| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.9 LAccepted-AOC AK PO GHANTAPADA TALCHER ANGUL ODISHA | TALCHER | ANGUL | ODISHA | L-1 | Accepted-AOC Awarded due to becoming techno-commercially eligible L-1 bidder. | |
| 2 | L-2₹20.2 L+₹9,286.08 (0.46%)Rejected-Finance AT PO REMUAN TALCHER DIST ANGUL ODISHA 759100 | TALCHER | ANGUL | ODISHA | 759100 | L-2 | Rejected-Finance Rejected due to not becoming techno-commercially eligible L-1 bidder. | |
| 3 | L-3₹20.4 L+₹27,529.28 (1.37%)Rejected-Finance AT PO KALAMUCHHIN PS COLLIERY TALCHER DIST ANGUL PIN 759103 ODISHA | TALCHER | ANGUL | ODISHA | 759103 | L-3 | Rejected-Finance Rejected due to not becoming techno-commercially eligible L-1 bidder. |
Tender Value
₹21.8 L
EMD Value
₹27,300
Closing Date
4 Apr 2023, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Day to day Maintenance Work for 11 KV overhead line from Balanda substation to Ananta Vihar Colony substation of Ananta OCP Jagannath Area for a period of two year
2023_MCL_276163_1
GM(JA)/EnM/ e-Tender/2023/E-573/66 dated20/03/2023
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
Talcher
AS PER NIT
4 documents required · 4 mandatory
₹27,300
30 May 2023
21 Mar 2023
6 Apr 2023
22 Mar 2023
4 Apr 2023
22 Mar 2023
22 Mar 2023 - 27 Mar 2023
Amount
Dismantling of overhead lines comprising of copper/aluminium over head conductor, G.I wire, cross arms, insulators etc as required.
Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc. as required.
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of 33 kV 90 KN polymer type disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 33 Kv polymer type pin insulator 10 KN complete with large steel head GI pin, nuts, washers etc. as required.
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required.
Erection of all aluminium conductors of 7 / 1.96 to 7/3.10mm diameter including binding etc. as required.
Erection of G.I Wire, 8 SWG including binding etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required .
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required.(0.5X0.5X50 nos=12.5 CUM)
Erection of cradle guard as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Clamps, bolts, nuts etc.
Supply of G.I wire 6 SWG
Trimming / cutting of tree branches with 4 person including cutting accessory.
Painting of One Lighting Pole & bracket with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel pole (12mtr long)
Painting of One Lighting Pole & bracket with painting of aluminium paint of approved brand and manufacture to give an even shade (12mtr long)
Numbering of the pole by painting a long of 600mm length of all surface with synthetic enamel paint of approved brand.
Maintenance/Erection/Dismantling of 11 Kv GOAB switches .
Supply of 630A Horizontal type GOAB male & female contact for 3 nos. for 1 GOAB
Supply of 400A Horizontal type GOAB male & female contact for 3 nos. for 1 GOAB
Supply of Mechanism Ball Bearing for GOAB operating Rotor
Supply of GOAB operating long pipe with necessary arrangement as required
Total impact of GST for the purpose of CTC
MESSERS UTKAL ELECTRICALS
TRISHAKTI ENGINEERING
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .