₹9,000 | 300 ₹4,500 Lowest |
| 3.00M&L for checking and rectify the leakage if any in the following appliances which included Testing leakage in system by injecting Nitrogen gas upto 300 PSI, rectification leaking spots/joints with gas welding work, filter anti moistoring agent, soldering, brazing, copper capillary tubing of reqd size and cleaning and flushing out complete system with gas making the system leak proof,vaccumising the complete system and supply and charging R-22/R407 refrigerant gas qty as required for the following type and capacity of appliances:- Note:- No extra cost shall be paid to the contractor for gas charging (any numbers of times) in case of leakage with in six months of initial gas charging except in case where external damage to the plant is noticed. Register shall be maintained for these leakage. | ||||||||
| 3.01 | Water coolers of capacity upto 280 Ltrs | 22 | Each | 300 ₹6,600 | 800 ₹17,600 | 290 ₹6,380 Lowest | 860 ₹18,920 | 900 ₹19,800 |
| 3.02 | Refrigerator of capacity upto 320 Ltrs | 12 | Each | 500 ₹6,000 | 1,000 ₹12,000 | 480 ₹5,760 Lowest | 950 ₹11,400 | 900 ₹10,800 |
| 3.03 | Deep Freezers of capacity upto 425 ltr | 8 | Each | 900 ₹7,200 | 1,200 ₹9,600 | 850 ₹6,800 Lowest | 1,000 ₹8,000 | 1,100 ₹8,800 |
| 3.04 | Window type AC 1.5/2.0 Ton capacity | 20 | Each | 1,000 ₹20,000 | 1,000 ₹20,000 | 980 ₹19,600 | 860 ₹17,200 Lowest | 1,100 ₹22,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
16 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER EAST MATHURA
GE EAST MATHURA
REPAIR/MAINT OF COOLING AND SUMMER APPLIANCES ALONGWITH CONNECTED WORKS UNDER GE(E) MATHURA
2025_MES_715092_1
1489/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
₹1 L
Yes
12 Sept 2025
18 Jun 2025
18 Jul 2025
18 Jun 2025
16 Jul 2025
2 Jul 2025
18 Jun 2025 - 2 Jul 2025
Amount
Taking down of window/split AC 1.5/2.0 tonne of any make opening complete. Servicing of AC components carefully such as cleaning with chemical solution and soft nylon brush and change of air filters,tightnining of loose screw, checking wiring connection and tightening the same and rectification of defects if any assembling the same with body balancing and fixing in position and testing in the presence of Engineer-in-Charge complete all as specified and as directed. Note :- (i) Cost of unserviceable major parts as required shall be measured and paid separetaly under relevant items under this BOQ. (ii) The Spare Part item (s) required to be changed/replaced in appliance to make the appliance efficient workable shall of same makes/manufacturers of appliance. (iii) Servicing of same AC shall be carried out for two times in whole contract period and shall be measured as one unit "Each Job" for two services. Register shall be maintained for these services.
M&L for servicing / cleaning of the following appliances which included cleaning the body, storage tank, blow out the condenser coils with air blower, alignment and greasing, cleaning of fan bushes thorough checking of wiring and rectification of defects and leakages, cleaning of blockages of drain out-let connections, testing for smooth operation in presere of Engineer-in-Charge to entire satisfaction all as specified and directed. Note: (i) This service shall be carried out for three times in whole contract period and shall be measured as one unit "Each Job" for three services. Register shall be maintained for these services. (ii) Cost of Gas charging as in topping up as required to maintain desired gas pressure is deemed to be included in the unit rate quoted for this item.
Water coolers of capacity upto 280 Ltrs
Refrigerator of capacity upto 320 Ltrs
Deep Freezers of capacity upto 425 Ltrs
M&L for checking and rectify the leakage if any in the following appliances which included Testing leakage in system by injecting Nitrogen gas upto 300 PSI, rectification leaking spots/joints with gas welding work, filter anti moistoring agent, soldering, brazing, copper capillary tubing of reqd size and cleaning and flushing out complete system with gas making the system leak proof,vaccumising the complete system and supply and charging R-22/R407 refrigerant gas qty as required for the following type and capacity of appliances:- Note:- No extra cost shall be paid to the contractor for gas charging (any numbers of times) in case of leakage with in six months of initial gas charging except in case where external damage to the plant is noticed. Register shall be maintained for these leakage.
Water coolers of capacity upto 280 Ltrs
Refrigerator of capacity upto 320 Ltrs
Deep Freezers of capacity upto 425 ltr
Window type AC 1.5/2.0 Ton capacity
Split type AC 1.5 /2.0 Ton capacity
Supply, fixing, testing and commissioning of compressor sealed unit of the following appliances. Compressor sealed unit shall be of the same type (rotary/reciprocating) and same make as per existing including replacement of U/S copper tubing /capillary strainer etc incl taking down old U/S compressor sealed unit, copper tubing etc complete all as specified and as directed by of Engineer -in-charge.
Window type air conditioning of capacity 1.5 Ton.
Window type air conditioning of capacity 2.0 Ton.
Split type AC 1.5 Ton capacity.
Split type AC 2.0 Ton capacity.
Water coolers of 40 / 80 ltr capacity
Water coolers of 60 / 120 ltr capacity
Refrigerator of 165-195 ltr capacity
Refrigerator of 300-310 ltr capacity
Deep Freezers upto 425 ltr capacity
Supply & refilling in refrigerant gas R-32/R-410 for charging the all cooling appliances complete all as specified and as directed by of Engineer -in-charge.
All as per srl item No 5.00 here-in-above but for refrigerant gas R-22/R-134
Cutting of worn out bottom portion welded properly of bottom tray fabricted out of 20 guage MS CRC sheet for window type ACs capacity 1.5/2.0 ton complete all as specified and as directed.
Re-alignment of split AC 1.5/2.0 ton capacity including cutting of wall and making hole and change of liquid lines position in wall/roof by means of making sufficient grooves/channels and making good the disturbed surface including surface finish to match the exising finish complete all as specified and as directed.
S&F in repair running / starting capacitors of the following capacities for AC's complete all as specified and as directed.
S&F in repair starting relay suitable for following appliance of existing make & capacity complete all as specified and as directed by Engr-in-charge.
Window type AC of 1.5/2.0 TR capacity
Split type AC 1.5/2.0 Ton capacity
Water coolers of 40/80/120 Ltrs capacity
Refrigerator of 300 to 310 Ltrs capacity
Deep freezers of upto 425 Ltrs capacity
Contactor relay for split AC 1.5/2.0 TR capacity
S&F in repair thermostats suitable for following appliance of existing make & capacity complete all as specified and as directed by Engr-in-charge.
Window type AC of 1.5/2.0 TR capacity
Split type AC 1.5/2.0 Ton capacity
Water coolers of capacity upto 280 Ltrs
Refrigerator of capacity upto 320 Ltrs
Deep freezers of capacity upto 425 Ltrs
S&F in repair overload protector suitable for following appliance of existing make & capacity complete all as specified and as directed by Engr-in-charge.
Window type AC of 1.5/2.0 TR capacity
Split type AC 1.5/2.0 Ton capacity
Water coolers of capacity upto 280 Ltrs
Refrigerator of capacity upto 320 Ltrs
Deep freezers of capacity upto 425 Ltrs
S&F in repair copper condenser unit of the following appliances of existing make & capacity including making of all connections complete all as specified and as directed by Engr-in-charge.
Window type AC of 1.5/2.0 TR capacity
Split type AC 1.5/2.0 Ton capacity
Water coolers of capacity upto 280 Ltrs
Refrigerator of capacity upto 320 Ltrs
Deep freezers of capacity upto 425 Ltrs
S&F in repair evaporator coil /cooling coil of following appliances of existing make & capacity including making of all connections complete all as specified and as directed by Engr-in-charge.
Window type AC of 1.5/2.0 TR capacity
Split type AC 1.5/2.0 Ton capacity
Water coolers of capacity upto 280 Ltrs
Refrigerator of capacity upto 320 Ltrs
Deep freezers of capacity upto 425 Ltrs
S&F in repair float valve of water cooler of capacity upto 320 Ltrs complete all as specified and as directed
S&F in repair PVC insulated and sheathed circuler flexible, copper conductor cable 4 sqmm 3 core complete all as specified and as directed.
S&F in repair blower/condenser fan motor with necessary mounting bracket to and base frames for following appliances of existing make & capacity complete all as specified and as directed.
Water coolers of capacity upto 280 Ltrs
Refrigerator of capacity upto 320 Ltrs
S&F in repair indoor unit of split AC 1.5 ton single phase 230V, cooling/condensing coil assembly, electric fan motor with blower drum, control panel, front grill with nut/screws etc for fixing in wall complete set all as per specified and as directed.
All as per srl item No 19.00 here-in-above but for split AC 2.0 ton capacity
S&F in repair of electrical water heater storage type of capacity 25 ltr, BEE 5 Star rated complete all as specified and as directed.
Repair of voltage stabilizers, AC, single phase. upto 5 KVA of any make by opening of the body, cleaning of internally, checking and tighting of all terminal connections including replacement of worn out terminal connectors, screws, bolts complete as per specified and as directed.
S&F in repair of following parts of voltage stabilizer single phase 230V of following capacity :-
Main transformer 5 KVA Copper wound 170V to 230V.
Main transformer 3/4 KVA copper wound 170 V to 230 V.
Voltmeter flush type 230V, 0-300V ranging complete all as specified and as directed.
S&F in repair Printed circuit board (PCB) for time control/cut off for 12V system upto 10-25A suitable of 0.5 to 5 KVA stabilizer complete all as specified and as directed.
S&F in repair Electromagnetic relay copper wound 12V ranging 10-25A Suitable for 0.5 to 5 KVA stabilizer complete all as specified and as directed.
S&F in repair voltage stabilizer 5kVA, 230V complete all as specified and as directed.
S&F in repair of voltage stabilizer 4KVA, 230V complete all as specified and as directed.
S&F in repair of blower motor, double shaft, single/double speed, single phase, AC, 230V of suitable for existing window type AC 1.5/2.0 TR capacity complete all as specified and as directed.
S&F in repair of blower motor, single shaft, single speed, single phase AC, 230V suitable for indoor door unit of split type AC upto 2.0 TR capacity complete all as specified and as directed.
S&F in repair of blower motor, single shaft, single speed, single phase AC, 230V suitable for indoor door unit of split type AC upto 1.5 TR capacity complete all as specified and as directed.
S&F in repair of fan motor, single shaft, single phase, AC, 230V suitable as per chiller unit of AC capacity 4.0 TR complete all as specified and as directed.
S&F in repair heavy duty PVC flexible pipe with necessary fittings for split/Window ACs of any capacity complete all as specified and as directed.
S&F in repair front cover grill suitable for window type AC capacity upto 2.0 TR complete all as specified and as directed by Engr-in-charge.
S&F in repair Air fillter suitable for 1.5 ton/2.0 ton capacity window type AC complete all as specified and as directed.
All as per srl item No 34.00 here-in-above but for split type AC
S&F in repair 12 mm dia copper tubing for wondow/split AC of any capacity conforming to relevant IS complete all as specified and as directed.
All as per srl item No 36.00 here-in-above but 6mm dia
S&F in repair suction/discharge valve of size (1/4")/(3/8") suitable for split AC upto 2 TR capacity complete all as specified and as directed.
All as per srl item No 38.00 here-in-above but for valve of size (1/2")/(5/8")
S&F in repair fan blade set suitable for window AC of capacity 1.5/2.0 Tonne complete all as specified and as directed.
All as per srl item No 40.00 here-in-above but for split AC outdoor unit
S&F in repair remote control with PC board (PCB) complete suitable for split AC of capacity 1.5/2.0 tonne as per existing make and model complete all as specified and as directed.
All as per srl item No 42.00 here-in-above but for inverter type split AC
All as per srl item No 42.00 here-in-above but for hot and cold (inverter or non inverter type) split AC complete all as specified and as directed.
All as per srl item No 42.00 here-in-above but for Window type AC
S&F in repair remote of split/Window type AC of any capacity suitable for existing make and model of AC's with battery cell complete all as specified and as directed.
S&F in repair of outdoor unit including compressor, fan motor, condensor unit etc of split AC of 1.5 tonne capacity, single phase 230V (complete set) complete all as specified and as directed.
All as per srl item No 47.00 here-in-above but for Split AC of 2.0 tonne capacity
S&F in repair 15mm dia bore Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in pipe complete all as specified and as directed.
All as per srl item No 49.00 here-in-above but for 20mm dia bore.
S&F in repair 15mm dia bore push cock of brass chromium plated suitable for water cooler of any capacity complete all as specified and as directed.
All as per srl item No 51.00 here-in-above but for 20mm dia bore.
S&F in repair of water cooler inner tank made of stainless steel of capacity 40 Ltrs including necessary drilling work with nuts and bolts complete all as specified and as directed.
All as per srl item No 53.00 here-in-above but for 60 Ltrs
All as per srl item No 53.00 here-in-above but for 80 Ltrs
All as per srl item No 53.00 here-in-above but for 120 Ltrs
S&F in repair 1/2''X1/4'' dia copper pipe including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and as directed. Note:- 01 Meter of 1/2''copper pipe,01 Meter of 1/4'' dia copper pipe, 01 Meter PVC corrugated pipe shall be measured as one unit length.
S&F in repair 5/8''X3/8'' dia copper pipe including tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split AC complete all as specified and as directed. Note:- 01 Meter of 5/8'' internal dia, 01 Meter of 3/8'' internal dia shall be measured as one unit length.
S&F in repair of tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split AC complete all as specified and as directed.
S&F in Stands for fixing of outdoor unit of split ACs complete including nuts,bolts,clamps etc complete all as specified and as directed . Note:- working tools and plants used for fixing of outdoor unit on wall of height upto 5 mtr is included in quot rates
M&L for complete servicing & testing of reverse Osmosis plant of output capacity 100 ltrs per hour (RO,UV,UF) 230 volt AC, 7 stages purification, TDS upto 2000 PPM, rejection of TDS 90%, including filter feed pump 0.5 HP, dual media filter 3.5 kg/cm2, RO membrane-03 Nos, anti scalant dosing system 4 kg/cm2, micron filter set post carbon post corbon, reverse osmosis module, ultra violet set, high pressure pumb, min duty cycle 1200/ltr/day complete all as specified and as directed.
M&L for complete servicing & testing of Reverse Osmosis water purifier with TDS Adjester auto shut off stainless steel body of out put capacity 50 litres per hour 230 V, AC, including filter, removes ions, unwanted molecules and larger particles from drinking water using a partially permeable membrane-03 Nos complete all as specified and as directed.
Disconnecting the electrical and water connection of the desert cooler of any make /capacity and taking down from its position from various locations, transporting to MES Store Yard, opening the side pannels and remove the unserviceable /dirty wood wool pad/khas khas pad, dismantled the front grill including piano type switches, regulators, rotary switches, etc. If required Scratching out the old paint from inner and outer surfaces of cooler with sand paper complete and fixing the desert cooler and its parts complete as original and at original place including making water and electrical connections and testing etc. complete all as specified and as directed by Engineer-in-Charge. Note- (i) Wood wool pad/Khas Khas pad and PVC pipe and any other parts of desert cooler excluding nut, bolts, screws etc. shall be measured and paid separately under appropriate item of this Sch and cost of fixing only is deemed to be included in the unit rate.
Supply only Wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire as required for Desert coolar of any size complete all as specified and as directed
Supply only Cooler fan motor 230V with super enameled copper wire of existing size including testing suitable for 4000 CFM complete as directed
Supply only Fan blades suitable for motor of capacity 4000 CFM complete as directed
Supply only 3 pin plug top one way 5 Amp, 230Vcomplete as directed
Supply only Water lifting pump 230 V, single phase, submersible type complete as directed
Supply only Front show grill of desert cooler made of Stainless steel. complete all as specified and as directed
Supply only Side grill of desert cooler made of stainless steel for fixing wood wool pad including iron wire mesh complete all as specified and directed.
Supply only Flexible wire of 1.5 sqmm 3 core complete as directed.
Supply only Fan regulator suitable for metal body desert cooler.
Supply only Three way water distributer assembly on Pads alongwith connecting PVC Pipes complete as directed.
M&L for Painting of Desert cooler by applying two coat of synthetic enamel paint of grey colour with spray gun/machine to achive smooth finish and writing of MES No complete all as specified and as directed.
S&F in repair of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of standard size with double diversion grills and grill box suitable for 450mm sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spray water, wood wool pads, electrical wiring, fan & pump set, 5 amp Piano type switch and indicator complete all as specified and as directed.
Taking down ceiling fans/exhaust fans/fresh air fans of any make and type for rectifying the defects including replacement of unserviceable parts to make the fans fully functional testing and reinstalling at same or any other location as directed at site by Engineer-in-charge. Notes : (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete will be provided without any extra cost and cost of these minor items or works will be deemed to be included in the quoted rates against this item and nothing extra shall be paid on this account. (iv) The Spare Part item (s) required to be changed/replaced in appliance to make the appliance efficient workable shall of same makes/manufacturers of appliance.
Supply only following items in corporation in Serial Item No 76.00 here-in-above.
Bush made out of Gun metal suitable for ceiling fan/exhaust fan as required at site complete all as specified and as directed.
Shaft of approved quality for ceiling fan as per existing make, type and size complete all as specified and as directed.
Canopy (set of two) suitable for ceiling fans of any make, type and size complete all as specified and as directed.
Rubber reel with clamp including split pins and nuts, bolts for ceiling fans complete all as specified and as directed.
Down rod MS grade 15 mm bore of length upto 75 cm size for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as specified and as directed.
Capacitors 2.5 MFD suitable for all types of fans complete all as specified and as directed.
Capacitors 4.0 MFD suitable for all types of fans complete all as specified and as directed.
SKF 6201 ball bearing suitable for ceiling fan of any type as required including proper alignment of shaft and testing complete all as specified and as directed.
SKF 6202 ball bearing suitable for ceiling fan of any type as required including proper alignment of shaft and testing complete all as specified and as directed.
SKF 6203 ball bearing suitable for exhaust fan of any type as required including proper alignment of shaft and testing complete all as specified and as directed.
Exhaust fan blade of same type and make as existing or as directed at site complete all as specified and as directed.
MS louvers with nuts, bolts and washers suitable for exhaust fan upto 350 mm sweep of same type and make / model as existing complete all as specified and as directed.
MS louvers with nuts, bolts and washers suitable for exhaust fan upto 450 mm sweep f same type and make / model as existing complete all as specified and as directed.
Suitable frames for 300/375/450 mm sweep exhaust fan of any description/make/model complete all as specified and as directed at site.
Exhaust fan motor 18'' copper winding, 1450 rpm, 230V , 50 Hz ,with fixing accessories to mount on frame complete all as specified and as directed.
Exhaust fan motor 12'' copper winding, 230V , 50 Hz ,with fixing accessories to mount on frame complete all as specified and as directed.
Exhaust fan motor suitable for 8'' to 10'' PVC ventilator/ fresh air fan, copper winding, 230V, 50 Hz , with fixing accessories to mount on frame complete all as specified and as directed.
Dismantling of worn out/ burnt out windings of ceiling / exhaust fan and re-winding the motor of ceiling / exhaust fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing for original and consumption complete all as specified and directed for following sizes:-
Ceiling fan of 1200 mm sweep.
Ceiling fan of 1400 mm sweep.
Exhaust fan of 200/230 mm sweep.
Exhaust fan of 300 mm sweep.
Exhaust fan of 450 mm sweep.
M&L for spray painting to ceiling fan 1200 mm/1400 mm with blades 3 Nos of any type and applying one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed.
M&L for spray painting to exhaust fan with blade of any type and size with one coat of synthetic enamel paint as approved by Engr-in-charge including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed.
S&F in repair ceiling fan blade (1200mm sweep) of same type and make as per existing on site complete all as specified and as directed.
S&F in repair ceiling fan blade (1400mm sweep) of same type and make as per existing on site complete all as specified and as directed.
S&F in repar of fresh air/ventilator fan made of sturdy engineering plastic with built in louvers, AC, 230Volt single phase, 50 Hz, incl depositing the old one in MES store yard complete all as specified and directed of following sizes :-
150mm Sweep
200mm Sweep
250mm Sweep
S&F in repair of Ceiling fans of size 1200mm sweep, BEE, 5 star rated complete 230 Volt, including hanging arrangement and connections at site and incl writing MES No. complete all as specified and as directed. Note : Old ceiling fans shall be deposited by contractor in AGE E/M (E) Mathura store and obtain the receipt thereof.
S&F in repair of exhaust fan heavy duty 300 mm sweep AC 230Volt Metal body single phase including louvers and connection and incl writing MES No. complete all as specified and as directed. Note : Old exhaust fan shall be deposited by contractor in store of AGE E/M (E) Mathura and obtain the receipt thereof.
All as per srl item No 85.00 here-in-above but for 450 mm sweep
S&F in repair step type electronic fan regulator, switch type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F in repair step type electronic fan regulator, socket type on the existing phenolic laminated sheet complete all as specified and as directed.
S&F in repair modular step type electronic fan regulator, 100W on the existing laminated sheet complete all as specified and as directed.
S&F PVC insulated sheathed, 1.5 sqmm 3 core, copper conductor cable 1100 volts grade ISI marked complete all as specified and as directed.
S&F PVC insulated sheathed, 2.5 sqmm 3 core, copper conductor cable 1100 volts grade ISI marked copper conductor complete all as specified and as directed.
S&F in repair of electrical water heater storage type of capacity 3 ltr complete all as specified and directed.
M&L rolled mild steel Joist, channel, angle or tee sections ( GDE Fe 290 ) as in framing for stand for Desert cooler, voltage stabilizer, ACs or for any other purpose with riveted bolted or welded attachment etc and inclusive of one primer coat , two coat of synthetic enamel paint after preparation of new steel surface complete all as specified and as directed.
Taking down aluminium/copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc, removing materials to store for keeping in safe custody or for taking credit and making good to the disturbed surfaces of walls, ceilings and floors etc complete all as directed.
Taking down MCB distribution boards with incoming and outgoing controls any make and capacity after disconnecting of electric connections complete all as specified and as directed.
Taking out existing copper/aluminium sub main wiring of any size and making good the disturbed surfaces complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall / roof incl cutting & chases( making good all to the disturbed surfaces as per existing) and including with modular flush metal boxes with modular cover plate and frame for mounting modular switches, socket, regulator etc and including earth wire of PVC insulated FRLS copper conductor multistranded of 1.5 Sqmm size in green colour for one light/fan/bell point controlled by one switch complete all as specified and as directed.
All as per item No 97.00 here-in-above but for One 3 pin, 5 Amps socket point controlled by one way switch on independent board
All as per item No 97.00 here-in-above but for One 3 pin, 5 Amps socket point controlled by one way switch on same board
All as per item No 97.00 here-in-above but for One light point controlled by two way switch
All as per item No 97.00 here-in-above but for 15 Amps socket point with 2.5 sq mm single core multi-stranded FLRS copper conductor along with 2.5 sq mm continuous PVC insulated unsheathed FLRS solid copper conductor cable for earth continuity wire
S&F switch modular type 6 Amps complete all as specified and as directed.
S&F socket outlet modular type 2-in-1, 3 Pin, 2 module 6 Amps 230 volt complete all as specified and as directed.
S&F switch modular type, single pole one module 16 Amps 230 V complete all as specified and as directed.
S&F socket modular type 2-in-1, 5 Pin, 6/16 Amps 2 module complete all as specified and as directed.
S&F modular bell Push switch 6 Amps, 1 Module complete all as specified and as directed.
S&F modular switch 2 way 6 Amp, 1 Module complete all as specified and as directed.
S&F in repair switch modular type 6 Amps complete all as specified and as directed.
S&F in repair socket outlet modular type 2-in-1, 3 Pin, 2 module 6 Amps 230 volt complete all as specified and as directed.
S&F in repair switch modular type, single pole one module 16 Amps 230 V complete all as specified and as directed.
S&F in repair socket modular type 2-in-1, 5 Pin, 6/16 Amps 2 module complete all as specified and as directed.
S&F in repair modular bell Push switch 6 Amps, 1 Module complete all as specified and as directed.
S&F in repair modular switch 2 way 6 Amp, 1 Module complete all as specified and as directed.
S&F switch socket combination 2 in 1, flush type 6 Amps 240 V complete all as specified and as directed.
S&F switch socket combination, flush type, 3 & 5 pin multipurpose 6 & 16 Amps 240 V complete all as specified and as directed.
M & L for Point wiring complete with 1.5 Sqmm single core PVC insulated (FRLS) cable 1100 volts grade with multi-standard copper conductor drawn through and including including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories such as internal bend end cpas etc complete fixed in wall/ceiling/roof etc by means of suitable GI saddles/Spacers and including earth wire of PVC insulated FRLS copper conductor multistranded of 1.5 Sqmm size fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls with 3mm thick bakelite top cover sheet ISI marked with chromium plated screws and cup washers for one light/fan/bell point conrolled by one swithch complete all as specified as directed.
All as per item No 116.00 here-in-above but for One 3 pin, 5 Amps socket point controlled by one way switch on independent board
All as per item No 116.00 here-in-above but for One 3 pin, 5 Amps socket point controlled by one way switch on same board
All as per item No 116.00 here-in-above but for One light point controlled by two way switch
All as per item No 116.00 here-in-above but for 15 Amps socket point controlled by 15 Amp swich with 2.5 sq mm single core multi-stranded FLRS copper conductor along with 2.5 sq mm continuous PVC insulated unsheathed FLRS solid copper conductor cable for earth continuity wire
S&F switch piano flush type 5 Amps, SP, one way complete all as specified and as directed.
S&F socket outlet flush type 2-in-1, 3 pin, 5 Amp complete all as specified and as directed.
S&F switch flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F socket out let flush type 2-in-1, 3/6 pin,15 Amp complete all as specified and as directed
S&F switch piano flush type 5 Amps, SP, two way complete all as specified and as directed.
S&F bell push switch 6 Amps, flush type, SP, one way complete all as specified and as directed.
S&F in repair switch piano flush type 5 Amps, SP, one way complete all as specified and as directed.
S&F in repair socket out let flush type 2-in-1, 3 pin 5 Amp complete all as specified and as directed.
S&F in repair switch flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F in repair socket out let flush type 2-in-1, 3/6 pin 15 Amp complete all as specified and as directed
S&F in repair switch piano flush type 5 Amps, SP, two way complete all as specified and as directed.
S&F in repair bell push switch, 6 Amps, flush type complete all as specified and as directed.
S&F in repair Bell multi-music type, 230 Volts complete with complete all as specified and as directed.
S&F in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
M&L for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn through rigid non -metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases (making good all to the disturbed surfaces as per existing) and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire & 25mm dia PVC Conduit shall be measured as one unit length.
All as per item No 139.00 here-in-above but for 4 Sqmm cable
All as per item No 139.00 here-in-above but for 2.5 Sqmm cable
M&L for Sub Main Wiring with four runs of single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with multistranded, 1100 volts grade copper conductor drawn through rigid non -metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases (making good all to the disturbed surfaces as per existing) and including two runs of single core PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. Note: Four runs of 6 Sqmm cable, two run of 6 Sqmm earth wire & 25mm dia or higher dia of PVC Conduit shall be measured as one unit length.
S&F in repair sheet metal enclosure MCB distribution board, TPN 4 Way, Double door, phosphatised, powder painted with 200Amp rated bus-bar, neutral link, earth bar and din rail, cable ties for cable management, 240 V complete all as specified and as directed.
All as per item No 139.00 here-in-above but for SPN 8 Way
All as per item No 139.00 here-in-above but for SPN 4 Way
S&F powder coated CRCA steel sheet metal enclosure MCB distribution board, SPN 8 Way, IP-43, IK-09 protection, double door recess mounted, powder coated with 100Amp rated bus-bar, neutral link, earth bar and din rail , cable ties for cable management, 240 V complete all as specified and as directed.
S&F powder coated CRCA steel sheet metal enclosure MCB distribution board, SPN 2 Way, single door recess mounted, powder coated with 100Amp rated bus-bar, neutral link, earth bar and din rail , cable ties for cable management, 240 V complete all as specified and as directed.
S&F in repair SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20-32 Amps, 240 Volts complete all as specified and as directed.
S&F in repair 4 Pole TPN MCB 63-100 Amps ,415 V, 50Hz, with repturing capacity 16 KA complete all as specified and as directed.
S&F in repair MCB DP 40-63 Amps, 'C' series, breacking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair Single pole, MCB 6-32 Amps, 240 V, 50Hz,10KA breaking capacity complete all as specified and as directed.
S&F in repair MCB SPN 32 Amps, 'C' series, breacking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair of indoor decorative ultra slim surface /Wall mounted aluminium extruded T5 LED batten tube light complete fitting 1x 20 watt 4' LED Tube fitting complete all as specified and as directed.
S&F in repair of environmental friendly, ultra modern, energy saving, surface mounted, Bulk Head fitting of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and as directed.
S&F in repair of LED T-5 Intergrated Batten PC housing extruded 2' light fittings 9W complete all as specified and as directed.
S&F in repair of building street light fitting, IP66 powder coated pressure die cast aluminuim with jeat resistant thoughened glass complete of 30 Watt capacity including fixing arrangement complete with all accessories including connecting up with twin core copper cable with suitable size all as directed.
S&F 40mm dia tube medium grade galvanised with all fitting and fixed complete in/on the wall, roof for hanging of fan hook including making good the disturbed surface to match with the existing complete all as specified and as directed.
S&F in repair LED retrofit lamp 9 Watt complete all as specified and as directed.
S&F hook for hanging ceiling fan condirming to Fe-290 Gde-E-165, size as per site requirements including nut bolts & clampx complete all as specified & directed.
S&F in repair LED Round recess mounted downlighter with die cast aluminium housing 20W including connected up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated cable of size 10 sqmm 4 core, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches/duct/fixing on walls/poles including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole/Main Panel Box incl taking down old U/S cable complete all as specified and as directed of following sizes :- Note:- Excavation and earth work shall be measured and paid separately under relevant item(s) of this schedule.
All as per item No 157.00 here-in-above but for XLPE cable of size 16 sqmm 4 core
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundations laying of cable in soft /loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering & well ramming in layer not exc 25cm thick complete all as specified and as directed.
Removing excavated meterial n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed
M&L for filling dry fine sand in trenches for sand cushioning for protection of under ground cable spreading, levelling and hand punning complete all as specified and directed. Note : Punned down thickness will be measured for payment purpose.
Supply and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed.
S&F in repair of bottom tank of desert cooler made of MS CRC Sheet 0.8mm thick of 800x700x550mm size rebated at corners nut, botls, joints sealed to make tank leak proof complete all as specified and as directed.
M&l for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling incl necessary excavation and earth work complete all as specified and as directed.
Ms Kamal Kant Agarwal (BID ID -3346979)
M/S S S CONSTRUCTION (BID ID -3361028)
ISHWAR ENTERPRISES (BID ID -3352999)
BUILDTECH ASSOCIATES (BID ID -3352679)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .