Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹46.6 L+₹3.4 L (7.94%)Rejected-Finance MB 58 JUNGLIGHAT KATHIR MARKETING SERVICE MB 58 JUNGLIGHAT NEAR TCI OFFICE SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹49.2 L+₹6.1 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹50.4 L+₹7.3 L (16.9%)Rejected-AOC DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-AOC Being not the lowest | |
| 5 | L5₹50.4 L+₹7.3 L (16.9%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE Minniebay, Port Blair
REPAIR/MAINT OF E/M INSTALLATIONS, LIGHTENING PROTECTION SYSTEM, REPAIRS TO WATER DISTRIBUTION SYSTEM, SERVICE TANKS AND ALLIED WORKS UNDER AGE E/M II AT GE MINNIEBAY, PORT BLAIR
2022_MES_503288_2
8129/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹80,000
Yes
29 Mar 2022
18 Feb 2022
14 Mar 2022
18 Feb 2022
11 Mar 2022
4 Mar 2022
60 days
Amount
Taking down carefully aluminum / copper strips of any size & type including unserviceable insulators etc from roof of bldg /wall complete all as specified and as directed
Taking down unserviceable rusted test point terminal boxes from wall or similar position complete all as specified and as directed
Taking down unserviceable air termination rod from roof top complete all a specified and as directed
S&F aluminium strips 25x3 mm on porcelain insulator 15 BMD size 'T' type not more than 50 cm apart complete all as specified and as directed
Refixing of serviceable aluminium strips on porcelain insulators 15 BMD size 'T' type placed not more han 50 cm apart in old or new position fixed with srews & nut bolts complete all as specified and as directed.
S&F copper strips 20x3.15 mm on porcelin insulator 15 BMD size 'T' type placed not more than 50 cm apart complete all as specified and as directed
Refixing of serviceable copper strips on porcelain insulators 15 BMD size 'T' type placed not more han 50 cm apart in old or new position fixed with srews & nut bolts complete all as specified and as directed.
S&F in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and crewed including 3 nos. 8mm dia 2 5mm long hex. head screw complete all as specified and as directed
Supply and fix inreplacement air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed
All as per item No 9.00 abov bove but copper air termination rod complete all as specified and as directed
S&F in replacement Galvanised stay strand (Grade 2), size 7 / 4 mm complete with ms clamps, nuts and bolts etc complete all as specified and as directed.
S&F in replacement porcelion insulators 15 BMD size T type including nut, bolts / screws for fixing complete all as specified and as directed
S&F in replacement UPVC cable/wiring tracking system 50X105 mm with 45 mm cover including all routing sections and accessories such as bends, separator, angles, junction box, taping points etc including all as specified and directed.
M&L for repairs to earthing chamber of size 450x450x300mm depth outside & 250x250x250 mm depth of PCC 1:4:8 type D-2 using 20mm graded stone aggregate ncluding provn of PCC cover complete all as specified and as directed
M&L for earthing resistance testing of existing earth pits with different types of earth megger as to suit by disconnecting earth contiuity conductor from test terminal block / panel and recording the results in triplicate duly signed by contractor, MES rep and user rep and reconnecting the earth continuity conductor Note : Earth maggers shall be provided by the contractor for testing
M & L for cutting of existing GI tubing medium grade and insertion of 'T' taking connection for earthing pipe line including cutting threading and all fitting complete all as specified and as directed
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting out in soft / loose solil complete all as specified and as directed
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting out in hard / dense solil complete all as specified and as directed
Returning / Refilling of excavated soil including spreading levelling and well ramming in layers complete all as specified and as directed
Removing excavated surplus soil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and as directed.
S&F in replacement gun metal gate valve with iron wheel head, screwed both ends for iron pipe of size 15mm bore and fixed complete all as specified and as directed
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 25x4 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper earth strip 20x3 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
M&L in repairs GI earth continuity conductor or main earthing lead of size 32x6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed
M&L in repairs GI earth continuity conductor or main earthing lead of size 25x4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed
Supply and laying in replacement LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade of aluminium conductor of following sizes complete all as specified and as directed including taking up/down old unsv cable :-
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 110 mm and inner dia 95 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable including taking down/up old unsv DWC pipes complete all as secified and directed
All as per item No 28.00 above but outer dia of 120 mm and inner dia 103.5 mm complet all as specified and as directed
All as per item No 28.00 above but outer dia of 160mm and inner dia 126 mm complete all as specified and as directed.
S & F in replacement of digital soft starter suaitable for 15 HP submersible pump including all connection complete all as specified and directed
Demolition of RCC of any description and in any position (RCC overhead tanks, shelves RCC parapet/railing etc) other than ground and floor and removing the debris from work site all as specified and as directed
M & L for PCC type B1 1:2:4 using 20mm graded stone aggregate as in roof padding including necessary form work as required complete all as specified and as directed
M & L for 10mm thick cement plastering in cement mortar 1:6 on brick work or concrete surface finished even & smooth without using extra cement complete all as specified and directed.
M & L for PCC 1:3:6, type C2 using 40mm grade stone aggregate as in foundation concrete etc all as specified and as directed
S&F in replacement rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) double layer with lid of capacity 1000 litre and providing proper locking arrangements etc, hoisted and fixed in position all as specified in SSR complet all a specified and as directed
S&F in replacement ball valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe and fixed ( Minimum weight 20mm - 210gms / 25mm - 455 gm) of 20mm size all as specified and directed
S&F in replacement gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed of the following sizes :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
S&F in replacement GI tubing of medium grade with all fittings laid in trenches/fixed on wall/on roof etc of the following sizes :-
20mm dia
25mm dia
40mm dia
50mm dia
80mm dia
M&L for schematic diagram for water/electric supply distribution system, details of pump motor/ transformer/VCB/Cables at various locations under AGE E/M II duly framed with lamination sheet cover of size 1.5MX1M fixed on wall / GI pipe including fixing accessories complete all as specified and as directed
S&F in replacement of globle premium chequered electrical rubber mat of thickness 8mm for LT 440 Volts of size 1x2 meter complete all as directed
S&F in replacement glow shine board made from high quality cast acrylic of size 4 x 1.5 mtr raised to the depth of 6 inch fixing with angle iron of suitable size, durable and waterproof ,impressive with bright LED with tube lights necessary demolition and PCC work for fixing the board including electrical connection from ceiling rose to glow shine board with 1.5 sqmm, 3 core, copper conductor upto 5 mtrs length, complete all as directed
S&F in replacement of sluice valve suitable for 50mm bore pipe with stainless steel spindle and iron wheel head long body class PIN 1.6 complete with rubber gaskets, nut and bolts of suitable size, ISI marked conforming to IS-14846 complete all as specified and as directed
All as per item No 43.00 above but suitable for 80mm bore pipe complete all as specified and as directed
All as per item No 43.00 above but suitable for 100mm bore pipe complete all as specified and as directed
All as per item No 43.00 above but suitable for 150mm bore pipe complete all as specified and as directed
All as per item No 43.00 above but suitable for 200mm bore pipe complete all as specified and as directed
All as per item No 43.00 above but suitable for 250mm bore pipe complete all as specified and as directed
S&F in replacement Butterfly valve suitbale for 200mm dia pipe complete all as specified and as directed
S&F in replacement Butterfly valve suitbale for 150mm dia pipe complete all as specified and as directed
S&F in replacement Butterfly valve suitbale for 100mm dia pipe complete all as specified and as directed
S&F in replacement Butterfly valve suitbale for 80mm dia pipe complete all as specified and as directed
S&F in replacement Butterfly valve suitbale for 65mm dia pipe complete all as specified and as directed
S&F in replacement Butterfly valve suitbale for 50mm dia pipe complete all as specified and as directed
S&F in replacement GI Flange of 50mm bore with suitable size nuts and bolts complete all as specified and as directed
S&F in replacement GI Flange of 80mm bore with suitable size nuts and bolts complete all as specified and as directed
S&F in replacement GI Flange of 100mm bore with suitable size nuts and bolts complete all as specified and as directed
S&F in replacement GI Flange of 150mm bore with suitable size nuts and bolts complete all as specified and as directed
S&F in replacement GI tank nipple of size 25/40mm bore complete all as specified and as directed
S & F in replacement of star delta starter suaitable for 10 to 15 HP submersible pump including all connections complet all as specified and as directed
Repair / maint of electrically operated travelling / hand operated travelling crane of 5 Ton capacity comprising of gear box, control panel and connected accessories complete oiling, greasing incl replacement of unserviciable spares complete all as specified and as directed. Note : Spares shall be measured under relevent items of this schedule separately as supply only.
Supply only of following spares for 5 ton capacity crane:-
Break assembly
Key lock assembly
Break ON / OFF mechanism
Ball bearing for LT / CT hoist
S & F in replacement of star delta starter suaitable for 50 to 65 HP submersible pump including all connections complet all as specified and as directed
Kathir Marketing Services
M/s Bismi Builders & Enterprises
Sree Tirumala Enterprises
ANITA VARMA ENTERPRISES
M/s K Moorthi
M/s Ramesh Lal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .